TABLA DE DATOS EXPERIMENTALES

BOMBA 1
CORRIDA PS1 PD1 Tiempo Masa
Kgf/cm2 Kgf/cm2 s Kg
1 0.4078 1.5 10 19.2
2 0.4078 1.5 20 34
3 0.4078 1.5 30 46.4
4 0.4078 1.5 40 62
5 0.4078 1.5 50 73
6 0.4078 1.5 60 87
7 0.4078 1.5 70 102
8 0.4078 1.5 80 116
9 0.4078 1.5 90 130
10 0.4078 1.5 100 145
11 0.4078 1.5 110 159
12 0.4078 1.5 120 175
13 0.4078 1.5 130 191

Bombas en Serie
CORRIDA PS1 PD2 Tiempo Masa
Kgf/cm2 Kgf/cm2 s Kg
1 0.5437 2.2 10 23.2
2 0.5437 2.2 20 39.4
3 0.5437 2.2 30 55
4 0.5437 2.2 40 71.6
5 0.5437 2.2 50 86.8
6 0.5437 2.2 60 104.6
7 0.5437 2.2 70 122
8 0.5437 2.2 80 139.4
9 0.5437 2.2 90 157
10 0.5437 2.2 100 176
11 0.5437 2.2 110 196
Bombas en Paralelo
CORRIDA PS1 PD1 PS2 PD2 Tiempo Masa
Kgf/cm2 Kgf/cm2 Kgf/cm2 Kgf/cm2 s Kg
1 0.2718 1.7 0.3534 1.7 5 30
2 0.2718 1.7 0.3534 1.7 10 40
3 0.2718 1.7 0.3534 1.7 15 48
4 0.2718 1.7 0.3534 1.7 20 58
5 0.2718 1.7 0.3534 1.7 25 68
6 0.2718 1.7 0.3534 1.7 30 78
7 0.2718 1.7 0.3534 1.7 35 87.6
8 0.2718 1.7 0.3534 1.7 40 98.2
9 0.2718 1.7 0.3534 1.7 45 109
10 0.2718 1.7 0.3534 1.7 50 120
11 0.2718 1.7 0.3534 1.7 55 130.4
12 0.2718 1.7 0.3534 1.7 60 142
13 0.2718 1.7 0.3534 1.7 65 153.6
14 0.2718 1.7 0.3534 1.7 70 166
15 0.2718 1.7 0.3534 1.7 75 177.6
16 0.2718 1.7 0.3534 1.7 80 188
CÁLCULOS
Nota: Los cálculos de la bomba centrifuga 1, bombas en serie y en paralelo solo se realizaron en la
primera corrida los demás resultados se encuentran en la tabla de resultados

 Bomba Centrifuga 1

o Gasto Masa

m
Gm=
θ

m 19.2 kg
Gm1= = =1.92
θ 10 s

o Capacidad de la Bomba

Kg
3
∗1 m3
Usamos la densidad del agua a 20°C m Kg
ρ=998.204 =0.998204
1000 L L

Gm
Q=
ρ

Gm 1.92 L
Q 1= = =1.9235
ρ 0.998204 s

o Presión Suministrada por la Bomba

∆ P=( Pd −Ps )

Kgf
∆ P1= ( Pd −P s )= (1.5 )−(−0.4078 ) =1.9078
cm2

o Carga Suministrada por la Bomba

∆P
H=
w

∆ P 1.9078
H 1= = =1907.8 cm=19.078 m
w 0.001

o Potencia hidráulica desarrollada por la bomba


Gm∗H∗g
P=
gc

8∗9.81 Kgf ∗m
P1=1.92∗19.07 =36.6298
9.81 s

o Potencia de la Bomba en caballos de fuerza (HP)

Kgf ∗m
1 HP=76.039
s

P
P HP=
76.039

P 36.6298
P HP = = =0.4817 HP
1
76.039 76.039

 Bombas Centrifugas en Serie

o Gasto Masa

m
Gm=
θ

m 23.2 kg
Gm1= = =2.32
θ 10 s

o Capacidad de la Bomba

Kg
3
∗1 m3
Usamos la densidad del agua a 20°C m Kg
ρ=998.204 =0.998204
1000 L L

Gm
Q=
ρ

Gm 2.32 L
Q 1= = =2.3242
ρ 0.998204 s

o Presión Suministrada por la Bomba

∆ P=¿

Kgf
∆ P1= ( Pd −P s )= (2.2 )−(−0.5437 ) =2.7437
cm 2
o Carga Suministrada por la Bomba

∆P
H=
w

∆ P 2.7437
H 1= = =2743.7 cm=27.437 m
w 0.001

o Potencia hidráulica desarrollada por la bomba

Gm∗H∗g
P=
gc

7∗9.81 Kgf ∗m
P1=2.32∗27 .43 =63.6538
9.81 s

o Potencia de la Bomba en caballos de fuerza (HP)

Kgf ∗m
1 HP=76.039
s

P
P HP=
76.039

P 63.6538
P HP = = =0.8371 HP
1
76.039 76.039

 Bombas Centrifugas en Paralelo

o Gasto Masa

m
Gm=
θ

m 30 kg
Gm1= = =6
θ 5 s

o Capacidad de la Bomba

Kg
3
∗1 m3
Usamos la densidad del agua a 20°C m Kg
ρ=998.204 =0.998204
1000 L L
Gm
Q=
ρ

Gm 6 L
Q 1= = =6.0108
ρ 0.998204 s

o Presión Suministrada por la Bomba

∆ P=( Pd −(−Ps ))

P d 1 + Pd 2
Pd =
2

P s 1+ P s 2
Ps =
2

1.7 +1.7
Pd = =1.7
2

0.2718+ 0.3534
Ps = 0.3126
2

Kgf
∆ P1= ( Pd −P s )= (1.7 )−(−0.3126 )=2.0126
cm 2

o Carga Suministrada por la Bomba

∆P
H=
w

∆ P 2.0126
H 1= = =2012.6 cm=20.126 m
w 0.001

o Potencia hidráulica desarrollada por la bomba

Gm∗H∗g
P=
gc

6∗9.81 Kgf ∗m
P1=6∗20.12 =120.7560
9.81 s

o Potencia de la Bomba en caballos de fuerza (HP)

Kgf ∗m
1 HP=76.039
s
P
P HP=
76.039

P 120.75 6
P HP = = =1.5881 HP
1
76.039 76.039
TABLAS DE RESULTADOS

Tabla de Resultados de la Bomba Centrifuga 1


Corrida Gasto Capacidad Presión Carga Potencia Potencia
Masa (Q) Suministrad Suministrad Desarrollad Desarrollada
(Gm) L/s a a a (PHP)
Kg/s ( ∆ P) (H) (P) HP
Kg/cm2 m Kg*m/S
1 1.92 1.9235 1.9078 19.0780 36.6298 0.4817
2 1.7 1.7031 1.9078 19.0780 32.4326 0.4265
3 1.5467 1.5494 1.9078 19.0780 29.5073 0.3881
4 1.55 1.5528 1.9078 19.0780 29.5709 0.3889
5 1.46 1.4626 1.9078 19.0780 27.8539 0.3663
6 1.45 1.4526 1.9078 19.0780 27.6631 0.3638
7 1.4571 1.4598 1.9078 19.0780 27.7994 0.3656
8 1.45 1.4526 1.9078 19.0780 27.6631 0.3638
9 1.4444 1.4470 1.9078 19.0780 27.5571 0.3624
10 1.45 1.4526 1.9078 19.0780 27.6631 0.3638
11 1.4455 1.4481 1.9078 19.0780 27.5764 0.3627
12 1.4583 1.4610 1.9078 19.0780 27.8221 0.3659
13 1.4692 1.4719 1.9078 19.0780 28.03 0.3686

Tabla de Resultados de las Bombas en Serie


Corrida Gasto Capacidad Presión Carga Potencia Potencia
Masa (Q) Suministrad Suministrad Desarrollad Desarrollada
(Gm) L/s a a a (PHP)
Kg/s ( ∆ P) (H) (P) HP
Kg/cm2 m Kg*m/S
1 2.32 2.3242 2.7437 27.4370 63.6538 0.8371
2 1.97 1.9735 2.7437 27.4370 54.0509 0.7108
3 1.8333 1.8366 2.7437 27.4370 50.3012 0.6615
4 1.79 1.7932 2.7437 27.4370 49.1122 0.6459
5 1.7360 1.7391 2.7437 27.4370 47.6306 0.6264
6 1.7433 1.7465 2.7437 27.4370 47.8318 0.6290
7 1.7429 1.7460 2.7437 27.4370 47.8188 0.6289
8 1.7425 1.7456 2.7437 27.4370 47.8090 0.6287
9 1.7444 1.7476 2.7437 27.4370 47.8623 0.6294
10 1.76 1.7632 2.7437 27.4370 48.2891 0.6351
11 1.7818 1.7850 2.7437 27.4370 48.8877 0.6429
Tabla de Resultados de las Bombas en Paralelo
Corrida Gasto Capacidad Presión Carga Potencia Potencia
Masa (Q) Suministrad Suministrad Desarrollad Desarrollada
(Gm) L/s a a a (PHP)
Kg/s ( ∆ P) (H) (P) HP
Kg/cm2 M Kg*m/S
1 6 6.0108 2.0126 20.1260 120.7560 1.5881
2 4 4.0072 2.0126 20.1260 80.5040 1.0587
3 3.2 3.2058 2.0126 20.1260 64.4032 0.8470
4 2.9 2.9052 2.0126 20.1260 58.3654 0.7676
5 2.72 2.7249 2.0126 20.1260 54.7427 0.7199
6 2.6 2.6047 2.0126 20.1260 52.3276 0.6882
7 2.5029 2.5074 2.0126 20.1260 50.3725 0.6625
8 2.4550 2.4594 2.0126 20.1260 49.4093 0.6498
9 2.4222 2.4266 2.0126 20.1260 48.7496 0.6411
10 2.4 2.4043 2.0126 20.1260 48.3024 0.6352
11 2.3709 2.3752 2.0126 20.1260 47.7169 0.6275
12 2.3667 2.3709 2.0126 20.1260 47.6315 0.6264
13 2.3631 2.3673 2.0126 20.1260 47.5593 0.6255
14 2.3714 2.3757 2.0126 20.1260 47.7274 0.6277
15 2.3680 2.3723 2.0126 20.1260 47.6584 0.6268
16 2.35 2.3542 2.0126 20.1260 47.2961 0.6220
GRAFICAS