Está en la página 1de 9

CABALLAJE

DIÁMETRO DIÁMETRO ÁREA EN m2 GASTO EN VELOCIDAD LONGITUD Q2 COEF. FRICC. CTE. DE


INTERIOR NOMINAL (A) m3/seg. EN m/seg. LINEAL MANNING MANNING
m Pulg. (Q) (V) en m. (L) (N) (K)
0.08160 3 0.0052 0.00800 1.530 610.20 0.000064 0.009 531.338
0.10500 4 0.0087 0.00800 0.924 610.20 0.000064 0.009 138.476
0.15450 6 0.0187 0.00800 0.427 610.20 0.000064 0.009 17.651

GOLPE DE ARIETE
145V Ead E te
PRESIÓN DE DIAM. INT. ESPESOR VEL. Ead 1+ Ead
TRABAJO KG/CM2 (D) PARED DE m/seg. E te E te
cm TUBO (e) cm
11.2 8.16 0.365 1.530 221.81 168,667 10,257 16.44 17.44
11.2 10.50 0.465 0.924 133.96 217,035 13,067 16.61 17.61
11.2 15.45 0.690 0.427 61.87 319,352 19,389 16.47 17.47

ANÁLISIS DE COSTOS MATERIALES Y M.O.


CONCEPTO DIÁMETRO: 3" CLASE: PVC-26 DIÁMETRO: 4" CLASE: PVC-26
CANTIDAD U. P/U IMPORTE CANTIDAD U. P/U IMPORTE
EXCAVACIÓN MAT. COMÚN 292.90 M3 25.88 7,580.15 307.54 M3 25.88 7,959.16
EXCAVACIÓN MAT. III 73.22 M3 242.93 17,788.31 76.89 M3 242.93 18,677.72
PLANTILLA APISONADA 25.63 M3 114.22 2,927.28 36.61 M3 114.22 4,181.82
RELLENO COMPACTADO 138.60 M3 102.82 14,250.49 145.42 M3 102.82 14,952.33
RELLENO A VOLTEO 198.11 M3 40.51 8,025.34 196.13 M3 40.51 7,945.25
INSTALACIÓN DE TUBERÍA 610.20 ML 5.20 3,173.04 610.20 ML 7.04 4,295.81
SUMINISTRO DE TUBERÍA 610.20 ML 44.16 26,946.43 610.20 ML 73.09 44,599.52
VAL. CONTRA GOLPE DE ARIETE 0.00 PZA 0.00 PZA 0.00

COSTO TOTAL DE CONDUCCIÓN 80,691.03 102,611.60

DIÁMETRO MAS ECONÓMICO


PRESIÓN DE TRABAJO DIÁMETRO HP Kwh. COSTO POR HR. CARGO ANUAL
TUBERÍA KG/CM2 MM pulg. 1 2 BOMBEO $ 3 DE BOMBEO 4
11.2 76.2 3 3.82 2.850 4.28 14,045.22
11.2 101.6 4 1.00 0.743 1.11 3,660.44
11.2 152.4 6 0.13 0.095 0.14 466.58

(8) 414304806.xlsx 1 de 1
GASTO (LPS) 8.00 ANUALIDAD 0.253
DESNV. TOPOGRA (m) 58.63 I. ANUAL BANCARIO 25.0% NOTA:
LONGITUD (m) 610.20 AÑOS DE PROYECTO 20
COSTO DE KW/HOR. 1.50 HORAS DE BOMBEO 9
MOD. ELAST. MATERIAL 28,100 MOD. ELAST. AGUA 20,670
2 1 3 2 4 3 6 5 7 4
= x 0.7457 = x $ KWH = x 8760 = x ANUALIDAD = +
7
NOTA : EL DIÁMETRO MAS ECONÓMICO ESTA DADO POR EL MENOR COSTO DETERMINADO EL LA COLUMNA

(8) 414304806.xlsx 2 de 2
CABALLAJE
% HF (5%) Q HFT 76 N HP=Q*HFT/76*N
PERD. FRICC. OTRAS HFT=HF+%HF (Q EN lps) N=60% HP
EN m PERDIDAS

20.750 1.0375 21.79 174.30 45.6 3.8224


5.408 0.2704 5.68 45.43 45.6 0.9962
0.689 0.0345 0.72 5.79 45.6 0.1270

LPE DE ARIETE
SOBREPRESION SOBREPRESION SOBREPRESION PRESIÓN TOTAL
1+ Ead h= 145 V ABSORBIDA POR ABSORBIDA POR CARGA NORMAL 20% h+CARGA
E te 1+ Ead VÁLVULA TUBERÍA DE OPERACIÓN NORMAL DE
E te 80% h 20 % h (EN m) OPERACIÓN
4.18 53.11 42.49 10.62 80.42 91.04
4.20 31.92 25.54 6.38 64.31 70.69
4.18 14.80 11.84 2.96 59.35 62.31

OSTOS MATERIALES Y M.O.


DIÁMETRO: 6" CLASE: PVC-26 CEA
CANTIDAD U. P/U IMPORTE ANÁLISIS DEL DIÁMETRO
375.88 M3 25.88 9,727.86 MAS ECONÓMICO
93.97 M3 242.93 22,828.33
42.71 M3 114.22 4,878.79 LOCALIDAD:
186.45 M3 102.82 19,171.30 SANTIAGUITO
227.11 M3 40.51 9,200.24 MUNICIPIO:
610.20 ML 10.77 6,571.85SAN JUANITO DE ESCOBEDO
610.20 ML 159.78 97,497.76 FECHA:
0.00 PZA 0.00 AGOSTO DE 2013
ELABORO:
169,876.13 ING. J.S.M.C.

O MAS ECONÓMICO
COSTO TOTAL DE CARGO ANUAL DE AMORT. COSTO ANUAL PARA
4 CONDUCCIÓN COND. No. DE AÑOS
5 OPERACIÓN
6 365 DIAS
80,691.03 20,408.05 34,453.26
102,611.60 25,952.11 29,612.55
169,876.13 42,964.38 43,430.95

(8) 414304806.xlsx 3 de 3
4 6

(8) 414304806.xlsx 4 de 4
CALCULO DEL DIÁMETRO MAS ECONÓMICO DE COLUMNA Y TR
CABALLAJE
DIÁMETRO DIÁMETRO ÁREA GASTO VELOCIDAD LONGITUD Q2 COEF. FRICC. CTE. DE
INTERIOR NOMINAL m2 m3/seg. m/seg. LINEAL m3/seg. MANNING MANNING
m Pulg. (A) (Q) (V) en m. (L) (N) (K)
0.06271 2 1/2 0.0031 0.00800 2.590 61.00 0.00006 0.014 5236.326
0.07792 3 0.0048 0.00800 1.678 61.00 0.00006 0.014 1644.480
0.10226 4 0.0082 0.00800 0.974 61.00 0.00006 0.014 385.827

ANÁLISIS DE COSTOS MATERIALES Y M.O.


CONCEPTO DIÁMETRO 2.5" CLASE: FoGo C-40 DIÁMETRO 3" CLASE: FoGo C-40
CANTIDAD U. P/U IMPORTE CANTIDAD U. P/U IMPORTE

INSTALACIÓN DE TUBERÍA 61.00 ML 22.28 1359.08 61.00 ML 28.97 1767.17


SUMINISTRO DE TUBERÍA 61.00 ML 259.46 15827.06 61.00 ML 327.93 20003.73

COSTO TOTAL DE CONDUCCIÓN 17186.14 21770.90

COLUMNA MAS ECONÓMICA


PRESIÓN DE TRABAJO DIÁMETRO HP Kwh. COSTO POR HR. CARGO ANUAL
TUBERÍA KG/CM2 MM pulg. 1 2 BOMBEO $ 3 DE BOMBEO 4
176 63.5 2 1/2 3.77 2.8081 4.21 13,836.99
176 76.2 3 1.18 0.8819 1.32 4,345.54
155 101.6 4 0.28 0.2069 0.31 1,019.55

TREN DE DESCARGA MAS ECONÓMICO


DIÁMETRO NOMINAL GASTO EN long. EQUIVALENTE PERD. FRICC. Q HFT 76 N HP=Q*HFT/76*N Kwh.
PULG. m3/seg. EN m EN m (Q EN lps) N=60% HP 1 2
3.0 0.00800 22.2 2.763 22.108 45.6 0.48482 0.362
4.0 0.00800 24.7 0.663 5.303 45.6 0.11630 0.087
6.0 0.00800 38.8 0.120 0.957 45.6 0.02099 0.016

NOTA: EL POZO PROFUNDO YA CUENTA CON EL EQUIPAMIENTO, LA COLUMNA DE BOMBEO, TREN DE DESCARGA, SUBESTACION, ARRANCADOR, C
CLORACION, FALTANDO UNICAMENTE EL EQUIPO DE CLORACION.

2 = 1 x 0.7457 3 = 2 x $ KWH 4 = 3 x 8760 6 = 5 x ANUALIDAD 7 = 4 + 6


(8) 414304806.xlsx 5 de9
2 1 3 2 4 3 6 5 7 4 6

NOTA : EL DIÁMETRO MAS ECONÓMICO ESTA DADO POR EL MENOR COSTO DETERMINADO EL LA COLUMNA 7

(8) 414304806.xlsx 6 de9


ÓMICO DE COLUMNA Y TREN DE DESCARGA.
BALLAJE
% HF Q HFT 76 N HP=Q*HFT/76*N
PERD. FRICC. OTRAS HFT=HF+%HF (Q EN lps) N = 60% HP
m PERDIDAS m
m
20.443 1.0221 21.46 171.72 45.6 3.76575
6.420 0.3210 6.74 53.93 45.6 1.18264
1.506 0.0753 1.58 12.65 45.6 0.27747

TOS MATERIALES Y M.O.


DIÁMETRO 4" CLASE: FoGo C-40 CEA
CANTIDAD U. P/U IMPORTE LOCALIDAD:
PUENTE ALTO
61.00 ML 41.38 2524.18 MUNICIPIO:
61.00 ML 483.50 29493.50 LAS PALMAS

32017.68 ELABORO:

MAS ECONÓMICA
COSTO TOTAL DE CARGO ANUAL DE AMORT. COSTO ANUAL
5 7
COLUMNA COND. No. DE AÑOS 6 DE OPERACIÓN 7
17,186.14 4,346.65 18,183.64
21,770.90 5,506.21 9,851.75
32,017.68 8,097.78 9,117.33

RGA MAS ECONÓMICO


COSTO POR HR. CARGO ANUAL C. TOTAL TREN C. ANUAL DE AMORT. COSTO ANUAL
5 7
BOMBEO $ 3 DE BOMBEO 4 DE DESC. SUM. E INST. COND. No. DE AÑOS 6 DE OPERACIÓN 7
0.542 1781.43 12938.00 3272.23 5053.65
0.130 427.34 15367.00 3886.56 4313.90
0.023 77.12 29005.00 7335.83 7412.95

GA, SUBESTACION, ARRANCADOR, CERCO PERIMETRAL TIPO Y CASETA DE CONTROLES Y

6
(8) 414304806.xlsx 7 de9
6

(8) 414304806.xlsx 8 de9


CALCULO DE EQUIPO DE BOMBEO

LOCALIDAD: PUENTE ALTO MUNICIPIO: LAS PALMAS

1.- DATOS BÁSICOS

1.1.- CAPTACIÓN

TIPO POZO PROFUNDO


PROFUNDIDAD TOTAL 160 m
DIÁMETRO DE ADEME 10 PULG.
GASTO MAX. AFORADO 8.00 L.P.S.
NIVEL DINÁMICO 28.00 m

1.2.- CONDICIONES DE SERVICIO REQUERIDAS

GASTO A EXTRAER: 8.00 LPS POBLACIÓN BENEFICIADA: 915 HAB.


NIVEL DINÁMICO: 28.0 m DOTACIÓN: 205 L.P.S.
LONG. DE COLUMNA: 61.0 m DIAM. DE COLUMNA: 3.0 PULG.
LONG. LÍNEA DE COND. 610.20 m DIAM. DE LÍNEA DE COND.: 4.0 PULG.

NOTA: SE INSTALARA VÁLVULA DE ALIVIO DE PRESION, SOSTENEDORA DE


PRESIÓN Y AMORTIGUADORA DE GOLPE DE ARIETE DE 2" DE DIÁMETRO , CON
RANGO DE PRESIÓN DE 3.5 A 12.6 Kg/cm2, CALIBRADA A 9.481 Kg/cm2.

1.3.- CARGA DINÁMICA TOTAL:

POR DESNIVEL TOPOGRÁFICO 58.63 m


POR ALTURA DE TANQUE 2.84 m
POR NIVEL DINÁMICO 28.00 m
POR PERDIDAS POR FRICCIÓN EN LÍNEA DE CONDUCCIÓN 6.84 m
POR PERDIDAS POR FRICCIÓN EN COLUMNA DE BOMBEO 6.74 m
POR PERDIDAS POR FRICCIÓN EN ACCESORIOS 0.34 m
OTRAS PERDIDAS (TREN DE DESCARGA) 4" DE DIAMETRO. 0.66 m

SUMA 104.05 m.c.a.

CROQUIS DE SISTEMA DE BOMBEO TANQUES EXISTENTES


INTERCONECTADOS DE 40 Y
85 M3 DE CAPACIDAD
.00 m
POZO PROFUNDO
BOMBEO Qb=8.00 L.P.S.

DT= 58.63 m

TUBERÍA DE PVC Y Fo.G.o. DE 4" Ø. LONG. = 610.20 m


FECHA: MARZO 2019

414304806.xlsx