m m m Story4 SISMOXX X 0.00078 7 11.3 10.3 10.4 Story3 SISMOXX X 0.000926 7 11.3 10.3 7.8 Story2 SISMOXX X 0.000916 7 11.3 10.3 5.2 Story1 SISMOXX X 0.000546 32 0.5 10.3 2.6 por er una estructura irregular, se usa 0.85, para regulares es 0.75 Story Load Case/ComboDirection Drift Según norma Dr*0.85*R <0.005 Story4 SISMOXX X 0.00078 0.00179 si Story3 SISMOXX X 0.000926 0.002125 si Story2 SISMOXX X 0.000916 0.002102 si Story1 SISMOXX X 0.000546 0.001253 si
Story Load Case/Combo Direction Drift Label X Y Z
m m m Story4 SISMOYY Y 0.000459 10 11.3 0 10.4 Story3 SISMOYY Y 0.00057 10 11.3 0 7.8 Story2 SISMOYY Y 0.000617 10 11.3 0 5.2 Story1 SISMOYY Y 0.000426 10 11.3 0 2.6
Story Load Case/Combo
Direction Drift Según norma Dr*0.85*R <0.005 Story4 SISMOYY Y 0.000459 0.001053 si Story3 SISMOYY Y 0.00057 0.001308 si Story2 SISMOYY Y 0.000617 0.001416 si Story1 SISMOYY Y 0.000426 0.000978 si
FINALIZA EL ANALISIS ESTATICO, Y SE CONTINUA CON EL DISEÑO
TABLE: Story Drifts Story Load Case/Combo Direction Drift Label X Y Z m m m Story4 SISMOXX Max X 0.001 4 0 0 10.4 Story3 SISMOXX Max X 0.001 7 11.3 10.3 7.8 Story2 SISMOXX Max X 0.001 7 11.3 10.3 5.2 Story1 SISMOXX Max X 0 32 0.5 10.3 2.6
Story Load Case/Combo Direction Drift Label X Y Z
m m m Story4 SISMOYY Max Y 0 10 11.3 0 10.4 Story3 SISMOYY Max Y 0 10 11.3 0 7.8 Story2 SISMOYY Max Y 0 10 11.3 0 5.2 Story1 SISMOYY Max Y 0 10 11.3 0 2.6