ENSAYO DE PERMEABILIDAD DE AGUA A

Golder Associates PRESION TIPO LUGEON


Perú S.A.
SONDAJE Nº PIE-CHK-03-Q161 ENSAYO Nº COORD. NORTE:

PROYECTO : Polishing Pond Dam Raise PROF. DE ENSAYO DE : 41.00 A 48.00 m. COORD. ESTE:
UBICACIÓN: Polishing Pond FECHA : 6/30/2017 Hr.INIC. 10:21 FIN : 11:07 INCLINACIÓN: 90
CÓDIGO: COTA (m.s.n.m.):
LITOLOG. DEL TRAMO :

CAUDALIMETRO
Long. Min.
hm = ALTURA DEL MANOMETRO 1.50 m
MANOMETRO 1.00 m a = ALTURA SOBRE NIVEL DEL TERRENO 0.00 m
Cilindro de
Expansión ha = PROFUNDIDAD NIVEL FREATICO 16.50 m
Dh = SOBRECARGA HIDRAULICA 18.00 m
Bomba
d = PROFUNDIDAD DEL OBTURADOR 41.00 m
hm L = PROFUNDIDAD DE PERFORACION 48.00 m
Dh 90
a a = INCLINACION C/HORIZONTAL °
Dh' = Dh CORREGIDA = Sen a x Dh 18.00 m
ha
l = LONGITUD TRAMO DE ENSAYO 7.00 m
Ø = DIAMETRO DEL BULBO DEL ENSAYO 9.60 cm
d Dh PM = PRESION MANOMETRICA
L PEF = PRESION EFECTIVA EN EL PUNTO MEDIO DEL TRAMO DEL ENSAYO
ha Dp = PERDIDAS DE CARGA
q = VOLUMEN DE AGUA EN LITROS POR MINUTO DURANTE EL ENSAYO
qt = VOLUMEN TOTAL DE AGUA EN LITROS PARA CADA ESTADIO
l G = CAUDAL EN LITROS POR MINUTO PARA CADA ESTADIO
l/2
Q = CAUDAL EN LITROS POR MINUTO POR Mt. DE TRAMO DE ENSAYO
UL = UNIDAD LUGEON ( Q x 10 / P EF )
Ø

Bars Bars Bars Bars Bars


PM = 2.60 PM = 5.33 PM = 8.00 PM = 5.33 PM = 2.60 GRAFICO DE PATRON DE RESULTADOS
TIEMPO PARA LA SELECCIÓN DE UNIDADES
EN LECTURA LECTURA LECTURA LECTURA LECTURA
LUGEON
MINUTO CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l)

0 0.31 5.00 20.00 35.50 41.94


U.L.
0.0 0.5 1.0 1.5 2.0 2.5 3.0
1 0.44 0.13 5.98 0.98 21.98 1.98 36.63 1.13 41.94 0.00
ESTADIO

2 0.44 0.00 7.24 1.26 23.85 1.87 37.95 1.32 41.94 0.00 1

3 0.44 0.00 8.23 0.99 25.71 1.86 39.04 1.09 41.94 0.00
4 0.44 0.00 9.30 1.07 27.36 1.65 40.25 1.21 41.94 0.00 2

5 0.44 0.00 10.07 0.77 29.34 1.98 41.35 1.10 41.94 0.00
3
6 11.13 1.06 31.14 1.80
7 33.00 1.86
4
8
9
5
10
qt(l)
G ( l/min ) 0.03 1.02 1.86 1.17 0.00
Q ( l/min/m ) 0.00 0.15 0.27 0.17 0.00 UNIDAD LUGEON SELECCIONADA : 0.2 UL
Dp ( bars )
PEF ( bars ) 4.37 7.10 9.77 7.10 4.37 K (PERMEABILIDAD) : 3.1E-08 m/s
K (m/sec) 1.1E-09 2.7E-08 3.5E-08 3.1E-08 0.0E+00
UL 0.01 0.21 0.27 0.24 0.00
1 2 3 4 5
PEF = PM - Dp + Dh / 10.197 UL = Q (L/min/m) x 10 / P EF (bars)

REPRESENTACION GRAFICA
Dilatación/ Laminar
Q (Lpm/m)

1.0 OBSERVACIONES:
0.9 Packer simple - 30 bar
0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0
4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0
PEF (bars)
Golder Cosapi Geotecnia
ENSAYO DE PERMEABILIDAD DE AGUA A
Golder Associates PRESION TIPO LUGEON
Perú S.A.
SONDAJE Nº PIE-CHK-03-Q161 ENSAYO Nº COORD. NORTE:

PROYECTO : Polishing Pond Dam Raise PROF. DE ENSAYO DE : 36.00 A 41.00 m. COORD. ESTE:
UBICACIÓN: Polishing Pond FECHA : 6/29/2017 Hr.INIC. 5:09 FIN : 5:41 INCLINACIÓN: 90
CÓDIGO: COTA (m.s.n.m.):
LITOLOG. DEL TRAMO :

CAUDALIMETRO
Long. Min.
hm = ALTURA DEL MANOMETRO 1.00 m
MANOMETRO 1.00 m a = ALTURA SOBRE NIVEL DEL TERRENO 0.00 m
Cilindro de
Expansión ha = PROFUNDIDAD NIVEL FREATICO 12.50 m
Dh = SOBRECARGA HIDRAULICA 13.50 m
Bomba
d = PROFUNDIDAD DEL OBTURADOR 36.00 m
hm L = PROFUNDIDAD DE PERFORACION 41.00 m
Dh a = INCLINACION C/HORIZONTAL 90 °
a

Dh' = Dh CORREGIDA = Sen a x Dh 13.50 m


ha
l = LONGITUD TRAMO DE ENSAYO 5.00 m
Ø = DIAMETRO DEL BULBO DEL ENSAYO 9.60 cm
d Dh PM = PRESION MANOMETRICA
L PEF = PRESION EFECTIVA EN EL PUNTO MEDIO DEL TRAMO DEL ENSAYO
ha Dp = PERDIDAS DE CARGA
q = VOLUMEN DE AGUA EN LITROS POR MINUTO DURANTE EL ENSAYO
qt = VOLUMEN TOTAL DE AGUA EN LITROS PARA CADA ESTADIO
l G = CAUDAL EN LITROS POR MINUTO PARA CADA ESTADIO
l/2 Q = CAUDAL EN LITROS POR MINUTO POR Mt. DE TRAMO DE ENSAYO
UL = UNIDAD LUGEON ( Q x 10 / P EF )
Ø

Bars Bars Bars Bars Bars


PM = 2.56 PM = 5.13 PM = 7.70 PM = 5.13 PM = 2.56 GRAFICO DE PATRON DE RESULTADOS
TIEMPO PARA LA SELECCIÓN DE UNIDADES
EN LECTURA LECTURA LECTURA LECTURA LECTURA LUGEON
MINUTO CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l)

0 0.00 0.36 0.41 0.57 0.61 U.L.


0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
1 0.00 0.00 0.36 0.00 0.41 0.00 0.57 0.00 0.61 0.00
2 0.00 0.00 0.36 0.00 0.44 0.03 0.57 0.00 0.61 0.00
ESTADIO

3 0.00 0.00 0.36 0.00 0.52 0.08 0.57 0.00 0.61 0.00
4 0.00 0.00 0.36 0.00 0.57 0.05 0.57 0.00 0.61 0.00 2

5 0.00 0.00 0.36 0.00 0.57 0.00 0.57 0.00 0.61 0.00
3
6
7
4
8
9
5
10
qt(l)
G ( l/min ) 0.00 0.00 0.03 0.00 0.00
Q ( l/min/m ) 0.00 0.00 0.01 0.00 0.00 UNIDAD LUGEON SELECCIONADA : 0.0 UL
Dp ( bars )
PEF ( bars ) 3.88 6.46 9.02 6.46 3.88 K (PERMEABILIDAD) : 8.6E-10 m/s
K (m/sec) 0.0E+00 0.0E+00 8.6E-10 0.0E+00 0.0E+00
UL 0.00 0.00 0.01 0.00 0.00
1 2 3 4 5
PEF = PM - Dp + Dh / 10.197 UL = Q (L/min/m) x 10 / P EF (bars)

REPRESENTACION GRAFICA
OBSERVACIONES: Baja Permeabilidad
Q (Lpm/m)

1.0

0.9 Packer simple - 30 bar


0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0
3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
PEF (bars)
Golder Cosapi Geotecnia
ENSAYO DE PERMEABILIDAD DE AGUA A
Golder Associates PRESION TIPO LUGEON
Perú S.A.
SONDAJE Nº WC-P24-C2 COORD. NORTE: 8942420.527
PROYECTO : Polishing Pond Dam Raise PROF. DE ENSAYO DE : 27.60 A 32.60 m. COORD. ESTE: 279366.443
UBICACIÓN: Polishing Pond FECHA : 6/30/2017 Hr.INIC. 14:25 FIN : 15:45 INCLINACIÓN: 90
CÓDIGO: COTA (m.s.n.m.): 4120.3
LITOLOG. DEL TRAMO :

CAUDALIMETRO
Long. Min.
hm = ALTURA DEL MANOMETRO 1.00 m
MANOMETRO 1.00 m a = ALTURA SOBRE NIVEL DEL TERRENO 0.00 m
Cilindro de
Expansión ha = PROFUNDIDAD NIVEL FREATICO 28.40 m
Dh = SOBRECARGA HIDRAULICA 29.40 m
Bomba
d = PROFUNDIDAD DEL OBTURADOR 27.60 m
hm L = PROFUNDIDAD DE PERFORACION 32.60 m
Dh a = INCLINACION C/HORIZONTAL 90 °
a

Dh' = Dh CORREGIDA = Sen a x Dh 29.40 m


ha
l = LONGITUD TRAMO DE ENSAYO 5.00 m
Ø = DIAMETRO DEL BULBO DEL ENSAYO 11.50 cm
d Dh PM = PRESION MANOMETRICA
L PEF = PRESION EFECTIVA EN EL PUNTO MEDIO DEL TRAMO DEL ENSAYO
ha Dp = PERDIDAS DE CARGA
q = VOLUMEN DE AGUA EN LITROS POR MINUTO DURANTE EL ENSAYO
qt = VOLUMEN TOTAL DE AGUA EN LITROS PARA CADA ESTADIO
l G = CAUDAL EN LITROS POR MINUTO PARA CADA ESTADIO
l/2 Q = CAUDAL EN LITROS POR MINUTO POR Mt. DE TRAMO DE ENSAYO
UL = UNIDAD LUGEON ( Q x 10 / P EF )
Ø

Bars Bars Bars Bars Bars


PM = 2.00 PM = 4.00 PM = 6.00 PM = 4.00 PM = 2.00 GRAFICO DE PATRON DE RESULTADOS
TIEMPO PARA LA SELECCIÓN DE UNIDADES
EN LECTURA LECTURA LECTURA LECTURA LECTURA LUGEON
MINUTO CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l)

0 72.08 44.00 60.00 60.00 80.00 U.L.


0.0 2.0 4.0 6.0 8.0
1 86.99 14.91 75.00 31.00 111.00 51.00 87.00 27.00 94.01 14.01
2 102.01 15.02 106.00 31.00 162.00 51.00 115.00 28.00 108.16 14.15
ESTADIO

3 116.16 14.15 136.00 30.00 212.00 50.00 144.00 29.00 122.16 14.00
4 130.49 14.33 167.00 31.00 262.00 50.00 174.00 30.00 137.22 15.06 2

5 144.51 14.02 197.00 30.00 313.00 51.00 204.00 30.00 151.98 14.76
3
6
7
4
8
9
5
10
qt(l)
G ( l/min ) 14.49 30.60 50.60 28.80 14.40
Q ( l/min/m ) 2.90 6.12 10.12 5.76 2.88 UNIDAD LUGEON SELECCIONADA : 8.4 UL
Dp ( bars )
PEF ( bars ) 4.88 6.88 8.88 6.88 4.88 K (PERMEABILIDAD) : 9.7E-07 m/s
K (m/sec) 6.9E-07 1.0E-06 1.3E-06 9.7E-07 6.8E-07
UL 5.93 8.89 11.39 8.37 5.90
1 2 3 4 5
PEF = PM - Dp + Dh / 10.197 UL = Q (L/min/m) x 10 / P EF (bars)

REPRESENTACION GRAFICA
OBSERVACIONES: Flujo Dilatación
Q (Lpm/m)

11.0 Packer doble - 30 bar

9.0

7.0

5.0

3.0

1.0
4.0 5.0 6.0 7.0 8.0 9.0 10.0
PEF (bars)
Golder
ENSAYO DE PERMEABILIDAD DE AGUA A
Golder Associates PRESION TIPO LUGEON
Perú S.A.
SONDAJE Nº WC-P24-C2 ENSAYO Nº COORD. NORTE: 8942420.527
PROYECTO : Polishing Pond Dam Raise PROF. DE ENSAYO DE : 32.60 A 37.60 m. COORD. ESTE: 279366.443
UBICACIÓN: Polishing Pond FECHA : 6/30/2017 Hr.INIC. 13:39 FIN : 14:11 INCLINACIÓN: 90
CÓDIGO: COTA (m.s.n.m.): 4120.3
LITOLOG. DEL TRAMO :

CAUDALIMETRO
Long. Min.
hm = ALTURA DEL MANOMETRO 1.00 m
MANOMETRO 1.00 m a = ALTURA SOBRE NIVEL DEL TERRENO 0.00 m
Cilindro de
Expansión ha = PROFUNDIDAD NIVEL FREATICO 28.40 m
Dh = SOBRECARGA HIDRAULICA 29.40 m
Bomba
d = PROFUNDIDAD DEL OBTURADOR 32.60 m
hm L = PROFUNDIDAD DE PERFORACION 37.60 m
Dh 90
a a = INCLINACION C/HORIZONTAL °
Dh' = Dh CORREGIDA = Sen a x Dh 29.40 m
ha
l = LONGITUD TRAMO DE ENSAYO 5.00 m
Ø = DIAMETRO DEL BULBO DEL ENSAYO 11.50 cm
d Dh PM = PRESION MANOMETRICA
L PEF = PRESION EFECTIVA EN EL PUNTO MEDIO DEL TRAMO DEL ENSAYO
ha Dp = PERDIDAS DE CARGA
q = VOLUMEN DE AGUA EN LITROS POR MINUTO DURANTE EL ENSAYO
qt = VOLUMEN TOTAL DE AGUA EN LITROS PARA CADA ESTADIO
l G = CAUDAL EN LITROS POR MINUTO PARA CADA ESTADIO
l/2
Q = CAUDAL EN LITROS POR MINUTO POR Mt. DE TRAMO DE ENSAYO
UL = UNIDAD LUGEON ( Q x 10 / P EF )
Ø

Bars Bars Bars Bars Bars


PM = 2.30 PM = 4.67 PM = 7.00 PM = 4.67 PM = 2.30 GRAFICO DE PATRON DE RESULTADOS
TIEMPO PARA LA SELECCIÓN DE UNIDADES
EN LECTURA LECTURA LECTURA LECTURA LECTURA
LUGEON
MINUTO CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l)

0 0.00 0.96 2.80 8.05 8.05


U.L.
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
1 0.00 0.00 1.11 0.15 3.80 1.00 8.05 0.00 8.05 0.00
ESTADIO

2 0.00 0.00 1.24 0.13 4.79 0.99 8.05 0.00 8.05 0.00 1

3 0.00 0.00 1.29 0.05 5.76 0.97 8.05 0.00 8.05 0.00
4 0.00 0.00 1.30 0.01 6.74 0.98 8.05 0.00 8.05 0.00 2

5 0.00 0.00 1.33 0.03 7.70 0.96 8.05 0.00 8.05 0.00
3
6
7
4
8
9
5
10
qt(l)
G ( l/min ) 0.00 0.07 0.98 0.00 0.00
Q ( l/min/m ) 0.00 0.01 0.20 0.00 0.00 UNIDAD LUGEON SELECCIONADA : 0.1 UL
Dp ( bars )
PEF ( bars ) 5.18 7.55 9.88 7.55 5.18 K (PERMEABILIDAD) : 1.3E-08 m/s
K (m/sec) 0.0E+00 2.3E-09 2.3E-08 0.0E+00 0.0E+00
UL 0.00 0.02 0.20 0.00 0.00
1 2 3 4 5
PEF = PM - Dp + Dh / 10.197 UL = Q (L/min/m) x 10 / P EF (bars)

REPRESENTACION GRAFICA
Baja Permeabilidad
Q (Lpm/m)

0.25 OBSERVACIONES:
Packer simple - 30 bar
0.20

0.15

0.10

0.05

0.00
4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0
PEF (bars)
Golder
ENSAYO DE PERMEABILIDAD DE AGUA A
Golder Associates PRESION TIPO LUGEON
Perú S.A.
SONDAJE Nº PIE-CHK-03-Q161 ENSAYO Nº COORD. NORTE:

PROYECTO : Polishing Pond Dam Raise PROF. DE ENSAYO DE : 21.00 A 26.00 m. COORD. ESTE:
UBICACIÓN: Polishing Pond FECHA : 6/29/2017 Hr.INIC. 23:06 FIN : 23:37 INCLINACIÓN: 90
CÓDIGO: COTA (m.s.n.m.):
LITOLOG. DEL TRAMO :

CAUDALIMETRO
Long. Min.
hm = ALTURA DEL MANOMETRO 1.00 m
MANOMETRO 1.00 m a = ALTURA SOBRE NIVEL DEL TERRENO 0.00 m
Cilindro de
Expansión ha = PROFUNDIDAD NIVEL FREATICO 11.80 m
Dh = SOBRECARGA HIDRAULICA 12.80 m
Bomba
d = PROFUNDIDAD DEL OBTURADOR 21.00 m
hm L = PROFUNDIDAD DE PERFORACION 26.00 m
Dh a = INCLINACION C/HORIZONTAL 90 °
a

Dh' = Dh CORREGIDA = Sen a x Dh 12.80 m


ha
l = LONGITUD TRAMO DE ENSAYO 5.00 m
Ø = DIAMETRO DEL BULBO DEL ENSAYO 9.60 cm
d Dh PM = PRESION MANOMETRICA
L PEF = PRESION EFECTIVA EN EL PUNTO MEDIO DEL TRAMO DEL ENSAYO
ha Dp = PERDIDAS DE CARGA
q = VOLUMEN DE AGUA EN LITROS POR MINUTO DURANTE EL ENSAYO
qt = VOLUMEN TOTAL DE AGUA EN LITROS PARA CADA ESTADIO
l G = CAUDAL EN LITROS POR MINUTO PARA CADA ESTADIO
l/2 Q = CAUDAL EN LITROS POR MINUTO POR Mt. DE TRAMO DE ENSAYO
UL = UNIDAD LUGEON ( Q x 10 / P EF )
Ø

Bars Bars Bars Bars Bars


PM = 1.56 PM = 3.13 PM = 4.70 PM = 3.13 PM = 1.56 GRAFICO DE PATRON DE RESULTADOS
TIEMPO PARA LA SELECCIÓN DE UNIDADES
EN LECTURA LECTURA LECTURA LECTURA LECTURA LUGEON
MINUTO CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l)

0 5.16 6.41 6.85 6.85 6.85 U.L.


0.0 0.5 1.0 1.5 2.0 2.5 3.0
1 5.16 0.00 6.41 0.00 6.85 0.00 6.85 0.00 6.85 0.00
2 5.16 0.00 6.41 0.00 6.85 0.00 6.85 0.00 6.85 0.00
ESTADIO

3 5.16 0.00 6.41 0.00 6.85 0.00 6.85 0.00 6.85 0.00
4 5.16 0.00 6.41 0.00 6.85 0.00 6.85 0.00 6.85 0.00 2

5 5.16 0.00 6.41 0.00 6.85 0.00 6.85 0.00 6.85 0.00
3
6
7
4
8
9
5
10
qt(l)
G ( l/min ) 0.00 0.00 0.00 0.00 0.00
Q ( l/min/m ) 0.00 0.00 0.00 0.00 0.00 UNIDAD LUGEON SELECCIONADA : 0.0 UL
Dp ( bars )
PEF ( bars ) 2.82 4.39 5.96 4.39 2.82 K (PERMEABILIDAD) : 0.0E+00 m/s
K (m/sec) 0.0E+00 0.0E+00 0.0E+00 0.0E+00 0.0E+00
UL 0.00 0.00 0.00 0.00 0.00
1 2 3 4 5
PEF = PM - Dp + Dh / 10.197 UL = Q (L/min/m) x 10 / P EF (bars)

REPRESENTACION GRAFICA
OBSERVACIONES: Tramo Impermeable
Q (Lpm/m)

1.0

0.9 Packer simple - 30 bar


0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0
2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5
PEF (bars)
Golder Cosapi Geotecnia
ENSAYO DE PERMEABILIDAD DE AGUA A
Golder Associates PRESION TIPO LUGEON
Perú S.A.
SONDAJE Nº PIE-CHK-03-Q161 ENSAYO Nº COORD. NORTE:

PROYECTO : Polishing Pond Dam Raise PROF. DE ENSAYO DE : 16.00 A 21.00 m. COORD. ESTE:
UBICACIÓN: Polishing Pond FECHA : 6/29/2017 Hr.INIC. 21:05 FIN : 21:37 INCLINACIÓN: 90
CÓDIGO: COTA (m.s.n.m.):
LITOLOG. DEL TRAMO :

CAUDALIMETRO
Long. Min.
hm = ALTURA DEL MANOMETRO 1.00 m
MANOMETRO 1.00 m a = ALTURA SOBRE NIVEL DEL TERRENO 0.00 m
Cilindro de
Expansión ha = PROFUNDIDAD NIVEL FREATICO 11.40 m
Dh = SOBRECARGA HIDRAULICA 12.40 m
Bomba
d = PROFUNDIDAD DEL OBTURADOR 16.00 m
hm L = PROFUNDIDAD DE PERFORACION 21.00 m
Dh a = INCLINACION C/HORIZONTAL 90 °
a

Dh' = Dh CORREGIDA = Sen a x Dh 12.40 m


ha
l = LONGITUD TRAMO DE ENSAYO 5.00 m
Ø = DIAMETRO DEL BULBO DEL ENSAYO 9.60 cm
d Dh PM = PRESION MANOMETRICA
L PEF = PRESION EFECTIVA EN EL PUNTO MEDIO DEL TRAMO DEL ENSAYO
ha Dp = PERDIDAS DE CARGA
q = VOLUMEN DE AGUA EN LITROS POR MINUTO DURANTE EL ENSAYO
qt = VOLUMEN TOTAL DE AGUA EN LITROS PARA CADA ESTADIO
l G = CAUDAL EN LITROS POR MINUTO PARA CADA ESTADIO
l/2 Q = CAUDAL EN LITROS POR MINUTO POR Mt. DE TRAMO DE ENSAYO
UL = UNIDAD LUGEON ( Q x 10 / P EF )
Ø

Bars Bars Bars Bars Bars


PM = 1.23 PM = 2.47 PM = 3.70 PM = 2.47 PM = 1.23 GRAFICO DE PATRON DE RESULTADOS
TIEMPO PARA LA SELECCIÓN DE UNIDADES
EN LECTURA LECTURA LECTURA LECTURA LECTURA LUGEON
MINUTO CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l)

0 0.00 2.25 3.32 3.75 3.75 U.L.


0.0 0.5 1.0 1.5 2.0 2.5 3.0
1 0.00 0.00 2.25 0.00 3.32 0.00 3.75 0.00 3.75 0.00
2 0.00 0.00 2.25 0.00 3.32 0.00 3.75 0.00 3.75 0.00
ESTADIO

3 0.00 0.00 2.25 0.00 3.32 0.00 3.75 0.00 3.75 0.00
4 0.00 0.00 2.25 0.00 3.32 0.00 3.75 0.00 3.75 0.00 2

5 0.00 0.00 2.25 0.00 3.32 0.00 3.75 0.00 3.75 0.00
3
6
7
4
8
9
5
10
qt(l)
G ( l/min ) 0.00 0.00 0.00 0.00 0.00
Q ( l/min/m ) 0.00 0.00 0.00 0.00 0.00 UNIDAD LUGEON SELECCIONADA : 0.0 UL
Dp ( bars )
PEF ( bars ) 2.45 3.68 4.92 3.68 2.45 K (PERMEABILIDAD) : 0.0E+00 m/s
K (m/sec) 0.0E+00 0.0E+00 0.0E+00 0.0E+00 0.0E+00
UL 0.00 0.00 0.00 0.00 0.00
1 2 3 4 5
PEF = PM - Dp + Dh / 10.197 UL = Q (L/min/m) x 10 / P EF (bars)

REPRESENTACION GRAFICA
OBSERVACIONES: Tramo Impermeable
Q (Lpm/m)

1.0

0.9 Packer simple - 30 Bar


0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0
2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
PEF (bars)
Golder Cosapi Geotecnia
ENSAYO DE PERMEABILIDAD DE AGUA A
Golder Associates PRESION TIPO LUGEON
Perú S.A.
SONDAJE Nº PIE-CHK-03-Q161 ENSAYO Nº COORD. NORTE:

PROYECTO : Polishing Pond Dam Raise PROF. DE ENSAYO DE : 1.00 A 6.00 m. COORD. ESTE:
UBICACIÓN: Polishing Pond FECHA : 6/29/2017 Hr.INIC. 13:30 FIN : 14:06 INCLINACIÓN: 90
CÓDIGO: COTA (m.s.n.m.):
LITOLOG. DEL TRAMO :

CAUDALIMETRO
Long. Min.
hm = ALTURA DEL MANOMETRO 1.50 m
MANOMETRO 1.00 m a = ALTURA SOBRE NIVEL DEL TERRENO 0.00 m
Cilindro de
Expansión ha = PROFUNDIDAD NIVEL FREATICO 2.00 m
Dh = SOBRECARGA HIDRAULICA 3.50 m
Bomba
d = PROFUNDIDAD DEL OBTURADOR 1.00 m
hm L = PROFUNDIDAD DE PERFORACION 6.00 m
Dh a = INCLINACION C/HORIZONTAL 90 °
a

Dh' = Dh CORREGIDA = Sen a x Dh 3.50 m


ha
l = LONGITUD TRAMO DE ENSAYO 5.00 m
Ø = DIAMETRO DEL BULBO DEL ENSAYO 9.60 cm
d Dh PM = PRESION MANOMETRICA
L PEF = PRESION EFECTIVA EN EL PUNTO MEDIO DEL TRAMO DEL ENSAYO
ha Dp = PERDIDAS DE CARGA
q = VOLUMEN DE AGUA EN LITROS POR MINUTO DURANTE EL ENSAYO
qt = VOLUMEN TOTAL DE AGUA EN LITROS PARA CADA ESTADIO
l G = CAUDAL EN LITROS POR MINUTO PARA CADA ESTADIO
l/2 Q = CAUDAL EN LITROS POR MINUTO POR Mt. DE TRAMO DE ENSAYO
UL = UNIDAD LUGEON ( Q x 10 / P EF )
Ø

Bars Bars Bars Bars Bars


PM = 0.23 PM = 0.47 PM = 0.70 PM = 0.47 PM = 0.23 GRAFICO DE PATRON DE RESULTADOS
TIEMPO PARA LA SELECCIÓN DE UNIDADES
EN LECTURA LECTURA LECTURA LECTURA LECTURA LUGEON
MINUTO CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l)

0 6.95 18.48 19.50 19.64 19.78 U.L.


0.0 0.5 1.0 1.5 2.0 2.5 3.0
1 6.95 0.00 18.51 0.03 19.52 0.02 19.66 0.02 19.80 0.02
2 6.95 0.00 18.54 0.03 19.54 0.02 19.68 0.02 19.82 0.02
ESTADIO

3 6.96 0.01 18.56 0.02 19.56 0.02 19.70 0.02 19.84 0.02
4 6.97 0.01 18.59 0.03 19.58 0.02 19.72 0.02 19.87 0.03 2

5 6.99 0.02 18.61 0.02 19.61 0.03 19.74 0.02 19.90 0.03
3
6
7
4
8
9
5
10
qt(l)
G ( l/min ) 0.01 0.03 0.02 0.02 0.02
Q ( l/min/m ) 0.00 0.01 0.00 0.00 0.00 UNIDAD LUGEON SELECCIONADA : 0.1 UL
Dp ( bars )
PEF ( bars ) 0.57 0.81 1.04 0.81 0.57 K (PERMEABILIDAD) : 6.5E-09 m/s
K (m/sec) 3.4E-09 7.8E-09 5.1E-09 6.0E-09 1.0E-08
UL 0.03 0.06 0.04 0.05 0.08
1 2 3 4 5
PEF = PM - Dp + Dh / 10.197 UL = Q (L/min/m) x 10 / P EF (bars)

REPRESENTACION GRAFICA
OBSERVACIONES: Baja Permeabiliad
Q (Lpm/m)

1.0

0.9 Packer simple - 30 bar


0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0
0.5 0.6 0.7 0.8 0.9 1.0 1.1
PEF (bars)
Golder Cosapi Geotecnia
ENSAYO DE PERMEABILIDAD DE AGUA A
Golder Associates PRESION TIPO LUGEON
Perú S.A.
SONDAJE Nº PIE-CHK-03-Q161 ENSAYO Nº COORD. NORTE:

PROYECTO : Polishing Pond Dam Raise PROF. DE ENSAYO DE : 6.00 A 11.00 m. COORD. ESTE:
UBICACIÓN: Polishing Pond FECHA : 6/29/2017 Hr.INIC. 15:28 FIN : 16:18 INCLINACIÓN: 90
CÓDIGO: COTA (m.s.n.m.):
LITOLOG. DEL TRAMO :

CAUDALIMETRO
Long. Min.
hm = ALTURA DEL MANOMETRO 1.50 m
MANOMETRO 1.00 m a = ALTURA SOBRE NIVEL DEL TERRENO 0.00 m
Cilindro de
Expansión ha = PROFUNDIDAD NIVEL FREATICO 2.00 m
Dh = SOBRECARGA HIDRAULICA 3.50 m
Bomba
d = PROFUNDIDAD DEL OBTURADOR 6.00 m
hm L = PROFUNDIDAD DE PERFORACION 11.00 m
Dh a = INCLINACION C/HORIZONTAL 90 °
a

Dh' = Dh CORREGIDA = Sen a x Dh 3.50 m


ha
l = LONGITUD TRAMO DE ENSAYO 5.00 m
Ø = DIAMETRO DEL BULBO DEL ENSAYO 9.60 cm
d Dh PM = PRESION MANOMETRICA
L PEF = PRESION EFECTIVA EN EL PUNTO MEDIO DEL TRAMO DEL ENSAYO
ha Dp = PERDIDAS DE CARGA
q = VOLUMEN DE AGUA EN LITROS POR MINUTO DURANTE EL ENSAYO
qt = VOLUMEN TOTAL DE AGUA EN LITROS PARA CADA ESTADIO
l G = CAUDAL EN LITROS POR MINUTO PARA CADA ESTADIO
l/2 Q = CAUDAL EN LITROS POR MINUTO POR Mt. DE TRAMO DE ENSAYO
UL = UNIDAD LUGEON ( Q x 10 / P EF )
Ø

Bars Bars Bars Bars Bars


PM = 0.60 PM = 1.13 PM = 1.70 PM = 1.13 PM = 0.60 GRAFICO DE PATRON DE RESULTADOS
TIEMPO PARA LA SELECCIÓN DE UNIDADES
EN LECTURA LECTURA LECTURA LECTURA LECTURA LUGEON
MINUTO CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l)

0 26.99 31.80 34.13 34.24 34.25 U.L.


0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
1 26.99 0.00 31.80 0.00 34.20 0.07 34.24 0.00 34.25 0.00
2 26.99 0.00 31.80 0.00 34.23 0.03 34.24 0.00 34.25 0.00
ESTADIO

3 26.99 0.00 31.80 0.00 34.24 0.01 34.25 0.01 34.25 0.00
4 26.99 0.00 31.80 0.00 34.24 0.00 34.25 0.00 34.25 0.00 2

5 26.99 0.00 31.80 0.00 34.24 0.00 34.25 0.00 34.25 0.00
3
6
7
4
8
9
5
10
qt(l)
G ( l/min ) 0.00 0.00 0.02 0.00 0.00
Q ( l/min/m ) 0.00 0.00 0.00 0.00 0.00 UNIDAD LUGEON SELECCIONADA : 0.0 UL
Dp ( bars )
PEF ( bars ) 0.94 1.48 2.04 1.48 0.94 K (PERMEABILIDAD) : 7.3E-10 m/s
K (m/sec) 0.0E+00 0.0E+00 2.6E-09 3.3E-10 0.0E+00
UL 0.00 0.00 0.02 0.00 0.00
1 2 3 4 5
PEF = PM - Dp + Dh / 10.197 UL = Q (L/min/m) x 10 / P EF (bars)

REPRESENTACION GRAFICA
OBSERVACIONES: Baja Permeabilidad
Q (Lpm/m)

1.0

0.9 Packer simple - 30 bar


0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0
0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2
PEF (bars)
Golder Cosapi Geotecnia
ENSAYO DE PERMEABILIDAD DE AGUA A
Golder Associates PRESION TIPO LUGEON
Perú S.A.
SONDAJE Nº PIE-CHK-03-Q161 ENSAYO Nº COORD. NORTE:

PROYECTO : Polishing Pond Dam Raise PROF. DE ENSAYO DE : 11.00 A 16.00 m. COORD. ESTE:
UBICACIÓN: Polishing Pond FECHA : 6/29/2017 Hr.INIC. 17:15 FIN : 17:54 INCLINACIÓN: 90
CÓDIGO: COTA (m.s.n.m.):
LITOLOG. DEL TRAMO :

CAUDALIMETRO
Long. Min.
hm = ALTURA DEL MANOMETRO 1.50 m
MANOMETRO 1.00 m a = ALTURA SOBRE NIVEL DEL TERRENO 0.00 m
Cilindro de
Expansión ha = PROFUNDIDAD NIVEL FREATICO 2.00 m
Dh = SOBRECARGA HIDRAULICA 3.50 m
Bomba
d = PROFUNDIDAD DEL OBTURADOR 11.00 m
hm L = PROFUNDIDAD DE PERFORACION 16.00 m
Dh a = INCLINACION C/HORIZONTAL 90 °
a

Dh' = Dh CORREGIDA = Sen a x Dh 3.50 m


ha
l = LONGITUD TRAMO DE ENSAYO 5.00 m
Ø = DIAMETRO DEL BULBO DEL ENSAYO 9.60 cm
d Dh PM = PRESION MANOMETRICA
L PEF = PRESION EFECTIVA EN EL PUNTO MEDIO DEL TRAMO DEL ENSAYO
ha Dp = PERDIDAS DE CARGA
q = VOLUMEN DE AGUA EN LITROS POR MINUTO DURANTE EL ENSAYO
qt = VOLUMEN TOTAL DE AGUA EN LITROS PARA CADA ESTADIO
l G = CAUDAL EN LITROS POR MINUTO PARA CADA ESTADIO
l/2 Q = CAUDAL EN LITROS POR MINUTO POR Mt. DE TRAMO DE ENSAYO
UL = UNIDAD LUGEON ( Q x 10 / P EF )
Ø

Bars Bars Bars Bars Bars


PM = 0.90 PM = 1.80 PM = 2.70 PM = 1.80 PM = 0.90 GRAFICO DE PATRON DE RESULTADOS
TIEMPO PARA LA SELECCIÓN DE UNIDADES
EN LECTURA LECTURA LECTURA LECTURA LECTURA LUGEON
MINUTO CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l) CAUDAL. q (l)

0 21.29 24.86 26.12 26.64 26.64 U.L.


0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
1 21.29 0.00 24.86 0.00 26.12 0.00 26.64 0.00 26.64 0.00
2 21.29 0.00 24.86 0.00 26.12 0.00 26.64 0.00 26.64 0.00
ESTADIO

3 21.29 0.00 24.86 0.00 26.12 0.00 26.64 0.00 26.64 0.00
4 21.29 0.00 24.86 0.00 26.12 0.00 26.64 0.00 26.64 0.00 2

5 21.29 0.00 24.86 0.00 26.12 0.00 26.64 0.00 26.64 0.00
3
6
7
4
8
9
5
10
qt(l)
G ( l/min ) 0.00 0.00 0.00 0.00 0.00
Q ( l/min/m ) 0.00 0.00 0.00 0.00 0.00 UNIDAD LUGEON SELECCIONADA : 0.0 UL
Dp ( bars )
PEF ( bars ) 1.24 2.14 3.04 2.14 1.24 K (PERMEABILIDAD) : 0.0E+00 m/s
K (m/sec) 0.0E+00 0.0E+00 0.0E+00 0.0E+00 0.0E+00
UL 0.00 0.00 0.00 0.00 0.00
1 2 3 4 5
PEF = PM - Dp + Dh / 10.197 UL = Q (L/min/m) x 10 / P EF (bars)

REPRESENTACION GRAFICA
OBSERVACIONES: Tramo impermeable
Q (Lpm/m)

1.0

0.9 Packer simple - 30 bar


0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0
1.0 1.5 2.0 2.5 3.0 3.5
PEF (bars)
Golder Cosapi Geotecnia