Está en la página 1de 15

metodo de las 4 poblaciones (las 2 mas antiguas y las 2 mas modernas)

m m 1
P Pn mP 2P
2

ao al cual se va a proyectar 2030

AO POBLACION INCREMENTO DE LA
POBLACION (P)
INCREMENTO DEL
INCREMENTO (2P)

1 1915 106394
2 1925 115066 8672 m= 2.5
3 1935 122137 7071 -1601
4 1945 126711 4574 -2497
5 1955 136275 9564 4990
6 1965 145378 9103 -461
7 1975 150512 5134 -3969
8 1985 157047 6535 1401
9 1995 166262 9215 2680
10 2005 174145 7883 -1332
SUMA = 67751 -789

P 7,527.8889
P -98.6250
2

Pt = 192,779.800
METODODE LOSMINIMOS CUADRADOS
Este metodo se basa e censos equidistantes en el tiempo a traves de la metodologia que se presenta acontinuacion

Y1 X i 1 X i / X i DONDE:
Y1 = razon de cresimiento
Xi = poblacion
CRECIMIENTO ARITMETICO
Los valores de XI e Yi varian linealmente Y i a bX i

Donde:
X Y
a b 0
n n

X X XY
2

a b 0
n n n

CRECIMIENTO GEOMETRICO
Los valores de Xi e Yi varian EXPONENCIALMENTE segn :
bX
Y i ae
Y A BX
Donde: X LogY
A B 0
n n

X XLogY
2

A B 0
X X

a 10 A
B
b
Loge

POBLACION RAZON DE
AO CRESIMECENTO Yi LogYi Xi^2 XiYi XiLogYi
Xi (%)

1 1915 106394 8.15 0.9112 1.13E+10 867,200.00 96,946.44


2 1925 115066 6.15 0.7885 1.32E+10 707,100.00 90,733.43
3 1935 122137 3.74 0.5734 1.49E+10 457,400.00 70,039.33
4 1945 126711 7.55 0.8778 1.61E+10 956,400.00 111,230.12
5 1955 136275 6.68 0.8248 1.86E+10 910,300.00 112,395.31
6 1965 145378 3.53 0.5480 2.11E+10 513,400.00 79,660.92
7 1975 150512 4.34 0.6377 2.27E+10 653,500.00 95,977.66
8 1985 157047 5.87 0.7685 2.47E+10 921,500.00 120,685.23
9 1995 166262 4.74 0.6759 2.76E+10 788,300.00 112,376.24
10 2005 174145
1,056,330 32.71 4.3326 1.31E+11 4,743,400.00 632,325.47
Promedio 105,633 3.63 0.4814 1.45E+10 527,044.44 70,258.39
123,751.09 0.60
segn cresimiento aritmetico Y a bX
i i

a= -1.73460666
b= 5.27E-05

Yi=-1.7346+0.00005267Xi Yi = 7.44E+00 crecimiento = 12954.77294

segn el cresimiento geometrico

A 0.0194

B 5.10E-06

a 1.05
b 1.18E-05

Yi = 1.05e^(11.8*Xi)

INCREMENTO
AOS DESPUES POBLACION CRECIMIENTO POR DECADA % POR DECADA
DEL ULTIMO CENSO
ARITMETICO GEOMETRICO ARITMETICO GEOMETRICO ARITMETICO
0 174,145 174,145 7.44 8.10 12,955
10 187,100 188,247 8.12 9.56 15,195
20 202,295 206,240 8.92 11.81 18,049
30 220,344 230,596

Aritmetico
P2030 211,319 hab
Geometrico
P2030 218,418 hab
senta acontinuacion

11106895236
7.44E+00

X Y
a b 0
n n

X X XY
2

a b 0
n n n

INCREMENTO
POR DECADA
GEOMETRICO
14,102
17,993
24,355
PROBLEMA NUMERO 3

Para la informacin mostrada se pide osto disear la lnea de conduccin ms econmica, sabiendo que el Costo de una C

SOLUCION

A) Considerando una camara reductora de presion

CAMARA DE CAPTACION
COTA (m.s.n.m) COTA: 3358.86
TERRENO
3558.86

67.2766666667

67.2766666667 LGH
67.2766666667

67.2766666667
67.2766666667
67.2766666667

= 3 pulg.

1500

CALCULO DEL DIAMETRO DE LA TUBERIA

Z= 403.6 m
L 1500 m
Q= 26.5625 Lt/s
C= 150
S= 269.0666666667 m/Km
D= 3.1111381817 pulg
D COLOCADO= 3 pulg

CALCULO DE PERDIDAS

Hf= 570.087444936
do que el Costo de una CRP es de $500.00 y el costo por ML de tubera es: C.7-5 = $5.00 ml y C.10 = $8.00 para dimetros de hasta 6" en a

COTA: 0.00
PIEZOMETRICA

0.00

COTA: 3155.2
TERRENO
0 para dimetros de hasta 6" en ambos casos.
4) En una localidad ubicada en la sierra peruana se tiene una poblacin proyect
101000 habitantes; para el diseo de las estructuras de almacenamiento se cuent
consumo horario mostrada. Se pide:
a. Dimensionar el deposito de almacenamiento superficial.
b. Dimesionar el tanque elevado y tanque de succion.

Suministro por gravedad (SUM-GRAV)


HORA C(%) C(%) S(%) S(%) (S-C)
1 2 3 4 5 6
0 1 1 1 4.167 4.17 3.17
1 2 1 2 4.167 8.33 3.17
2 3 1 3 4.167 12.50 3.17
3 4 1 4 4.167 16.67 3.17
4 5 3 7 4.167 20.83 1.17
5 6 4 11 4.167 25.00 0.17
6 7 8.5 19.5 4.167 29.17 -4.33
7 8 9 28.5 4.167 33.33 -4.83
8 9 7 35.5 4.167 37.50 -2.83
9 10 4 39.5 4.167 41.67 0.17
10 11 3 42.5 4.167 45.83 1.17
11 12 5.5 48 4.167 50.00 -1.33
12 13 8 56 4.167 54.17 -3.83
13 14 5 61 4.167 58.33 -0.83
14 15 3 64 4.167 62.50 1.17
15 16 2.5 66.5 4.167 66.67 1.67
16 17 3 69.5 4.167 70.83 1.17
17 18 3.5 73 4.167 75.00 0.67
18 19 6 79 4.167 79.17 -1.83
19 20 8 87 4.167 83.33 -3.83
20 21 8.5 95.5 4.167 87.50 -4.33
21 22 2 97.5 4.167 91.67 2.17
22 23 1.5 99 4.167 95.83 2.67
23 24 1 100 4.167 100.00 3.17

Suministro por bombeo (TANQ-SUC-SUM-GRAV)


HORA C(%) C(%) S(%) S(%) (S-C)
1 2 3 4 5 6
0 1 0.000 0 4.167 4.17 4.17
1 2 0.000 0 4.167 8.33 4.17
2 3 0.000 0 4.167 12.50 4.17
3 4 0.000 0 4.167 16.67 4.17
4 5 0.000 0 4.167 20.83 4.17
5 6 0.000 0 4.167 25.00 4.17
6 7 12.500 12.5 4.167 29.17 -8.33
7 8 12.500 25 4.167 33.33 -8.33
8 9 12.500 37.5 4.167 37.50 -8.33
9 10 0.000 37.5 4.167 41.67 4.17
10 11 0.000 37.5 4.167 45.83 4.17
11 12 0.000 37.5 4.167 50.00 4.17
12 13 0.000 37.5 4.167 54.17 4.17
13 14 0.000 37.5 4.167 58.33 4.17
14 15 0.000 37.5 4.167 62.50 4.17
15 16 0.000 37.5 4.167 66.67 4.17
16 17 12.500 50 4.167 70.83 -8.33
17 18 12.500 62.5 4.167 75.00 -8.33
18 19 12.500 75 4.167 79.17 -8.33
19 20 12.500 87.5 4.167 83.33 -8.33
20 21 12.500 100 4.167 87.50 -8.33
21 22 0.000 100 4.167 91.67 4.17
22 23 0.000 100 4.167 95.83 4.17
23 24 0.000 100 4.167 100.00 4.17
tiene una poblacin proyectada para el 2030 de
de almacenamiento se cuenta con la variacin de
ostrada. Se pide:
a. Suministro por gravedad a un tanque superficial
b. Suministro por bombeo a un tanque elevado durante 06 horas, desde las 6:00am hasta las 9.am y desde las 16

Suministro por bombeo (TANQ-ELEV-SUM-BOM)


(S-C) HORA C(%) C(%) S(%)
7 1 2 3 4
3.17 0 1 1 1 0.000
6.33 1 2 1 2 0.000
9.50 2 3 1 3 0.000
12.67 3 4 1 4 0.000
13.83 4 5 3 7 0.000
14.00 5 6 4 11 0.000
9.67 6 7 8.5 19.5 12.500
4.83 7 8 9 28.5 12.500
2.00 8 9 7 35.5 12.500
2.17 9 10 4 39.5 0.000
3.33 10 11 3 42.5 0.000
2.00 11 12 5.5 48 0.000
-1.83 12 13 8 56 0.000
-2.67 13 14 5 61 0.000
-1.50 14 15 3 64 0.000
0.17 15 16 2.5 66.5 0.000
1.33 16 17 3 69.5 12.500
2.00 17 18 3.5 73 12.500
0.17 18 19 6 79 12.500
-3.67 19 20 8 87 12.500
-8.00 20 21 8.5 95.5 12.500
-5.83 21 22 2 97.5 0.000
-3.17 22 23 1.5 99 0.000
0.00 23 24 1 100 0.000

(S-C) Volumen del tanque


7
4.17 A. VOLUMEN POR CONSUMO DOMESTICO
8.33 Caudal maximo diario = 233.796296 ltrs/seg
12.50 1.- TANQUE SUPERFICIAL
16.67 % consumo medio diario = 22.00
20.83 Volumen del tanque = 6666
25.00 2.- BOMBEO TANQUE ELEVADO
16.67 % consumo medio diario = 33.50
8.33 Volumen del tanque = 10150.5
0.00 3.- BOMBEO TANQUE DE SUCCION:
4.17 % consumo medio diario = 41.67
8.33 Volumen del tanque = 12625
12.50 B.- VOLUMEN PARA INCENDIOS:
16.67 Por enunciado se considera:
20.83 Numero de hidrantes = 5
25.00 Caudal de hidrante = 16
29.17 Tiempo de funcionamiento = 2
20.83
12.50 Volumen para incendios = 576
4.17 C.- VOLUMEN DE EMERGENCIA:
-4.17 % considerado = 25
-12.50 1.- Tanque superficial:
-8.33 Volumen = 1810.5
-4.17
0.00 2.- Tanque elevado:
Volumen = 2681.625
C.- VOLUMEN DEL TANQUE TOTAL:
1.- Tanque superficial:
Volumen = 9052.5

2.- Tanque elevado:


Volumen = 13408.125

3.- Tanque de succion:


Volumen = 12625
am hasta las 9.am y desde las 16.00 hasta las 21 horas.

ANQ-ELEV-SUM-BOM)

S(%) (S-C) (S-C)


5 6 7
0.00 -1.00 -1.00
0.00 -1.00 -2.00
0.00 -1.00 -3.00
0.00 -1.00 -4.00
0.00 -3.00 -7.00
0.00 -4.00 -11.00
12.50 4.00 -7.00
25.00 3.50 -3.50
37.50 5.50 2.00
37.50 -4.00 -2.00
37.50 -3.00 -5.00
37.50 -5.50 -10.50
37.50 -8.00 -18.50
37.50 -5.00 -23.50
37.50 -3.00 -26.50
37.50 -2.50 -29.00
50.00 9.50 -19.50
62.50 9.00 -10.50
75.00 6.50 -4.00
87.50 4.50 0.50
100.00 4.00 4.50
100.00 -2.00 2.50
100.00 -1.50 1.00
100.00 -1.00 0.00

el tanque

0.2337963 ltrs/seg 30300 m3/dia


%
m3

%
m3

%
m3

ltrs/seg
Hrs

m3

m3

m3

m3

m3

m3

También podría gustarte