Está en la página 1de 2

Slide Guards

8 12
8:12
7:12
6:12 6:12
5:12
4:12
3:12

Slope: 3:12 to 6:12 Slope: 6:12 + to 8:12 Slope: 8:12 +


Roof Height: 25’ maximum Roof Height: 25’ maximum Roof Height: 25’ +
One Slide Guard Row Several Slide Guard Rows Slide Guards CAN’T
BE USED for Fall
Protection
8’
Maximum
Between
the
Brackets

8’
Maximum
Between
Slide Guard the
Overhang Slide
Beyond the Guards
Bracket:

Ask
Manufacturer

((Some
recommend At least
6” to 12”) 6” From
Roof
Edge
25’ o
Maximum 90
Ground- Degrees
t E
to-Eave Brackets
and Slide
Guards

OR-OSHA – PESO TOOLBOX SHEET HOJA INFORMATIVA DE OR-OSHA – PESO


1 (800) 922-2689 or visit www.orosha.org 1 (800) 843-8086 opción No. 3 ó visite www.orosha.org
Tablas Contra Deslizamiento

8 12
8:12
7:12
6:12 6:12
5:12
4:12
3:12

Pendiente: 3:12 to 6:12 Pendiente: 6:12 + to 8:12 Pendiente: 8:12 +


Altura Techo: 25’ máximo Altura Techo: 25’ máximo Altura Techo: 25’ +
Una Hilera de Tabla Contra Varias Hileras de Tablas Tablas Contra
Deslizamiento Contra Deslizamiento Deslizamiento NO SE
USARÁN como protección
contra caídas

8’
Máximo
Entre las
Ménsulas

8’
Máximo
Entre las
Tablas
El Sobresaliente Contra
d lla Tabla
de T bl Deslizamiento
Contra
Deslizamiento
Desde la
Ménsula:

Pregute al
Fabricante
Por lo
(Algunos Menos 6”
Recomiendan del
(6” a 12”) Borde
25’ o
del Techo
Máximo 90
Suelo al Grados
Al
Alero Ménsulas y
Tablas
Contra
Deslizamiento

OR-OSHA – PESO TOOLBOX SHEET HOJA INFORMATIVA DE OR-OSHA – PESO


1 (800) 922-2689 or visit www.orosha.org 1 (800) 843-8086 opción No. 3 ó visite www.orosha.org

También podría gustarte