Está en la página 1de 2

VOLT(V): 440 mon-trif: 3 INGRESE

POT(HP): 15 ESTRELLA DELTA


Vnom(RPM): 3510 Npolos: 2.051282051 Vfase: 254.034118 440
FREC(HZ) 60 ==== 2 INGRESE
DF(in): 9.38 Vsinc(RPM): 3600 Vfase= 254 INGRESE
TR(in): 0.375 INGRESE

Dext(in): 8.63 8.63


Dint(in): 4.72366864
==== 4.72
pi: 3
Y1(in): 0.75 S1(ranuras): 19.77108977 18 Y1(in): 0.82379541
Y2(in): 1.125 S2(ranuras): 13.18072651 12 Y2(in): 1.23569311
Y3(in): 1.5 S3(ranuras): 9.885544883 6 Y3(in): 2.47138622
Y(req): 0.82 INGRESE
Ts(ft.lb): 22.4358974 Vt(in^3/ft.lb) 5.5 INGRESE
==== 22.44
La(in): 5.53989515
==== 5.54
FLUJO INICIAL
Om(mWb) 11.4253009
==== 11.43 por-polo

S1= 18 INGRESE
NS1(r/p/f): 3
Pp(r/p): 9 paso.polar
f(8/9 o 5/6): 0.89 INGRESE
Pb(grad): 160 paso.angularbobina
FACT.DE PASO Kp= 0.98480775
==== 0.98
YI(grad) 20 paso.angularde las ranuras
Kd: 0.95979508 factor de distribucion
==== 0.96
KW1: 0.9408 factor de devanado
==== 0.94
NUMERO DE CONDUCTORPOR RANURA
a=1: C1= 28.6929956 28 conductores
a=2: C2= 57.3859912 56 conductores
VALOR REAL DEL FLUJO MAXIMO POR POLO
a= 1 INGRESE
C= 28 INGRESE
Om(Mlineas)= 1.17128907 1.17
CORRIENTE PLENA CARGA
eficiencia(%): 0.85 INGRESE
I(Amp): 20.3225842 20.32
CONEXIÓN ESTRELLA DELTA
I(Amp): 20.32 11.7317575
I(Amp)= 20.32 INGRESE
SECCION DEL CONDUCTORJ(A/in^2)= 4200 INGRESE
Sa1(10^-3*in^24.83809524
Sa1(mm^2): 3.12134552
DISEÑO DE LA RANURA
Fbs1= 0.55 INGRESE
bs1(in): 0.451 0.45
Fds1= 3 INGRESE
ds1(in): 1.35 1.35
ts1(in): 0.37 0.37
DENSIDAD MAXIMA DE FLUJO APARENTE
F.A= 0.96
Bstm: 103.774041 103.77 klineas/in^2
DENSIDAD MAXIMA DE FLUJO DEL NUCLEO
Bscm: 181.810723 181.81 klineas/in^2