Está en la página 1de 5

TABLE: Story Drifts

Story Load Case/Combo Direction Drift Label X Y Z


m m m
Story4 SISMOXX X 0.00078 7 11.3 10.3 10.4
Story3 SISMOXX X 0.000926 7 11.3 10.3 7.8
Story2 SISMOXX X 0.000916 7 11.3 10.3 5.2
Story1 SISMOXX X 0.000546 32 0.5 10.3 2.6
por er una estructura irregular, se usa 0.85, para regulares es 0.75
Story Load Case/ComboDirection Drift Según norma
Dr*0.85*R <0.005
Story4 SISMOXX X 0.00078 0.00179 si
Story3 SISMOXX X 0.000926 0.002125 si
Story2 SISMOXX X 0.000916 0.002102 si
Story1 SISMOXX X 0.000546 0.001253 si

Story Load Case/Combo Direction Drift Label X Y Z


m m m
Story4 SISMOYY Y 0.000459 10 11.3 0 10.4
Story3 SISMOYY Y 0.00057 10 11.3 0 7.8
Story2 SISMOYY Y 0.000617 10 11.3 0 5.2
Story1 SISMOYY Y 0.000426 10 11.3 0 2.6

Story Load Case/Combo


Direction Drift Según norma
Dr*0.85*R <0.005
Story4 SISMOYY Y 0.000459 0.001053 si
Story3 SISMOYY Y 0.00057 0.001308 si
Story2 SISMOYY Y 0.000617 0.001416 si
Story1 SISMOYY Y 0.000426 0.000978 si

FINALIZA EL ANALISIS ESTATICO, Y SE CONTINUA CON EL DISEÑO


TABLE: Story Drifts
Story Load Case/Combo Direction Drift Label X Y Z
m m m
Story4 SISMOXX Max X 0.001 4 0 0 10.4
Story3 SISMOXX Max X 0.001 7 11.3 10.3 7.8
Story2 SISMOXX Max X 0.001 7 11.3 10.3 5.2
Story1 SISMOXX Max X 0 32 0.5 10.3 2.6

Story Load Case/Combo Direction Drift Label X Y Z


m m m
Story4 SISMOYY Max Y 0 10 11.3 0 10.4
Story3 SISMOYY Max Y 0 10 11.3 0 7.8
Story2 SISMOYY Max Y 0 10 11.3 0 5.2
Story1 SISMOYY Max Y 0 10 11.3 0 2.6

Story Load Case/Combo Location P VX VY T MX


kgf kgf kgf kgf-m kgf-m
Story1 SISMOXX Max Bottom 0 181098.58 43868.67 1168070.66 333617.91
Story1 SISMOYY Max Bottom 0 43868.67 186850.33 970851.66 1394832.69

Story Load Case/Combo Location P VX VY T MX


kgf kgf kgf kgf-m kgf-m
Story1 SISMOXX Max Bottom 0 237240.77 57468.35 1530183.08 437042.46
Story1 SISMOYY Max Bottom 0 55713.45 237300.96 1232986.98 1771445.23
MY
kgf-m
1368769.12
331705.01

MY
kgf-m
1793099.86
421267.19

También podría gustarte