ÍNDICE
1- Contenido .......................................................5
2- Controles .......................................................6
3- Advertencias .......................................................7
6- Instrucciones .......................................................14
6.1 Colocación de batería y cambio de .......................................................14
fusibles
7- Modo retención de datos .....................................................15
8- Medición por inductancia .....................................................16
9- Prueba de continuidad audible .....................................................17
10- Medición de resistencia Ω .....................................................18
11- Medición de voltaje directo V - - - .....................................................19
12- Medición de voltaje alterno V ~ .....................................................20
13- Prueba de diodos .....................................................21
14- Medición de frecuencia .....................................................22
4
1. Contenido
1. Multímetro
2. Cables de medición
3. Adaptador multifunción
4. Termopar tipo K
1 2 3
MS8260C
HOLD
200
200
2K 20K 200K
2M
20M
200M
4
2 200m
200n
20n 20
TEMP 200
20m 600
200m 600
A 10 200
10 20
200m 2
20m
A hFE 20kHz
COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP
MAX 30 sec.
every 15 min.
5
2-Controles
1. Área de detección de 1 2
voltaje.
2. Indicador de detección de
3
voltaje.
3. Pantalla LCD. 4 HOLD
MS8260C
6
4. Botón de encendido/ 2K 20K 200K
5 200 2M
20M
200M
apagado.
200
2 200m
200n
7
20n 20
20m 600
1000
200m 600
750
A 10
20
200
10
COM
MAX 10A
hFE FUSED
mA 10A
TEMP
8
8. Puntas de medición.
98
9. Terminales
6
3. Advertencias
Para evitar el riesgo de un choque eléctrico o daño en su persona
y un posible daño al medidor o al equipo bajo prueba, observar las
siguientes reglas:
7
3. Advertencias
- Antes de utilizar el medidor inspeccione la cubierta. No lo
use si la cubierta o parte de ésta ha sido removida. Revise la
pérdida de plástico sobre todo alrededor de los conectores.
8
3. Advertencias
- No use o almacene el medidor en un ambiente de alta temperatura,
humedad, explosivo, inflamable o con campo magnético fuerte. El
desempeño del medidor puede deteriorarse después de ser
humedecido o mojado.
-Cuando use las puntas de prueba mantenga los dedos más allá de
las guardas.
solventes.
11
5. Símbolos en la pantalla
Símbolo Significado
La batería está baja. Para evitar lecturas falsas, que podrían llevar a posibles
choques eléctricos o lesiones corporales, remplace la batería en cuanto este
símbolo aparezca en la pantalla.
12
Símbolo Significado
El multímetro está en modo continuidad.
,K ,M 3
6
kHz 3
Kilohertz. 1 x 10 o 1000 Hertz
13
6. Instrucciones
6.1 Colocación de batería y cambio del fusible
1. Remueva la carcasa protectora.
2. Levante la pestaña ubicada en la parte posterior del multímetro.
3. Retire el tornillo con un desarmador y quite la tapa.
4. Inserte una batería de 9 V. Ponga atención en la polaridad. Si desea
cambiar un fusible, quite los cuatro tornillos al rededor de la tapa posterior
para abrirlo a la mitad, remueva el fusible viejo e instale uno nuevo
(FF400mA/1000V o FF10A/600V)
5. Coloque la tapa y atorníllela.
Cuando el ícono de batería aparezca en la pantalla, deberá
reemplazarla por una nueva.
14
7. Modo retención de datos
1.-Presione el botón HOLD una vez para fijar el valor medido en la
pantalla, en la cual aparecerá la letra H.
2.- Presione una vez más el botón HOLD para regresar al modo normal.
HOLD
15
8. Detección de voltaje por inductancia
Esta función solamente detecta el voltaje, sin medirlo bajo el principio de
autoinductancia.
1. Encienda el multímetro. La posición de la perilla no importa, ya que
ésta función es de detección y no de medición.
2. Acerque el sensor de la parte superior al equipo o componente que
desea comprobar si tiene energía eléctrica (cables, contactos, sockets,
etcétera).
El indicador se encenderá al detectar voltaje mayor a 110 V (rms).
2K 20K 200K
200 2M
20M COM 600V
CAT III Hz
200M
200
2 200m
MAX 10A
200n hFE FUSED
mA 10A
20n 20 TEMP MAX 30 sec.
every 15 min.
TEMP 200
600
20m
17
10. Medición de resistencia Ω
La resistencia es una oposición al flujo de corriente (La unidad de
resistencia es el ohm Ω.)
1. Seleccione con la perilla el rango de resistencia
2. Conecte la punta roja a ΩVHz y la negra a COM.
3. Realice la medición en el circuito o componente a medir
1 2
COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
- +
18
11. Medición de voltaje directo V - - -
Voltaje es la diferencia de potencial entre dos puntos, la polaridad de la
corriente directa es constante.
1. Gire la perilla al rango V ---
2. Conecte la punta roja a ΩVHz y la negra a COM.
3. Realice la medición en el circuito o componente a medir.
2 COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
- +
19
12. Medición de voltaje alterno V ~
1. Gire la perilla al rango V~
2. Conecte la punta roja a ΩVHz y la negra a COM.
3. Realice la medición en el circuito o componente a medir.
2
600
600
COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
- +
20
13. Prueba de diodos
Use esta prueba para revisar diodos y otros dispositivos
semi-conductores. La prueba de diodo envía una corriente a través de la
unión del semiconductor y entonces mide el voltaje de caída a través de la
unión. Una buena unión de silicón cae de 0,5 a 0,8 V.
1. Gire la perilla a la función [ ].
2. Conecte las puntas negra en COM y la punta roja en ΩVHz.
3. Conecte las puntas al componente semiconductor ponga la punta roja
al ánodo y la negra al cátodo.
4. Realice la medición el valor se mostrara en la pantalla
1 COM 600V
CAT III Hz
2
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
- +
21
14. Medición de frecuencia
Frecuencia es el número de ciclos que completa la señal de voltaje o
corriente cada segundo.
1. Gire la perilla a la escala de frecuencia 20 kHz.
2. Conecte la punta roja a ΩVHz y la negra a COM.
3. Realice la medición en el circuito o componente a medir
1
20kHz
2 COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
- +
medición.
23
1. Apague la alimentación del circuito a medir. Descargue todos los
capacitores de alto voltaje.
2. Gire la perilla a la función “--- A” y realice la medición.
3. Conecte la punta roja a la terminal hFEmA TEMP para un máximo
de 200 mA y a la de “10 A” para un máximo de 10 A; y la negra a la
terminal COM.
4. Rompa el camino del circuito a medir. Conecte el cable negro al lado
más negativo de donde rompió el circuito y el rojo a la parte más positiva.
(Invertir los cables dará una lectura negativa.)
5. Encienda la alimentación del circuito a medir y vea la medición.
Si aparece un “1”, esto indica que hay un sobre rango, elija un rango más
alto.
COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
A +
24
16. Medición de corriente alterna A ~
1. Conecte la punta roja a 10 A y la negra a COM.
2. Gire la perilla a la función A~ y realice la medición.
1 COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
2
600
600
A
Nota: Para medir escalas de corriente más pequeñas, conecte la
punta roja a la entrada “hFEmA TEMP”.
25
17. Medición de temperatura
1. Gire la perilla a la función TEMP
2. Conecte el adaptador multifunción en las entradas COM y TEMP.
3. Conecte el termopar tipo “K” en el adaptador. Ponga atención en la
polaridad.
4. Encienda el multímetro y realice la medición.
TEMP 600
600
2 -
+
+ 3
-
Nota: El multímetro puede hacer una detección de temperatura ambiental
incluso cuando los aditamentos para esta medición no estén conectados,
siempre que la perilla esté en la posición TEMP.
26
Para evitar choque eléctrico o daños al instrumento, nunca
y la terminal COM.
o 24 V CA RMS.
27
18. Medición de capacitancia
Capacitancia es la habilidad de un componente de retener carga eléctrica.
COM 600V
CAT III Hz 2
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
- +
28
19. Medición de transistores
1.Conecte el adaptador multifunción en las entradas COM y TEMP,
después coloque la perilla giratoria en hFE.
2. Identifique el tipo de transistor NPN o PNP
3. Coloque cada pata del transistor en los conectores del adaptador.
Identifique el colector (c), la base (b) y el emisor (e).
29
Para evitar choque eléctrico o daños al instrumento, nunca
terminal COM.
30
20. Tablas de especificaciones
Voltaje Directo
Rango Resolución Precisión
200mV 0.1mV
2V 1mV
+- (0.5% de rdg + 2 digitos)
20V 10mV
200V 100mV
Impedancia de entrada: 10 MΩ
Entrada máxima de voltaje: 250 V DC o AC rms para el rango de
200 mV, y 600 V DC o 600 V AC rms para otros rangos.
Voltaje Alterno
Rango Resolución Precisión
2v
V 1mV
20V 10mV
- (0.8% de rdg + 3 digitos)
+
200V 100mV
750V
600V 1V - (1.2% de rdg + 3 digitos)
+
Impedancia de entrada: 10 MΩ
Entrada máxima de voltaje: 250 V DC o AC rms para el rango de 200 mV,
y 600 V DC o 600 V AC rms para otros rangos.
Rango de frecuencia: 40 Hz-400 Hz
Respuesta: Promedio, calibrada en rms de onda sinusoidal.
31
Frecuencia
Rango Rango Precisión
20kHz 10Hz +- (3% de rdg + 5 digitos)
Resistencia
Rango Resolución Precisión
200 0.1 +- (0.8% de rdg + 3digitos)
2k 1
20k 10
+-(0.8% de rdg + 5 digitos)
200k 100
2M 1k
200m
M 0.1M +- (5.0% de rdg + 10digitos)
32
Prueba de diodos
Rango Resolución Función
Transistores
Rango
Rango Descripción Condición de prueba
Muestra lectura apróximada.
Muestra lectura aproximada. Base actual aproximada
hFE Valor HFE (0-1000)
Tensión
de transistor
directa del diodo.
bajo prueba.
h
10 A, Vce aproximado. 2.8V.
(todo tipo)
33
Temperatura
Rango
Rango Resolución Precisión
Capacitancia
Rango Resolución Precisión
20nF 10pF
200nF 0.1nF +- (4.0% de rdg + 3 digitos)
h
2 F 1nF
200hF 100nF +-(5.0% de rdg + 10 digitos)
34
Corriente directa
Rango
Rango Resolución Precisión
20 mA 10µA
+- (1% de rdg + 1 digito)
200 mA 0.1mA
10 A 10mA +- (2.0% de rdg + 5 digitos)
Corriente alterna
Rango
Rango Resolución Precisión
35
Terminales
36
Especificaciones
37
Producto: Multímetro digital con detector de voltaje
Modelo: MUL-288
Marca: Steren
PÓLIZA DE GARANTÍA
Esta póliza garantiza el producto por el término de un año en todas sus partes y mano de obra, contra
cualquier defecto de fabricación y funcionamiento, a partir de la fecha de entrega.
CONDICIONES
1.- Para hacer efectiva la garantía, presente esta póliza y el producto, en donde fue adquirido o en
Electrónica Steren S.A. de C.V.
2.- Electrónica Steren S.A de C.V. se compromete a reparar el producto en caso de estar defectuoso sin
ningún cargo al consumidor. Los gastos de transportación serán cubiertos por el proveedor.
3.- El tiempo de reparación en ningún caso será mayor a 30 días, contados a partir de la recepción del
producto en cualquiera de los sitios donde pueda hacerse efectiva la garantía.
4.- El lugar donde puede adquirir partes, componentes, consumibles y accesorios, así como hacer válida esta
garantía es en cualquiera de las direcciones mencionadas posteriormente.
0C
826
MS
LD
HO
K 2M 20M 00M
200 2
20K m
2K 200
200
20
200
200 600
2 600
n
200 200
20n 20
P
TEM 2
20m
m H z
200 20k
10 m 20m FE
A 10
200 h
A Hz
600V III
CAT
M
CO 10A
MAX SED
FU 10A
c.
30 se in.
MAX y 15 m
hFEA ever
m MP
TE
www.steren.com
The instructions of this manual are for reference about the product. There may
be differences due to updates.
Please check our web site (www.steren.com) to obtain the latest version of the
instruction manual.
2
Highlights
With this multitister you can make school projects, work repair or
maintenance professionally. It has the voltage detection function is
very useful when wanting to locate lines energized cables in ducts or
walls inaccessible. Get accurate measurements of voltage, current,
capacitance, temperature, frequency, continuity and transistor beta.
Is possible to illuminate the display to observe the readings
despite low light, also includes a function that returns
data on the screen (HOLD), ideal for taking notes or switch
position. Includes all accessories needed for operation.
3
INDEX .......................................................5
1- Content
2- Controls .......................................................6
3- Warnings .......................................................7
4- Cautions .......................................................9
4.1 General Maintenance .....................................................10
5. Display symbols .....................................................11
6- Instructions .....................................................13
6.1 Battery and fuse placement .....................................................13
.....................................................14
7- HOLD
.....................................................15
8- Voltage detection by inductance
.....................................................16
9- Audible continuity test
.....................................................17
10- Measuring resistance Ω
.....................................................18
11- Measuring DC voltage - - -
.....................................................19
12- Measuring AC voltageV ~
.....................................................20
13- Diode test
.....................................................21
14- Measuring frequency
.....................................................22
15- Measuring direct current A - - -
1 2 3
MS8260C
HOLD
4
2K 20K 200K
200 2M
20M
200M
200
2 200m
200n
20n 20
TEMP 200
20m 600
200m 600
A 10 200
10 20
200m 2
20m
A hFE 20kHz
COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP
MAX 30 sec.
every 15 min.
5
2. Controls
1 2
1. Voltage detection area
2. Voltaje detection LED indicador
3. LCD screen
4. ON/OFF 3
5. HOLD: Press once to retain the
measurement data on the screen. 4 HOLD
MS8260C
6
Press it again to make new mea-
2K 20K 200K
5
surements.
200 2M
20M
200M
200
2 200m
TEMP
20
200 7
backlite on for 5 seconds. 20m
200m
600
1000
600
750
A 10 200
9. Terminals hFE
mA
TEMP
MAX 10A
FUSED
10A
MAX 30 sec.
every 15 min.
98
6
3. Warnings
To avoid the risk of electric shock or damage to your person and possible
damage to the meter or the equipment under test, observe the following
warnings:
- Remove the test leads before opening or removing the Meter’s battery
compartment cover.
- When servicing the Meter, use only the same models and spare parts
identical to the original.
- Before opening the instrument, remove all sources of power and ensure
that you are not charged with static electricity as it can destroy internal
components.
- Any maintenance or repair work carried out with the meter should be
performed by qualified personnel, after taking into account the instructions
in this manual.
7
3. Warnings
- Before using the Meter inspect the case. Do not use if the cover or part
of it has been removed. Check loss of plastic specially around the
connectors.
- Inspect the test leads for damaged insulation or exposure of metal parts.
Inspect the test leads for continuity. Use only test leads included with the
meter, replace the damaged ends with an identical model of the same
electrical characteristics.
- Do not apply more than the ratio of voltage marked on the meter, bet-
ween terminals or between any terminal and earth.
- The rotary switch should be placed upright and no overload range should
be displayed during measurement, this prevents damage meter.
- Use the proper terminals, function and range for your measurements.
- Do not use or store the meter in an environment of high temperature,
humidity, explosive, flammable or strong magnetic field. Meter
performance may deteriorate after being moistened or wet.
- When using probes, keep fingers beyond the guards.
- Disconnect circuit power and discharge all high-voltage capacitors before
testing resistance, continuity, diodes, current or capacitance.
8
4. Cautions
- Screen may become unstable or mark an error if the meter is used near
noise generating equipment.
- Only use the meter according to this instruction.
- Use extreme caution when working with bare conductors or busbars.
- Do not operate the Meter around explosive gas, vapor or dust.
- Check meter operation by measuring a voltage already known.
- Use the right terminals, functions and ranges for your measurements.
- When the measurement range is not known, start with the highest.
- Do not exceed the maximum input values shown in the charts.
- Do not touch the terminals that are not in use when measuring circuits.
- When making connections, connect the common test lead first and then
the live test lead and vice versa when unplugging, remove the live test
lead first and then the common test lead.
- Before changing functions, disconnect the test leads from the tested
circuit.
-- Do not measure voltages greater than 600 V CAT III installations.
(Category III is for measurements performed in installations of buildings.)
- Do not operate the meter without the lid.
9
- Before measuring current check the meter fuses’ and turn off
the circuit before connecting the meter to it.
- With low battery meter can produce false readings that can
lead to electrical shock and personal injury.
- The internal circuit should not be altered to avoid risk of injury
or accident.
- If you are not using the meter for a long time, remove the
battery.
use solvents.
10
5. Display Symbols
Symbol Meaning
The battery is low. To avoid wrong readings, which could lead to possible electric
shock or personal injury, replace the battery as soon as this symbol appears on
the screen.
11
hFE Gain factor (beta transistors)
12
6. Instructions
6.1 Battery and fuse placement
1. Remove cover protector.
2. Locate the battery cover on the back side of the multimeter.
3. Use a screwdriver to remove the screw and lift the cover.
4. Insert a 9 V battery. Verify the polarity. Or in case, remove the old fuse
and install a new one (FF400mA / 1000V or FF10A / 600V)
5. Replace the cover and screw it back on.
When the battery icon appears on the screen, you must replace it.
13
7. HOLD mode
Press the Hold button once. The letter H will appear on the screen. If you
press the Hold button again, the multimeter will return to normal mode.
HOLD
14
8. Voltage detection by inductance
This function detects voltage without measure under the principle of
self-inductance
1. Turn on the meter. The position of the knob not matter, since this
function is not detection or measurement.
2. Lift the sensor from the top to the equipment or component to check for
electricity (cables, contacts, sockets, etc.) part.
The indicator lights when detecting more than 110 V (rms) voltage.
Even if the LED does not light, there may be voltage; do not trust in the
voltage detector to determine the presence of electricityin one cable.
Sensing operation is subject to several factors, including the
thickness and type of insulation.
If the terminal detects voltage, it is possible that the LED lights.
Keep the meter away from sources of electrical noise during testing,
because they can give false readings.
15
9. Audible continuity test
1. Turn the knob and select the diode scale. The symbol ( ) will appear
on the screen.
2. Connect the testing leads to the circuit to be measured.
3. If the resistance is lower than 30 Ohm, the buzzer will sound.
2K 20K 200K
200 2M
20M
200M
200 COM 600V
CAT III Hz
2 200m
200n
20n 20 MAX 10A
hFE FUSED
200 mA 10A
TEMP TEMP MAX 30 sec.
600
20m every 15 min.
16
10. Measuring resistance Ω
To prevent electric shock and/or damage to the equipment, disconnect the
circuits and drain the capacitors of high voltage.
Resistance is an opposition to the current flow. The unit of resistance is
the ohm Ω.
1. Connect the red testing lead to ΩVHz and the black testing lead to
COM.
2. Turn the knob to the “Ω” function and realize the measurement.
1 2
COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
- +
17
11. Measuring direct voltage V - - -
Voltage is the electrical potential difference between two points. The
polarity of the alternating current voltage varies with time; voltage polarity
of the direct current is constant.
1. Connect the red testing lead to ΩVHz and the black testing lead to
COM.
2. Turn the knob to the V --- function and realize the measurement.
2 COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
- +
18
12. Measuring AC voltage V ~ scale
1. Connect the red testing lead to ΩVHz and the black testing lead to
COM.
2. Turn the knob to the “V ~” function and realize the measurement.
600
600
2
COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
- +
19
13. Diode test
Use this test to check diodes and other semi-conductors devices. The
diode test sends a current through the
semiconductor junction and then measures the voltage drop across the
junction. Good bonding of silicon drops from 0.5 to 0.8 V.
1. Turn the knob to ( ) function.
2. Connect the test tip to the red anode of the diode to be measure and
the black one to the cathode. Realize the measurement.
1 COM 600V
CAT III Hz
2
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
- +
Ensure that circuits are without power and fully discharged capacitors
to avoid electrical shock or damage to the equipment.
20
14. Measuring frequency
Frequency is the number of cycles to complete the signal voltage or
current every second.
1. Connect the red testing point to ΩVHz and the black testing point to
COM.
2. Turn the knob to the 20 kHz frequency.
1
20kHz
2 COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
- +
21
15. Measuring direct current A - - -
current terminals.
22
1. Turn off the power to the circuit under test. Discharge all high-voltage
capacitors.
2. Connect the red lead to the hFEmA TEMP terminal for a maximum of
200 mA and “10 A” for up to 10 A; and black to COM terminal.
COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
A +
23
16. Measuring alternating current (A ~)
1. Connect the red testing point to 10 A and the black one to COM.
2. Turn the knob to the “A~” function and realize the measurement.
1 COM 600V
CAT III Hz
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
A
Note: To measure smaller current scales, connect the red testing lead
to hFEmA TEMP.
24
17. Temperature measurement
1. Connect the multifunction adapter to the COM and TEMP terminals.
2. Connect the plug to the adapter. Verify the polarity.
3. Turn the knob and select the TEMP scale. Turn the multimeter on and
realize the measurement.
TEMP
2 -
+
+ 3
-
25
To avoid electrical shock or instrument damage, never apply
24 V AC RMS.
microwave ovens.
26
18. Measuring capacitance
Capacitance is the ability to retain a component of electric charge.
1. Connect the multifunction adapter to the COM and hFEmA TEMP
terminals.
2. Turn the knob to the capacitor scale.
3. Connect the test leads across the object to be measured.
The measurement value is displayed on the screen.
COM 600V
CAT III Hz 2
MAX 10A
hFE FUSED
mA 10A
TEMP MAX 30 sec.
every 15 min.
- +
28
To avoid electrical shock or instrument damage, never apply
more than 250 V or 250 V AC CD rms between the hFE terminal and
any circuit.
29
20. Specification tables
Direct voltage
Range Resolution Accuracy
200mV 0.1mV
2V 1mV
+- (0.5% of rdg + 2 digits)
20V 10mV
200V 100mV
1000V
600V 1V +- (0.8% of rdg + 2 digits)
Input impedance: 10 MΩ
Maximum input voltage: 250V DC or AC rms for the range of
200 mV and 600 V DC or AC 600 V rms for other ranges.
Alterning voltage
Range Resolución Accuracy
2vV 1mV
20V 10mV
+- (0.8% of rdg + 3 digits)
200V 100mV
Input impedance: 10 MΩ
Maximum input voltage: 250V DC or AC rms for the range of 200 mV and
600 V DC or AC 600 V rms for other ranges.
Frequency range: 40 Hz-400 Hz
Response: Average, calibrated in rms of sine wave.
30
Frecuency
Range Rango Accuracy
20kHz 10Hz +- (3 % of rdg + 5 digits)
Resistence
2k 1
20k 10
+- (0.8% of rdg + 5 digits)
200k 100
2M 1k
M
200m 0.1M +- (5.0% of rdg + 10 digits)
31
Diode test
Range Resolution Function
DC: approx. 1 mA
Reverse Voltage DC: approx. 2.8 V
Overload Protection: 250 DC or AC rms 250.
Audible continuity
Transistors
Range
Rango Description Test condition
Display read approx.
approx. reading
Muestra lectura aproximada. Current base approx.
Base current
hFE HFE value (0-1000)
Tensión
of transistor
under directa
test. del diodo.
h
10 A, Vce approx. 2.8V.
(all type)
32
Temperature
Rango
Range Resolution Accuracy
Capacitance
20nF 10pF
200nF 0.1nF +- (4.0% of rdg + 3 digits)
h
2 F 1nF
200hF 100nF +- (5.0% of rdg + 10 digits)
33
Direct current
Range Resolution Accuracy
20nF 10pF
200nF 0.1nF +- (4.0% of rdg + 3 digits)
h
2 F 1nF
200hF 100nF +- (5.0% of rdg + 10 digits)
Altering current
Rango
Range Resolution Accuracy
34
Terminals
Description
35
Specifications
36
Product:Voltage detector multitester
Part number: MUL-288
Brand: Steren
WARRANTY
This Steren product is warranted under normal usage against defects in workmanship
and materials to the original purchaser for one year from the date of purchase.
CONDITIONS
1. This warranty card with all the required information, invoice, product box or
package, and product, must be presented when warranty service is required.
2. If the product is in the warranty time, the company will repair it free of charge.
3. The repairing time will not exceed 30 natural days, from the day the claim was
received.
4. Steren sell parts, components, consumables and accessories to customer, as well
as warranty service, at any of the addresses mentioned later.
If the product has been damaged by an accident, acts of God, mishandling, leaky
batteries, failure to follow enclosed instructions, improper repair by unauthorized
personnel, improper safe keeping, among others.
a) The consumer can also claim the warranty service in the purchase establishment.
b) If you lose the warranty card, we can reissue it, if you show the invoice or purchase
ticket.
RETAILER INFORMATION
Name of the retailer In case your product fails
Address or have questions, please
Product contact your nearest dealer.
Brand If you are in Mexico, please
Part number call to our Call Center.
Serial number 01 800 500 9000
Date of delivery
37