Documentos de Académico
Documentos de Profesional
Documentos de Cultura
PRÁCTICA Nº 04
PRACTICA Nº 7
“INTERCAMBIADOR DE CALOR
DE PLACAS EN PARALELO Y CONTRACORRIENTE”
FECHA DE EJECUCIÓN : 18 / 05 / 18
FECHA DE ENTREGA : 25 / 05 / 18
AYACUCHO – PERÚ
2018
INTERCABIADOR DE CALOR DE PLACAS EN PARALELO Y CONTRACORRIENTE
I. OBJETIVOS:
INTERCABIADOR DE CALOR
Agua fría:
Agua caliente
T1= 63.3 °C
T2=41.7 °C
T3=17.2 °C
T4=34.2 °C
Fluido caliente:
A Temperatura 63.3 °C ρ = 982.96 Kg/m3
A Temperatura 41.7 ° C ρ = 992.90 Kg/m3
982.96+992.90
𝜌̂
𝐻2 𝑂 = ( ) 𝐾𝑔/m3
2
3
𝜌̂
𝐻2 𝑂 = 987.93 Kg/m
A Temperatura 63.3° C Cp = 4.1867 KJ/Kg.K
A Temperatura 41.7 ° C Cp = 4.1836 KJ/Kg.K
4.1867+4.1836
̂
𝐶𝑝𝐻2 𝑂 = ( )KJ/Kg. K
2
̂
𝐶𝑝𝐻2 𝑂 = 4.1852 KJ/KgK
Fluido frio:
A Temperatura 17.2 ° C ρ = 997.7694 Kg/m3
A Temperatura 34.2 ° C ρ = 995.2514 Kg/m3
997.7694+995.2514
𝜌̂
𝐻2 𝑂 = ( ) 𝐾𝑔/m3
2
3
𝜌̂
𝐻2 𝑂 = 996.51 Kg/m
4.1864+4.183
̂
𝐶𝑝𝐻2 𝑂 = ( )KJ/Kg. K
2
̂
𝐶𝑝𝐻2 𝑂 = 4.1847 KJ/KgK
𝑚𝐿 1𝐿 1𝑚3
𝒄𝒂𝒖𝒅𝒂𝒍 = 117.0057 𝑠
𝑥 𝑥
1000 𝑚𝐿 1000 𝐿
𝑚3
𝒄𝒂𝒖𝒅𝒂𝒍 = 1.1701𝑥10−4
𝑠
𝑚3 𝐾𝑔
𝑚𝑐𝑎𝑙𝑖𝑒𝑛𝑡𝑒
̇ = 𝑐𝑎𝑢𝑑𝑎𝑙𝑥𝜌 = 1.170𝑥10−4 𝑥987.93 3
𝑠 𝑚
𝐾𝑔
𝑚𝑐𝑎𝑙𝑖𝑒𝑛𝑡𝑒
̇ = 0.1156
𝑠
𝑚𝐿 1𝐿 1𝑚3
𝒄𝒂𝒖𝒅𝒂𝒍 = 116.0963 𝑠
𝑥 1000 𝑚𝐿 𝑥 1000 𝐿
𝑚3
𝒄𝒂𝒖𝒅𝒂𝒍 = 1.1610𝑥10−4
𝑠
−4
𝑚3 𝐾𝑔
𝑚𝑓𝑟í𝑜
̇ = 𝑐𝑎𝑢𝑑𝑎𝑙𝑥𝜌 = 1.1610𝑥10 𝑥996.51 3
𝑠 𝑚
𝐾𝑔
𝑚𝑓𝑟𝑖𝑜
̇ = 0.1157
𝑠
𝑸𝒇 = 𝑚𝑓𝑟𝑖𝑜
̇ ∗ 𝐶𝑝𝑓𝑟𝑖𝑜 ∗ ∆𝑇𝑓
Kg KJ
𝑸𝒇 = 0.1157 s
∗ 4.1847 kg.K ∗ (34.2 − 17.2)K
𝑸𝒇 =8.2309 KJ/s
10.4503+8.2309
𝑸𝒑𝒓𝒐𝒎𝒆𝒅𝒊𝒐 = ( 2
)Kj/s
𝑸𝒑𝒓𝒐𝒎𝒆𝒅𝒊𝒐 = 9.3406 Kj/s
10.4503−8.2309
𝑸𝒑𝒆𝒓𝒅𝒊𝒅𝒐 = ( 2
)Kj/s
T3 T4
𝟒𝟔.𝟏𝑲 −𝟕.𝟓𝑲
𝑻𝑳 = 𝟒𝟔.𝟏𝑲
𝑳𝒏( )
𝟕.𝟓𝑲
𝑻𝑳 = 21.26𝑘
𝑝𝑟𝑜𝑚𝑒𝑑𝑖𝑜
Uof =
A × ∆TL
kJ
9.3406 s
Uof =
0.18 m2 × 21.26 K
kW
Uof = 2.4408
m2 . K
Agua fría:
Agua caliente
T1= 60.2 °C
T2=37.1 °C
T3=17.2 °C
T4=34.3 °C
Fluido caliente:
A Temperatura 60.2 °C ρ = 984.39Kg/m3
A Temperatura 37.1 ° C ρ = 994.81 Kg/m3
984.36+994.81
𝜌̂
𝐻2 𝑂 = ( ) 𝐾𝑔/m3
2
3
𝜌̂
𝐻2 𝑂 = 989.585 Kg/m
4.186+4.183
̂
𝐶𝑝𝐻2 𝑂 = ( )KJ/Kg. K
2
̂
𝐶𝑝𝐻2 𝑂 = 4.1845 KJ/Kg.K
Fluido frio:
A Temperatura 17.2 ° C ρ = 997.77 Kg/m3
A Temperatura 36.3 ° C ρ = 994.93 Kg/m3
997.77+994.93
𝜌̂
𝐻2 𝑂 = ( ) 𝐾𝑔/m3
2
3
𝜌̂
𝐻2 𝑂 = 996.35 Kg/m
4.185+4.183
̂
𝐶𝑝𝐻2 𝑂 = ( )KJ/Kg. K
2
̂
𝐶𝑝𝐻2 𝑂 = 4.184 KJ/Kg.K
Calculo del flujo másico para el frio y el caliente:
𝑚𝐿 1𝐿 1𝑚3
𝒄𝒂𝒖𝒅𝒂𝒍 = 117.0057 𝑠
𝑥 𝑥
1000 𝑚𝐿 1000 𝐿
−4
𝑚3
𝒄𝒂𝒖𝒅𝒂𝒍 = 1.1701𝑥10
𝑠
𝑚3 𝐾𝑔
𝑚𝑐𝑎𝑙𝑖𝑒𝑛𝑡𝑒
̇ = 𝑐𝑎𝑢𝑑𝑎𝑙𝑥𝜌 = 1.170𝑥10−4 𝑥989.585 3
𝑠 𝑚
𝐾𝑔
𝑚𝑐𝑎𝑙𝑖𝑒𝑛𝑡𝑒
̇ = 0.1158
𝑠
𝑚𝐿 1𝐿 1𝑚3
𝒄𝒂𝒖𝒅𝒂𝒍 = 116.2480 𝑥 𝑥
𝑠 1000 𝑚𝐿 1000 𝐿
𝑚3
𝒄𝒂𝒖𝒅𝒂𝒍 = 1.1625𝑥10−4
𝑠
𝑚3 𝐾𝑔
̇ = 𝑐𝑎𝑢𝑑𝑎𝑙𝑥𝜌 = 1.1625𝑥10−4
𝑚𝑓𝑟í𝑜 𝑥996.51 3
𝑠 𝑚
𝐾𝑔
𝑚𝑓𝑟𝑖𝑜
̇ = 0.1158
𝑠
𝑸𝒇 = 𝑚𝑓𝑟𝑖𝑜
̇ ∗ 𝐶𝑝𝑓𝑟𝑖𝑜 ∗ ∆𝑇𝑓
Kg KJ
𝑸𝒇 = 0.1158 s
∗ 4.184 kg.K ∗ (36.3 − 17.2)K
𝑸𝒇 =9.2541 KJ/s
11.1935+9.2541
𝑸𝒑𝒓𝒐𝒎𝒆𝒅𝒊𝒐 = ( )Kj/s
2
𝑸𝒑𝒓𝒐𝒎𝒆𝒅𝒊𝒐 = 10.2238 Kj/s
11.1935−9.2541
𝑸𝒑𝒆𝒓𝒅𝒊𝒅𝒐 = ( ))Kj/s
2
∆𝑻𝟐 − ∆𝑻𝟏
∆𝑻𝑳 =
∆𝑻
𝑳𝒏 (∆𝑻𝟐 )
𝟏
𝟒𝟑𝑲 −𝟏𝟗.𝟗𝑲
𝑻𝑳 = 𝟒𝟑𝑲
T3 𝑳𝒏( )
𝟏𝟗.𝟗𝑲
T4T3
𝑻𝑳 = 29.98𝑘
𝑝𝑟𝑜𝑚𝑒𝑑𝑖𝑜
Uof =
A × ∆TL
kJ
10.2238 s
Uof = 2
0.18 m × 29.98 K
kW
Uof = 1.8946
m2 . K
V. CONCLUSIÓN:
Determinamos la calor perdido y el coeficiente global de transferencia de
calor referido a la superficie externa (Uo) en flujo paralelo y en
contracorriente.
VI. BIBLIOGRAFIA:
1. http://t-soluciona.com/noticias/intercambiadores-calor-que-son-sirven/
2. Guía de intercambiadores de calor (Dorinda Gonzales Mendizábal).
Universidad Simón Bolívar. Sartenejas, marzo del 2002.
3. http://www.cie.unam.mx/~OJS/PUB/HEATEXCHANGER/INTERCAMBIADORES.S
.A
VII. ANEXO: