Está en la página 1de 1

n m

k k
k
k
SALA DE INFORMES
N.P.T +3.55 k m m
k SALA DE CAPACITACIONES
SUM N.P.T +6.35
DEPOSITO 2 N.P.T +0.15
N.P.T +0.15

n m S(k)

S(k) S(n) m
j S.H n
N.P.T +3.55
S.H
N.P.T +3.55 S(k,m)
S(m,n) s S(m)

MAMOGRAFÍA ALMACÉN DE INSUMOS


DEPÓSITO 1 N.P.T +3.55 N.P.T +6.35
N.P.T +0.15 S(j) S(j)
j j l l s j l ECOGRAFIA s j l
S(s) N.P.T +3.55 S(s) PISO TÉCNICO
N.P.T
escalera de gato +6.35
S(l) S(l) S(l)
BAREBONE
N.P.T +0.15

S(j)
S(q) S(q)
BAREBONE BAREBONE
S(g) N.P.T +3.55 N.P.T +6.35
S(i)
q q
i
DENSITROMETRÍA
N.P.T +3.55 ALMACÉN DE INSUMOS
SALA DE REPOSO g f S(g) g S(r) r S(g) g S(r) r
N.P.T +6.35
N.P.T +0.15 i S(i) i S(i)
LIMPIEZA LIMPIEZA
PASADIZO Sube C-14 de T-G N.P.T +3.55 PASADIZO Sube C-14 de T-G N.P.T +6.35 Sube C-14 de T-G
N.P.T +0.15 para subtablero(TAA) N.P.T +3.55 para subtablero(TAA) para subtablero(TAA)
TOMOGRAFO PVC SAP Ø 25mm PVC SAP Ø 25mm PVC SAP Ø 25mm
S(d)

S(f)
h h h OFICINA
S.H S(h) TOMOGRAFÍA
S.H S(h) S(h) N.P.T +6.35
N.P.T +0.15 N.P.T +3.55
N.P.T +0.15 ARCHIVO
g g N.P.T +6.35 g f
Llega C-12 de T-G
Sube C-12 fde T-G f f
para subtablero(STD-2) para subtablero(STD-2)
PVC SAP Ø 40mm PVC SAP Ø 40mm
RAYOS X
PDU N.P.T +3.55
c S(c) c S(c) c S(c)
Sube C-13 de T-G S.H S(f) Sube C-13 de T-G S.H
ST-2 Sube C-13 de T-G

ST-1
S.H C-2
para subtablero(STD-3) Llega C-11 de T-G para subtablero(STD-3) para subtablero(STD-3)
T-G

N.P.T +0.15 Sube C-11 de T-G N.P.T +3.55


S(t)
N.P.T +6.35
C-1
para subtablero(STD-1) PVC SAP Ø 40mm para subtablero(STD-1) PVC SAP Ø 40mm d d PVC SAP Ø 40mm
C-1 C-1
S(d)
C-2 PVC SAP Ø 40mm d C-2 PVC SAP Ø 40mm
S(b) d S.H
tN.P.T VESTIDORES
e C-5 S(d) e S(d) +3.55 e N.P.T +6.35
p p
C-6 SALA DE CONTROL S(p) SALA DE CONTROL S(p)
b
RECEPCIÓN S.H S.H
N.P.T +0.15 N.P.T +3.55 N.P.T +6.35
N.P.T +0.15 N.P.T +3.55

S(n)
b

VENTAS
N.P.T +6.35

b e DUCTO PARA ASCENSOR


b e DUCTO DE ASCENSOR
n e DUCTO DE ASCENSOR
N.P.T +0.15 N.P.T +3.55 N.P.T +6.35

PROCESAMIENTO
N.P.T +3.55
S(e) S(e) S(e)

S(a) Sc(o) Sc(o) Sc(o)

SALA DE ESPERA
N.P.T +0.15 Sube al 4 nivel b
o HALL o o
1 PVC SAP Ø 25mm N.P.T +3.55
Sube control automatico Sube control automatico Sube control automatico
a a a tanque elevado b a a tanque elevado ADMINISTRACIÓN a a tanque elevado
N.P.T +6.35
PVC SAP Ø 20mm PVC SAP Ø 20mm PVC SAP Ø 20mm
(2) TOMA DE MUESTRAS (2) (2)
N.P.T +3.55
PAT-2
S(p) Electrobombas de 1.5 HP S(b)
(Agua de consumo) S(a) S(a,b)

p p p p p

INGRESO
N.P.T +0.15
F-1

PAT-1
Wh

JARDÍN VERTICAL
JARDÍN VERTICAL

ACOMETIDAS DE CONCESIONARIA 380/220V

PRIMER NIVEL SEGUNDO NIVEL


TERCER NIVEL

PROPIETARIO FECHA:

GUEIZA MARLENY NUÑEZ DEL AGUILA


ENERO-2021
PROYECTO:
COMERCIO-CENTRO DE AYUDA AL DIAGNÓSTICO
ESCALA:
ESPECIALIDAD
1/50
INSTALACIONES ELECTRICAS - ILUMINACIÓN 1°,2° Y 3° NIVEL

PLANO: LAMINA N°:


PRIMER Y SEGUNDO NIVEL

RESPONSABLE:

ARQ. JIMENA MIÑANO VASQUEZ


CAP: 18877
UBICACIÓN:

MZ Q-3 LOTE 14 SANTA VICTORIA


PROVINCIA CHICLAYO-DEPARTAMENTO LAMBAYEQUE
IE-01

También podría gustarte