Está en la página 1de 1

CENTRO DE DISTRIBUCIÓN 01830 - BARRIO LA GAVIOTA - IBAGUÉ

CR
A
1
CONVENCIONES
E

TPP
CLL DIAGRAMA UNIFILAR / / / / // //

CRA
DE LOS TRANSFORMADORES
Ø Ø Ø Ø Ø Ø ØØ ØØ ØØ ØØ

X X X X xx xx

E
6u + + + + ++ ++ ++
E

TR-1 DE 150 kVA - REUBICADO

3
RED EXISTENTE 13.2 kV 3X1/0 ACSR

X
X

2 AC
CRA X
Bucle y

34m R
X
Grapa para

X
conectar en

S
X
caliente

X
X
X
X
DPS Cortacircuitos

X
15 kV - 100Amp

X
12 kV - 10 kA

X
Cobre desnudo FUSIBLES 7.8 AMP. TIPO DUAL

2 X
Calibre No2 AWG

X
E
CRA 1

X
14 u
L 2/0

X
L

X
TRANSFORMADOR TRIFÁSICO

C
E LINEA A TIERRA
19m R

X
R<=10 Ohm REUBICADO

X
S
2 AC

X
VARILLA Y CABLE ACERADOS 150 kVA

X
13200/208-120 Volt

X
E 5/8"x2.4 m
21m R 2u

X
X
S
2 AC

X
X
CLL 3 BORNERA BT TRANSFORMADOR

2 AC
CD 01862 3 u

X
E

31m R
15 u

X
X
150 kVA
39m R BAJANTE ALIMENTADOR No.1 BAJANTE ALIMENTADOR No.2 BAJANTE ALIMENTADOR No.3 BAJANTE ALIMENTADOR No.4
E

S
S
X

3x2/0+2/0 AWG THWN CU 3x2/0+2/0 AWG THWN CU 3x2/0+2/0 AWG THWN CU


2 AC
E
X
X
3x2+2 AWG THWN CU
5u

X
6m
X
24m 18m SECCIONADOR SECCIONADOR SECCIONADOR SECCIONADOR

X
39m 13 u

X
2 ACSR E
PORTA FUSIBLE PARA BT PORTA FUSIBLE PARA BT PORTA FUSIBLE PARA BT PORTA FUSIBLE PARA BT
2 ACSR

X
14 u
E
2 ACSR 13 u E NORMA LA336 NORMA LA335 NORMA LA335 NORMA LA335

X
FUSIBLES TIPO NH2 200 A. FUSIBLES TIPO NH0 200 A. FUSIBLES TIPO NH0 160 A. FUSIBLES TIPO NH0 125 A.
11 u

X
X
3x2/0+1/0 AWG AAAC 3x2/0+1/0 AWG AAAC 3x2/0+1/0 AWG AAAC 3x2+1/0 AWG AAAC #u #u #u

X
E

X
E RED BAJA TENSION TRENZADA RED BAJA TENSION TRENZADA RED BAJA TENSION TRENZADA RED BAJA TENSION TRENZADA

X
1/0 A
3x2+4 AWG THWN CU 3x2+4 AWG THWN CU 3x2+4 AWG THWN CU

X
3x2+4 AWG THWN CU

X
30m R
X
CAJA TRIFASICA TIPO INTEMPERIE CAJA TRIFASICA TIPO INTEMPERIE CAJA TRIFASICA TIPO INTEMPERIE CAJA TRIFASICA TIPO INTEMPERIE

X
PARA ACOMETIDAS PARA ACOMETIDAS PARA ACOMETIDAS PARA ACOMETIDAS

CS

X
X
X

2 AC
X

31m
X
X
CD 01861

SR
X
CLL 94A

30 kVA

X
E

X
CLL 2 TR-2 DE 112,5 kVA - NUEVO

X
X
X

X
X

7u E
X

X
X
2u

X
Poste RED EXISTENTE 13.2 kV 3X1/0 ACSR
# #

X
#

X
1/0
E

X
Inclinado Bucle y

CLL 2
16m

X
25m R
X

do
4u Grapa para

ACS
do
E
43m
2 Trenza

2/0 T
12 u

Tr 17m
conectar en

za
X
E
2 ACSR caliente

en
X

22m ado
1u 12 u

renz
E
39m

0
DPS

X
2 ACSR Cortacircuitos

2/
32m

X
15m 12 kV - 10 kA 15 kV - 100Amp

X
E
6u
26m 28m 2 ACSR FUSIBLES 5,2 AMP. TIPO DUAL

X
9u Cobre desnudo
E
2 ACSR

X
1/0
E

2 ACSR 10 u Calibre No2 AWG


2 ACSR

X
12 u 0u

X
E

14m R
1u 2/0

X
ACS
TRANSFORMADOR TRIFASICO

X
E LINEA A TIERRA

X
R<=10 Ohm NUEVO

X
112,5 kVA

X
VARILLA Y CABLE ACERADOS
13200/208-120 Volt

X
5/8"x2.4 m
TRANSFORMADOR 1 TRANSFORMADOR 2

X
CD 01830

2/0 Tr
E

112,5 kVA X

E
X
X

2 7 m do
Existente 12 u BORNERA BT TRANSFORMADOR

enza
X
X
X
BAJANTE ALIMENTADOR No.1 BAJANTE ALIMENTADOR No.2

X
3x2/0+2/0 AWG THWN CU 3x2+2 AWG THWN CU

X
X
X
X
SECCIONADOR SECCIONADOR

X
E
PORTA FUSIBLE PARA BT PORTA FUSIBLE PARA BT

X
1/0 A

X
NORMA LA336 NORMA LA335
X
FUSIBLES TIPO NH2 200 A. FUSIBLES TIPO NHO 125 A.
42m R
X
7u E

2u E
3x2/0+1/0 AWG AAAC 3x2+1/0 AWG AAAC
CS

RED BAJA TENSION TRENZADA


X

RED BAJA TENSION TRENZADA


X

9u 3x2+4 AWG THWN CU 3x2+4 AWG THWN CU


X

T
X

42m
NOTAS GENERALES BAJA TENSIÓN
E
CAJA TRIFASICA TIPO INTEMPERIE CAJA TRIFASICA TIPO INTEMPERIE
X

15 u
X

2 ACSR PARA ACOMETIDAS PARA ACOMETIDAS


2u
X

T
X

E
Poste E
45m
X

10 u 1u
X

Inclinado 2 ACSR
28m
X

T E
X

E
E
36m 3u 2u 6m 4 CU
X

T
2 ACSR 10 u 40m
X

E
23m 19m 4 u
X

2 ACSR
X

E
2 ACSR 2 ACSR E
X

AV. AMBALÁ
X
X

Percha en
X

Poste
X

Fachada
X

Inclinado
X
X
X
X
X
X
X
X
X
X

E
X
X

DETALLE DE ESTRUCTURAS
X
X
X
X

URB. ARCAMBUCO
X
X

NORMA TAH 712 NORMA TA 701


REDES ELECTRICAS EXISTENTES TRANSFORMADOR No 1 TRANSFORMADOR No 2
NOTAS GENERALES MEDIA TENSIÓN
ESCALA 1:800
E

4
TPP

C L L
CRA

6u
3

7
TZ322
X
X

3x2+
CRA X

34m /0
X
X
X

1
X
X
X
X
X
X
X
X

2 X

3
E
X

Se pasan dos
CRA 1

14 u
L
X

L
X

usuarios al CD
X

5
C
E

19m 1/0
X

01862
X

0+
3 2/ TZ327
X

x
X

E TZ323
X

21m 1/0 2 u
X

0+
X

3 2/
x 4
X

3x2

CLL 3
X

13 u
CD 01862 5 u
E
TZ327
31m 1/0

22m 1/0
X

3
/0+
X

150 kVA 0+
3x2/
E
X
X

5u TZ320
17m +1/0
E
X

0 2
X

19m 3x2/
X

39m 24m
X

E
10 u TZ320
3x2/0+1/0
X

11 u
E
3x2+1/0 13 u E
3x2+1/0
X

1
X

11 u
X

9 8 X
X
X
ICEL 521 TZ327 E
CD 01830- 2 Poste nuevo 6
2xT323
TZ

TZ322 TZ327
X

10 u
E
112,5 kVA 3u 8x510 TZ322
X
Z32 25 1/0

Nuevo
X

14 Poste nuevo
X
2

TZ322 12x1050
X
3x2

X
X

31m
m
+

TPP
/0

CD 01861
3x2/0+1

X
34m
CLL 94A

30 kVA
X

E
X

CLL 2
X
X

X
X

X
X
E
7u
X

1u
X

10
X
X

Aplomar 5
X

TZ322 E
X

16m /0 20
3x2/0 m
CLL 2
X
26m

Poste nuevo
X

1
TPP

10 u
x2/0+
E
+1/0
X

d
2/0 T

2u
Tr 17m

3 23m 8x750
za
X

E
4u
13
X

3x2/0+
12
en
X

1
22m ado

/0 10 u
11
X

TZ327
renz

E
39m
X

TZ327 TZ327
0
X

TZ320
10 3x2/0+1
2/
X

/0 32m
15m 1
X

E
5u
3x2/0+1/0
X

TZ327 9u E
26m 28m
X

Poste nuevo 3x2/0+1 10 u E

3x2/0+1/0 4
X

/0
9 8 3x2/0+1/0
X

8x510 13 u E
3u
3
X

TZ323
13m
X

CRA
3x2//0

TZ327 TZ327 2 6 E
3x2

TZ320
CIMENTACIÓN DE POSTES LOCALIZACIÓN GENERAL RESUMEN DEL PROYECTO
X

TZ327
X

TZ327
0

CD 01830-1
X

3
4xTZ322
X

2/0 Tr

150 kVA E

Reubicado del
X
X

CRA
E
X
27m do

10 u
X

CD 00445
enza

TZ322
X
X
3x2/0

Santa Barbara
22
3x2++1/0

X
20m

2
3

CRA 1
X

Ibagué CLL
X

6u
X

Aplomar
1/0

X
X

Poste nuevo CLL 3


X

E
X

8x510
X
3x

6u 6u
X
15 +1/0

TZ327 Poste nuevo


E
2/0

8x510 TZ327 15 Poste nuevo 7


m

21
X

E
X

TZ327 8x510
X

TZ327
TZ327 23
X

3u
19
X

T TZ320
20
22m
X

E 31m TZ322
3x2/0

TZ327
18
3x2++1/0

11m 12 u
CLL 94A

3x2/0+1/0
28
X

17 CLL 2
X

T
3x2/0 23m TZ327
X

E
E 5u
X

3x2/0+1/0 TZ320 TZ327 1u


1/0

22m 10 u 27
X

25 26 34m CLL 2
X

T
3x2/0+1/0 E
X

E
36m 2u 3x2+1/0
E
X

T
3x2/0+1/0 8u 3u 40m
X

E
23m 19m 4 u
X

3x2+1/0
X

TZ327 3x2+1/0
16 E
3x2+1/0 E
X

CD 01830
AV. AMBALÁ
X

TZ327
X

24
E

112,5 kVA
X

E
X
X

Existente
X
X

Aplomar
X
X
X
X
X
X
X
X

E
X

AV. AMBALÁ
X
X
X
X
X

URB. ARCAMBUCO
X

CALLE 96
URB. ARCAMBUCO
CLL 95B

EXCAVACIÓN PARA POSTES


CR 13A
REDES ELECTRICAS PROYECTADAS
CLL 94D

ESCALA 1:800