DISEÑOS DE :
DATOS GENERALES
Ancho Tributario
5.90
H VS VS VS VS VS
COL. EN EL 2º PISO
G VS
ZAPATA
###
VP
F VS
LOSA EN EL 1º PISO
###
VP
E VS
VP EN EL 5º PISO
VP
VP
VP
VP
VP
###
COLUMNA EN EL 3º PISO
D VS
ZAPATA
###
VP
C VS
PLACA
PLACA
###
VP
###
B VS EN 2º PISO
###
VP
COLUM 4º PISO
A VS
7.30 4.50 5.60 5.30 5.60
1 2 3 4 5 6
DATOS :
S/C = 500 Kg/m2 salas de archivo OFICINAS
PISO T = 100 Kg/m2
###
###
F'c = 210 Kg/m2 h d
Fy = 4200 Kg/m2
ESPESOR DE LOSA = 20 cm
VIGA SECUNDARIA = 0.5 x 0.3 m b
RECUBRIMIENTO = 6 cm 30
Pp de losa de 20cm = 300 Kg/m2
γ del concreto = 2400 Kg/m3 = 2.4 ton/m3
28.30
C VS
PLACA
PLACA
###
VP
Ancho tributario
###
B VS EN 2º PISO
###
VP
A VS
7.30 4.50 5.60 5.30 5.60
1 2 3 4 5 6
METRADO DE CARGAS
Se realiza por ancho tributario AT = 4.60 - 0.30
AT = 4.30
CARGA MUERTA : CM
Pp losa = 0.300 ton/m2 x 4.30 = 1.29 ton/m
Pp viga = 0.30 x 0.50 x 2.4 = 0.36 ton/m
Pp piso T = 0.10 x 4.30 = 0.43 ton/m
CM = 2.08 ton/m
CALCULO DEL WU
RNC
Wu= 1.5 (CM)+1.8(CV)
Wu= 7.26 ton/m
KU = Ø q F'c ( 1-0.59 q )
KU = 0.9 q 210 ( 1-0.59 q )
KU = 189 q - 111.5 q2
111.5 q2 - 189 q + KU = 0
111.5 q2 189 q KU
- + = 0
111.51 111.5 111.5
KU
q2 - 1.695 q + = 0
q2 - 1.695 q + = 0
111.5
KU
1.695 - 1.695 2
- 4
q = 111.5
2
DIAGRAMA A ANALIZAR
7.26
uniformizando
4 Ø de 1''
DISEÑO DE VP 101
DATOS :
S/C = 200 Kg/m2 salas de archivo OFICINAS
2
PISO T = 100 Kg/m
21
h d
25
F'c = 210 Kg/m2
2
Fy = 4200 Kg/m
ESPESOR DE LOSA = 20 cm
RECUBRIMIENTO = 4 cm 25
Ancho tributario
3.50
1 2.87 2 4.12 3
C
3.65
D
3.60
METRADO DE CARGAS
KU = 189 q - 111.51 q2 KU
1.695 - 1.695 2
- 4
111.51 q 2
- 189 q + KU = 0 q = 111.51
111.51 q2 189 q KU 2
- + = 0
111.51 111.51 111.51
para tomar el menor
DIAGRAMA A ANALIZAR
3.4302
ton/m
3.65 3.65
2.25
VP = 35 x 70 I 4.00
VS = 30 x 50 II 3.80
VP
C4 = 40 x 40 III 3.60
###
fy = 4200 Kg/m2 IV 3.40
f'c = 210 Kg/m 2
V 3.20
2.25
γ c = 2.4 Ton/m3
losa = 20 cm
PISO T = 100 Kg/m2
s/c = 300 Kg/m 2
Pp de losa de 20cm A VS
s/c = 500 kg/cm2 salas de archivo OFICINAS 1 7.30 2
# de veces = 5 pisos - 4 pisos
# de pisos = 1 pisos
METRADOS
CALCULO DE CARGAS
a) CARGAS VIVAS CV
b) CARGAS MUERTAS CM
CARGAS ULTIMA
PU = 1.5 CM + 1.8 CV
PU =( 1.5 x 6.2209 ) + ( 1.8 X 4.0263 )
PU = 16.579 ton
REFUERZO LONGITUDINAL
ADOPTAMOS = 4 Ø 5/8"
REFUERZO TRANSVERSAL
t= 0.40 m
LONGITUD = h/6 = 0.53 m @ 0.10 m
si h = 3.20 m Ø 3/8"
16 Ø L = 16 x 0.953 = 15.248 cm
Ø 3/8" 48 Ø e = 48 x 0.953 = 45.744 cm Para diseño tomamos el menor
0.953 b = 40 cm
1 @ 0.05
2 @ 0.10
0.40 2 @ 0.15
resto @ 0.20
4 Ø 5/8"
0.40
Ø 3/8"
ton
ton
ton
ton
ton
ton
2.80 2.80
DATOS Nº h
VP
7.6
VP = 35 x 70 I 4.00
3.80
VS = 30 x 50 II 3.80
C4 = 40 x 40 III 3.60
6.40
fy = 4200 Kg/m2 IV 3.40 D
f'c = 210 V 3.20
2.60
2
Kg/m
γ c = 2.4 Ton/m3
5.2
losa = 20 cm
# de pisos = 2 pisos
METRADOS
2.98 m2
CALCULO DE CARGAS
a) CARGAS VIVAS CV
b) CARGAS MUERTAS CM
PPpt = S/C x (AreaT - AreaCol) x # de piso = 0.10 X( 17.92 - 0.16 )X 2 PP pt = 3.552 ton
PP col = b x t x h piso x γc' 4º piso = 0.40 x 0.40 x 3.40 x 2.40 PP col = 1.306 ton
CM = 23.83 ton
CARGAS ULTIMA
PU = 1.5 CM + 1.8 CV
PU =( 1.5 x 23.834 ) + 1.8 X 17.76 )
PU = 67.720 ton
REFUERZO LONGITUDINAL
-0.016 + 67.72 = As
2.252
30.063 = As
As = 30.06 cm2
ADOPTAMOS = 6 Ø DE 1"
REFUERZO TRANSVERSAL
t= 0.40 m
si h = 3.20 m Ø 3/8"
16 Ø L = 16 x 0.953 = 15.248 cm
0.953 b = 40 cm
1 @ 0.05
2 @ 0.10
0.40 2 @ 0.15
resto @ 0.20
6 Ø DE 1"
0.40
Ø 3/8"
5.05
COLUMNA ESQUINERA : del 2º PISO H
Nº PISOS
VP
DATOS Nº h 2.25 2.80
VP = 35 x 70 I 4.00
7.5
3.75
VS = 30 x 50 II 3.80
G
6.50
C4 = 40 x 40 III 3.60
fy = 4200 Kg/m 2
IV 3.40
2.75
f'c = 210 Kg/m 2 V 3.20
γc = 2.4 Ton/m3
5.5
losa = 20 cm
# de pisos = 3 pisos
METRADOS
3.69 m2
CALCULO DE CARGAS
a) CARGAS VIVAS CV
b) CARGAS MUERTAS CM
PPpt = S/C x (AreaT - AreaCol) x # de piso = 0.10 X ( 32.83 - 0.16 )X 3 PP pt = 9.7995 ton
PP col = b x t x h piso x γc' 3º piso = 0.40 x 0.40 x 3.60 x 2.40 PP col = 1.3824 ton
CM = 55.72 ton
CARGAS ULTIMA
PU = 1.5 CM + 1.8 CV
PU =( 1.5 x 55.72 ) + 1.8 X 49 )
PU = 171.776 ton
REFUERZO LONGITUDINAL
-0.016 + 171.78 = As
2.252
76.269 = As
As = 76.27 cm2
REFUERZO TRANSVERSAL
t= 0.40 m
si h = 3.20 m Ø 3/8"
16 Ø L = 16 x 0.953 = 15.248 cm
0.953 b = 40 cm
1 @ 0.05
2 @ 0.10
0.40 2 @ 0.15
resto @ 0.20
4 Ø 1 1/4" + 8 Ø 1''
0.40
Ø 3/8"