Está en la página 1de 14

1.

- CONSIDERACIONES DE DISEÑO

Caudal : 18 LPS
Tipo de Tubería: PVC-5
Presión en la Tubería:
maxima 50 m.c.a.
minima 1 m.c.a.
Velociadad en tuberia:
minima 0.6 m/s
maxima 5 m/s

2.- CÁLCULO DE LOS DIÁMETROS MAXIMO Y MÍNIMO

4Q 4Q
Dmax  D min 
 Vmin  Vmax

Dmax 0.195441 m
Dmin 0.06770275 m
Dmax 7.69452775 in
Dmin 2.6654626 in

Diámetros comerciales

Dmax 6 in
Dmin 3 in
Ddisp 4 in

3.- CÁLCULO DE LA GRADIENTE DE ENERGIA

hf L Q 1.85
 Sf  10.7 1.85 4.87
L C D
Diam
in 3 4 6
mtrs 0.0762 0.1016 0.1524
Sf 0.189 0.047 0.006
Sf% 18.888 4.653 0.646

4.- DISEÑO DE LA TUBERÍA Y VERIFICACIÓN DE PRESIONES

COORDENADAS tuberia longitud


PTO X Y diam in diam m vertical alt acum horizontal
1 0.00 120.00 3 0.0762 0 0.00 0
2 35.90 110.00 3 0.0762 10 10.00 35.90
3 67.59 100.00 3 0.0762 10 20.00 31.70
4 87.34 90.00 3 0.0762 10 30.00 19.75
5 97.04 80.00 3 0.0762 10 40.00 9.70
6 100.00 78.43 3 0.0762 1.5742 41.57 2.96
7 127.53 73.60 3 0.0762 4.8294 46.40 27.53
8 142.06 76.21 4 0.1016 -2.6167 43.79 14.53
9 159.23 80.00 4 0.1016 -3.7869 40.00 17.17
10 173.66 85.84 4 0.1016 -5.8429 34.16 14.44
11 186.67 89.29 4 0.1016 -3.4467 30.71 13.01
12 200.00 89.98 4 0.1016 -0.6916 30.02 13.33
13 218.15 89.24 4 0.1016 0.7389 30.76 18.15
14 246.79 80.00 4 0.1016 9.2423 40.00 28.64
15 265.96 70.00 3 0.0762 10 50.00 19.17
16 279.60 60.00 3 0.0762 10 60.00 13.63
17 300.36 47.67 3 0.0762 12.3258 72.33 20.76
18 255.72 42.49 3 0.0762 5.1855 77.51 44.64
19 227.19 40.00 3 0.0762 2.4887 80.00 28.53
20 211.81 35.59 3 0.0762 4.4056 84.41 15.38
21 236.34 31.54 3 0.0762 4.0543 88.46 24.54
22 287.65 31.24 4 0.1016 0.2959 88.76 51.31
23 300.00 30.94 4 0.1016 0.3053 89.06 12.35
24 326.76 29.30 4 0.1016 1.6347 90.70 26.76
25 341.99 30.00 4 0.1016 -0.6958 90.00 15.23
26 378.90 40.00 4 0.1016 -10 80.00 36.91
27 388.13 43.86 4 0.1016 -3.8598 76.14 9.23
28 400.00 46.91 4 0.1016 -3.0551 73.09 11.87
29 418.58 46.66 4 0.1016 0.2596 73.34 18.58
30 429.57 40.00 4 0.1016 6.6553 80.00 10.99
31 441.39 30.00 4 0.1016 10 90.00 11.82
32 453.53 23.75 4 0.1016 6.253 96.25 12.14
33 489.55 20.00 4 0.1016 3.747 100.00 36.02
34 500.00 19.80 4 0.1016 0.2009 100.20 10.45
35 528.33 19.58 4 0.1016 0.2146 100.42 28.33
36 555.11 20.00 4 0.1016 -0.4155 100.00 26.78
37 600.00 25.28 4 0.1016 -5.2834 94.72 44.89
38 624.94 30.00 4 0.1016 -4.7166 90.00 24.94
39 652.21 31.53 4 0.1016 -1.5298 88.47 27.26
40 684.46 30.00 4 0.1016 1.5298 90.00 32.25
41 700.00 27.77 4 0.1016 2.2316 92.23 15.55
42 733.01 20.00 4 0.1016 7.7684 100.00 33.01
43 744.97 17.99 4 0.1016 2.0117 102.01 11.97
44 768.49 20.00 4 0.1016 -2.0117 100.00 23.51
45 800.00 22.36 4 0.1016 -2.3634 97.64 31.51
46 856.99 20.00 4 0.1016 2.3634 100.00 56.99
47 900.68 14.97 4 0.1016 5.0321 105.03 43.69
48 932.29 10.00 3 0.0762 4.9679 110.00 31.61
49 1000 -0.8 3 0.0762 10.789 120.79 67.71
ENERGIA C.P = 120
real Sf% perdida perd acum presion cota piez
18.8878 0 0 0 120
37.27 18.8878 6.780 6.78 3.220 113.220
33.24 18.8878 5.987 12.77 7.233 107.233
22.14 18.8878 3.730 16.50 13.503 103.503
13.93 18.8878 1.831 18.33 21.672 101.672
3.35 18.8878 0.560 18.89 22.686 101.112
27.95 18.8878 5.200 24.09 22.316 95.912 137.87
14.76 4.653 0.676 24.76 19.023 95.236
17.58 4.653 0.799 25.56 14.437 94.437
15.58 4.653 0.672 26.23 7.923 93.766
13.46 4.653 0.605 26.84 3.871 93.160
13.34 4.653 0.620 27.46 2.559 92.540
18.17 4.653 0.845 28.30 2.453 91.696
30.09 4.653 1.333 29.64 10.363 90.363 122.98
21.62 18.8878 3.621 33.26 16.742 86.742
16.91 18.8878 2.575 35.83 24.167 84.167
24.15 18.8878 3.922 39.75 32.571 80.245
44.94 18.8878 8.431 48.19 29.325 71.814
28.64 18.8878 5.389 53.58 26.425 66.425
16.00 18.8878 2.905 56.48 27.925 63.520
24.87 18.8878 4.634 61.11 27.345 58.885
51.31 4.653 2.387 63.50 25.254 56.498
12.35 4.653 0.574 64.08 24.984 55.923
26.81 4.653 1.245 65.32 25.374 54.678
15.25 4.653 0.709 66.03 23.970 53.970
38.24 4.653 1.717 67.75 12.252 52.252
10.01 4.653 0.430 68.18 7.963 51.823
12.26 4.653 0.552 68.73 4.355 51.270 331.09
18.58 4.653 0.864 69.59 3.751 50.406
12.85 4.653 0.511 70.11 9.895 49.895
15.49 4.653 0.550 70.66 19.344 49.344
13.66 4.653 0.565 71.22 25.032 48.779
36.21 4.653 1.676 72.90 27.104 47.104
10.45 4.653 0.486 73.38 26.818 46.617
28.33 4.653 1.318 74.70 25.714 45.299
26.78 4.653 1.246 75.95 24.053 44.053
45.20 4.653 2.089 78.04 16.681 41.964
25.38 4.653 1.161 79.20 10.804 40.804
27.31 4.653 1.269 80.46 8.005 39.535
32.29 4.653 1.501 81.97 8.035 38.035
15.70 4.653 0.723 82.69 9.543 37.311
33.91 4.653 1.536 84.22 15.776 35.776
12.13 4.653 0.557 84.78 17.230 35.219
23.60 4.653 1.094 85.88 14.125 34.125
31.60 4.653 1.466 87.34 10.295 32.658
57.04 4.653 2.652 89.99 10.006 30.006
43.98 4.653 2.033 92.03 13.006 27.974
32.00 18.8878 5.971 98.00 12.003 22.003
68.56 18.8878 12.788 110.79 10.003 10.003
120.00

110.00

100.00

90.00
100.00

90.00

80.00

70.00

60.00

50.00

40.00

30.00

20.00

10.00

0.00
0.00 100.00 200.00 300.00 400.00 500.00 600.00 700.00
500.00 600.00 700.00 800.00 900.00 1000.00
1.- CONSIDERACIONES DE DISEÑO

Caudal : 18 LPS
Tipo de Tubería: PVC-5
Presión en la Tubería:
maxima 50 m.c.a.
minima 1 m.c.a.
Velociadad en tuberia:
minima 0.6 m/s
maxima 5 m/s

2.- CÁLCULO DE LOS DIÁMETROS MAXIMO Y MÍNIMO

4Q 4Q
Dmax  D min 
 Vmin  Vmax

Diámetros nominales

Dmax 0.195441 m
Dmin 0.06770275 m
Dmax 7.69452775 in
Dmin 2.6654626 in

Diámetros comerciales

Dmax 6 in
Dmin 3 in
Ddisp 4 in

3.- CÁLCULO DE LA GRADIENTE DE ENERGIA

hf L Q 1.85
 Sf  10.7 1.85 4.87
L C D

Diam (in)
in 3 4 6
mtrs 0.0762 0.1016 0.1524
Sf 0.189 0.047 0.006
Sf% 18.888 4.653 0.646
4.- DISEÑO DE LA TUBERÍA Y VERIFICACIÓN DE PRESIONES

COORDENADAS LONG TUB ENERGIA C.P = 120


PTO Ø in PERDIDAS mtrs
X Y mtrs presión (m) cota piez (m)
1 0.00 120.00 3 0 0 0 120
2 35.90 110.00 3 37.27 6.78 3.22 113.22
3 67.59 100.00 3 33.24 5.99 7.23 107.23
4 87.34 90.00 3 22.14 3.73 13.50 103.50
5 97.04 80.00 3 13.93 1.83 21.67 101.67
6 100.00 78.43 3 3.35 0.56 22.69 101.11
7 127.53 73.60 3 27.95 5.20 22.32 95.91
8 142.06 76.21 4 14.76 0.68 19.02 95.24
9 159.23 80.00 4 17.58 0.80 14.44 94.44
10 173.66 85.84 4 15.58 0.67 7.92 93.77
11 186.67 89.29 4 13.46 0.61 3.87 93.16
12 200.00 89.98 4 13.34 0.62 2.56 92.54
13 218.15 89.24 4 18.17 0.84 2.45 91.70
14 246.79 80.00 4 30.09 1.33 10.36 90.36
15 265.96 70.00 3 21.62 3.62 16.74 86.74
16 279.60 60.00 3 16.91 2.57 24.17 84.17
17 300.36 47.67 3 24.15 3.92 32.57 80.25
18 255.72 42.49 3 44.94 8.43 29.33 71.81
19 227.19 40.00 3 28.64 5.39 26.42 66.42
20 211.81 35.59 3 16.00 2.90 27.93 63.52
21 236.34 31.54 3 24.87 4.63 27.35 58.89
22 287.65 31.24 4 51.31 2.39 25.25 56.50
23 300.00 30.94 4 12.35 0.57 24.98 55.92
24 326.76 29.30 4 26.81 1.25 25.37 54.68
25 341.99 30.00 4 15.25 0.71 23.97 53.97
26 378.90 40.00 4 38.24 1.72 12.25 52.25
27 388.13 43.86 4 10.01 0.43 7.96 51.82
28 400.00 46.91 4 12.26 0.55 4.36 51.27
29 418.58 46.66 4 18.58 0.86 3.75 50.41
30 429.57 40.00 4 12.85 0.51 9.89 49.89
31 441.39 30.00 4 15.49 0.55 19.34 49.34
32 453.53 23.75 4 13.66 0.56 25.03 48.78
33 489.55 20.00 4 36.21 1.68 27.10 47.10
34 500.00 19.80 4 10.45 0.49 26.82 46.62
35 528.33 19.58 4 28.33 1.32 25.71 45.30
36 555.11 20.00 4 26.78 1.25 24.05 44.05
37 600.00 25.28 4 45.20 2.09 16.68 41.96
38 624.94 30.00 4 25.38 1.16 10.80 40.80
39 652.21 31.53 4 27.31 1.27 8.01 39.54
40 684.46 30.00 4 32.29 1.50 8.03 38.03
41 700.00 27.77 4 15.70 0.72 9.54 37.31
42 733.01 20.00 4 33.91 1.54 15.78 35.78
43 744.97 17.99 4 12.13 0.56 17.23 35.22

COORDENADAS ENERGIA C.P = 120


PTO Ø in LONG TUB pérdida
X Y presión cota piez
44 768.49 20.00 4 23.60 1.09 14.12 34.12
45 800.00 22.36 4 31.60 1.47 10.29 32.66
46 856.99 20.00 4 57.04 2.65 10.01 30.01
47 900.68 14.97 4 43.98 2.03 13.01 27.97
48 932.29 10.00 3 32.00 5.97 12.00 22.00
49 1000.00 -0.80 3 68.56 12.79 10.00 10.00

TERRENO ENERGIA

120.00

110.00

100.00

90.00

80.00

70.00

60.00

50.00

40.00

30.00

20.00

10.00

0.00
0.00 100.00 200.00 300.00 400.00 500.00 600.00 700.00 800.00 900.00 1000.00
20.00

10.00

0.00
0.00 100.00 200.00 300.00 400.00 500.00 600.00 700.00 800.00 900.00 1000.00

También podría gustarte