Está en la página 1de 1

TS_TT

#AA10 #AA9
24.000BTU 24.000BTU

TS_IL_2 (2x4mm2)-#UC1-AA1
(2x4mm2)-#UC2-AA2
2mm2-PAT
PLATAFORMA PARA
Ø2x3/4"
CONDENSADORES
#AA8 #AA7 #AA5 (2x4mm2)-#UC1-AA1
(2x4mm2)-#UC2-AA2 (2x4mm2)-#UC10-AA10

24.000BTU 24.000BTU 12.000BTU TS_AA #AA2


(2x4mm2)-#UC3-AA3
(2x4mm2)-#UC4-AA4
(2x4mm2)-#UC11-AA11
(2x4mm2)-#UC12-AA12
#UC1-AA1
30.000BTU
(2x4mm2)-#UC5-AA5
(2x4mm2)-#UC6-AA6
(2x4mm2)-#UC13-AA13
(2x4mm2)-#UC14-AA14 #UC2-AA2
12.000BTU

(2x4mm2)-#UC7-AA7 (2x4mm2)-#UC15-AA15
(2x4mm2)-#UC16-AA16 (2x4mm2)-#UC3-AA3
TP_ADM (2x4mm2)-#UC8-AA8
(2x4mm2)-#UC4-AA4
#AA3

(2x4mm2)-#UC9-AA9 (2x4mm2)-#UC17-AA17 2mm2-PAT


10mm2-PAT Ø2x3/4"
Bandeja de 150mm

#UC3-AA3
#UC4-AA4 (2x4mm2)-#UC1-AA3
(2x4mm2)-#UC5-AA5
(2x4mm2)-#UC6-AA6
2mm2-PAT
Ø2x3/4"
24.000BTU

#UC5-AA5
#AA1

#UC6-AA6
(2x4mm2)-#UC7-AA7
(2x4mm2)-#UC8-AA8
2mm2-PAT
Ø2x3/4"
12.000BTU

12.000BTU

#UC7-AA7
#AA6

#UC8-AA8
#AA4

(2x4mm2)-#UC9-AA9
(2x4mm2)-#UC10-AA10
2mm2-PAT
Ø2x3/4"

#UC3-AA9
#UC4-AA10 TCIL_1 TS_P
RBT_10 RBT_08
RBT_09

Módulos de Tableros BT
CAÑERÍA SUBTERRÁNEA

TT_G TBC
3x(1x70mm2) - TG_ADM
3x(1x70mm2) - TG_ADM 3x(1x70mm2) - TG_ADM
RBT_12 3x(1x95mm2) - TG_ADM 3x(1x70mm2) - TG_ADM
3x(1x95mm2) - TG_ADM 3x(1x95mm2) - TG_ADM
(2x4mm2)-#1-UPS RBT_11 50mm2 - desnudo - PAT 50mm2 - desnudo - PAT 3x(1x95mm2) - TG_ADM
(4x6mm2) - #TSP Ø2x3" - 14mts Ø2x3" - 24mts 50mm2 - desnudo - PAT
50mm2 - desnudo - PAT Ø2x3" - 20mts
Ø2x3" - 12mts Transformador Pedestal

TG
PLANTA BAJA ELÉCTRICA 150kva
1 Escala 1:100 Generador a Diesel
150kva

(2x4mm2)-#UC11-AA11
VIENE DE PUESTO DE ENTREGA
(2x4mm2)-#UC12-AA12
2mm2-PAT
Ø2x3/4"

#UC11-AA11
#UC12-AA12
(2x4mm2)-#UC13-AA13
(2x4mm2)-#UC14-AA14
2mm2-PAT
Ø2x3/4"
TS_ADM
#AA15 #AA14 #AA13 #AA12 #AA11 #UC13-AA13
18.000BTU 18.000BTU 24.000BTU 24.000BTU 24.000BTU #UC14-AA14
(2x4mm2)-#UC15-AA15
(2x4mm2)-#UC16-AA16
2mm2-PAT
Ø2x3/4"
+6mts

TT_UPS #UC15-AA15
#AA17 #UC16-AA16
24.000BTU #AA16 TS_UPS (2x4mm2)-#UC17-AA17
2mm2-PAT
Ø2x3/4"

#UC17-AA17 TP_ADM

PLATAFORMA PARA
CONDENSADORES TS_ADM

TCIL_1...2
PLANTA ALTA ELÉCTRICA NOTAS:
2 Escala 1:100
TS_UPS

TS_TT

2. TODOS LOS DUCTOS EN EL EXTERIOR PARA CONEXIONADO DE LOS ACONDICIONADORES DE AIRE

3. TODOS LOS ACONDICIONADORES DE AIRE SERAN ALIMENTADOS DESE EL TABLERO SECCIONAL TS_AA.
TS_AA

TT_UPS
A& B
Ingeniería S.A.
cervepar
CERVECERIA PARAGUAYA

HORARIO. INSTALACIÓN ELÉCTRICA DE AIRE ACONDICIONADO


OFICINA PLANTA ALTA - BAJA

DEL TIPO NYY PROTEGIDO DE 1000V. RBT_12


IE_AA_PLANTA_R00
UNIDAD CONDENSADORA EXTERNA PARA AIRE ACONDICIONADO.
A LOS COLORES:
FASE-ROJO
UNIDAD EVAPORADORA PARA AIRE ACONDICIONADO CASETTE.
NEUTRO-CELESTE
TIERRA-VERDE/AMARILLO
UNIDAD EVAPORADORA PARA AIRE ACONDICIONADO SPLIT.

También podría gustarte