PREDIMENCIONAMIENTO DE COLUMNAS

CALCULANDO AREAS TRIBUTARIAS


DATOS:
P. Aligerado = 300 KG/m2
Tabiquería = 120 Kg/m2
Acabado = 100 Kg/m2
P. Columnas = 60 Kg/m2
Sobre Cargas = 250 Kg/m2

ENTONCES:
PG = P. Muerta + P. Viva = 980 KG/M2

PREDIMENCIONAMIENTO DE VIGAS
Para Oficinas y Departamentos S/C = 250 Kg/ m2
Determinar Wu:
- P. aligerado = 350 kg/m2
- P. acabado = 100Kg/m2
- Tabiquería móvil = 150 Kg/m2
- WD = 600 Kg/m2
- WL = 250 Kg/m2
- Wu = 1.2 WD + 1.6 WL

= 1120 KG Usamos:
Wu = 0.12 Kg/cm2 h= Ln
11.5

h = 2.23 = 0.19 = 0.20 h = 2.62 = 0.20 h = 2.14 = 0.20


11.5 11.5 11.5
b = 3.59 = 0.18
20

ASUMIENDO MEDIDAS TOMANDO EN CUENTA LAS COLUMNAS 0.40 X


0.40
3
bxh3 = b1 x b13 = 0.18 x 0.35 = 0.40 x h13
h1 = 0.26
b1 = 0.40
DISEÑO DE INSTALACIONES SANITARIAS – AGUA

PLANTA PRIMER NIVEL


SEGUNDO NIVEL
DISEÑO DE INSTALACIONES SANITARIAS – DESAGUE

PLANTA PRIMER NIVEL


SEGUNDO NIVEL
UBICACIÓN DE MUROS PORTANTES

SE COLOCAN LOS MUROS PORTANTES DEVIDO


PLANTA PRIMER NIVEL
A QUE SON MUROS QUE CUENTAN CON POCOS
VANOS, TIENEN UNA CONTUNIEDAD HASTA EL
SEGUNDO NIVEL Y VA SOPORTAR CARGAS.