Está en la página 1de 22

RESUMEN DE LOS RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13
PROCESO: GEOLOGIA Y DISEÑO GEOTÉCNICO

PROYECTO: TALUD CHARALA

LIMITES DE ATTERBERG GRADACION


SONDEO PROF (m) USCS WN %
LL % LP % IP % G% A% F%
S1-M1 0.00 - 1.00 ML 22.64 34.79 34.28 0.51 0.16 22.96 76.88
S1-M2 1.00 - 3.00 ML 16.20 NP NP NP 12.72 28.08 59.20
S1-M3 3.00 - 5.00 ML 14.84 NP NP NP 12.80 33.48 53.72
S2-M1 0.00 - 1.00 SM 27.68 NP NP NP 6.92 49.00 44.08
S2-M2 1.00 - 2.00 SM 26.78 NP NP NP 7.76 46.16 46.08
S3-M1 0.00 - 1.00 SM 18.15 41.43 32.42 9.02 30.08 39.64 30.28
S3-M2 1.00 - 3.00 SM 17.26 43.34 32.79 10.55 20.84 30.24 48.92
S4-M1 0.00 - 2.00 SC 8.59 27.37 19.57 7.80 23.28 30.52 46.20
S5-M1 0.00 - 1.00 CL 19.15 35.98 20.17 15.81 10.08 37.52 52.40
S5-M2 1.00 - 3.00 CL 23.70 28.77 20.67 8.10 10.48 30.76 58.76
S6-M1 0.00 - 1.00 SM 15.57 NP NP NP 17.28 49.00 33.72
S7-M1 0.00 - 1.00 SM 16.41 34.41 31.20 3.21 23.72 37.08 39.20
S8-M1 0.00 - 1.00 GM 13.67 NP NP NP 50.76 35.32 13.92
S8-M2 1.00 - 2.00 SM 8.54 NP NP NP 36.48 24.92 38.60
S9-M1 0.00 - 1.00 SM-SC 23.91 21.80 16.82 4.98 6.24 45.96 47.80
S9-M2 1.00 - 2.00 SM 12.75 NP NP NP 0.84 65.84 33.32
S10-M1 0.00 - 1.00 SM 7.43 NP NP NP 33.92 46.68 19.40
S11-M1 0.00 - 1.00 ML 21.56 NP NP NP 8.32 37.60 54.08
S11-M2 1.00 - 2.00 SM 10.53 NP NP NP 15.16 43.28 41.56
S12-M1 0.00 - 1.00 SC 19.85 32.22 19.69 12.52 9.12 44.92 45.96
S12-M2 1.00 - 2.00 SM 17.23 38.52 31.10 7.43 28.12 33.20 38.68
Valores Máximos 27.68 43.34 34.28 15.81 50.76 65.84 76.88
Valores Promedios 17.26 33.86 25.87 7.99 17.38 38.67 43.94
Valores Mínimos 7.43 21.80 16.82 0.51 0.16 22.96 13.92
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/1/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 265

W Tara + S. Hum (g) 537.6 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 451.2 SONDEO S1

w tara (g) 69.6 PROFUNDIDAD (m) 0.00 - 1.00


W S. Seco (g) 381.6 MUESTRA M-1
W Agua (g) 86.4

Humedad % 22.64 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No. 88 113 505

No. mm grs grs Retenido Que pasa W Tara + S. Hum 29.15 30.27 31.39

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec 23.61 24.70 25.79

21/2 62.5 0.00 0.00 0.00 100.00 W Tara 8.67 8.77 8.76

2.0 50 0.00 0.00 0.00 100.00 W S. Seco 14.94 15.93 17.03

11/2 37.5 0.00 0.00 0.00 100.00 W Agua 5.54 5.57 5.60

1" 25 0.00 0.00 0.00 100.00 Humedad % 37.08 34.97 32.88

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes 17 24 32

1/2 12.5 0.00 0.00 0.00 100.00

3/8 9.5 0.00 0.00 0.00 100.00 LIMITE PLASTICO (INV E-126-13)

4 4.76 0.80 0.80 0.16 99.84 Tara No. 18 56

10 2 8.40 9.20 1.68 98.16 W Tara + S. Hum 21.46 20.32

20 1.25 10.80 20.00 2.16 96.00 W Tara + S. Sec 18.24 17.29

40 0.43 20.00 40.00 4.00 92.00 W Tara 8.67 8.61

100 0.15 54.20 94.20 10.84 81.16 W S. Seco 9.57 8.68

200 0.07 21.40 115.60 4.28 76.88 W Agua 3.22 3.03

Pasa 200 384.40 500.00 76.88 0.00 Humedad % 33.65 34.91

P1 500.00 grs

110.00 38.00
100.00 f(x) = 2.91000885197933 ln(x) + 91.007719350849
37.00
90.00 f(x) = − 0.279436696625224 x + 41.7763867207855

80.00 36.00

70.00 35.00
Humedad %
% que pasa

60.00
34.00
50.00

40.00 33.00

30.00 32.00
20.00
31.00
10.00

0.00 30.00
100 10 1 0.1 0.01 10 Numero de golpes 100

Diámetro que pasa (mm)

GRAVA 0.16 D10 NP Cc NP LIMITE LIQUIDO 34.79

ARENA 22.96 D30 NP Cu NP LIMITE PLASTICO 34.28

FINOS 76.88 D60 NP INDICE PLASTICO 0.51

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


ML LIMOS INORGANICOS DE MEDIANA COMPRESIBILIDAD
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/1/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 424

W Tara + S. Hum (g) 1151.0 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 999.4 SONDEO S1

w tara (g) 63.6 PROFUNDIDAD (m) 1.00 - 3.00


W S. Seco (g) 935.8 MUESTRA M-2
W Agua (g) 151.6

Humedad % 16.20 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No.

No. mm grs grs Retenido Que pasa W Tara + S. Hum

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec

21/2 62.5 0.00 0.00 0.00 100.00 W Tara

2.0 50 0.00 0.00 0.00 100.00 W S. Seco

11/2 37.5 0.00 0.00 0.00 100.00 W Agua

1" 25 0.00 0.00 0.00 100.00 Humedad %

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes NP NP NP

1/2 12.5 34.40 34.40 6.88 93.12

3/8 9.5 17.40 51.80 3.48 89.64 LIMITE PLASTICO (INV E-126-13)

4 4.76 11.80 63.60 2.36 87.28 Tara No.

10 2 19.80 83.40 3.96 83.32 W Tara + S. Hum

20 1.25 13.40 96.80 2.68 80.64 W Tara + S. Sec

40 0.43 20.20 117.00 4.04 76.60 W Tara

100 0.15 64.60 181.60 12.92 63.68 W S. Seco

200 0.07 22.40 204.00 4.48 59.20 W Agua

Pasa 200 296.00 500.00 59.20 0.00 Humedad % NP NP

P1 500.00 grs

110.00

100.00 f(x) = 5.9868375783673 ln(x) + 77.8290862191102

90.00

80.00

70.00
% que pasa

60.00

50.00

40.00

30.00

20.00

10.00

0.00
100 10 1 0.1 0.01
Diámetro que pasa (mm)

GRAVA 12.72 D10 NP Cc NP LIMITE LIQUIDO NP

ARENA 28.08 D30 NP Cu NP LIMITE PLASTICO NP

FINOS 59.20 D60 0.085 INDICE PLASTICO NP

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


ML LIMOS INORGANICOS DE BAJA COMPRESIBILIDAD
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/1/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 409

W Tara + S. Hum (g) 884.4 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 778.6 SONDEO S1

w tara (g) 65.6 PROFUNDIDAD (m) 3.00 - 5.00


W S. Seco (g) 713 MUESTRA M-3
W Agua (g) 105.8

Humedad % 14.84 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No.

No. mm grs grs Retenido Que pasa W Tara + S. Hum

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec

21/2 62.5 0.00 0.00 0.00 100.00 W Tara

2.0 50 0.00 0.00 0.00 100.00 W S. Seco

11/2 37.5 0.00 0.00 0.00 100.00 W Agua

1" 25 0.00 0.00 0.00 100.00 Humedad %

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes NP NP NP

1/2 12.5 39.20 39.20 7.84 92.16

3/8 9.5 14.20 53.40 2.84 89.32 LIMITE PLASTICO (INV E-126-13)

4 4.76 10.60 64.00 2.12 87.20 Tara No.

10 2 22.80 86.80 4.56 82.64 W Tara + S. Hum

20 1.25 15.00 101.80 3.00 79.64 W Tara + S. Sec

40 0.43 24.80 126.60 4.96 74.68 W Tara

100 0.15 78.40 205.00 15.68 59.00 W S. Seco

200 0.07 26.40 231.40 5.28 53.72 W Agua

Pasa 200 268.60 500.00 53.72 0.00 Humedad % NP NP

P1 500.00 grs

110.00

100.00 f(x) = 6.67984447763575 ln(x) + 75.5595142525838

90.00

80.00

70.00
% que pasa

60.00

50.00

40.00

30.00

20.00

10.00

0.00
100 10 1 0.1 0.01
Diámetro que pasa (mm)

GRAVA 12.80 D10 NP Cc NP LIMITE LIQUIDO NP

ARENA 33.48 D30 NP Cu NP LIMITE PLASTICO NP

FINOS 53.72 D60 0.17 INDICE PLASTICO NP

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


ML LIMOS INORGANICOS DE BAJA COMPRESIBILIDAD
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/2/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 378

W Tara + S. Hum (g) 983.0 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 785.6 SONDEO S2

w tara (g) 72.4 PROFUNDIDAD (m) 0.00 - 1.00


W S. Seco (g) 713.2 MUESTRA M-1
W Agua (g) 197.4

Humedad % 27.68 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No.

No. mm grs grs Retenido Que pasa W Tara + S. Hum

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec

21/2 62.5 0.00 0.00 0.00 100.00 W Tara

2.0 50 0.00 0.00 0.00 100.00 W S. Seco

11/2 37.5 0.00 0.00 0.00 100.00 W Agua

1" 25 0.00 0.00 0.00 100.00 Humedad %

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes NP NP NP

1/2 12.5 0.00 0.00 0.00 100.00

3/8 9.5 15.40 15.40 3.08 96.92 LIMITE PLASTICO (INV E-126-13)

4 4.76 19.20 34.60 3.84 93.08 Tara No.

10 2 29.20 63.80 5.84 87.24 W Tara + S. Hum

20 1.25 30.00 93.80 6.00 81.24 W Tara + S. Sec

40 0.43 41.20 135.00 8.24 73.00 W Tara

100 0.15 122.60 257.60 24.52 48.48 W S. Seco

200 0.07 22.00 279.60 4.40 44.08 W Agua

Pasa 200 220.40 500.00 44.08 0.00 Humedad % NP NP

P1 500.00 grs

110.00
f(x) = 7.95938584877015 ln(x) + 73.7688484637
100.00

90.00

80.00

70.00
% que pasa

60.00

50.00

40.00

30.00

20.00

10.00

0.00
100 10 1 0.1 0.01
Diámetro que pasa (mm)

GRAVA 6.92 D10 NP Cc NP LIMITE LIQUIDO NP

ARENA 49.00 D30 NP Cu NP LIMITE PLASTICO NP

FINOS 44.08 D60 0.25 INDICE PLASTICO NP

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SM ARENAS LIMOSAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/2/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 4

W Tara + S. Hum (g) 557.4 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 454.6 SONDEO S2

w tara (g) 70.8 PROFUNDIDAD (m) 1.00 - 2.00


W S. Seco (g) 383.8 MUESTRA M-2
W Agua (g) 102.8

Humedad % 26.78 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No.

No. mm grs grs Retenido Que pasa W Tara + S. Hum

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec

21/2 62.5 0.00 0.00 0.00 100.00 W Tara

2.0 50 0.00 0.00 0.00 100.00 W S. Seco

11/2 37.5 0.00 0.00 0.00 100.00 W Agua

1" 25 0.00 0.00 0.00 100.00 Humedad %

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes NP NP NP

1/2 12.5 0.00 0.00 0.00 100.00

3/8 9.5 14.20 14.20 2.84 97.16 LIMITE PLASTICO (INV E-126-13)

4 4.76 24.60 38.80 4.92 92.24 Tara No.

10 2 49.00 87.80 9.80 82.44 W Tara + S. Hum

20 1.25 34.20 122.00 6.84 75.60 W Tara + S. Sec

40 0.43 35.00 157.00 7.00 68.60 W Tara

100 0.15 99.60 256.60 19.92 48.68 W S. Seco

200 0.07 13.00 269.60 2.60 46.08 W Agua

Pasa 200 230.40 500.00 46.08 0.00 Humedad % NP NP

P1 500.00 grs

110.00
f(x) = 8.18596215414456 ln(x) + 72.434207572151
100.00

90.00

80.00

70.00
% que pasa

60.00

50.00

40.00

30.00

20.00

10.00

0.00
100 10 1 0.1 0.01
Diámetro que pasa (mm)

GRAVA 7.76 D10 NP Cc NP LIMITE LIQUIDO NP

ARENA 46.16 D30 NP Cu NP LIMITE PLASTICO NP

FINOS 46.08 D60 0.28 INDICE PLASTICO NP

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SM ARENAS LIMOSAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/3/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 374

W Tara + S. Hum (g) 640.4 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 552.8 SONDEO S3

w tara (g) 70.2 PROFUNDIDAD (m) 0.00 - 1.00


W S. Seco (g) 482.6 MUESTRA M-1
W Agua (g) 87.6

Humedad % 18.15 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No. 9 42 98

No. mm grs grs Retenido Que pasa W Tara + S. Hum 27.20 28.32 29.45

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec 21.45 22.54 23.67

21/2 62.5 0.00 0.00 0.00 100.00 W Tara 8.76 8.67 8.56

2.0 50 0.00 0.00 0.00 100.00 W S. Seco 12.69 13.87 15.11

11/2 37.5 0.00 0.00 0.00 100.00 W Agua 5.75 5.78 5.78

1" 25 0.00 0.00 0.00 100.00 Humedad % 45.31 41.67 38.25

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes 17 24 32

1/2 12.5 84.00 84.00 16.80 83.20

3/8 9.5 35.80 119.80 7.16 76.04 LIMITE PLASTICO (INV E-126-13)

4 4.76 30.60 150.40 6.12 69.92 Tara No. 5 504

10 2 49.40 199.80 9.88 60.04 W Tara + S. Hum 22.64 21.38

20 1.25 38.80 238.60 7.76 52.28 W Tara + S. Sec 19.26 18.21

40 0.43 38.80 277.40 7.76 44.52 W Tara 8.67 8.58

100 0.15 55.60 333.00 11.12 33.40 W S. Seco 10.59 9.63

200 0.07 15.60 348.60 3.12 30.28 W Agua 3.38 3.17

Pasa 200 151.40 500.00 30.28 0.00 Humedad % 31.92 32.92

P1 500.00 grs

110.00 46.00
100.00 f(x) = 11.4603665045028 ln(x) + 55.3050000050794
f(x) = − 0.469544066042974 x + 53.1711576937524
90.00 44.00

80.00
42.00
70.00
Humedad %
% que pasa

60.00
40.00
50.00

40.00
38.00
30.00

20.00 36.00
10.00

0.00 34.00
100 10 1 0.1 0.01 10 Numero de golpes 100

Diámetro que pasa (mm)

GRAVA 30.08 D10 NP Cc NP LIMITE LIQUIDO 41.43

ARENA 39.64 D30 0.07 Cu NP LIMITE PLASTICO 32.42

FINOS 30.28 D60 2 INDICE PLASTICO 9.02

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SM ARENAS LIMOSAS CON GRAVAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/3/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 488

W Tara + S. Hum (g) 1236 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 1063.8 SONDEO S3

w tara (g) 66.2 PROFUNDIDAD (m) 1.00 - 3.00


W S. Seco (g) 997.6 MUESTRA M-2
W Agua (g) 172.2

Humedad % 17.26 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No. 80 20 40

No. mm grs grs Retenido Que pasa W Tara + S. Hum 28.32 29.45 30.59

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec 22.07 23.17 24.28

21/2 62.5 0.00 0.00 0.00 100.00 W Tara 8.67 8.73 8.77

2.0 50 0.00 0.00 0.00 100.00 W S. Seco 13.40 14.44 15.51

11/2 37.5 0.00 0.00 0.00 100.00 W Agua 6.25 6.28 6.31

1" 25 0.00 0.00 0.00 100.00 Humedad % 46.64 43.49 40.68

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes 17 24 32

1/2 12.5 53.20 53.20 10.64 89.36

3/8 9.5 26.20 79.40 5.24 84.12 LIMITE PLASTICO (INV E-126-13)

4 4.76 24.80 104.20 4.96 79.16 Tara No. 94 79

10 2 29.40 133.60 5.88 73.28 W Tara + S. Hum 20.29 19.20

20 1.25 21.40 155.00 4.28 69.00 W Tara + S. Sec 17.52 16.48

40 0.43 21.80 176.80 4.36 64.64 W Tara 8.59 8.61

100 0.15 47.00 223.80 9.40 55.24 W S. Seco 8.93 7.87

200 0.07 31.60 255.40 6.32 48.92 W Agua 2.77 2.72

Pasa 200 244.60 500.00 48.92 0.00 Humedad % 31.02 34.56

P1 500.00 grs

110.00 48.00
100.00 f(x) = 7.88701243151962 ln(x) + 69.5845086818465
90.00 46.00 f(x) = − 0.396126676497563 x + 53.2442577277906

80.00
44.00
70.00
Humedad %
% que pasa

60.00
42.00
50.00

40.00
40.00
30.00

20.00 38.00
10.00

0.00 36.00
100 10 1 0.1 0.01 10 Numero de golpes 100

Diámetro que pasa (mm)

GRAVA 20.84 D10 NP Cc NP LIMITE LIQUIDO 43.34

ARENA 30.24 D30 NP Cu NP LIMITE PLASTICO 32.79

FINOS 48.92 D60 0.26 INDICE PLASTICO 10.55

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SM ARENAS LIMOSAS CON GRAVAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/2/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 25

W Tara + S. Hum (g) 1026.2 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 950.6 SONDEO S4

w tara (g) 70.8 PROFUNDIDAD (m) 0.00 - 2.00


W S. Seco (g) 879.8 MUESTRA M-1
W Agua (g) 75.6

Humedad % 8.59 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No. 355 44 41

No. mm grs grs Retenido Que pasa W Tara + S. Hum 27.22 28.33 29.46

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec 23.00 24.09 25.15

21/2 62.5 0.00 0.00 0.00 100.00 W Tara 8.68 8.47 8.55

2.0 50 0.00 0.00 0.00 100.00 W S. Seco 14.32 15.62 16.60

11/2 37.5 0.00 0.00 0.00 100.00 W Agua 4.22 4.24 4.31

1" 25 0.00 0.00 0.00 100.00 Humedad % 29.47 27.14 25.96

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes 17 24 32

1/2 12.5 0.00 0.00 0.00 100.00

3/8 9.5 62.20 62.20 12.44 87.56 LIMITE PLASTICO (INV E-126-13)

4 4.76 54.20 116.40 10.84 76.72 Tara No. 84 82

10 2 65.40 181.80 13.08 63.64 W Tara + S. Hum 21.67 20.38

20 1.25 34.20 216.00 6.84 56.80 W Tara + S. Sec 19.53 18.50

40 0.43 20.00 236.00 4.00 52.80 W Tara 8.68 8.82

100 0.15 23.80 259.80 4.76 48.04 W S. Seco 10.85 9.68

200 0.07 9.20 269.00 1.84 46.20 W Agua 2.14 1.88

Pasa 200 231.00 500.00 46.20 0.00 Humedad % 19.72 19.42

P1 500.00 grs

110.00 30.00
100.00 f(x) = 9.46489892709871 ln(x) + 64.5931510269701

90.00 29.00 f(x) = − 0.231656905169198 x + 33.162923180557

80.00
28.00
70.00
Humedad %
% que pasa

60.00
27.00
50.00

40.00
26.00
30.00

20.00 25.00
10.00

0.00 24.00
100 10 1 0.1 0.01 10 Numero de golpes 100

Diámetro que pasa (mm)

GRAVA 23.28 D10 NP Cc NP LIMITE LIQUIDO 27.37

ARENA 30.52 D30 NP Cu NP LIMITE PLASTICO 19.57

FINOS 46.20 D60 1.7 INDICE PLASTICO 7.80

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SC ARENAS ARCILLOSAS CON GRAVAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/1/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 300

W Tara + S. Hum (g) 878.6 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 746.8 SONDEO S5

w tara (g) 58.4 PROFUNDIDAD (m) 0.00 - 1.00


W S. Seco (g) 688.4 MUESTRA M-1
W Agua (g) 131.8

Humedad % 19.15 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No. 78 47 48

No. mm grs grs Retenido Que pasa W Tara + S. Hum 27.45 28.58 29.69

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec 22.19 23.30 24.39

21/2 62.5 0.00 0.00 0.00 100.00 W Tara 8.61 8.66 8.71

2.0 50 0.00 0.00 0.00 100.00 W S. Seco 13.58 14.64 15.68

11/2 37.5 0.00 0.00 0.00 100.00 W Agua 5.26 5.28 5.30

1" 25 0.00 0.00 0.00 100.00 Humedad % 38.73 36.07 33.80

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes 17 24 32

1/2 12.5 0.00 0.00 0.00 100.00

3/8 9.5 29.40 29.40 5.88 94.12 LIMITE PLASTICO (INV E-126-13)

4 4.76 21.00 50.40 4.20 89.92 Tara No. 37 77

10 2 24.60 75.00 4.92 85.00 W Tara + S. Hum 19.76 18.56

20 1.25 20.80 95.80 4.16 80.84 W Tara + S. Sec 17.88 16.89

40 0.43 33.40 129.20 6.68 74.16 W Tara 8.55 8.62

100 0.15 81.80 211.00 16.36 57.80 W S. Seco 9.33 8.27

200 0.07 27.00 238.00 5.40 52.40 W Agua 1.88 1.67

Pasa 200 262.00 500.00 52.40 0.00 Humedad % 20.15 20.19

P1 500.00 grs

110.00 40.00
100.00 f(x) = 6.91136669535218 ln(x) + 76.2963835196246
39.00
90.00 f(x) = − 0.327744372057227 x + 44.1751216185897
38.00
80.00
37.00
70.00
Humedad %
% que pasa

60.00 36.00

50.00 35.00
40.00
34.00
30.00
33.00
20.00
32.00
10.00

0.00 31.00
100 10 1 0.1 0.01 10 Numero de golpes 100

Diámetro que pasa (mm)

GRAVA 10.08 D10 NP Cc NP LIMITE LIQUIDO 35.98

ARENA 37.52 D30 NP Cu NP LIMITE PLASTICO 20.17

FINOS 52.40 D60 0.19 INDICE PLASTICO 15.81

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


CL ARCILLAS INORGANICAS DE MEDIANA PLASTICIDAD
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/1/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 358

W Tara + S. Hum (g) 1350.8 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 1105.4 SONDEO S5

w tara (g) 69.8 PROFUNDIDAD (m) 1.00 - 3.00


W S. Seco (g) 1035.6 MUESTRA M-2
W Agua (g) 245.4

Humedad % 23.70 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No. 7 92 39

No. mm grs grs Retenido Que pasa W Tara + S. Hum 28.29 29.43 30.57

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec 23.67 24.76 25.82

21/2 62.5 0.00 0.00 0.00 100.00 W Tara 8.48 8.47 8.51

2.0 50 0.00 0.00 0.00 100.00 W S. Seco 15.19 16.29 17.31

11/2 37.5 0.00 0.00 0.00 100.00 W Agua 4.62 4.67 4.75

1" 25 0.00 0.00 0.00 100.00 Humedad % 30.41 28.67 27.44

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes 18 24 32

1/2 12.5 0.00 0.00 0.00 100.00

3/8 9.5 35.80 35.80 7.16 92.84 LIMITE PLASTICO (INV E-126-13)

4 4.76 16.60 52.40 3.32 89.52 Tara No. 33 38

10 2 18.00 70.40 3.60 85.92 W Tara + S. Hum 20.43 19.37

20 1.25 13.20 83.60 2.64 83.28 W Tara + S. Sec 18.45 17.50

40 0.43 18.20 101.80 3.64 79.64 W Tara 8.71 8.60

100 0.15 77.80 179.60 15.56 64.08 W S. Seco 9.74 8.90

200 0.07 26.60 206.20 5.32 58.76 W Agua 1.98 1.87

Pasa 200 293.80 500.00 58.76 0.00 Humedad % 20.33 21.01

P1 500.00 grs

110.00 31.00
100.00 f(x) = 5.88406661362013 ln(x) + 79.4740678086268

90.00 30.00 f(x) = − 0.209234577353402 x + 34.0022617849009

80.00
29.00
70.00
Humedad %
% que pasa

60.00
28.00
50.00

40.00
27.00
30.00

20.00 26.00
10.00

0.00 25.00
100 10 1 0.1 0.01 10 Numero de golpes 100

Diámetro que pasa (mm)

GRAVA 10.48 D10 NP Cc NP LIMITE LIQUIDO 28.77

ARENA 30.76 D30 NP Cu NP LIMITE PLASTICO 20.67

FINOS 58.76 D60 0.09 INDICE PLASTICO 8.10

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


CL ARCILLAS INORGANICAS DE BAJA PLASTICIDAD
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/3/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 370

W Tara + S. Hum (g) 820.4 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 718.8 SONDEO S6

w tara (g) 66.2 PROFUNDIDAD (m) 0.00 - 1.00


W S. Seco (g) 652.6 MUESTRA M-1
W Agua (g) 101.6

Humedad % 15.57 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No.

No. mm grs grs Retenido Que pasa W Tara + S. Hum

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec

21/2 62.5 0.00 0.00 0.00 100.00 W Tara

2.0 50 0.00 0.00 0.00 100.00 W S. Seco

11/2 37.5 0.00 0.00 0.00 100.00 W Agua

1" 25 0.00 0.00 0.00 100.00 Humedad %

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes NP NP NP

1/2 12.5 0.00 0.00 0.00 100.00

3/8 9.5 48.20 48.20 9.64 90.36 LIMITE PLASTICO (INV E-126-13)

4 4.76 38.20 86.40 7.64 82.72 Tara No.

10 2 48.80 135.20 9.76 72.96 W Tara + S. Hum

20 1.25 29.80 165.00 5.96 67.00 W Tara + S. Sec

40 0.43 33.80 198.80 6.76 60.24 W Tara

100 0.15 108.20 307.00 21.64 38.60 W S. Seco

200 0.07 24.40 331.40 4.88 33.72 W Agua

Pasa 200 168.60 500.00 33.72 0.00 Humedad % NP NP

P1 500.00 grs

110.00
f(x) = 10.1343500805975 ln(x) + 64.4325847976026
100.00

90.00

80.00

70.00
% que pasa

60.00

50.00

40.00

30.00

20.00

10.00

0.00
100 10 1 0.1 0.01
Diámetro que pasa (mm)

GRAVA 17.28 D10 NP Cc NP LIMITE LIQUIDO NP

ARENA 49.00 D30 NP Cu NP LIMITE PLASTICO NP

FINOS 33.72 D60 0.43 INDICE PLASTICO NP

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SM ARENAS LIMOSAS CON GRAVAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/3/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 351

W Tara + S. Hum (g) 786 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 685.2 SONDEO S7

w tara (g) 71 PROFUNDIDAD (m) 0.00 - 1.00


W S. Seco (g) 614.2 MUESTRA M-1
W Agua (g) 100.8

Humedad % 16.41 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No. 40 50 67

No. mm grs grs Retenido Que pasa W Tara + S. Hum 28.36 29.48 30.60

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec 23.02 24.10 25.17

21/2 62.5 0.00 0.00 0.00 100.00 W Tara 8.56 8.46 8.46

2.0 50 0.00 0.00 0.00 100.00 W S. Seco 14.46 15.64 16.71

11/2 37.5 0.00 0.00 0.00 100.00 W Agua 5.34 5.38 5.43

1" 25 0.00 0.00 0.00 100.00 Humedad % 36.93 34.40 32.50

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes 17 24 32

1/2 12.5 52.40 52.40 10.48 89.52

3/8 9.5 38.20 90.60 7.64 81.88 LIMITE PLASTICO (INV E-126-13)

4 4.76 28.00 118.60 5.60 76.28 Tara No. 73 19

10 2 32.60 151.20 6.52 69.76 W Tara + S. Hum 20.36 19.31

20 1.25 22.00 173.20 4.40 65.36 W Tara + S. Sec 17.71 16.63

40 0.43 32.40 205.60 6.48 58.88 W Tara 8.58 8.60

100 0.15 79.40 285.00 15.88 43.00 W S. Seco 9.13 8.03

200 0.07 19.00 304.00 3.80 39.20 W Agua 2.65 2.68

Pasa 200 196.00 500.00 39.20 0.00 Humedad % 29.03 33.37

P1 500.00 grs

110.00 38.00
100.00 f(x) = 9.50583563380438 ln(x) + 63.9600245134178
37.00
90.00 f(x) = − 0.294231779171675 x + 41.7676230374004
80.00 36.00

70.00 35.00
Humedad %
% que pasa

60.00
34.00
50.00

40.00 33.00

30.00 32.00
20.00
31.00
10.00

0.00 30.00
100 10 1 0.1 0.01 10 Numero de golpes 100

Diámetro que pasa (mm)

GRAVA 23.72 D10 NP Cc NP LIMITE LIQUIDO 34.41

ARENA 37.08 D30 NP Cu NP LIMITE PLASTICO 31.20

FINOS 39.20 D60 0.5 INDICE PLASTICO 3.21

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SM ARENAS LIMOSAS CON GRAVAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/2/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 10

W Tara + S. Hum (g) 845.2 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 750.6 SONDEO S8

w tara (g) 58.4 PROFUNDIDAD (m) 0.00 - 1.00


W S. Seco (g) 692.2 MUESTRA M-1
W Agua (g) 94.6

Humedad % 13.67 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No.

No. mm grs grs Retenido Que pasa W Tara + S. Hum

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec

21/2 62.5 0.00 0.00 0.00 100.00 W Tara

2.0 50 0.00 0.00 0.00 100.00 W S. Seco

11/2 37.5 0.00 0.00 0.00 100.00 W Agua

1" 25 0.00 0.00 0.00 100.00 Humedad %

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes NP NP NP

1/2 12.5 148.20 148.20 29.64 70.36

3/8 9.5 61.20 209.40 12.24 58.12 LIMITE PLASTICO (INV E-126-13)

4 4.76 44.40 253.80 8.88 49.24 Tara No.

10 2 45.60 299.40 9.12 40.12 W Tara + S. Hum

20 1.25 32.60 332.00 6.52 33.60 W Tara + S. Sec

40 0.43 32.80 364.80 6.56 27.04 W Tara

100 0.15 55.20 420.00 11.04 16.00 W S. Seco

200 0.07 10.40 430.40 2.08 13.92 W Agua

Pasa 200 69.60 500.00 13.92 0.00 Humedad % NP NP

P1 500.00 grs

110.00

100.00 f(x) = 14.5640125945096 ln(x) + 39.8860481628312


90.00

80.00

70.00
% que pasa

60.00

50.00

40.00

30.00

20.00

10.00

0.00
100 10 1 0.1 0.01
Diámetro que pasa (mm)

GRAVA 50.76 D10 NP Cc NP LIMITE LIQUIDO NP

ARENA 35.32 D30 0.68 Cu NP LIMITE PLASTICO NP

FINOS 13.92 D60 10.1 INDICE PLASTICO NP

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


GM GRAVAS LIMOSAS CON ARENAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/2/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 405

W Tara + S. Hum (g) 534.8 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 497.6 SONDEO S8

w tara (g) 61.8 PROFUNDIDAD (m) 1.00 - 2.00


W S. Seco (g) 435.8 MUESTRA M-2
W Agua (g) 37.1999999999999

Humedad % 8.54 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No.

No. mm grs grs Retenido Que pasa W Tara + S. Hum

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec

21/2 62.5 0.00 0.00 0.00 100.00 W Tara

2.0 50 0.00 0.00 0.00 100.00 W S. Seco

11/2 37.5 0.00 0.00 0.00 100.00 W Agua

1" 25 0.00 0.00 0.00 100.00 Humedad %

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes NP NP NP

1/2 12.5 86.60 86.60 17.32 82.68

3/8 9.5 51.40 138.00 10.28 72.40 LIMITE PLASTICO (INV E-126-13)

4 4.76 44.40 182.40 8.88 63.52 Tara No.

10 2 52.40 234.80 10.48 53.04 W Tara + S. Hum

20 1.25 29.00 263.80 5.80 47.24 W Tara + S. Sec

40 0.43 18.80 282.60 3.76 43.48 W Tara

100 0.15 19.40 302.00 3.88 39.60 W S. Seco

200 0.07 5.00 307.00 1.00 38.60 W Agua

Pasa 200 193.00 500.00 38.60 0.00 Humedad % NP NP

P1 500.00 grs

110.00

100.00 f(x) = 10.8297421912439 ln(x) + 55.7360613846957


90.00

80.00

70.00
% que pasa

60.00

50.00

40.00

30.00

20.00

10.00

0.00
100 10 1 0.1 0.01
Diámetro que pasa (mm)

GRAVA 36.48 D10 NP Cc NP LIMITE LIQUIDO NP

ARENA 24.92 D30 NP Cu NP LIMITE PLASTICO NP

FINOS 38.60 D60 3.6 INDICE PLASTICO NP

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SM ARENAS LIMOSAS CON GRAVAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/3/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 402

W Tara + S. Hum (g) 940.4 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 771.4 SONDEO S9

w tara (g) 64.6 PROFUNDIDAD (m) 0.00 - 1.00


W S. Seco (g) 706.8 MUESTRA M-1
W Agua (g) 169

Humedad % 23.91 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No. 25 26 214

No. mm grs grs Retenido Que pasa W Tara + S. Hum 28.27 29.40 30.52

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec 24.55 25.66 26.75

21/2 62.5 0.00 0.00 0.00 100.00 W Tara 8.30 8.56 8.71

2.0 50 0.00 0.00 0.00 100.00 W S. Seco 16.25 17.10 18.04

11/2 37.5 0.00 0.00 0.00 100.00 W Agua 3.72 3.74 3.77

1" 25 0.00 0.00 0.00 100.00 Humedad % 22.89 21.87 20.90

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes 17 24 32

1/2 12.5 0.00 0.00 0.00 100.00

3/8 9.5 16.40 16.40 3.28 96.72 LIMITE PLASTICO (INV E-126-13)

4 4.76 14.80 31.20 2.96 93.76 Tara No. 11 66

10 2 15.80 47.00 3.16 90.60 W Tara + S. Hum 21.33 20.22

20 1.25 23.20 70.20 4.64 85.96 W Tara + S. Sec 19.52 18.56

40 0.43 49.80 120.00 9.96 76.00 W Tara 8.79 8.66

100 0.15 113.20 233.20 22.64 53.36 W S. Seco 10.73 9.90

200 0.07 27.80 261.00 5.56 47.80 W Agua 1.81 1.66

Pasa 200 239.00 500.00 47.80 0.00 Humedad % 16.87 16.77

P1 500.00 grs

110.00 23.50
f(x) = 7.18931309723458 ln(x) + 76.5307068151531
100.00
23.00
90.00 f(x) = − 0.132686426817881 x + 25.1159221046142
80.00 22.50

70.00 22.00
Humedad %
% que pasa

60.00
21.50
50.00

40.00 21.00

30.00 20.50
20.00
20.00
10.00

0.00 19.50
100 10 1 0.1 0.01 10 Numero de golpes 100

Diámetro que pasa (mm)

GRAVA 6.24 D10 NP Cc NP LIMITE LIQUIDO 21.80

ARENA 45.96 D30 NP Cu NP LIMITE PLASTICO 16.82

FINOS 47.80 D60 0.21 INDICE PLASTICO 4.98

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SM-SC ARENAS LIMO ARCILLOSAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/3/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 350

W Tara + S. Hum (g) 886.8 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 794.6 SONDEO S9

w tara (g) 71.6 PROFUNDIDAD (m) 1.00 - 2.00


W S. Seco (g) 723 MUESTRA M-2
W Agua (g) 92.1999999999999

Humedad % 12.75 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No.

No. mm grs grs Retenido Que pasa W Tara + S. Hum

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec

21/2 62.5 0.00 0.00 0.00 100.00 W Tara

2.0 50 0.00 0.00 0.00 100.00 W S. Seco

11/2 37.5 0.00 0.00 0.00 100.00 W Agua

1" 25 0.00 0.00 0.00 100.00 Humedad %

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes NP NP NP

1/2 12.5 0.00 0.00 0.00 100.00

3/8 9.5 0.00 0.00 0.00 100.00 LIMITE PLASTICO (INV E-126-13)

4 4.76 4.20 4.20 0.84 99.16 Tara No.

10 2 7.20 11.40 1.44 97.72 W Tara + S. Hum

20 1.25 10.60 22.00 2.12 95.60 W Tara + S. Sec

40 0.43 53.00 75.00 10.60 85.00 W Tara

100 0.15 195.80 270.80 39.16 45.84 W S. Seco

200 0.07 62.60 333.40 12.52 33.32 W Agua

Pasa 200 166.60 500.00 33.32 0.00 Humedad % NP NP

P1 500.00 grs

110.00
f(x) = 7.8772772304291 ln(x) + 76.2383623716203
100.00

90.00

80.00

70.00
% que pasa

60.00

50.00

40.00

30.00

20.00

10.00

0.00
100 10 1 0.1 0.01
Diámetro que pasa (mm)

GRAVA 0.84 D10 NP Cc NP LIMITE LIQUIDO NP

ARENA 65.84 D30 NP Cu NP LIMITE PLASTICO NP

FINOS 33.32 D60 0.22 INDICE PLASTICO NP

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SM ARENAS LIMOSAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/2/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 429

W Tara + S. Hum (g) 745.2 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 698.2 SONDEO S10

w tara (g) 65.4 PROFUNDIDAD (m) 0.00 - 1.00


W S. Seco (g) 632.8 MUESTRA M-1
W Agua (g) 47

Humedad % 7.43 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No.

No. mm grs grs Retenido Que pasa W Tara + S. Hum

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec

21/2 62.5 0.00 0.00 0.00 100.00 W Tara

2.0 50 0.00 0.00 0.00 100.00 W S. Seco

11/2 37.5 0.00 0.00 0.00 100.00 W Agua

1" 25 0.00 0.00 0.00 100.00 Humedad %

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes NP NP NP

1/2 12.5 96.60 96.60 19.32 80.68

3/8 9.5 43.80 140.40 8.76 71.92 LIMITE PLASTICO (INV E-126-13)

4 4.76 29.20 169.60 5.84 66.08 Tara No.

10 2 44.60 214.20 8.92 57.16 W Tara + S. Hum

20 1.25 34.40 248.60 6.88 50.28 W Tara + S. Sec

40 0.43 53.00 301.60 10.60 39.68 W Tara

100 0.15 88.40 390.00 17.68 22.00 W S. Seco

200 0.07 13.00 403.00 2.60 19.40 W Agua

Pasa 200 97.00 500.00 19.40 0.00 Humedad % NP NP

P1 500.00 grs

110.00

100.00 f(x) = 12.9843083756553 ln(x) + 49.6548117212055

90.00

80.00

70.00
% que pasa

60.00

50.00

40.00

30.00

20.00

10.00

0.00
100 10 1 0.1 0.01
Diámetro que pasa (mm)

GRAVA 33.92 D10 NP Cc NP LIMITE LIQUIDO NP

ARENA 46.68 D30 0.25 Cu NP LIMITE PLASTICO NP

FINOS 19.40 D60 2.7 INDICE PLASTICO NP

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SM ARENAS LIMOSAS CON GRAVAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/2/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 420

W Tara + S. Hum (g) 560 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 471.8 SONDEO S11

w tara (g) 62.8 PROFUNDIDAD (m) 0.00 - 1.00


W S. Seco (g) 409 MUESTRA M-1
W Agua (g) 88.2

Humedad % 21.56 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No.

No. mm grs grs Retenido Que pasa W Tara + S. Hum

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec

21/2 62.5 0.00 0.00 0.00 100.00 W Tara

2.0 50 0.00 0.00 0.00 100.00 W S. Seco

11/2 37.5 0.00 0.00 0.00 100.00 W Agua

1" 25 0.00 0.00 0.00 100.00 Humedad %

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes NP NP NP

1/2 12.5 0.00 0.00 0.00 100.00

3/8 9.5 28.00 28.00 5.60 94.40 LIMITE PLASTICO (INV E-126-13)

4 4.76 13.60 41.60 2.72 91.68 Tara No.

10 2 24.80 66.40 4.96 86.72 W Tara + S. Hum

20 1.25 23.00 89.40 4.60 82.12 W Tara + S. Sec

40 0.43 27.40 116.80 5.48 76.64 W Tara

100 0.15 94.40 211.20 18.88 57.76 W S. Seco

200 0.07 18.40 229.60 3.68 54.08 W Agua

Pasa 200 270.40 500.00 54.08 0.00 Humedad % NP NP

P1 500.00 grs

110.00

100.00 f(x) = 6.6558188800434 ln(x) + 77.3893265077691

90.00

80.00

70.00
% que pasa

60.00

50.00

40.00

30.00

20.00

10.00

0.00
100 10 1 0.1 0.01
Diámetro que pasa (mm)

GRAVA 8.32 D10 NP Cc NP LIMITE LIQUIDO NP

ARENA 37.60 D30 NP Cu NP LIMITE PLASTICO NP

FINOS 54.08 D60 0.18 INDICE PLASTICO NP

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


ML LIMOS INORGANICOS DE BAJA COMPRESIBILIDAD
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/2/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 406

W Tara + S. Hum (g) 520.2 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 476.6 SONDEO S11

w tara (g) 62.4 PROFUNDIDAD (m) 1.00 - 2.00


W S. Seco (g) 414.2 MUESTRA M-2
W Agua (g) 43.6

Humedad % 10.53 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No.

No. mm grs grs Retenido Que pasa W Tara + S. Hum

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec

21/2 62.5 0.00 0.00 0.00 100.00 W Tara

2.0 50 0.00 0.00 0.00 100.00 W S. Seco

11/2 37.5 0.00 0.00 0.00 100.00 W Agua

1" 25 0.00 0.00 0.00 100.00 Humedad %

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes NP NP NP

1/2 12.5 0.00 0.00 0.00 100.00

3/8 9.5 54.00 54.00 10.80 89.20 LIMITE PLASTICO (INV E-126-13)

4 4.76 21.80 75.80 4.36 84.84 Tara No.

10 2 29.60 105.40 5.92 78.92 W Tara + S. Hum

20 1.25 18.20 123.60 3.64 75.28 W Tara + S. Sec

40 0.43 50.20 173.80 10.04 65.24 W Tara

100 0.15 103.00 276.80 20.60 44.64 W S. Seco

200 0.07 15.40 292.20 3.08 41.56 W Agua

Pasa 200 207.80 500.00 41.56 0.00 Humedad % NP NP

P1 500.00 grs

110.00
f(x) = 8.83331785474738 ln(x) + 69.1001404332303
100.00

90.00

80.00

70.00
% que pasa

60.00

50.00

40.00

30.00

20.00

10.00

0.00
100 10 1 0.1 0.01
Diámetro que pasa (mm)

GRAVA 15.16 D10 NP Cc NP LIMITE LIQUIDO NP

ARENA 43.28 D30 NP Cu NP LIMITE PLASTICO NP

FINOS 41.56 D60 0.32 INDICE PLASTICO NP

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SM ARENAS LIMOSAS CON GRAVAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/2/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 3

W Tara + S. Hum (g) 681.6 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 579.0 SONDEO S12

w tara (g) 62 PROFUNDIDAD (m) 0.00 - 1.00


W S. Seco (g) 517 MUESTRA M-1
W Agua (g) 102.6

Humedad % 19.85 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No. 24 46 35

No. mm grs grs Retenido Que pasa W Tara + S. Hum 27.20 28.32 29.46

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec 22.37 23.50 24.62

21/2 62.5 0.00 0.00 0.00 100.00 W Tara 8.45 8.51 8.68

2.0 50 0.00 0.00 0.00 100.00 W S. Seco 13.92 14.99 15.94

11/2 37.5 0.00 0.00 0.00 100.00 W Agua 4.83 4.82 4.84

1" 25 0.00 0.00 0.00 100.00 Humedad % 34.70 32.15 30.36

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes 17 24 32

1/2 12.5 0.00 0.00 0.00 100.00

3/8 9.5 27.40 27.40 5.48 94.52 LIMITE PLASTICO (INV E-126-13)

4 4.76 18.20 45.60 3.64 90.88 Tara No. 7 71

10 2 43.40 89.00 8.68 82.20 W Tara + S. Hum 20.38 19.27

20 1.25 41.40 130.40 8.28 73.92 W Tara + S. Sec 18.52 17.49

40 0.43 42.20 172.60 8.44 65.48 W Tara 8.88 8.63

100 0.15 81.20 253.80 16.24 49.24 W S. Seco 9.64 8.86

200 0.07 16.40 270.20 3.28 45.96 W Agua 1.86 1.78

Pasa 200 229.80 500.00 45.96 0.00 Humedad % 19.29 20.09

P1 500.00 grs

110.00 36.00
f(x) = 8.30443777552076 ln(x) + 71.6165540731366
100.00
35.00
90.00
f(x) = − 0.287419986685385 x + 39.3995230761703
80.00 34.00

70.00 33.00
Humedad %
% que pasa

60.00
32.00
50.00

40.00 31.00

30.00 30.00
20.00
29.00
10.00

0.00 28.00
100 10 1 0.1 0.01 10 Numero de golpes 100

Diámetro que pasa (mm)

GRAVA 9.12 D10 NP Cc NP LIMITE LIQUIDO 32.22

ARENA 44.92 D30 NP Cu NP LIMITE PLASTICO 19.69

FINOS 45.96 D60 0.3 INDICE PLASTICO 12.52

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SC ARENAS ARCILLOSAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno
RESULTADOS DEL LABORATORIO DE SUELOS

NORMAS INVIAS: INV E-122-13, INV E-123-13, INV E-125-13, INV E-126-13, INV E-102-13 FECHA DE
7/2/2021
PROCESO: GEOLOGÍA Y DISEÑO GEOTÉCNICO MUESTREO

FECHA DE
PROYECTO: TALUD CHARALA 7/5/2021
LABORATORIO

CONTENIDO DE HUMEDAD (INV E-122-13)

Numero de tara 307

W Tara + S. Hum (g) 490.6 DESCRIPCIÓN GENERAL

W Tara + S. Sec (g) 428.2 SONDEO S12

w tara (g) 66 PROFUNDIDAD (m) 1.00 - 2.00


W S. Seco (g) 362.2 MUESTRA M-2
W Agua (g) 62.4

Humedad % 17.23 LIMITES DE CONSISTENCIA (ATTERBERG)

ENSAYO DE GRANULOMETRIA (GRADACION) (INV E-123-13) LIMITE LIQUIDO (INV E-125-13)

Tamiz Peso Ret. Acomu Ret. % % Tara No. 81 18 56

No. mm grs grs Retenido Que pasa W Tara + S. Hum 28.34 29.47 30.59

3.0 75 0.00 0.00 0.00 100.00 W Tara + S. Sec 22.58 23.66 24.74

21/2 62.5 0.00 0.00 0.00 100.00 W Tara 8.59 8.68 8.61

2.0 50 0.00 0.00 0.00 100.00 W S. Seco 13.99 14.98 16.13

11/2 37.5 0.00 0.00 0.00 100.00 W Agua 5.76 5.81 5.85

1" 25 0.00 0.00 0.00 100.00 Humedad % 41.17 38.79 36.27

3/4 19.5 0.00 0.00 0.00 100.00 No. De Golpes 17 24 32

1/2 12.5 73.00 73.00 14.60 85.40

3/8 9.5 48.20 121.20 9.64 75.76 LIMITE PLASTICO (INV E-126-13)

4 4.76 19.40 140.60 3.88 71.88 Tara No. 51 102

10 2 29.00 169.60 5.80 66.08 W Tara + S. Hum 22.46 21.28

20 1.25 27.40 197.00 5.48 60.60 W Tara + S. Sec 19.27 18.19

40 0.43 29.60 226.60 5.92 54.68 W Tara 8.65 8.58

100 0.15 67.20 293.80 13.44 41.24 W S. Seco 10.62 9.61

200 0.07 12.80 306.60 2.56 38.68 W Agua 3.19 3.09

Pasa 200 193.40 500.00 38.68 0.00 Humedad % 30.04 32.15

P1 500.00 grs

110.00 42.00
100.00 f(x) = 9.86433538579422 ln(x) + 61.2332178621694
41.00 f(x) = − 0.326671438517092 x + 46.6907171918337
90.00
40.00
80.00
39.00
70.00
Humedad %
% que pasa

60.00 38.00

50.00 37.00
40.00
36.00
30.00
35.00
20.00
34.00
10.00

0.00 33.00
100 10 1 0.1 0.01 10 Numero de golpes 100

Diámetro que pasa (mm)

GRAVA 28.12 D10 NP Cc NP LIMITE LIQUIDO 38.52

ARENA 33.20 D30 NP Cu NP LIMITE PLASTICO 31.10

FINOS 38.68 D60 1.3 INDICE PLASTICO 7.43

CLASIFICACION DEL SUELO S.U.C.S. (INV E-102-


SM ARENAS LIMOSAS CON GRAVAS
13)

REALIZÓ: REVISÓ:

Laboratorista: Tec. Juan Carlos Lopez Ing. Cristhian David Erazo Moreno

También podría gustarte