.15 Sobrecimiento N.P.T. = +0.

10
A B C f'c=140 Kg/cm2
.20
5.56 5.56 N.P.T.= +0.10 N.P.T.= +0.10
1.60 3.36 1.60 3.36 1.60 .25

3
3
.20 Ø 3/8" @ 0.20
C-1 C-1 C-1 .30 5Ø1/2"
3 3 Ø 3/8" @ 0.20
f'c=210Kg/cm2

ESCALERA
CIMIENTO
.40
1.10 Ø1/4":1@.05,5@.10

1.60
1.60

3
3
C:H 1:10+30%P.G. r@0.25
.80 .60 Cimiento
Ø 1/2" @ 0.20
Z-1 Z-1 Z-1 .45 C:H 1:10+30%P.G.
Ø 3/8" @ 0.20
h=0.45 4 4 Cimiento
h=0.45 h=0.45 SOLADO Ø 1/2" @ 0.20
.10 SOLADO
.45 .10 VIGA PORTANTE

3.94
3 3 .50 V-101
3.95

3 3 1 1 4 SECCION 4-4
SECCION 2-2

1.69
1.70

0.15 1.06 Ø 3/8" @ 0.20

Ø 3/8" @ 0.20

CIMIENTO
ESCALERA 4 Ø 1/2" @ 0.20
TRAMO 2
ESC.: 1/25
0.15

2 2 Ø 1/2" @ 0.20
.15
.15

1.60
1.60

2 C-1 C-1 C-1 2 Sobrecimiento


Sobrecimiento
f'c=140 Kg/cm2
f'c=140 Kg/cm2 N.P.T. = +0.10
Z-1 2 Z-1 2 Z-1 N.P.T. = +0.10
h=0.45 h=0.45 h=0.45
.20
.20 .55
.55
.25
.25

2.84
5Ø1/2"
1.70

3 3 5Ø1/2" 0.15 1.04

1.89
3 3 f'c=210Kg/cm2
1 1 f'c=210Kg/cm2 .40
3.95

.40 Ø1/4":1@.05,5@.10
1.10 Ø 3/8" @ 0.20
1.10 Ø1/4":1@.05,5@.10 r@0.25 0.30
r@0.25
0.30
0.15
.45 C:H 1:10+30%P.G.
Z-1 .45 C:H 1:10+30%P.G. Cimiento
1' Cimiento
h=0.45 C-2
SOLADO Ø 1/2" @ 0.20
Z-2
1.60

SOLADO .10
h=0.45 .10
.60

1.48
3

1.83
.60
Z-1 3
h=0.45 SECCION 1-1
1 C-1 SECCION 3-3
C-2 Ø 3/8" @ 0.20 0.30
1.60 C-1
2.80 3 1.60
1
3 2.94
2.03
5.00
TRAMO 1
3.89 ESC.: 1/25
1.73
B
B 2.00
C' C
1.60 TRAMO 1
CIMENTACIÓN ESC.: 1/25
0.70
ESCALA: 1/50 Ø 1/2" @ 0.20

CUADRO DE COLUMNAS SOLADO 0.10


ESC: 1/25 .30 0.50

C1 C2

9Ø1/2"
DETALLE DE REFUERZO EN ESCALERA 1º NIVEL
Según cuadro
de columnas

8Ø1/2"
8 Ø5/8" 6 Ø5/8" 1.80
1.60
Ø3/8": 1@.05, Ø3/8": 1@.05,
6@.10, 2@.15, r@.25 6@.10, 2@.15, r@.25
c/extremo c/extremo
0.40 N.P.T. +0.10
0.30
N.V.T. +0.00
3Ø5/8"
0.30 2Ø5/8" 6 Ø5/8" .55
10Ø1/2" 8Ø1/2"
3Ø5/8"
PLANTA DE ZAPATA Z-2 PLANTA DE ZAPATA Z-1
8 Ø5/8" 6 Ø5/8" Ø1/4":1@.05,5@.10
r@0.25 5 Ø 1/2"
f'c=210Kg/cm2 .40
f´c= 210 kg/cm2 f´c= 210 kg/cm2
Viga Cimentacion DETALLE DE ZAPATAS Z-1, Z-2 y Z-3
f'c=210Kg/cm2 ESC.: 1/25
ZAPATA
.45
.25 .25
0.25 0.25 Espaciamiento de refuerzo dentro de Nudos
Tip. Tip. (S = 0.15) LONGITUD DE ANCLAJE CON GANCHO (ldg) cm.
Solado 1:10 C:H , e= 4" .10
S = 0.15 Afirmado .10 f'c
Ø 175 Kg/cm2 210 Kg/cm2 280 Kg/cm2 RECUBRIMIENTO Ø DE COLUMNA
Over 3" - 4" .20 1/2" 30 28 24
l dg Ø DE VIGA
5/8" 38 35 30
Variable
h/6 r 3/4" 46 42 36 45°
a

RECUBRIMIENTO
PERFIL 1" 61 56 49
Ø Estrib. D a
DETALLE DE ZAPATAS
Extensión de D
12 db
ESC.:1/25
EXTENSION RECTA 12db RADIO MINIMO . 1/4" 3 cm 8 cm
EMPALMAR EN DIFERENTES Ø
1/2'' 15 cm DE DOBLEZ (r)
PARTES, TRATANDO DE HACER
5/8'' 20 cm
3/8" 4 cm 12 cm
LOS EMPALMES FUERA DE LA 3/8" 3.00 cm
ZONA DE CONFINAMIENTO 3/4" 25 cm
1/2" 4.00 cm 45°
1" 31 cm
L 2h/3 Ø DE COLUMNA 5/8" 5.00 cm
GANCHOS ESTANDAR
Ø L 3/4" 6.00 cm
VIGA Ø DE VIGAS
EN ESTRIBOS
LONGITUD DE ANCLAJE CON GANCHOS 1" 8.00 cm
3/8" 0.25
1/2" 0.25
5/8" 0.30
L ESPECIFICACIONES TECNICAS
3/4" 0.30
h/6
CONCRETO
ANCLAJE TIPICO
COLUMNAS f'c = 210 kg/cm2
DE COLUMNAS COLUMNETAS f'c = 175 kg/cm2
0.08
S = 0.15 VIGAS f'c = 210 kg/cm2
VIGA DE CIMENTACION f'c = 210 kg/cm2
2 Alambres # 8 ZAPATAS f'c = 210 kg/cm2
C/3 Hiladas (Corrido) SOBRECIMIENTO SIMPLE f'c = 140 kg/cm2
SOLADO f'c = 100 kg/cm2 0.23
CIMIENTO CORRIDO 1:10 + 30% P.G. 0.13

ACERO EDIFICIO: COMERCIO - OFICINA COORPORATIVAS


LONGITUD DE EMPALME (L) LONGITUD DE EMPALME (L) ACERO DE REFUERZO GRADO 60 fy = 4200kg/cm2
NOTAS: TIPO DE LADRILLO DEPARTAMENTO: CAJAMARCA
Ø 3/8" 0.35 Ø 3/8" 0.40 RECUBRIMIENTO JR. LEONES - CAJAMARCA

1.- Los muros portantes podrán ser de ladrillos de Arcilla,

C-01
Ø 1/2" 0.40 VIGAS Y COLUMNAS 3.00 cm.
Ø 1/2" 0.50 ZAPATAS 5.00 cm. bien quemado, color y textura uniformes
deberán tener las dimensiones especificadas
Ø 5/8" 0.45 Ø 5/8" 0.60 LOSAS 3.00 cm.
(0.23x0.13x0.08)
Ø 3/4" 0.55 Ø 3/4" 0.70 2.- En caso de usarse Bloque de concreto macizo, estos
ALBAÑILERIA deberán ser vibrados y serán preparadas con CIMENTACION
Ø 1" 1.00 Ø 1" 1.30 VIGA DE CIMENTACION Concreto de f'c=140 Kg/cm2.
fm = 45 kg/cm2 (Ladrillo king-kong)
Ver Notas 1 y 2 3.- Los muros tendrán 2 alambres # 8 cada 3 hiladas,
CONSIDERANDO ZONA DE CONSIDERANDO ZONA DE ESFUERZOS corridos entre eje de columna y ancladas en las
mismas.
ESFUERZOS BAJOS ALTOS, PERO QUE SE EMPALMAN DETALLE ALAMBRE DE REFUERZO EN MUROS TIPO DE MORTERO
MENOS DEL 50% DE LAS VARILLAS
SRA. LAURA RABANAL MURRUGARRA
ELEVACION TIPICA DE COLUMNAS Mortero 1:5 (Cemento : Arena)

EMPALMES TRASLAPADOS PARA COLUMNAS INDICADA E.S.I. SETIEMBRE 2021