Plano de dimensiones
A3 Product D1 D2 A1 A2 A3
A1
D1
D2
Datos fotométricos
1 x 2500 lm
80
o
120 180 120o nr. of luminaires
16.0
hroom: 2.8 m 25 hroom : 2.8 m
Reflectances: 0.70, 0.50, 0.20 28 Refl: 0.70 0.50 0.20
m
90o 90o 40 Maintenance factor: 1.0 Ceiling mounted
Ceiling mounted
50 12.0 : viewed endwise
Y 25 : viewed crosswise
30 750 lx
60o 100 60o 25
Y : Parallel to viewing dir.
150 20 500 lx
8.0
200
300 lx
250 10
γ
30o 300 30o 4.0
0
o 2
(cd/1000lm) 0 10 30 50 70 90 (m ) 4.0 8.0 12.0 m 16.0
X
0-180o 90-270o
Utilisation factor table Luminance Table
60
Light output ratio 1.00
Service upward 0.15 Reflectances (%) for ceiling, walls and working plane (CIE) Plane 0.0 15.0 30.0 45.0 60.0 75.0 90.0
Room Cone
Service downward 0.85 0.80 0.80 0.70 0.70 0.70 0.70 0.50 0.50 0.30 0.30 0.00
45.0 10512 10213 10255 10659 11519 12993 15428
Index 0.50 0.50 0.50 0.50 0.50 0.30 0.30 0.10 0.30 0.10 0.00
50.0 9893 9551 9552 9920 10718 12171 14731
CIE flux code 40 69 88 85 100 k 0.30 0.10 0.30 0.20 0.10 0.10 0.10 0.10 0.10 0.10 0.00
55.0 9302 8920 8883 9212 9918 11299 13930
60.0 8724 8312 8244 8543 9127 10389 13027
UGRcen (4Hx8H, 0.25H) 25 0.60 0.43 0.41 0.41 0.40 0.40 0.32 0.31 0.26 0.29 0.25 0.22
0.80 0.53 0.50 0.51 0.49 0.48 0.40 0.38 0.33 0.36 0.32 0.28 65.0 8181 7743 7647 7915 8347 9431 11985
1.00 0.61 0.57 0.59 0.57 0.55 0.47 0.45 0.40 0.43 0.38 0.34 70.0 7686 7228 7110 7356 7605 8442 10770
1.25 0.69 0.63 0.66 0.64 0.61 0.54 0.51 0.46 0.49 0.44 0.40 75.0 7256 6786 6657 6898 6927 7427 9266
1.50 0.75 0.68 0.72 0.69 0.66 0.59 0.56 0.51 0.53 0.49 0.44 80.0 6888 6401 6259 6495 6280 6343 7175
2.00 0.85 0.76 0.81 0.77 0.73 0.67 0.64 0.59 0.60 0.57 0.51
85.0 6560 6056 5904 6140 5719 5343 4205
2.50 0.91 0.81 0.87 0.82 0.78 0.73 0.69 0.65 0.65 0.62 0.56
3.00 0.96 0.84 0.92 0.86 0.82 0.77 0.73 0.69 0.69 0.66 0.60 90.0 6286 5771 5620 5882 5481 5141 1786
4.00 1.02 0.89 0.97 0.91 0.86 0.82 0.77 0.74 0.73 0.71 0.65 (cd/m2)
5.00 1.06 0.91 1.01 0.95 0.89 0.85 0.81 0.78 0.76 0.74 0.68
Ceiling mounted
2016-12-27
40
20
0
200 300 400 500 600 700 800
CalcuLuX Photometrics 4.5 Philips Lighting B.V. Page: 1/1 [nm]
Datos fotométricos
o
90 90
50
60o 100 60o
150
200
250
30o 300 30o
(cd/1000lm) 0o
0-180 o 90-270 o
Vida útil
80 95
90
60
85
40
80
20 75
0 70
0 10000 20000 30000 40000 50000 60000 0 10000 20000 30000 40000 50000
Time (hours) Burning hours
© 2021 Signify Holding Todos los derechos reservados. Signify no otorga representación o garantía con respecto a la
exactitud o integridad de la información incluida aquí y no será responsable de ninguna acción que dependa de la
misma. La información presentada en este documento no está destinada a su uso con fines comerciales ni forma
parte de ningún presupuesto ni contrato, a menos que Signify acuerde otros términos. Philips y el emblema de escudo www.lighting.philips.com
de Philips son marcas comerciales registradas de Koninklijke Philips N.V. 2021, Junio 29 - Datos sujetos a cambios