Documentos de Académico
Documentos de Profesional
Documentos de Cultura
CIRCUITO 1: ILUMINACIÓN
1. CÁLCULO DE CARGAS
#LUM X PLUM
ILUM =
VLUM X CosØ
6 X 28.2
ILUM = = 1.48 A
127 X 0.9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ILUM =
FactCorrTemp X FactCorrAgrup
1.48
ILUM = = 1.95 A
0.95 X 0.80
4. AMPACIDAD
14 AWG = 25 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 1.48 A 1x10A
1
CIRCUITO 2: CONTACTOS
1. CÁLCULO DE CARGAS
#CONT X PCONT
ICONT =
VCONT X CosØ
9 X 180
ICONT = = 14.17 A
127 X 0.90
Factor de Simultaneidad
8 = 0.89
FS=
9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ICONT =
FactCorrTemp X FactCorrAgrup
12.60
ICONT = = 16.58 A
0.95 X 0.80
2
4. AMPACIDAD
12 AWG = 30 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 12.60 A 1x20A
3
CÁLCULO DE CALIBRES DE CONDUCTORES SALÓN 2°
CIRCUITO 1: ILUMINACIÓN
1. CÁLCULO DE CARGAS
#LUM X PLUM
ILUM =
VLUM X CosØ
6 X 28.2
ILUM = = 1.48 A
127 X 0.9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ILUM =
FactCorrTemp X FactCorrAgrup
1.48
ILUM = = 1.95 A
0.95 X 0.80
4. AMPACIDAD
14 AWG = 25 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 1.48 A 1x10A
4
CIRCUITO 2: CONTACTOS
1. CÁLCULO DE CARGAS
#CONT X PCONT
ICONT =
VCONT X CosØ
9 X 180
ICONT = = 14.17 A
127 X 0.90
Factor de Simultaneidad
8 = 0.89
FS=
9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ICONT =
FactCorrTemp X FactCorrAgrup
12.60
ICONT = = 16.58 A
0.95 X 0.80
5
4. AMPACIDAD
12 AWG = 30 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 12.60 A 1x20A
6
CÁLCULO DE CALIBRES DE CONDUCTORES SALÓN 3°
CIRCUITO 1: ILUMINACIÓN
1. CÁLCULO DE CARGAS
#LUM X PLUM
ILUM =
VLUM X CosØ
6 X 28.2
ILUM = = 1.48 A
127 X 0.9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ILUM =
FactCorrTemp X FactCorrAgrup
1.48
ILUM = = 1.95 A
0.95 X 0.80
4. AMPACIDAD
14 AWG = 25 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 1.48 A 1x10A
7
CIRCUITO 2: CONTACTOS
1. CÁLCULO DE CARGAS
#CONT X PCONT
ICONT =
VCONT X CosØ
9 X 180
ICONT = = 14.17 A
127 X 0.90
Factor de Simultaneidad
8 = 0.89
FS=
9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ICONT =
FactCorrTemp X FactCorrAgrup
12.60
ICONT = = 16.58 A
0.95 X 0.80
8
4. AMPACIDAD
12 AWG = 30 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 12.60 A 1x20A
9
CÁLCULO DE CALIBRES DE CONDUCTORES SALÓN 4°
CIRCUITO 1: ILUMINACIÓN
1. CÁLCULO DE CARGAS
#LUM X PLUM
ILUM =
VLUM X CosØ
6 X 28.2
ILUM = = 1.48 A
127 X 0.9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ILUM =
FactCorrTemp X FactCorrAgrup
1.48
ILUM = = 1.95 A
0.95 X 0.80
4. AMPACIDAD
14 AWG = 25 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 1.48 A 1x10A
10
CIRCUITO 2: CONTACTOS
1. CÁLCULO DE CARGAS
#CONT X PCONT
ICONT =
VCONT X CosØ
9 X 180
ICONT = = 14.17 A
127 X 0.90
Factor de Simultaneidad
8 = 0.89
FS=
9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ICONT =
FactCorrTemp X FactCorrAgrup
12.60
ICONT = = 16.58 A
0.95 X 0.80
11
4. AMPACIDAD
12 AWG = 30 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 12.60 A 1x20A
12
CÁLCULO DE CALIBRES DE CONDUCTORES SALÓN 5°
CIRCUITO 1: ILUMINACIÓN
1. CÁLCULO DE CARGAS
#LUM X PLUM
ILUM =
VLUM X CosØ
6 X 28.2
ILUM = = 1.48 A
127 X 0.9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ILUM =
FactCorrTemp X FactCorrAgrup
1.48
ILUM = = 1.95 A
0.95 X 0.80
4. AMPACIDAD
14 AWG = 25 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 1.48 A 1x10A
13
CIRCUITO 2: CONTACTOS
1. CÁLCULO DE CARGAS
#CONT X PCONT
ICONT =
VCONT X CosØ
9 X 180
ICONT = = 14.17 A
127 X 0.90
Factor de Simultaneidad
8 = 0.89
FS=
9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ICONT =
FactCorrTemp X FactCorrAgrup
12.60
ICONT = = 16.58 A
0.95 X 0.80
14
4. AMPACIDAD
12 AWG = 30 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 12.60 A 1x20A
15
CÁLCULO DE CALIBRES DE CONDUCTORES SALÓN 6°
CIRCUITO 1: ILUMINACIÓN
1. CÁLCULO DE CARGAS
#LUM X PLUM
ILUM =
VLUM X CosØ
8 X 28.2
ILUM = = 1.97 A
127 X 0.9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ILUM =
FactCorrTemp X FactCorrAgrup
1.97
ILUM = = 2.6 A
0.95 X 0.80
4. AMPACIDAD
14 AWG = 25 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 1.97 A 1x10A
16
CIRCUITO 2: CONTACTOS
1. CÁLCULO DE CARGAS
#CONT X PCONT
ICONT =
VCONT X CosØ
9 X 180
ICONT = = 14.17 A
127 X 0.90
Factor de Simultaneidad
8 = 0.89
FS=
9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ICONT =
FactCorrTemp X FactCorrAgrup
12.60
ICONT = = 16.58 A
0.95 X 0.80
17
4. AMPACIDAD
12 AWG = 30 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 12.60 A 1x20A
18
CÁLCULO DE CALIBRES DE CONDUCTORES DIRECCIÓN
CIRCUITO 1: ILUMINACIÓN
1. CÁLCULO DE CARGAS
#LUM X PLUM
ILUM =
VLUM X CosØ
6 X 28.1
ILUM = = 1.48 A
127 X 0.9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ILUM =
FactCorrTemp X FactCorrAgrup
1.48
ILUM = = 1.94 A
0.95 X 0.80
4. AMPACIDAD
14 AWG = 25 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 1.48 A 1x10A
19
CIRCUITO 2: CONTACTOS
1. CÁLCULO DE CARGAS
#CONT X PCONT
ICONT =
VCONT X CosØ
8 X 180
ICONT = = 12.60 A
127 X 0.90
Factor de Simultaneidad
6 =
FS= 0.75
8
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ICONT =
FactCorrTemp X FactCorrAgrup
10.63
ICONT = = 13.99 A
0.95 X 0.80
20
4. AMPACIDAD
12 AWG = 30 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 10.63 A 1x20A
21
CÁLCULO DE CALIBRES DE CONDUCTORES BAÑOS
CIRCUITO 1: ILUMINACIÓN
1. CÁLCULO DE CARGAS
#LUM X PLUM
ILUM =
VLUM X CosØ
6 X 28.1
ILUM = = 1.48 A
127 X 0.9
2. CALIBRE DE TABLAS
3. CORRIENTE CORREGIDA
IT
ILUM =
FactCorrTemp X FactCorrAgrup
1.48
ILUM = = 1.94 A
0.95 X 0.80
4. AMPACIDAD
14 AWG = 25 A
5. TERMOMAGNÉTICO
ITERMOMAGNÉTICO = INOM
ITERMOMAGNÉTICO = 1.48 A 1x10A
22
CÁLCULO DEL INTERRUPTOR GENERAL
INT. GRAL = INOMS1 + INOMS2 + INOMS3 + INOMS4 + INOMS5+ INOMS6++ INOMD++ INOMB
23