Está en la página 1de 9

BIZARRO NAVA AXEL GIOVAN

SECUANCIA DE CALCULOS DEL ROTAMETRO

π 2 VT
AT = D V T = AT ∆ z Gv H =
4 θ 2O

MEDIDORES DE FLUJO
Corrida %R Rotámetro Tubo Vénturi Placa de Orificio
ΔZTanque =0.02 m
θ (seg) θ (min) ΔH (cm) ΔH (m) ΔH (cm) ΔH (m)
1 50 96 1.60 5.70 0.057 2.80 0.028
2 60 85 1.42 5.70 0.057 3.00 0.030
3 70 84 1.40 7.60 0.076 3.20 0.032
4 80 59 0.98 10.20 0.102 5.20 0.052
5 90 56 0.93 12.50 0.125 6.70 0.067
Diámetro del tanque de alimentación = 108 cm=1.08 m

Corrida 1

π π
Gv H =
( 4)
D ( ) ( 1.08 m) ( 0.02m)
2

=
4
2

=0.0116
m 3
=11.4511
L
2O
θ 1.60 min min min

Corrida 2

π π
Gv H =
( 4)
D ( ) ( 1.08 m) ( 0.02m)
2

=
4
2

=0.0129
m 3
=12.9027
L
2O
θ 1.42 min min min

Corrida 3

π π
Gv H =
( 4 ) D ( ) ( 1.08 m) ( 0.02m)
2

=
4
2

=0.0131
m 3
=13.0870
L
2O
θ 1.40 min min min

Corrida 4

π π
Gv H =
( 4 ) D ( ) ( 1.08 m) ( 0.02m)
2

=
4
2

=0.0187
m 3
=18.6957
L
2O
θ 0.98 min min min
Corrida 5

π π
Gv H =
( 4 ) D ( ) ( 1.08 m) ( 0.02m)
=
4
2

=0.0197
m
2

=19.7008
3
L
2O
θ 0.93 min min min

RECALIBRACIÓN DEL ROTÁMETRO CON OTROS FLUIDOS DE DENSIDADES DISTINTAS

L
Gv H Gv x =Gv del nuevo fluido [¿ ]
Gv x = 2O min
1 /2
7.02 ρx
( 8.02− ρx ) ρ x =Densidad del nuevo fluido

7.02=constante del medido proporcionado por el fabricante


8.02=Peso especifico del flotador

Fluido Tetracloruro de carbono

kg g
ρC Cl =1585 3
=1.585 3
m cm
4

Corrida 1

L
11.4511
Gv H min L
GvC Cl = 2O
= =8.7084
4
7.02 ρC Cl 1 /2
g 1 /2 min
( ) 7.02(1.585 3 )

( )
4

8.02−ρC Cl 4
cm
g
8.02−1.585 3
cm

Corrida 2
L
12.9027
Gv H min L
GvC Cl = 2O
= =9.8123
4
7.02 ρC Cl 1 /2
g 1 /2 min
( ) 7.02(1.585 3 )

( )
4

8.02−ρC Cl 4
cm
g
8.02−1.585 3
cm

Corrida 3
L
13.0870
Gv H min L
GvC Cl = 2O
= =9.9525
4
7.02 ρC Cl 1 /2
g 1 /2 min
( ) 7.02(1.585 3 )

( )
4

8.02−ρC Cl 4
cm
g
8.02−1.585 3
cm

Corrida 4
L
18.6957
Gv H min L
GvC Cl = 2O
= =14.2178
4
7.02 ρC Cl 1 /2
g 1 /2 min
( ) 7.02(1.585 3 )

( )
4

8.02−ρC Cl 4
cm
g
8.02−1.585 3
cm

Corrida 5
L
19.7008
Gv H min L
GvC Cl = 2O
= =14.9822
4
7.02 ρC Cl 1 /2
g 1 /2 min
( ) 7.02(1.585 3 )

( )
4

8.02−ρC Cl 4
cm
g
8.02−1.585 3
cm

Fluido Benceno
kg g
ρC H6 =878.6 3
=0.8786 3
m cm
6

Corrida 1
L
11.4511
Gv H min L
GvC H6 = 2O
= =12.3235
6
7.02 ρC H 1 /2
g 1 /2 min
( ) 7.02(0.8786 3 )

( )
6 6

8.02− ρC H 6 6
cm
g
8.02−0.8786 3
cm

Corrida 2
L
12.9027
Gv H min L
GvC H6 = 2O
= =13.8857
6
7.02 ρC H 1 /2
g 1 /2 min
( ) 7.02(0.8786 3 )

( )
6 6

8.02− ρC H 6 6
cm
g
8.02−0.8786 3
cm

Corrida 3
L
13.0870
Gv H min L
GvC H6 = 2O
= =14.0841
6
7.02 ρC H 1 /2
g 1 /2 min
( ) 7.02(0.8786 3 )

( )
6 6

8.02− ρC H 6 6
cm
g
8.02−0.8786 3
cm

Corrida 4
L
18.6957
Gv H min L
GvC H6 = 2O
= =20.1201
6
7.02 ρC H 1 /2
g 1 /2 min
( ) 7.02(0.8786 3 )

( )
6 6

8.02− ρC H 6 6
cm
g
8.02−0.8786 3
cm

Corrida 5
L
19.7008
Gv H min L
GvC H6 = 2O
= =21.2018
6
7.02 ρC H 1 /2
g 1 /2 min
( ) 7.02(0.8786 3 )

( )
6 6

8.02− ρC H 6 6
cm
g
8.02−0.8786 3
cm
CALCULO DEL COEFICIENTE DE DESCARGA DEL TUBO VENTURI
Cv=Gv ¿ ¿

d gv π d 2gv
β= Av=
D 4
D=diametro interiro de la tuberia=0.0508 m
d gv=Diametro dela garganta del tubo Venturi=0.0192 m
2
0.0192 m π (0.0192 m)
β= =0.3780 Av= =0.00029 m 2
0.0508 m 4

m 3 1 min m3
Gv H =0.0116
2O ( )
min 60 seg
=1.9333 x 10−4
seg
3 3
m 1 min m
Gv H 2O
=0.0129 (
min 60 seg ) =2.15 x 10−4
seg
3 3
m 1 min m
Gv H 2O
=0.0131 (
min 60 seg ) =2.1833 x 10 −4
seg
3 3
m 1 min m
Gv H 2O
=0.0187 (
min 60 seg ) =3.1167 x 10 −4
seg
3 3
m 1 min m
Gv H 2O
=0.0197 (
min 60 seg ) =3.2833 x 10 −4
seg

Corrida 1

−4 m3
Cv=(1.9333 x 10 ) ¿¿
seg
Corrida 2

−4 m3
Cv=(2.15 x 10 )¿¿
seg
Corrida 3

−4 m3
Cv=(2.1833 x 10 )¿ ¿
seg
Corrida 4

−4 m3
Cv=(3.1167 x 10 )¿ ¿
seg
Corrida 5

−4 m3
Cv=(3.2833 x 10 )¿¿
seg

CALCULO DEL COEFICIENTE DE DESCARGA DE LA PLACA DE ORIFICIO


Gv
Co= 1/2
Ao=3.976078 x 10−4 m 2
(2 g)(∆ H )( ρm −ρ H )
Ao
[ ρH 2O
2O

]
Corrida 1

m3
1.9333 x 10−4
seg
Co= 1 /2
=0.8554
m kg kg

3.976078 x 10−4 m2

Corrida 2
[ ( s )
998 3
kg
m
m (
2∗9.81 2 ( 0.028 m ) 1585 3 −998 3
m )
]
m3
2.15 x 10−4
seg
C o= 1
=0.9190
m kg kg

[ ( ) ( )
]
2
2∗9.81 2 ( 0.030 m ) 1585 3 −998 3
s m m
3.976078 x 10− 4 m2
kg
998 3
m

Corrida 3

m3
2.1833 x 10−4
seg
C o= 1
=0.9036
m kg kg

[ ( ) ( )
]
2
2∗9.81 2 ( 0.032 m) 1585 3 −998 3
s m m
3.976078 x 10− 4 m2
kg
998 3
m
Corrida 4

m3
3.1167 x 10−4
seg
C o= 1
=1.0119
m kg kg

[ ( ) ( )
]
2
2∗9.81 2 ( 0.052 m) 1585 3 −998 3
s m m
3.976078 x 10− 4 m2
kg
998 3
m

Corrida 5

m3
3.2833 x 10−4
seg
Co= 1
=0.9391
m kg kg

[ ( ) ( )
]
2
2∗9.81 2 ( 0.067 m ) 1585 3 −998 3
s m m
3.976078 x 10−4 m2
kg
998 3
m

Resultados de gastos volumétricos de agua y 2 fluidos diferentes


Corrida %R L L L
Gv H
min 2O ( )
GvC Cl
min 4 ( )GvC H
min 6 6 ( )
1 50 11.4511 8.7084 12.3235
2 60 12.9027 9.8123 13.8857
3 70 13.0870 9.9525 14.0841
4 80 18.6957 14.2178 20.1201
5 90 19.7008 14.9822 21.2018

Coeficientes de descarga de los medidores de flujo


Corrida %R m3 Cv Co
Gv H
seg 2O ( )
1 50 1.9333 x 10−4 0.8031 0.8444
2 60 2.15 x 10 −4
0.9047 0.9190
3 70 2.1833 x 10−4 0.7957 0.9036
4 80 3.1167 x 10−4 0.9804 1.0119
5 90 3.2833 x 10−4 0.9330 0.9391
Promedios 0.8855 0.9258

𝐺𝑣 de agua y de fluidos de ρ distinta vs %R


25

20
Fludo agua
Gv (L/min)

15
Fluido CCl4
10
Fluido C6H6
5

0
40 50 60 70 80 90 100
%R

Gv vs Cv, Co
1.05

0.95

0.9
Cv, Co

Tubo venturi
0.85 Placa de orificios

0.8

0.75

0.7
10 12 14 16 18 20 22
Gv (L/min)
CONCLUSIONES
Para la primera grafica se puede observar que para fluidos menos densos que el
agua se obtienen mayores gastos volumétricos y para los mas densos que el agua
son menores gastos, por lo que si se requiere un gasto mayor de un fluido mas
denso se pude subir su temperatura para disminuir su densidad y que se obtenga
un gasto similar al del agua
Los medidores de flujo tienen una importancia grande dentro de las instalaciones
de nuestros hogares y en las industrias, pueden ser de utilidad como vimos en la
práctica para medir y regular el gasto de acuerdo con las necesidades que se
requieran con una previa calibración que permita que el fluido fluya sin ningún
percance además evitando de esta manera que exista un sobreconsumo o
desaprovechamiento de recursos.
En el caso del tubo Venturi que usamos en la experimentación tiene una sección
reducida en el tubo lo cual permite reducir la presión y aumentar la velocidad de
un fluido y su principal además permite conocer la velocidad de los fluidos que se
transportan a través de sistemas de tuberías a partir de las diferencias de presión
que hay en tomas antes y después de la sección reducida. En este caso el
coeficiente del tubo Venturi fue muy cercano al rango que marcaba de 0.9 a 1
siendo el nuestro de forma experimental de 0.8855
Por otro lado, la placa de orificios fue el otro medidor de flujo que usamos, es
conocido por ser muy utilizado en la industria por su simpleza y economía de igual
forma que con el tubo Venturi hay una reducción en la sección de flujo de una
tubería, de modo que se produzca una caída de presión, y un aumento de la
velocidad. Para este medidor no obtuvimos el coeficiente marcado en la práctica,
pero se mencionó que el coeficiente de descarga puede cambiar con el tiempo
debido al desgaste y la acumulación de suciedad.

BIZARRO NAVA AXEL GIOVAN