Documentos de Académico
Documentos de Profesional
Documentos de Cultura
FACULTAD DE ARQUITECTURA E
INGENIERIA CIVIL
PROYECTO DE ABASTECIMIENTO DE
AGUA Y ALCANTARILLADO
PARTE 2
ALCANTARILLADO
SEMESTRE : 2017 – 1
CUSCO – PERU
2017
1
CONTENIDO DEL INFORME
CONTENIDO DEL INFORME ........................................................................................................... 2
1. INTRODUCCION ..................................................................................................................... 4
2. OBJETIVOS ............................................................................................................................. 5
1.1. ESCENARIO 1 ..................................................................................................................... 6
1.2. DATOS DEL TANK 1 ............................................................................................................ 6
1.1. DATOS DE LOS HIDRANTES................................................................................................ 6
5.1. DATOS DE LOS NODOS .................................................................................................... 14
5.2. DATOS DE LA TUBERIA .................................................................................................... 15
6. ESCENARIO 6 ................................................................................................................... 16
6.1. DATOS DE LOS NODOS .................................................................................................... 16
6.2. DATOS DE LA TUBERIA .................................................................................................... 17
7. ESCENARIO 7 ................................................................................................................... 18
7.1. DATOS DEL TANK 1 .......................................................................................................... 18
7.2. DATOS DE LOS NODOS .................................................................................................... 18
7.3. DATOS DE LA TUBERIA .................................................................................................... 19
8. ESCENARIO 8 ................................................................................................................... 20
8.1. DATOS DEL TANK 1 .......................................................................................................... 20
8.2. DATOS DE LOS NODOS .................................................................................................... 20
8.3. DATOS DE LA TUBERIA .................................................................................................... 21
9. ESCENARIO 9 ................................................................................................................... 22
9.1. DATOS DE LOS NODOS .................................................................................................... 22
9.2. DATOS DE LA TUBERIA .................................................................................................... 23
10. ESCENARIO 10 ............................................................................................................. 24
10.1. DATOS DE LOS NODOS ................................................................................................ 24
10.2 DATOS DE LAS TUBERIAS ................................................................................................. 25
5.1. DATOS DE LOS NODOS .................................................................................................... 34
5.2. DATOS DE LA TUBERIA .................................................................................................... 35
6. ESCENARIO 16 ................................................................................................................. 36
6.1. DATOS DEL TANK 1 .......................................................................................................... 36
6.2. DATOS DE LOS NODOS .................................................................................................... 36
6.3. DATOS DE LA TUBERIA .................................................................................................... 37
7. ESCENARIO 17 ................................................................................................................. 38
7.1. DATOS DE LOS NODOS .................................................................................................... 38
2
7.2. DATOS DE LA TUBERIA .................................................................................................... 39
8. ESCENARIO 18 ................................................................................................................. 40
8.1. DATOS DE LOS NODOS .................................................................................................... 40
8.2. DATOS DE LA TUBERIA .................................................................................................... 41
9. ESCENARIO 19 ................................................................................................................. 42
9.1. DATOS DEL TANK 1 .......................................................................................................... 42
9.2. DATOS DE LOS NODOS .................................................................................................... 42
9.3. DATOS DE LA TUBERIA .................................................................................................... 43
10. ESCENARIO 20 ............................................................................................................. 44
10.1. DATOS DE LOS NODOS ................................................................................................ 44
10.2. DATOS DE LA TUBERIA ................................................................................................ 45
11.0 CONCLUSIONES ............................................................................................................... 46
CONTENIDO DEL CD
3.- INFORME
3
1. INTRODUCCION
El sistema de agua potable debe contar con todos los elementos necesarios para captar,
conducir, almacenar, tratar y distribuir de una manera eficiente el agua hasta los distintos
sectores en la que ésta va a ser servida.
Este sistema de agua potable entonces debe respetar las normativas vigentes que
garantizan la calidad del agua potable que se quiere suministrar, reduciendo así
enfermedades y muertes en las poblaciones que se benefician de este tipo de sistemas.
4
2. OBJETIVOS
Colocar los hidrantes contra incendios de modo que la distancia entre ellos
no sea mayor a 300m tal como lo establece el reglamento nacional de
edificaciones.
5
1.1. ESCENARIO 1
En este primer escenario se colocaron los datos de los hidrantes y de los tanques
6
1.3. DATOS DE LAS TUBERIA
7
2. ESCENARIO 2
Al ver que no cumplían con las presiones mínimas entonces modificamos las demandas
de los nodos subrayados.
8
2.2. DATOS DE TUBERIA
9
3. ESCENARIO 3
Como en el caso anterior al ver que hay presiones que no cumplen con el mínimo
especificado en la norma (R.N.E.) cambiamos la demanda de los nodos subrayados.
10
3.2. DATOS DE LA TUBERIA
11
4. ESCENARIO 4
Se aumentó la demanda en el nodo uno (J-1).
12
4.2. DATOS DE LA TUBERIA
13
5. ESCENARIO 5
Al ver que cuando aumentamos la demanda del nodo (J-1), disminuye la presión del
nodo 1 , disminuimos la demanda del nodo 1.
14
5.2. DATOS DE LA TUBERIA
15
6. ESCENARIO 6
Al ver que cumple cambiamos de material de hierro dúctil a PVC y como vemos la
presión en el nodo 1 (J-1) a 5.6 mh20.
16
6.2. DATOS DE LA TUBERIA
17
7. ESCENARIO 7
En este escenario al ver que no cumple las presiones mínimas elevamos las cotas de
los reservorios en un metro.
18
7.3. DATOS DE LA TUBERIA
19
8. ESCENARIO 8
En este escenario cambiamos el material de tubería p-23 de hierro dúctil a PVC, y
también cambiamos las cotas de los reservorios una distancia de 2m.
20
8.3. DATOS DE LA TUBERIA
21
9. ESCENARIO 9
22
9.2. DATOS DE LA TUBERIA
23
10. ESCENARIO 10
Este es el escenario al ver que no cumplía se cambió los diámetros de las tuberías P-4
y P-5 a 6 pulgadas.
24
10.2 DATOS DE LAS TUBERIAS
25
1. ESCENARIO 11
En este escenario se cambió la dotación del nodo 1 (J-1), para que la presión de este
nodo pueda ser más aproximada a 10 que es la presión mínima.
26
1.4. DATOS DE LAS TUBERIA
Length Start Stop Diameter Hazen- Has Check Minor Loss Flow Velocity Headloss Has User Length (User
Label (Scalet) (m) Node Node (pulg) Material Williams C Valve Coefficient (lt/seg) (m/seg) Gradient Defined Define) (m)
(local) (m/m) Length
P-1 263 T-1 J-1 6 PVC 150 False 0 37.93 2.08 0.022 True 278
P-2 478 J-1 J-2 6 PVC 150 False 0 5.44 0.3 0.001 True 481
P-4 313 J-3 J-4 6 PVC 150 False 0 -0.93 0.05 0 True 314
P-5 365 J-4 J-2 6 PVC 150 False 0 -3.03 0.17 0 True 370
P-6 231 J-1 J-5 4 PVC 150 False 0 16.77 2.07 0.035 True 228
P-7 97 J-5 J-6 4 PVC 150 False 0 7.65 0.94 0.008 True 90
P-8 272 J-6 J-7 4 PVC 150 False 0 4.76 0.59 0.003 True 268
P-9 91 J-7 J-8 4 PVC 150 False 0 -3.61 0.45 0.002 True 90
P-12 169 J-9 J-8 4 PVC 150 False 0 6.13 0.76 0.005 True 174
P-13 326 J-9 J-10 4 PVC 150 False 0 6.64 0.82 0.006 True 322
P-14 173 J-10 J-11 4 PVC 150 False 0 2.6 0.32 0.001 True 174
P-15 308 J-11 J-8 4 PVC 150 False 0 -5.31 0.65 0.004 True 306
P-16 93 J-11 J-12 4 PVC 150 False 0 1.51 0.19 0 True 94
P-19 224 J-13 J-14 4 PVC 150 False 0 1.43 0.18 0 True 224
P-21 485 J-12 J-15 4 PVC 150 False 0 3 0.37 0.001 True 482
P-22 151 J-15 J-14 4 PVC 150 False 0 -1.28 0.16 0 True 154
P-23 334 T-2 J-16 6 PVC 150 False 0 2.72 0.15 0 True 356
P-24 81 J-16 J-17 4 PVC 150 False 0 1.21 0.15 0 True 86
P-25 313 J-17 J-18 4 PVC 150 False 0 0.53 0.07 0 True 313
P-26 65 J-18 J-19 4 PVC 150 False 0 -0.15 0.02 0 True 65
P-27 305 J-19 J-16 4 PVC 150 False 0 -0.83 0.1 0 True 305
P-37 265 J-1 H-1 4 PVC 150 False 0 13.83 1.71 0.025 True 261
P-38 88 H-1 J-9 4 PVC 150 False 0 13.83 1.71 0.025 True 86
P-41 173 J-5 H-2 4 PVC 150 False 0 6.18 0.76 0.006 True 175
P-42 90 H-2 J-8 4 PVC 150 False 0 6.18 0.76 0.006 True 91
P-43 107 J-12 H-3 4 PVC 150 False 0 -4.89 0.6 0.004 True 108
P-44 207 H-3 J-7 4 PVC 150 False 0 -4.89 0.6 0.004 True 208
P-45 407 J-10 H-4 4 PVC 150 False 0 3.06 0.38 0.002 True 407
P-46 127 H-4 J-13 4 PVC 150 False 0 3.06 0.38 0.002 True 127
P-47 92 J-2 H-5 4 PVC 150 False 0 0.99 0.12 0 True 91
P-48 358 H-5 J-3 4 PVC 150 False 0 0.99 0.12 0 True 354
P-49 368 J-11 H-6 4 PVC 150 False 0 3.03 0.37 0.001 True 364
P-50 105 H-6 J-14 4 PVC 150 False 0 3.03 0.37 0.001 True 104
27
2. ESCENARIO 12
Igual que en el escenario anterior se cambió la demanda del nodo 1 (J-1).
28
2.2. DATOS DE TUBERIA
Length Start Stop Diameter Hazen- Has Check Minor Loss Flow Velocity Headloss Has User Length (User
Label (Scalet) (m) Node Node (pulg) Material Williams C Valve Coefficient (lt/seg) (m/seg) Gradient Defined Define) (m)
(local) (m/m) Length
P-1 263 T-1 J-1 6 PVC 150 False 0 38.14 2.09 0.022 True 278
P-2 478 J-1 J-2 6 PVC 150 False 0 5.44 0.3 0.001 True 481
P-4 313 J-3 J-4 6 PVC 150 False 0 -0.93 0.05 0 True 314
P-5 365 J-4 J-2 6 PVC 150 False 0 -3.03 0.17 0 True 370
P-6 231 J-1 J-5 4 PVC 150 False 0 16.77 2.07 0.035 True 228
P-7 97 J-5 J-6 4 PVC 150 False 0 7.65 0.94 0.008 True 90
P-8 272 J-6 J-7 4 PVC 150 False 0 4.76 0.59 0.003 True 268
P-9 91 J-7 J-8 4 PVC 150 False 0 -3.61 0.45 0.002 True 90
P-12 169 J-9 J-8 4 PVC 150 False 0 6.13 0.76 0.005 True 174
P-13 326 J-9 J-10 4 PVC 150 False 0 6.64 0.82 0.006 True 322
P-14 173 J-10 J-11 4 PVC 150 False 0 2.6 0.32 0.001 True 174
P-15 308 J-11 J-8 4 PVC 150 False 0 -5.31 0.65 0.004 True 306
P-16 93 J-11 J-12 4 PVC 150 False 0 1.51 0.19 0 True 94
P-19 224 J-13 J-14 4 PVC 150 False 0 1.43 0.18 0 True 224
P-21 485 J-12 J-15 4 PVC 150 False 0 3 0.37 0.001 True 482
P-22 151 J-15 J-14 4 PVC 150 False 0 -1.28 0.16 0 True 154
P-23 334 T-2 J-16 6 PVC 150 False 0 2.72 0.15 0 True 356
P-24 81 J-16 J-17 4 PVC 150 False 0 1.21 0.15 0 True 86
P-25 313 J-17 J-18 4 PVC 150 False 0 0.53 0.07 0 True 313
P-26 65 J-18 J-19 4 PVC 150 False 0 -0.15 0.02 0 True 65
P-27 305 J-19 J-16 4 PVC 150 False 0 -0.83 0.1 0 True 305
P-37 265 J-1 H-1 4 PVC 150 False 0 13.83 1.71 0.025 True 261
P-38 88 H-1 J-9 4 PVC 150 False 0 13.83 1.71 0.025 True 86
P-41 173 J-5 H-2 4 PVC 150 False 0 6.18 0.76 0.006 True 175
P-42 90 H-2 J-8 4 PVC 150 False 0 6.18 0.76 0.006 True 91
P-43 107 J-12 H-3 4 PVC 150 False 0 -4.89 0.6 0.004 True 108
P-44 207 H-3 J-7 4 PVC 150 False 0 -4.89 0.6 0.004 True 208
P-45 407 J-10 H-4 4 PVC 150 False 0 3.06 0.38 0.002 True 407
P-46 127 H-4 J-13 4 PVC 150 False 0 3.06 0.38 0.002 True 127
P-47 92 J-2 H-5 4 PVC 150 False 0 0.99 0.12 0 True 91
P-48 358 H-5 J-3 4 PVC 150 False 0 0.99 0.12 0 True 354
P-49 368 J-11 H-6 4 PVC 150 False 0 3.03 0.37 0.001 True 364
P-50 105 H-6 J-14 4 PVC 150 False 0 3.03 0.37 0.001 True 104
29
3. ESCENARIO 13
Bajamos la demanda del nodo 1 (J-1) para llegar a una presión aproximada superior a
10 mH2O.
30
3.2. DATOS DE LA TUBERIA
Length Start Stop Diameter Hazen- Has Check Minor Loss Flow Velocity Headloss Has User Length (User
Label (Scalet) (m) Node Node (pulg) Material Williams C Valve Coefficient (lt/seg) (m/seg) Gradient Defined Define) (m)
(local) (m/m) Length
P-1 263 T-1 J-1 6 PVC 150 False 0 37.94 2.08 0.022 True 278
P-2 478 J-1 J-2 6 PVC 150 False 0 5.44 0.3 0.001 True 481
P-4 313 J-3 J-4 6 PVC 150 False 0 -0.93 0.05 0 True 314
P-5 365 J-4 J-2 6 PVC 150 False 0 -3.03 0.17 0 True 370
P-6 231 J-1 J-5 4 PVC 150 False 0 16.77 2.07 0.035 True 228
P-7 97 J-5 J-6 4 PVC 150 False 0 7.65 0.94 0.008 True 90
P-8 272 J-6 J-7 4 PVC 150 False 0 4.76 0.59 0.003 True 268
P-9 91 J-7 J-8 4 PVC 150 False 0 -3.61 0.45 0.002 True 90
P-12 169 J-9 J-8 4 PVC 150 False 0 6.13 0.76 0.005 True 174
P-13 326 J-9 J-10 4 PVC 150 False 0 6.64 0.82 0.006 True 322
P-14 173 J-10 J-11 4 PVC 150 False 0 2.6 0.32 0.001 True 174
P-15 308 J-11 J-8 4 PVC 150 False 0 -5.31 0.65 0.004 True 306
P-16 93 J-11 J-12 4 PVC 150 False 0 1.51 0.19 0 True 94
P-19 224 J-13 J-14 4 PVC 150 False 0 1.43 0.18 0 True 224
P-21 485 J-12 J-15 4 PVC 150 False 0 3 0.37 0.001 True 482
P-22 151 J-15 J-14 4 PVC 150 False 0 -1.28 0.16 0 True 154
P-23 334 T-2 J-16 6 PVC 150 False 0 2.72 0.15 0 True 356
P-24 81 J-16 J-17 4 PVC 150 False 0 1.21 0.15 0 True 86
P-25 313 J-17 J-18 4 PVC 150 False 0 0.53 0.07 0 True 313
P-26 65 J-18 J-19 4 PVC 150 False 0 -0.15 0.02 0 True 65
P-27 305 J-19 J-16 4 PVC 150 False 0 -0.83 0.1 0 True 305
P-37 265 J-1 H-1 4 PVC 150 False 0 13.83 1.71 0.025 True 261
P-38 88 H-1 J-9 4 PVC 150 False 0 13.83 1.71 0.025 True 86
P-41 173 J-5 H-2 4 PVC 150 False 0 6.18 0.76 0.006 True 175
P-42 90 H-2 J-8 4 PVC 150 False 0 6.18 0.76 0.006 True 91
P-43 107 J-12 H-3 4 PVC 150 False 0 -4.89 0.6 0.004 True 108
P-44 207 H-3 J-7 4 PVC 150 False 0 -4.89 0.6 0.004 True 208
P-45 407 J-10 H-4 4 PVC 150 False 0 3.06 0.38 0.002 True 407
P-46 127 H-4 J-13 4 PVC 150 False 0 3.06 0.38 0.002 True 127
P-47 92 J-2 H-5 4 PVC 150 False 0 0.99 0.12 0 True 91
P-48 358 H-5 J-3 4 PVC 150 False 0 0.99 0.12 0 True 354
P-49 368 J-11 H-6 4 PVC 150 False 0 3.03 0.37 0.001 True 364
P-50 105 H-6 J-14 4 PVC 150 False 0 3.03 0.37 0.001 True 104
31
4. ESCENARIO 14
Se aumentó la demanda en el nodo uno (J-1).
32
4.2. DATOS DE LA TUBERIA
Length Start Stop Diameter Hazen- Has Check Minor Loss Flow Velocity Headloss Has User Length (User
Label (Scalet) (m) Node Node (pulg) Material Williams C Valve Coefficient (lt/seg) (m/seg) Gradient Defined Define) (m)
(local) (m/m) Length
P-1 263 T-1 J-1 6 PVC 150 False 0 38.29 2.1 0.023 True 278
P-2 478 J-1 J-2 6 PVC 150 False 0 5.44 0.3 0.001 True 481
P-4 313 J-3 J-4 6 PVC 150 False 0 -0.93 0.05 0 True 314
P-5 365 J-4 J-2 6 PVC 150 False 0 -3.03 0.17 0 True 370
P-6 231 J-1 J-5 4 PVC 150 False 0 16.77 2.07 0.035 True 228
P-7 97 J-5 J-6 4 PVC 150 False 0 7.65 0.94 0.008 True 90
P-8 272 J-6 J-7 4 PVC 150 False 0 4.76 0.59 0.003 True 268
P-9 91 J-7 J-8 4 PVC 150 False 0 -3.61 0.45 0.002 True 90
P-12 169 J-9 J-8 4 PVC 150 False 0 6.13 0.76 0.005 True 174
P-13 326 J-9 J-10 4 PVC 150 False 0 6.64 0.82 0.006 True 322
P-14 173 J-10 J-11 4 PVC 150 False 0 2.6 0.32 0.001 True 174
P-15 308 J-11 J-8 4 PVC 150 False 0 -5.31 0.65 0.004 True 306
P-16 93 J-11 J-12 4 PVC 150 False 0 1.51 0.19 0 True 94
P-19 224 J-13 J-14 4 PVC 150 False 0 1.43 0.18 0 True 224
P-21 485 J-12 J-15 4 PVC 150 False 0 3 0.37 0.001 True 482
P-22 151 J-15 J-14 4 PVC 150 False 0 -1.28 0.16 0 True 154
P-23 334 T-2 J-16 6 PVC 150 False 0 2.72 0.15 0 True 356
P-24 81 J-16 J-17 4 PVC 150 False 0 1.21 0.15 0 True 86
P-25 313 J-17 J-18 4 PVC 150 False 0 0.53 0.07 0 True 313
P-26 65 J-18 J-19 4 PVC 150 False 0 -0.15 0.02 0 True 65
P-27 305 J-19 J-16 4 PVC 150 False 0 -0.83 0.1 0 True 305
P-37 265 J-1 H-1 4 PVC 150 False 0 13.83 1.71 0.025 True 261
P-38 88 H-1 J-9 4 PVC 150 False 0 13.83 1.71 0.025 True 86
P-41 173 J-5 H-2 4 PVC 150 False 0 6.18 0.76 0.006 True 175
P-42 90 H-2 J-8 4 PVC 150 False 0 6.18 0.76 0.006 True 91
P-43 107 J-12 H-3 4 PVC 150 False 0 -4.89 0.6 0.004 True 108
P-44 207 H-3 J-7 4 PVC 150 False 0 -4.89 0.6 0.004 True 208
P-45 407 J-10 H-4 4 PVC 150 False 0 3.06 0.38 0.002 True 407
P-46 127 H-4 J-13 4 PVC 150 False 0 3.06 0.38 0.002 True 127
P-47 92 J-2 H-5 4 PVC 150 False 0 0.99 0.12 0 True 91
P-48 358 H-5 J-3 4 PVC 150 False 0 0.99 0.12 0 True 354
P-49 368 J-11 H-6 4 PVC 150 False 0 3.03 0.37 0.001 True 364
P-50 105 H-6 J-14 4 PVC 150 False 0 3.03 0.37 0.001 True 104
33
5. ESCENARIO 15
En este escenario se redujo la demanda en 0.05 lt/seg al nodo 1.
34
5.2. DATOS DE LA TUBERIA
Length Start Stop Diameter Hazen- Has Check Minor Loss Flow Velocity Headloss Has User Length (User
Label (Scalet) (m) Node Node (pulg) Material Williams C Valve Coefficient (lt/seg) (m/seg) Gradient Defined Define) (m)
(local) (m/m) Length
P-1 263 T-1 J-1 6 PVC 150 False 0 38.24 2.1 0.023 True 278
P-2 478 J-1 J-2 6 PVC 150 False 0 5.44 0.3 0.001 True 481
P-4 313 J-3 J-4 6 PVC 150 False 0 -0.93 0.05 0 True 314
P-5 365 J-4 J-2 6 PVC 150 False 0 -3.03 0.17 0 True 370
P-6 231 J-1 J-5 4 PVC 150 False 0 16.77 2.07 0.035 True 228
P-7 97 J-5 J-6 4 PVC 150 False 0 7.65 0.94 0.008 True 90
P-8 272 J-6 J-7 4 PVC 150 False 0 4.76 0.59 0.003 True 268
P-9 91 J-7 J-8 4 PVC 150 False 0 -3.61 0.45 0.002 True 90
P-12 169 J-9 J-8 4 PVC 150 False 0 6.13 0.76 0.005 True 174
P-13 326 J-9 J-10 4 PVC 150 False 0 6.64 0.82 0.006 True 322
P-14 173 J-10 J-11 4 PVC 150 False 0 2.6 0.32 0.001 True 174
P-15 308 J-11 J-8 4 PVC 150 False 0 -5.31 0.65 0.004 True 306
P-16 93 J-11 J-12 4 PVC 150 False 0 1.51 0.19 0 True 94
P-19 224 J-13 J-14 4 PVC 150 False 0 1.43 0.18 0 True 224
P-21 485 J-12 J-15 4 PVC 150 False 0 3 0.37 0.001 True 482
P-22 151 J-15 J-14 4 PVC 150 False 0 -1.28 0.16 0 True 154
P-23 334 T-2 J-16 6 PVC 150 False 0 2.72 0.15 0 True 356
P-24 81 J-16 J-17 4 PVC 150 False 0 1.21 0.15 0 True 86
P-25 313 J-17 J-18 4 PVC 150 False 0 0.53 0.07 0 True 313
P-26 65 J-18 J-19 4 PVC 150 False 0 -0.15 0.02 0 True 65
P-27 305 J-19 J-16 4 PVC 150 False 0 -0.83 0.1 0 True 305
P-37 265 J-1 H-1 4 PVC 150 False 0 13.83 1.71 0.025 True 261
P-38 88 H-1 J-9 4 PVC 150 False 0 13.83 1.71 0.025 True 86
P-41 173 J-5 H-2 4 PVC 150 False 0 6.18 0.76 0.006 True 175
P-42 90 H-2 J-8 4 PVC 150 False 0 6.18 0.76 0.006 True 91
P-43 107 J-12 H-3 4 PVC 150 False 0 -4.89 0.6 0.004 True 108
P-44 207 H-3 J-7 4 PVC 150 False 0 -4.89 0.6 0.004 True 208
P-45 407 J-10 H-4 4 PVC 150 False 0 3.06 0.38 0.002 True 407
P-46 127 H-4 J-13 4 PVC 150 False 0 3.06 0.38 0.002 True 127
P-47 92 J-2 H-5 4 PVC 150 False 0 0.99 0.12 0 True 91
P-48 358 H-5 J-3 4 PVC 150 False 0 0.99 0.12 0 True 354
P-49 368 J-11 H-6 4 PVC 150 False 0 3.03 0.37 0.001 True 364
P-50 105 H-6 J-14 4 PVC 150 False 0 3.03 0.37 0.001 True 104
35
6. ESCENARIO 16
En este escenario se subió la cota del tanque uno de 3037m a 3038m, por tal motivo las
presiones de los nodos J-1 y J-5 cambiaron, aumentando la del nodo J-1 y disminuyendo
la del nodo J-5.
36
6.3. DATOS DE LA TUBERIA
Length Start Stop Diameter Hazen- Has Check Minor Loss Flow Velocity Headloss Has User Length (User
Label (Scalet) (m) Node Node (pulg) Material Williams C Valve Coefficient (lt/seg) (m/seg) Gradient Defined Define) (m)
(local) (m/m) Length
P-1 263 T-1 J-1 6 PVC 150 False 0 38.24 2.1 0.023 True 278
P-2 478 J-1 J-2 6 PVC 150 False 0 5.44 0.3 0.001 True 481
P-4 313 J-3 J-4 6 PVC 150 False 0 -0.93 0.05 0 True 314
P-5 365 J-4 J-2 6 PVC 150 False 0 -3.03 0.17 0 True 370
P-6 231 J-1 J-5 4 PVC 150 False 0 16.77 2.07 0.035 True 228
P-7 97 J-5 J-6 4 PVC 150 False 0 7.65 0.94 0.008 True 90
P-8 272 J-6 J-7 4 PVC 150 False 0 4.76 0.59 0.003 True 268
P-9 91 J-7 J-8 4 PVC 150 False 0 -3.61 0.45 0.002 True 90
P-12 169 J-9 J-8 4 PVC 150 False 0 6.13 0.76 0.005 True 174
P-13 326 J-9 J-10 4 PVC 150 False 0 6.64 0.82 0.006 True 322
P-14 173 J-10 J-11 4 PVC 150 False 0 2.6 0.32 0.001 True 174
P-15 308 J-11 J-8 4 PVC 150 False 0 -5.31 0.65 0.004 True 306
P-16 93 J-11 J-12 4 PVC 150 False 0 1.51 0.19 0 True 94
P-19 224 J-13 J-14 4 PVC 150 False 0 1.43 0.18 0 True 224
P-21 485 J-12 J-15 4 PVC 150 False 0 3 0.37 0.001 True 482
P-22 151 J-15 J-14 4 PVC 150 False 0 -1.28 0.16 0 True 154
P-23 334 T-2 J-16 6 PVC 150 False 0 2.72 0.15 0 True 356
P-24 81 J-16 J-17 4 PVC 150 False 0 1.21 0.15 0 True 86
P-25 313 J-17 J-18 4 PVC 150 False 0 0.53 0.07 0 True 313
P-26 65 J-18 J-19 4 PVC 150 False 0 -0.15 0.02 0 True 65
P-27 305 J-19 J-16 4 PVC 150 False 0 -0.83 0.1 0 True 305
P-37 265 J-1 H-1 4 PVC 150 False 0 13.83 1.71 0.025 True 261
P-38 88 H-1 J-9 4 PVC 150 False 0 13.83 1.71 0.025 True 86
P-41 173 J-5 H-2 4 PVC 150 False 0 6.18 0.76 0.006 True 175
P-42 90 H-2 J-8 4 PVC 150 False 0 6.18 0.76 0.006 True 91
P-43 107 J-12 H-3 4 PVC 150 False 0 -4.89 0.6 0.004 True 108
P-44 207 H-3 J-7 4 PVC 150 False 0 -4.89 0.6 0.004 True 208
P-45 407 J-10 H-4 4 PVC 150 False 0 3.06 0.38 0.002 True 407
P-46 127 H-4 J-13 4 PVC 150 False 0 3.06 0.38 0.002 True 127
P-47 92 J-2 H-5 4 PVC 150 False 0 0.99 0.12 0 True 91
P-48 358 H-5 J-3 4 PVC 150 False 0 0.99 0.12 0 True 354
P-49 368 J-11 H-6 4 PVC 150 False 0 3.03 0.37 0.001 True 364
P-50 105 H-6 J-14 4 PVC 150 False 0 3.03 0.37 0.001 True 104
37
7. ESCENARIO 17
38
7.2. DATOS DE LA TUBERIA
Length Start Stop Diameter Hazen- Has Check Minor Loss Flow Velocity Headloss Has User Length (User
Label (Scalet) (m) Node Node (pulg) Material Williams C Valve Coefficient (lt/seg) (m/seg) Gradient Defined Define) (m)
(local) (m/m) Length
P-1 263 T-1 J-1 6 PVC 150 False 0 37.64 2.06 0.022 True 278
P-2 478 J-1 J-2 6 PVC 150 False 0 5.07 0.28 0.001 True 481
P-4 313 J-3 J-4 6 PVC 150 False 0 -0.98 0.05 0 True 314
P-5 365 J-4 J-2 6 PVC 150 False 0 -2.83 0.16 0 True 370
P-6 231 J-1 J-5 4 PVC 150 False 0 16.67 2.06 0.035 True 228
P-7 97 J-5 J-6 4 PVC 150 False 0 7.58 0.94 0.008 True 90
P-8 272 J-6 J-7 4 PVC 150 False 0 4.69 0.58 0.003 True 268
P-9 91 J-7 J-8 4 PVC 150 False 0 -3.61 0.45 0.002 True 90
P-12 169 J-9 J-8 4 PVC 150 False 0 6.15 0.76 0.005 True 174
P-13 326 J-9 J-10 4 PVC 150 False 0 6.57 0.81 0.006 True 322
P-14 173 J-10 J-11 4 PVC 150 False 0 2.66 0.33 0.001 True 174
P-15 308 J-11 J-8 4 PVC 150 False 0 -5.23 0.65 0.004 True 306
P-16 93 J-11 J-12 4 PVC 150 False 0 1.55 0.19 0 True 94
P-19 224 J-13 J-14 4 PVC 150 False 0 1.52 0.19 0 True 224
P-21 485 J-12 J-15 4 PVC 150 False 0 2.96 0.36 0.001 True 482
P-22 151 J-15 J-14 4 PVC 150 False 0 -1.32 0.16 0 True 154
P-23 334 T-2 J-16 6 PVC 150 False 0 2.72 0.15 0 True 356
P-24 81 J-16 J-17 4 PVC 150 False 0 1.21 0.15 0 True 86
P-25 313 J-17 J-18 4 PVC 150 False 0 0.53 0.07 0 True 313
P-26 65 J-18 J-19 4 PVC 150 False 0 -0.15 0.02 0 True 65
P-27 305 J-19 J-16 4 PVC 150 False 0 -0.83 0.1 0 True 305
P-37 265 J-1 H-1 4 PVC 150 False 0 13.72 1.69 0.024 True 261
P-38 88 H-1 J-9 4 PVC 150 False 0 13.72 1.69 0.024 True 86
P-41 173 J-5 H-2 4 PVC 150 False 0 6.09 0.75 0.005 True 175
P-42 90 H-2 J-8 4 PVC 150 False 0 6.09 0.75 0.005 True 91
P-43 107 J-12 H-3 4 PVC 150 False 0 -4.81 0.59 0.003 True 108
P-44 207 H-3 J-7 4 PVC 150 False 0 -4.81 0.59 0.003 True 208
P-45 407 J-10 H-4 4 PVC 150 False 0 3.02 0.37 0.001 True 407
P-46 127 H-4 J-13 4 PVC 150 False 0 3.02 0.37 0.001 True 127
P-47 92 J-2 H-5 4 PVC 150 False 0 0.94 0.12 0 True 91
P-48 358 H-5 J-3 4 PVC 150 False 0 0.94 0.12 0 True 354
P-49 368 J-11 H-6 4 PVC 150 False 0 2.99 0.37 0.001 True 364
P-50 105 H-6 J-14 4 PVC 150 False 0 2.99 0.37 0.001 True 104
39
8. ESCENARIO 18
40
8.2. DATOS DE LA TUBERIA
Length Start Stop Diameter Hazen- Has Check Minor Loss Flow Velocity Headloss Has User Length (User
Label (Scalet) (m) Node Node (pulg) Material Williams C Valve Coefficient (lt/seg) (m/seg) Gradient Defined Define) (m)
(local) (m/m) Length
P-1 263 T-1 J-1 6 PVC 150 False 0 38.68 2.12 0.023 True 278
P-2 478 J-1 J-2 6 PVC 150 False 0 5.07 0.28 0.001 True 481
P-4 313 J-3 J-4 6 PVC 150 False 0 -0.98 0.05 0 True 314
P-5 365 J-4 J-2 6 PVC 150 False 0 -2.83 0.16 0 True 370
P-6 231 J-1 J-5 4 PVC 150 False 0 17.32 2.14 0.037 True 228
P-7 97 J-5 J-6 4 PVC 150 False 0 7.5 0.93 0.008 True 90
P-8 272 J-6 J-7 4 PVC 150 False 0 4.55 0.56 0.003 True 268
P-9 91 J-7 J-8 4 PVC 150 False 0 -3.72 0.46 0.002 True 90
P-12 169 J-9 J-8 4 PVC 150 False 0 6.41 0.79 0.006 True 174
P-13 326 J-9 J-10 4 PVC 150 False 0 6.68 0.82 0.006 True 322
P-14 173 J-10 J-11 4 PVC 150 False 0 2.73 0.34 0.001 True 174
P-15 308 J-11 J-8 4 PVC 150 False 0 -5.22 0.64 0.004 True 306
P-16 93 J-11 J-12 4 PVC 150 False 0 1.6 0.2 0 True 94
P-19 224 J-13 J-14 4 PVC 150 False 0 1.55 0.19 0 True 224
P-21 485 J-12 J-15 4 PVC 150 False 0 2.98 0.37 0.001 True 482
P-22 151 J-15 J-14 4 PVC 150 False 0 -1.37 0.17 0 True 154
P-23 334 T-2 J-16 6 PVC 150 False 0 2.72 0.15 0 True 356
P-24 81 J-16 J-17 4 PVC 150 False 0 1.21 0.15 0 True 86
P-25 313 J-17 J-18 4 PVC 150 False 0 0.53 0.07 0 True 313
P-26 65 J-18 J-19 4 PVC 150 False 0 -0.15 0.02 0 True 65
P-27 305 J-19 J-16 4 PVC 150 False 0 -0.83 0.1 0 True 305
P-37 265 J-1 H-1 4 PVC 150 False 0 14.09 1.74 0.026 True 261
P-38 88 H-1 J-9 4 PVC 150 False 0 14.09 1.74 0.026 True 86
P-41 173 J-5 H-2 4 PVC 150 False 0 5.92 0.73 0.005 True 175
P-42 90 H-2 J-8 4 PVC 150 False 0 5.92 0.73 0.005 True 91
P-43 107 J-12 H-3 4 PVC 150 False 0 -4.78 0.59 0.003 True 108
P-44 207 H-3 J-7 4 PVC 150 False 0 -4.78 0.59 0.003 True 208
P-45 407 J-10 H-4 4 PVC 150 False 0 3.05 0.38 0.001 True 407
P-46 127 H-4 J-13 4 PVC 150 False 0 3.05 0.38 0.001 True 127
P-47 92 J-2 H-5 4 PVC 150 False 0 0.94 0.12 0 True 91
P-48 358 H-5 J-3 4 PVC 150 False 0 0.94 0.12 0 True 354
P-49 368 J-11 H-6 4 PVC 150 False 0 3 0.37 0.001 True 364
P-50 105 H-6 J-14 4 PVC 150 False 0 3 0.37 0.001 True 104
41
9. ESCENARIO 19
42
9.3. DATOS DE LA TUBERIA
Length Start Stop Diameter Hazen- Has Check Minor Loss Flow Velocity Headloss Has User Length (User
Label (Scalet) (m) Node Node (pulg) Material Williams C Valve Coefficient (lt/seg) (m/seg) Gradient Defined Define) (m)
(local) (m/m) Length
P-1 263 T-1 J-1 6 PVC 150 False 0 38.68 2.12 0.023 True 278
P-2 478 J-1 J-2 6 PVC 150 False 0 5.07 0.28 0.001 True 481
P-4 313 J-3 J-4 6 PVC 150 False 0 -0.98 0.05 0 True 314
P-5 365 J-4 J-2 6 PVC 150 False 0 -2.83 0.16 0 True 370
P-6 231 J-1 J-5 4 PVC 150 False 0 17.32 2.14 0.037 True 228
P-7 97 J-5 J-6 4 PVC 150 False 0 7.5 0.93 0.008 True 90
P-8 272 J-6 J-7 4 PVC 150 False 0 4.55 0.56 0.003 True 268
P-9 91 J-7 J-8 4 PVC 150 False 0 -3.72 0.46 0.002 True 90
P-12 169 J-9 J-8 4 PVC 150 False 0 6.41 0.79 0.006 True 174
P-13 326 J-9 J-10 4 PVC 150 False 0 6.68 0.82 0.006 True 322
P-14 173 J-10 J-11 4 PVC 150 False 0 2.73 0.34 0.001 True 174
P-15 308 J-11 J-8 4 PVC 150 False 0 -5.22 0.64 0.004 True 306
P-16 93 J-11 J-12 4 PVC 150 False 0 1.6 0.2 0 True 94
P-19 224 J-13 J-14 4 PVC 150 False 0 1.55 0.19 0 True 224
P-21 485 J-12 J-15 4 PVC 150 False 0 2.98 0.37 0.001 True 482
P-22 151 J-15 J-14 4 PVC 150 False 0 -1.37 0.17 0 True 154
P-23 334 T-2 J-16 6 PVC 150 False 0 2.72 0.15 0 True 356
P-24 81 J-16 J-17 4 PVC 150 False 0 1.21 0.15 0 True 86
P-25 313 J-17 J-18 4 PVC 150 False 0 0.53 0.07 0 True 313
P-26 65 J-18 J-19 4 PVC 150 False 0 -0.15 0.02 0 True 65
P-27 305 J-19 J-16 4 PVC 150 False 0 -0.83 0.1 0 True 305
P-37 265 J-1 H-1 4 PVC 150 False 0 14.09 1.74 0.026 True 261
P-38 88 H-1 J-9 4 PVC 150 False 0 14.09 1.74 0.026 True 86
P-41 173 J-5 H-2 4 PVC 150 False 0 5.92 0.73 0.005 True 175
P-42 90 H-2 J-8 4 PVC 150 False 0 5.92 0.73 0.005 True 91
P-43 107 J-12 H-3 4 PVC 150 False 0 -4.78 0.59 0.003 True 108
P-44 207 H-3 J-7 4 PVC 150 False 0 -4.78 0.59 0.003 True 208
P-45 407 J-10 H-4 4 PVC 150 False 0 3.05 0.38 0.001 True 407
P-46 127 H-4 J-13 4 PVC 150 False 0 3.05 0.38 0.001 True 127
P-47 92 J-2 H-5 4 PVC 150 False 0 0.94 0.12 0 True 91
P-48 358 H-5 J-3 4 PVC 150 False 0 0.94 0.12 0 True 354
P-49 368 J-11 H-6 4 PVC 150 False 0 3 0.37 0.001 True 364
P-50 105 H-6 J-14 4 PVC 150 False 0 3 0.37 0.001 True 104
43
10. ESCENARIO 20
Este es el escenario final en donde las presiones están dentro del rango 10 ≤ 𝑃 ≤ 50.
44
10.2. DATOS DE LA TUBERIA
Length Start Stop Diameter Hazen- Has Check Minor Loss Flow Velocity Headloss Has User Length (User
Label (Scalet) (m) Node Node (pulg) Material Williams C Valve Coefficient (lt/seg) (m/seg) Gradient Defined Define) (m)
(local) (m/m) Length
P-1 263 T-1 J-1 6 PVC 150 False 0 39.77 2.18 0.024 True 278
P-2 478 J-1 J-2 6 PVC 150 False 0 4.85 0.27 0 True 481
P-4 313 J-3 J-4 6 PVC 150 False 0 -0.92 0.05 0 True 314
P-5 365 J-4 J-2 6 PVC 150 False 0 -2.82 0.15 0 True 370
P-6 231 J-1 J-5 4 PVC 150 False 0 18.89 2.33 0.044 True 228
P-7 97 J-5 J-6 4 PVC 150 False 0 8.11 1 0.009 True 90
P-8 272 J-6 J-7 4 PVC 150 False 0 4.81 0.59 0.003 True 268
P-9 91 J-7 J-8 4 PVC 150 False 0 -3.86 0.48 0.002 True 90
P-12 169 J-9 J-8 4 PVC 150 False 0 6.59 0.81 0.006 True 174
P-13 326 J-9 J-10 4 PVC 150 False 0 6.94 0.86 0.007 True 322
P-14 173 J-10 J-11 4 PVC 150 False 0 2.82 0.35 0.001 True 174
P-15 308 J-11 J-8 4 PVC 150 False 0 -5.47 0.67 0.004 True 306
P-16 93 J-11 J-12 4 PVC 150 False 0 1.68 0.21 0 True 94
P-19 224 J-13 J-14 4 PVC 150 False 0 1.66 0.21 0 True 224
P-21 485 J-12 J-15 4 PVC 150 False 0 3.16 0.39 0.002 True 482
P-22 151 J-15 J-14 4 PVC 150 False 0 -1.64 0.2 0 True 154
P-23 334 T-2 J-16 6 PVC 150 False 0 2.72 0.15 0 True 356
P-24 81 J-16 J-17 4 PVC 150 False 0 1.21 0.15 0 True 86
P-25 313 J-17 J-18 4 PVC 150 False 0 0.53 0.07 0 True 313
P-26 65 J-18 J-19 4 PVC 150 False 0 -0.15 0.02 0 True 65
P-27 305 J-19 J-16 4 PVC 150 False 0 -0.83 0.1 0 True 305
P-37 265 J-1 H-1 4 PVC 150 False 0 15.43 1.9 0.03 True 261
P-38 88 H-1 J-9 4 PVC 150 False 0 15.43 1.9 0.03 True 86
P-41 173 J-5 H-2 4 PVC 150 False 0 6.35 0.78 0.006 True 175
P-42 90 H-2 J-8 4 PVC 150 False 0 6.35 0.78 0.006 True 91
P-43 107 J-12 H-3 4 PVC 150 False 0 -5.02 0.62 0.004 True 108
P-44 207 H-3 J-7 4 PVC 150 False 0 -5.02 0.62 0.004 True 208
P-45 407 J-10 H-4 4 PVC 150 False 0 3.17 0.39 0.002 True 407
P-46 127 H-4 J-13 4 PVC 150 False 0 3.17 0.39 0.002 True 127
P-47 92 J-2 H-5 4 PVC 150 False 0 0.93 0.11 0 True 91
P-48 358 H-5 J-3 4 PVC 150 False 0 0.93 0.11 0 True 354
P-49 368 J-11 H-6 4 PVC 150 False 0 3.15 0.39 0.002 True 364
P-50 105 H-6 J-14 4 PVC 150 False 0 3.15 0.39 0.002 True 104
45
11.0 CONCLUSIONES
En algunos escenarios se tuvo que variar la cota de los tanques (sobre todo del
tanque uno (TANK-1)) ya que las presiones en algunos nodos no cumplían con
el intervalo establecido en la norma del R.N.E.
El nodo uno (J-1) fue el más difícil de realizarlo ya que este presenta la mayor
cota respecto a los demás nodos y esto hace que sus presiones varíen en rangos
mayores a las demás.
46