Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Verificar la Longitud de desarrollo del acero en zapatas, del acero de la columna en la zapata.
Verificar la transferencia de carga de la columna a la zapata y de ser el caso , diseñar las barras de espera.
SOLUCION
DATOS:
a) PD= 159.00 T
b) PL= 125.00 T
c) S/C Tierra= 0.50 T/m2
d) (Ys+Yc)/2= 2.10 T/m3
e) σcp= 22.00 T/m2
f) C: 70cmx30cm ( 12 barras de 5/8´´)
g) F´c= 210.00 kg/cm2
F´c= 21.00 Mpa
Fy= 4200.00 kg/cm2
Fy= 420.00 Mpa
DF= 1.50 m
*DIMENSIONAMIENTO EN PLANTA
𝜎_█(𝑛𝑒𝑡𝑜@𝑎𝑑𝑚𝑖𝑠𝑖𝑏𝑙𝑒)=𝜎𝑐𝑝−[𝑝𝑒𝑠𝑜 𝑡𝑜𝑡𝑎𝑙 𝑑𝑒 𝑙𝑎
𝑠/𝑐𝑡𝑖𝑒𝑟𝑟𝑎]
Donde:
𝜎𝑐𝑝=𝐸𝑠𝑓𝑢𝑒𝑟𝑧𝑜 𝑎𝑑𝑚𝑖𝑠𝑖𝑏𝑙𝑒 𝑑𝑒𝑙 𝑠𝑢𝑒𝑙𝑜
𝝈_█(𝒏𝒆𝒕𝒐@𝒂𝒅𝒎𝒊𝒔𝒊𝒃𝒍𝒆)=𝝈𝒄𝒑− 𝑌_𝑠=𝑃𝑒𝑠𝑜 𝑒𝑠𝑝𝑒𝑐𝑖𝑓𝑖𝑐𝑜 𝑑𝑒𝑙 𝑠𝑢𝑒𝑙𝑜
[((𝒀_𝒔+𝒀_𝒄)/𝟐)∗𝑫_𝒇+𝒔/𝒄𝒕𝒊𝒆𝒓𝒓𝒂] 𝑌_𝑐=𝑃𝑒𝑠𝑜 𝑒𝑠𝑝𝑒𝑐𝑖𝑓𝑖𝑐𝑜 𝑑𝑒𝑙 𝑐𝑜𝑛𝑐𝑟𝑒𝑡𝑜
((𝑌_𝑠+𝑌_𝑐)/2)=𝑝𝑒𝑠𝑜 𝑝𝑟𝑜𝑚𝑒𝑑𝑖𝑜 𝑑𝑒 𝑠𝑢𝑒𝑙𝑜 𝑦 𝑐𝑜𝑛𝑐𝑟𝑒𝑡𝑜
𝐷_𝑓=𝑃𝑟𝑜𝑓𝑢𝑛𝑑𝑖𝑑𝑎𝑑 𝑑𝑒 𝑑𝑒𝑠𝑝𝑙𝑎𝑛𝑡𝑒
𝑠/𝑐𝑡𝑖𝑒𝑟𝑟𝑎=𝑆𝑜𝑏𝑟𝑒𝑐𝑎𝑟𝑔𝑎 𝑑𝑒 𝑡𝑖𝑒𝑟𝑟𝑎 𝑑𝑒 𝑠𝑒𝑟𝑣𝑖𝑐𝑖𝑜
Remplazando la ecuación tenemos:
Donde:
𝑨_𝒁=𝑷_𝑺/𝝈_█(𝒏𝒆𝒕𝒐@ → 𝑨_𝒁=(𝑷_𝑫+𝑷_𝑳)/𝝈_ 𝐴_𝑍=𝐴𝑟𝑒𝑎 𝑑𝑒 𝑙𝑎 𝑧𝑎𝑝𝑎𝑡𝑎
𝒂𝒅𝒎𝒊𝒔𝒊𝒃𝒍𝒆) █(𝒏𝒆𝒕𝒐@𝒂𝒅𝒎𝒊𝒔𝒊𝒃𝒍𝒆) 𝑃_𝑆=𝐶𝑎𝑟𝑔𝑎 𝑑𝑒 𝑠𝑒𝑟𝑣𝑖𝑐𝑖𝑜
𝑃_𝐷=𝐶𝑎𝑟𝑔𝑎 𝑚𝑢𝑒𝑟𝑡𝑎
𝑃_𝐿=𝐶𝑎𝑟𝑔𝑎 𝑣𝑖𝑣𝑎
𝑨_𝒁=(𝟏𝟓𝟗.𝟎 𝑻+𝟏𝟐𝟓
𝑻)/(𝟏𝟖.𝟑𝟓 𝑻/𝒎𝟐)
𝑨_𝒁= 15.48 m2
𝑳−𝒕=𝑩−𝒃
Consideramos → 𝑳= 4.20 m 4.20𝑚−0.70𝑚 = 3.80 𝑚−0.30 𝑚 𝑳𝒙𝑩>𝑨_𝒁
𝑩= 3.80 m 3.50 = 3.50 4.20 𝑚𝑥3.80 𝑚>15.48 𝑚2
15.96 m2 > 15.48 m2
OK, Si cumple
𝒒_𝒖=(𝟏.𝟒∗𝟏𝟓𝟗 𝑻+𝟏.𝟕∗𝟏𝟐𝟓
𝑻)/(𝟏𝟓.𝟗𝟔 𝒎𝟐) 𝒒_𝒖= 27.26 T/m2
Donde:
𝑽_𝒖𝒑≤∅𝑽_𝒄𝒑 𝑽_𝒖𝒑=𝑐𝑜𝑟𝑡𝑎𝑛𝑡𝑒 𝑢𝑙𝑡𝑖𝑚𝑎 𝑝𝑜𝑟 𝑝𝑢𝑛𝑧𝑜𝑛𝑎𝑚𝑖𝑒𝑛𝑡𝑜
𝑽_𝒄𝒑=𝑟𝑒𝑠𝑖𝑠𝑡𝑒𝑛𝑐𝑖𝑎 𝑑𝑒𝑙 𝑐𝑜𝑛𝑐𝑟𝑒𝑡𝑜 𝑎𝑙 𝑝𝑢𝑛𝑧𝑜𝑛𝑎𝑚𝑖𝑒𝑛𝑡𝑜
∅=0.85
Donde:
𝒃_𝟎=𝑝𝑒𝑟𝑖𝑚𝑒𝑡𝑟𝑜 𝑐𝑟𝑖𝑡𝑖𝑐𝑜
𝜷_𝒄=𝒕/𝒃 𝒃_𝟎=𝟐∗(𝒎+𝒏) 𝒎=𝒕+𝒅 𝜷_𝒄=𝑟𝑒𝑙𝑎𝑐𝑖𝑜𝑛 𝑒𝑛𝑡𝑟𝑒 𝑙𝑎 𝑚𝑎𝑦𝑜𝑟 𝑦 𝑚𝑒𝑛𝑜𝑟 𝑑𝑖𝑚𝑒𝑛𝑠𝑖𝑜𝑛 𝑑𝑒 𝑙𝑎 𝑐𝑜𝑙𝑢𝑚𝑛𝑎
d=peralte efectivo
t= lado mayor de la columna
𝒏=𝒃+𝒅 b= lado menor de la columna
𝒉_𝒛=𝑎𝑙𝑡𝑢𝑟𝑎 𝑑𝑒 𝑙𝑎 𝑧𝑎𝑝𝑎𝑡𝑎
𝒃_𝟎=𝟐∗(𝒎+𝒏) → 𝒃_𝟎=𝟐∗(𝟎.𝟕+𝒅+𝟎.𝟑+𝒅) 𝒃_𝟎=𝟐+𝟒𝒅
𝜷_𝒄=𝒕/𝒃 𝜷_𝒄=(𝟎.𝟕𝟎
→ 𝒎)/(𝟎.𝟑𝟎 𝒎) 𝜷_𝒄= 2.33>𝟐 dado que es mayor a 2, la cual se utiliza la siguiente ecuacion:
𝑽_𝑪𝑷=𝟎.𝟐𝟕∗(𝟐+𝟒/𝜷_𝒄 )∗√( 〖𝑭 ´ 〗 _𝒄 )
ACI Formula (11-35)
∗𝒃_𝟎∗𝒅
〖𝑽 _𝒖𝒑=𝑽
Igualamos:
〗 _𝑪𝑷
〖𝑷 _𝒖−𝒒_𝒖∗(𝟎.𝟕+𝒅)∗(𝟎.𝟑+𝒅)=𝟎.𝟐𝟕∗(𝟐+𝟒/𝜷_𝒄 )∗√( 〖𝑭 ´ 〗 _𝒄 )
∗𝒃_𝟎∗𝒅" " 〗 _
〖 435.1−27.26∗(0.7+𝑑)∗(0.3+𝑑)=0.27∗(2+4/2.33)∗√210∗10∗(2+4𝑑)∗𝑑" " 〗 _
435.1−27.26∗(0.21+1.0𝑑+1.0𝑑^2 )=145.49∗(2𝑑+4𝑑^2)
𝒉_𝒛>𝟐𝟓𝒅𝒃
435.1−5.72−27.26𝑑−27.26𝑑^2=290.98𝑑+581.96𝑑^2
𝟔𝟎𝟗.𝟐𝟐𝒅^𝟐+𝟑𝟏𝟖.𝟐𝟒𝒅−𝟒𝟐𝟗.𝟑𝟖=𝟎
𝒅= 0.62 m 𝒉_𝒛=𝒅+𝟗𝒄𝒎
ℎ_𝑧=62𝑐𝑚+9𝑐𝑚
𝒉_𝒛= 71.00 cm ≈ 0.71 m
Usamos: 𝒉_𝒛= 0.75 m
Entonces:
𝟕𝟓 𝒄𝒎=𝒅+𝟗𝒄𝒎
𝒅= 66.00 cm ≈ 0.66 m
𝑽_𝒖𝒅= 29.72 T
∅𝑉_𝒄=∅∗𝟎.𝟓𝟑√( 〖𝑭 ´ 〗 _𝒄 ) ∅=
∗𝒃_𝟎∗𝒅 0.85
∅𝑉_𝑐=0.85∗0.53√(210𝑘𝑔/𝑐𝑚^2 )∗10∗1.0𝑚∗0.66 m
𝑀_𝑢𝑚𝑎𝑥=27.26 𝑇/𝑚2∗1.00𝑚∗((1.75^2)/2)
𝐴_𝑠=𝑀_𝑢/ 𝑎=(𝐴_𝑠∗𝑓_𝑦)/
……….. (1) …………. (2)
(∅𝑓_𝑦∗(𝑑−𝑎/2)) (0.85∗𝑓_(´𝑐)∗𝑏)
𝐴_𝑠=𝑀_𝑢/(∅𝑓_𝑦∗(𝑑−((𝐴_𝑠∗𝑓_𝑦)/
(0.85∗𝑓_(´𝑐)∗𝑏))/2))
_Cuantia minima:
𝐴_𝑠𝒎𝒊𝒏=0.0018∗100𝑐𝑚∗66𝑐𝑚
𝐴_𝑠𝒎𝒊𝒏
= 11.88 cm^2
𝑆= 7.47 cm
𝑆=(2.85 𝑐𝑚^2)/(17.26
Area de 3/4"= 2.85 cm^2 𝑐𝑚^2 )∗100 𝑐𝑚
𝑆= 16.51 cm
considerar S=15.50 cm
_Numero de varillas:
𝑁°𝑣𝑎𝑟𝑖𝑙𝑙𝑎𝑠=𝐴_𝑠/𝐴_𝑏𝑎𝑟𝑟
𝑎
Area de 3/4"= 2.85 cm^2
𝑁°𝑣𝑎𝑟𝑖𝑙𝑙𝑎𝑠=(17.26𝑐𝑚^
2 )/(2.85 𝑐𝑚^2 )
∅ 3/4" @ 0.155
𝑁°𝑣𝑎𝑟𝑖𝑙𝑙𝑎𝑠=(17.26𝑐𝑚^
2 )/(2.85 𝑐𝑚^2 )
∅ 3/4" @ 0.155
𝑁°𝑣𝑎𝑟𝑖𝑙𝑙𝑎𝑠= 6.06
COLUMNA:
∅𝑃_𝑛𝑏=∅(0.85𝑓´𝑐∗𝐴_1) F´c= 210.00 kg/cm2
F´c= 0.21 T/cm2
𝑷_𝒖= 435.10 T
Entonces: ∅𝑷_𝒏𝒃<𝑷_𝒖
ZAPATA:
La resistencia al aplastamiento de la zapata se incrementa aplicando un factor igual a √(𝐴2/𝐴1)≤2
debido
a la mayor área de la zapata que permite una mayor distribución de la carga de la columna.
A1 es el área de la columna y A2 es el área en planta de la base inferior del la mayor pirámide, cono truncado o cuña que queda contenida en su
totalidad dentro del apoyo y que tiene por base superior el área cargada, y pendientes laterales de 1 en vertical por 2 en horizontal. Para la columna
de 70 cm × 30 cm. que apoya sobre la zapata rectangular de 4.20 m × 3.80 m,
∅𝑃_𝑛𝑏=√(𝐴2/𝐴1)(∅∗(0.85𝑓´𝑐∗𝐴_1
))
∅𝑃_𝑛𝑏= 524.79 T
𝑷_𝒖= 435.10 T
Entonces: ∅𝑷_𝒏𝒃<𝑷_𝒖
∅= 0.7
𝐴_𝑚𝑖𝑛=0.005∗𝑡∗𝑏
𝐴_𝑚𝑖𝑛=0.005∗70 𝑐𝑚∗30 𝑐𝑚
𝑆=(5.10 𝑐𝑚^2)/(58.74
Area de 1"= 5.10 cm^2 𝑐𝑚^2 )∗100 𝑐𝑚
𝑆= 8.68 cm
considerar S=7.50 cm
_Numero de varillas:
𝑁°𝑣𝑎𝑟𝑖𝑙𝑙𝑎𝑠=𝐴_𝑠/𝐴_𝑏𝑎𝑟𝑟
𝑎
Area de 1"= 5.10 cm^2
𝑁°𝑣𝑎𝑟𝑖𝑙𝑙𝑎𝑠=(58.74 𝑐𝑚^2
)/(5.10 𝑐𝑚^2 )
𝑁°𝑣𝑎𝑟𝑖𝑙𝑙𝑎𝑠= 11.52