Está en la página 1de 29

LABORATORIO DE HIDRULICA DE CANALES

INFORME DE PRACTICA N1
ALUMNO: MARIO UZURIAGA EGOAVIL
CODIGO: 20122405 HORARIO

TEMA: FLUJO PERMANENTE Y UNIFORME EN CANALES


FLUJO GRADUALMENTE VARIADO (PERFILES)
FLUJO RAPIDAMENTE VARIADO (RESALTO HIDRULICO)

JEFE DE PRACTICA: ING. G. MOTERO

FECHA DE REALIZACION: 12/04/17

CALIFICACION:

ITEM PUNTOS
PRUEBA DE
ENTRADA
TRABAJO Y
PARTICIPACION
INFORME DE
LABORATORIO
NOTA DE
LABORATORIO

FIRMA DE JEFE DE PRACTICA:


Tabla de contenido
1 INTRODUCCION..................................................................................................1
1.1 OBJETIVOS................................................................................................................1
1.1.1 FLUJO PERMANENTE Y UNIFORME EN CANALES.....................................................................1
1.1.2 FLUJO GRADUALMENTE VARIADO (PERFILES).........................................................................1
1.1.3 FLUJO RAPIDAMENTE VARIADO (RESALTO HIDRULICO)........................................................1

1.2 APLICACIONES PRCTICAS EN LA INGENIERA..........................................................2


1.2.1 FLUJO PERMANENTE Y UNIFORME EN CANALES.....................................................................2
1.2.2 FLUJO GRADUALMENTE VARIADO (PERFILES).........................................................................2
1.2.3 FLUJO RAPIDAMENTE VARIADO (RESALTO HIDRULICO)........................................................2

2 METODOLOGA DE DATOS...................................................................................2
2.1 FUNDAMENTOS TERICOS.......................................................................................2
2.1.1 FLUJO PERMANENTE Y UNIFORME EN CANALES.....................................................................2
2.1.2 FLUJO GRADUALMENTE VARIADO (PERFILES).........................................................................2
2.1.3 FLUJO RAPIDAMENTE VARIADO (RESALTO HIDRULICO)........................................................2

2.2 PROCEDIMIENTO......................................................................................................2
2.3 DESCRIPCIN DE LOS DATOS Y RESOLUCIN DE LOS DATO.......................................2
3 RESULTADOS Y DISCUSION DE RESULTADOS.........................................................1
3.1 RESULTADOS.............................................................................................................1
3.1.1 FLUJO PERMANENTE Y UNIFORME EN CANALES.....................................................................1
3.1.1 FLUJO GRADUALMENTE VARIADO (PERFILES).........................................................................5
3.1.2 FLUJO GRADUALMENTE VARIADO (PERFILES).........................................................................3
3.1.3 FLUJO RAPIDAMENTE VARIADO (RESALTO HIDRULICO)........................................................3

3.2 DISCUSIN DE RESULTADOS.....................................................................................3


4 CONCLUSIONES Y RECOMENDACIONES................................................................3
5 BIBLIOGRAFA.....................................................................................................3
LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

1 INTRODUCCION

1.1 OBJETIVOS

1.1.1 FLUJO PERMANENTE Y UNIFORME EN CANALES

Se debe en este experimento analizar y determinar


mediante un flujo permanente y uniforme las
expresiones de Manning, Chezy y Darcy-Weisbach.

Se debe determinar la pendiente de energa de un canal


idealmente uniforme a travs de la medicin de sus
respectivos caudales y tirantes.

1.1.2 FLUJO GRADUALMENTE VARIADO (PERFILES)

En este experimento se debe calcular y analizar el perfil


del flujo mediante el mtodo directo tramo a tramo. Este
flujo es de tipo gradualmente variado por ello cambia las
caractersticas del canal y por ende el tirante tambin
vara.

1.1.3 FLUJO RAPIDAMENTE VARIADO (RESALTO HIDRULICO)

En este experimento se debe analizar el flujo


rpidamente variado a travs del fenmeno local llamado
resalto hidrulico causado por el cambio brusco de las
caractersticas del canal.

Adems, al resalto hidrulico se buscar catalogarlo por


medio del nmero de Froude.

MARIO UZURIAGA 1
LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

2 METODOLOGA DE DATOS

2.1 FUNDAMENTOS TERICOS

2.1.1 FLUJO PERMANENTE Y UNIFORME EN CANALES

El flujo permanente y uniforme se presenta cuando las fuerzas


motivadoras y resistentes se equilibran. Cuando se dice que es
permanente se refiere que las caractersticas del flujo (velocidad,
tirante, etc) en una seccin de un canal no varan con el tiempo.
El ser uniforme se refiere a la condicin donde las caractersticas
como la velocidad, pendiente y tirante permanecen constantes a
lo largo del canal.
Este flujo tambin se caracteriza por el hecho de que la lnea de
energa es paralela a la superficie libre de lquido (altura
piezomtrica) y al fondo del canal. En la prctica es imposible
encontrar un flujo que sea estrictamente uniforme, ya que es
imposible obviar el efecto de la friccin que cambia
constantemente las caractersticas del flujo. Los ingenieros
consideran ros y canales como flujos uniformes cuando la
pendiente no es muy grande.

Existen diversas frmulas para analizar el flujo permanente y


uniforme en canales, entre las que se tiene:
2 1
3 2
Frmula de Manning: V = R S
n
Frmula de Chezy: V =C RS
Frmula de Darcy-Weisbach:

V = 32 gRS . log
[ k
+
1.255
14.8 R R 32 gRS ]

MARIO UZURIAGA 2
LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

2.1.2 FLUJO GRADUALMENTE VARIADO (PERFILES)

El flujo gradualmente variado se presenta cuando las fuerzas


motivadoras y las fuerzas resistentes no se equilibran. El
resultado es una variacin gradual del tirante a lo largo del canal.
Esta variacin gradual garantiza que las lneas de corriente sean
prcticamente paralelas y que por tanto, la distribucin
hidrosttica de presiones prevalezca en cualquier seccin del
canal.
Las teoras desarrolladas para el anlisis del flujo gradualmente
variado se basan en varias hiptesis, entre las que se distinguen
las siguientes:
La pendiente del canal es pequea.
Las ecuaciones del flujo uniforme pueden ser usadas para
determinar la pendiente de la lnea de energa en cualquier
seccin del canal.
El coeficiente de rugosidad, desarrollado fundamentalmente para
flujo uniforme, es aplicable al caso de flujo gradualmente
variado.
La ecuacin fundamentalmente del flujo gradualmente variado
establece que:
dy S 0S f
=
dx 1F r 2
Donde:
x = posicin de la seccin en estudio
y = tirante de agua
S0 = pendiente del fondo del canal
Sf = pendiente de la lnea de energa:
2 2
V n V2
Sf = 4 (Segn Manning), Sf = (Segn Chezy)
R 3 C2 R
Q2 B
Fr = 3 (Nmero de Froude)
gA
Para el clculo de perfiles se disponen de los siguientes
mtodos:
Mtodo de integracin grfica o numrica.
Mtodo de integracin directa.
Mtodos tramo a tramo
Para esta experiencia se us el mtodo de tramo a tramo, el cual
se puede aplicar a canales prismticos como el da la
experiencia. De acuerdo a este mtodo se considera un tramo
genrico (1) (2) que se expresa:
E2E 1
dx=
S0S f
Donde:

MARIO UZURIAGA 3
LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

dx = distancia entre secciones


V2
E = energa especifica = y +
2g
S0 = pendiente del fondo del canal (S0 = 0 en la
presente experiencia)
Sf = pendiente promedio de la lnea de energa en el
tramo:
Sf + Sf
Sf = 1 2

2.1.3 FLUJO RAPIDAMENTE VARIADO (RESALTO HIDRULICO)

En este tipo de flujo la curvatura del perfil del agua es tan grande
que ya no se puede suponer distribucin hidrosttica de
presiones. Existe gran prdida de energa que, al ser un tramo
corto, no puede suponerse que se debe a la friccin. Existen dos
tipos de perfiles: continuos, en vertederos y compuertas, y
discontinuos en el resalto hidrulico.
Si el rgimen aguas debajo de la compuerta pasa a ser
subcrtico se produce un fenmeno conocido como resalto
hidrulico. Consiste en una brusca disminucin de la velocidad
acompaado de una brusca elevacin de la superficie libre. El
flujo de agua convierte su energa cintica en energa potencial y
trmica. En la superficie inclinada del resalto se forma un rodillo
que arrastra aire y lo introduce dentro del lquido. Esta superficie
es muy irregular y turbulenta, mayor es la prdida de energa
cuanto mayor es la diferencia de los tirantes antes y despus del
resalto.
Es una buena manera de disipar energa.

Sea el ancho B, se tiene:

Por Bernoulli:

MARIO UZURIAGA 4
LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

De ambas ecuaciones se tiene:

Se define el coeficiente de Descarga como:

El caudal real queda definido como:


La relacin entre los parmetros que conforman el resalto:

Donde:

Prdida de energa:
Ecuacin de cantidad de movimiento:

2.2 PROCEDIMIENTO

2.2.1 FLUJO PERMANENTE Y UNIFORME EN CANALES

Se asegur que la compuerta al final del canal este


completamente abierta.

Se enciende la bomba y se grada la vlvula para


caudales de 24, 35 y 45 l/s.

Con cada diferente caudal se mide con los limnmetros el


tirantes para 1.5 y 7.5 m de donde fluye el canal.

2.2.2 FLUJO GRADUALMENTE VARIADO (PERFILES)

Se asegur que la compuerta al final del canal este


completamente abierta.

Se enciende la bomba y se grada la vlvula para


caudales de 24, 35 y 45 l/s.

MARIO UZURIAGA 5
LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

Con cada diferente caudal se mide con los limnmetros


los tirantes para 1.5, 3, 4.5 y 7.5 m de donde fluye el
canal.

2.2.3 FLUJO RAPIDAMENTE CARIADO (RESALTO HIDRULICO)

Se instal la compuerta y se midi la abertura.


Se abri completamente la compuerta situada al final del
canal se estableci un caudal abriendo la vlvula.
Luego se levant gradualmente la compuerta situada al
final del canal para producir un remanso de agua que
luego se estableci.
Se midi los tirantes h1 antes y h2 despus de la
compuerta (en la seccin contrada) y tambin los tirantes
conjugados y1 e y2 del resalto producido.
Se midi aproximadamente la longitud del resalto.
Finalmente se hizo otra prueba con otro caudal y otra
abertura.

MARIO UZURIAGA 6
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

3 RESULTADOS Y DISCUSION DE RESULTADOS

3.1 RESULTADOS

3.1.1 FLUJO PERMANENTE Y UNIFORME EN CANALES

EL LIMNMETRO SE ENCONTRABA INVERTIDO

SECCIN 1 (x=1.5 m) Y1 SECCIN 4 (x=7.5 m) Y4


l COTA COTA
Q( ) COTA SUPERIOR COTA SUPERIOR
s INFERIOR INFERIOR
(SUPERFICIE=YS) (SUPERFICIE=YS)
(FONDO=YF) (FONDO=YF)
24 50.92 cm. 40.15 cm. 0.73 cm. 9.46 cm.

35 50.92 cm. 37.77 cm. 0.73 cm. 11.36 cm.

45 50.92 cm. 35.74 cm. 0.73 cm. 13.13 cm.

Y 1=50.9240.15 Y 1=10.77 cm.

24 l/s cm .
Y 4 =9.460.73 Y 4=8.73

MARIO UZURIAGA 7
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

Y 1=50.9237.77 Y 1=13.15 cm .
35 l/s
Y 4 =11.360.73 Y 4=10.63 cm .

Y 1=50.9235.74 Y 1=15.18
45 l/s cm .

Y 4 =13.130.73 Y 4 =12.4 cm.

TIRANTE
Q (m3/s)
Y1 (cm.) Y4 (cm.)
0.024 10.77 8.73

0.035 13.15 10.63

0.045 15.18 12.40

Q
Hallando la velocidad media: Q= A V m V m=
A
Para hallar el rea se sabe que el ancho del canal es: 0.4 m y se sabe el tirante por ello se calcula el rea de la
siguiente manera: A=0.4 Y (m)

3 3 3
m m m
Q=0.024 ( ) Q=0.035 ( ) Q=0.045 ( )
s s s
0.024 m 0.035 m 0.045 m
V 1= =0.5571 V 1= =0.6654 V 1= =0.7411
( 0.4 0.1077 ) s ( 0.4 0.1315 ) s ( 0.4 0.1518 ) s
0.024 m 0.035 m 0.045 m
V 4= =0.6872 V 4= =0.8231 V 4= =0.9073
( 0.4 0.0873 ) s ( 0.4 0.1063 ) s ( 0.4 0.1240 ) s

MARIO UZURIAGA 8
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

3
m 3
Q=0.024 ( ) m
s m3 Q=0.045 ( )
Q=0.035 ( ) s
V prom= 0.62215 m/s. s
V prom=0.8242 m/s.
V prom= 0.7443 m/s.

Calculo de la energa de las secciones en Y1 y Y2 con la siguiente frmula:


v2
E= +Y
2g

m
DATOS: g=9.81
s2

3
m m3 m
3
Q=0.024 ( ) Q=0.035 ( ) Q=0.045 ( )
s s s
0.55712 0.6654 2 0.74112
E 1= + 0.1077=0.1235m E 1= + 0.1315=0.1541 m E 1= + 0.1518=0.1798 m
( 2 9.81 ) ( 2 9.81 ) ( 2 9.81 )
0.68722 0.82312 0.9073
2
E 1= + 0.0873=0.1113 m E4 = +0.1063=0.1408 m E1= + 0.1240=0.1659 m
( 2 9.81 ) ( 2 9.81 ) ( 2 9.81 )

m3 Energa (m) Prdida (m)


s ) E1 E4 E=|E1E 4|
Q
0.024 0.1235 0.1113 0.0122
0.035 0.1541 0.1408 0.0133
0.045 0.1798 9 0.1659 0.0139
MARIO UZURIAGA
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

E
Calcular la pendiente media de lnea de energa: S prom= L=7.51.5 L=6 m .
L

m3
m 3
m 3 Q=0.045 ( )
Q=0.024 ( ) Q=0.035 ( ) s
s s
0.0139
0.0122 0.0133 S prom= =0.00231
S prom= =0.00203 S prom= =0.00216 6
6 6

Calculo de los radios hidrulicos:

m3 Rh1 + Rh2 R prom


A Q( ) Rh1(cm.) Rh2(cm)
Rh= m
(m)
A m =40 Y Pm=40+2 Y s 2
Pm
3 0.024 7 6.07 6.54 0.0654
m 3
Q=0.024 ( ) m
s Q=0.035 ( ) 0.035 7.93 6.94
7.44 0.0744
s
40 10.77 8.14 0.0814
R h= =7 cm . 40 13.15 0.045 8.62 7.65
40+ 2 10.77 R h= =7.93 cm.
40+ 2 13.15
40 8.73
Rh= =6.07 cm . 40 10.63
40+ 2 8.73 R h= =6.94 cm .
40+ 2 10.63

m3
Q=0.045 ( )
s
40 15.18
R h= =8.62 cm.
40+ 2 15.18
40 12.40
R h= =7.65 cm
40+ 2 12.40 10
MARIO UZURIAGA
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

V
Calcular el coeficiente de Chezy: C=
(R S)0.5

3
m
m 3
m
3 Q=0.045 ( )
Q=0.024 ( ) Q=0.035 ( ) s
s s
0.8242 m0.5
0.5571 m
0.5
0.7443 m0.5 C= =60.11 ( ).
C= 0.5
=54 ( ). C= =58.71( ). (0.0814 0.00231)0.5 s
(0.0654 0.00203) s (0.0196 0.00216)0.5
s

Hallando el valor de n de Manning: n=Rh2/3*Sprom 0.5/Vprom

m3
m
3
m
3 Q=0.045 ( )
Q=0.024 ( ) Q=0.035 ( ) s
s s
n= 0.01089
2/ 3
(0.0697) 0.002003 0.5 n= 0.0111
n= =0.0122
0.62221

MARIO UZURIAGA 11
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

Hallando el coeficiente n utilizando de Horton Einstein:


Datos: nconcreto=0.014 nvidrio=0.010

Formulas:
n=R2/3*S0.5/V (Manning) n=(pi*ni1.5/P)2/3 (Horton-Einstein)

3
m
Q=0.024 ( )
s m3
3
Q=0.045 ( )
m s
Q=0.035 ( )

[ ]
2 /3
10.77 +8.73 s
20.01( ) 0.0101.5 +0.4 0.0141.5 n=0.0124
2
N= =0.0128 s /m1 /3 n= 0.0126
10.77+ 8.73
20.01 ( 2 )+0.4

Calculo el coeficiente de rugosidad absoluta:

K 1.255 v
V = 32 RS log( + )
14.8 R R 32 g R S

3
m
Q=0.024 ( ) m
3
m
3
s Q=0.035 ( ) Q=0.045 ( )
s s
K= 32 0.0654 0.002 log
K
( +
1.255 106
14.8 0.0654 0.0654 32 g 0.0654 0.002 ) K= 4.913 K= 4.033

K=7.311

MARIO UZURIAGA 12
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

k
C n n
Qr y1 y2 Vprom E Darcy-
Sprom Chezy Manning Horton-Einstein
(lps) (cm) (cm) (m/s) (m) Weisbach
(m^0.5/s) (s/m^1/3) (s/m^1/3)
(m)

24 0.1077 0.0873 0.6222 0.0121 0.0020 54.086 0.0117 0.0128 7.311

35 0.1315 0.1063 0.7443 0.0132 0.0022 58.114 0.0112 0.0126 4.913

45 0.1518 0.1240 0.8242 0.0138 0.0023 60.138 0.0109 0.0124 4.033

EL LIMNMETRO SE ENCONTRABA INVERTIDO

MARIO UZURIAGA 13
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

1.1.1 FLUJO GRADUALMENTE VARIADO (PERFILES)

SECCIN 1 (x=1.5 m) Y1 SECCIN 2 (x=3 m) Y2 SECCIN 3 (x=4.5 m) Y3 SECCIN 4 (x=7.5 m) Y4


l COTA COTA COTA COTA
Q( ) COTA SUPERIOR COTA SUPERIOR COTA SUPERIOR COTA SUPERIOR
s INFERIOR INFERIOR INFERIOR INFERIOR
(SUPERFICIE=YS) (SUPERFICIE=YS) (SUPERFICIE=YS) (SUPERFICIE=YS)
(FONDO=YF) (FONDO=YF) (FONDO=YF) (FONDO=YF)
24 50.92 cm. 40.15 cm. 50.8 cm. 40.51 cm. 0.76 cm. 10.87 cm. 0.73 cm. 9.46 cm.

35 50.92 cm. 37.77 cm. 50.8 cm. 38.14 cm. 0.76 cm. 13.16 cm. 0.73 cm. 11.36 cm.

45 50.92 cm. 35.74 cm. 50.8 cm. 36.21 cm. 0.76 cm. 14.87 cm. 0.73 cm. 13.13 cm.

Calculando el tirante de cada seccin:

cotainferior ( Y F )cota superior ( Y S )=tirante (Y )

Y 1=50.9240.15 Y 1=10.77 cm.

Y 2=50.840.51 Y 2 =10.29 cm.

Y 3=10.870.76 Y 3=10.11 cm .

MARIO UZURIAGA 14
24 l/s
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

Y 4 =9.460.73 Y 4=8.73 cm .

Y 1=50.9237.77 Y 1=13.15 cm .

Y 2=50.838.14 Y 2=12.66 cm.


35 l/s
Y 3=13.160.76 Y 3=12.4 cm .

Y 4 =11.360.73 Y 4=10.63 cm .

45 l/s

TIRANTE
Q (m3/s)
Y1 (cm.) Y2 (cm.) Y3 (cm.) Y4 (cm.)
0.024 10.77 10.29 10.11 8.73

0.035 13.15 12.66 12.4 10.63

0.045 15.18 14.59 14.11 12.4

MARIO UZURIAGA 15
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

Y 1=50.9235.74 Y 1=15.18 cm .

Y 2=50.836.21 Y 2=14.59 cm .

Y 3=14.870.76 Y 3=14.11 cm .

Y 4 =13.130.73 Y 4 =12.4 cm.

Los tirantes de cada seccin fueron:

MARIO UZURIAGA 16
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

Q
Hallando la velocidad media: Q= A V m V m=
A
Para hallar el rea se sabe que el ancho del canal es: 0.4 y se sabe el tirante por ello se calcula el rea de la
siguiente manera:
A=0.4 Y
0.024 m 0.035 m 0.024 m
V 1= =0.557 V 1= =0.6653 V 1= =0.3952
( 0.4 0.1077 ) s ( 0.4 0.1315 ) s ( 0.4 0.1518 ) s
0.024 m 0.035 m 0.024 m
V 2= =0.5831 V 2= =0.6912 V 2= =0. 4112
( 0.4 0.1029 ) s ( 0.4 0.1266 ) s ( 0.4 0.1459 ) s
0.024 m 0.035 m 0.024 m
V 3= =0.5934 V 3= =0.7056 V 3= =0. 4252
( 0.4 0.1011 ) s ( 0.4 0.124 ) s ( 0.4 0.1411 ) s
0.024 m 0.024 m 0.024 m
V 4= =0.6872 V 4= =0.8231 V 4= =0. 4838
( 0.4 0.0873 ) s ( 0.4 0.1063 ) s ( 0.4 0.124 ) s

Q (m3/s) VELOCIDAD MEDIA (Vm)

0.024 0.6052
0.035 0.7213
0.045 0.4288

MARIO UZURIAGA
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

Para
Para el caudal de 24 l/s

Y A P R V E E S S dx Xacum
(m) (m2) (m) (m) (m/s) (m) (m) (m) .
(m)
0.1077 0.0431 0.6154 0.0700 0.5571 0.1235 - 0.0016
0.1029 0.0412 0.6058 0.0679 0.5831 0.1202 0.0033 0.0018 0.0017 1.9046 1.9046
0.1011 0.0404 0.6022 0.0672 0.5935 0.1191 0.0012 0.0019 0.0019 0.6236 2.5281
0.0873 0.0349 0.5746 0.0608 0.6873 0.1114 0.0077 0.0030 0.0025 3.1312 5.6593

Para completar esta tabla se realiz los siguientes clculos:

Para el caudal de 35 l/s

Y A P R V E E S S dx Xacum
(m) (m2) (m) (m) (m/s) (m) (m) (m) .
(m)
0.1315 0.0526 0.6630 0.0793 0.6654 0.1541 - 0.0018
0.1266 0.0506 0.6532 0.0775 0.6912 0.1509 0.0031 0.0020 0.0019 1.6056 1.6056
0.1240 0.0496 0.6480 0.0765 0.7056 0.1494 0.0016 0.0022 0.0021 0.7440 2.3496
0.1063 0.0425 0.6126 0.0694 0.8231 0.1408 0.0085 0.0034 0.0028 3.0884 5.4380

MARIO UZURIAGA
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

Para un caudal de 45 l/s

MARIO UZURIAGA
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

Y A P R V E E S S dx Xacum
(m) (m2) (m) (m) (m/s) (m) (m) (m) .
(m)
0.1518 0.0607 0.7036 0.0863 0.7411 0.1798 - 0.0020
0.1459 0.0584 0.6918 0.0844 0.7711 0.1762 0.0036 0.0022 0.0021 1.7362 1.7362
3.1.2 FLUJO RAPIDAMENTE
VARIADO 0.1411 0.0564 0.6822 0.0827 0.7973 0.1735 0.0027 0.0024 0.0023 1.1819 2.9180 (RESALTO
0.1240 0.0496 0.6480 0.0765 0.9073 0.1660 0.0075 0.0034 0.0029 2.5889 5.5069 HIDRULICO)

Ancho del canal : 40 cm

Se realiz los siguientes clculos:

BaCc 0450 . 656


Qteorico = 2 gh1=0 . 40 . 29 . 810 .3247


1+
Cca
h1
1+0 .
6560 . 045
0 .32 4 7
= 0.0285 m3/s

Se calculo los siguientes tirantes tericos:

|MARIO UZURIAGA 19
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

y 2,teorico =
y1
2
+
( y 1 2 2 v 21 y 1
2 ) +
g
=0.125 m

(
2
y y 2 2 2 v2 y2
y 1,teorico = 2 +
2 2 ) +
g
=0.0833 m

Q 0.03
v 1= = =1.442 m/s
B y 1 0.4 0.052

Q 0.03
v 2= = =0.905 m/ s
B y 2 0.4 0.0829

Se calcul el cd de esta manera:

Cd = Qreal / Q teorico = 0.03 / 0.0285 = 1.051

Se calcul el Froude de esta manera:

v1 1.442
Fr= = =2.019
g y1 9.81 0.052

|MARIO UZURIAGA 20
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

EXPERIMENTO

h1 32.47
h2 2.95
0.0829
Relacin real: y1 5.2 y 2 / y 1= =1.594
0.052
y2 8.29

0.125
Relacin terica: y 2 / y 1teorico = =1.5
0.0833

3
( y 2 y 1 ) ( 0.08290.052 )3
E= = =0.00171 m
4 y1 y2 4(0.052)(0.0829)

Lteorico=6.9 ( y 2 y 1 )=6.9( 0.1250.0833 )=0.288m

|MARIO UZURIAGA 21
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

h2
a (cm) h1 (cm) Q (lps)
(cm)

Exp 1 4.5 32.47 2.95 30

y2/y1 y2/y1 E (cm) Tipo de


QTEORICO CD Y1 teorico y2 teorico Fr1 (*) Lteorico(m)
(*) teorica (*) flujo

0.083 1.594
0.0285 1.0510 0.1250 2.012 1.5006 0.0017 0.2880 Ondulado
3 0

|MARIO UZURIAGA 22
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

3.2 DISCUSIN DE RESULTADOS

3.2.1 FLUJO PERMANENTE Y UNIFERME EN CANALES

Los coeficientes hallados mediante Manning son


similares a los hallados con la frmula de Horton-Eisntein
cuando el caudal es pequeo, pero mientras aumenta el
caudal varan ms. Probablemente se deba a que el
medidor del caudal fallaba en la medicin.
Los valores hallados en Chezy y Manning estn dentro
del rango aceptable. En el caso del K de Darcy-
Weisbach, se tienen valores negativos que
probablemente se deba a errores de medicin por el
limnmetro.
La lnea de energa y la pendiente tienen un cambio muy
pequeo, lo cual indica que el flujo se puede considerar
como un flujo uniforme.
El valor C de Chezy tiende a aumentar cuando el caudal
aumenta, lo cual demuestra la relacin directamente
proporcional que presenta.
El coeficiente de Manning disminuye a medida que la
velocidad aumenta, esto demuestra la relacin
indirectamente proporcional que presenta.

3.2.2 FLUJO GRADUALMENTE VARIADO (PERFILES)

El medidor del caudal no es muy preciso, ya que la aguja


vibraba demasiado as el caudal este constante.
Uno de los limnmetros no era muy preciso, ya que se
mova cuando tocaba el fondo el canal y esto generaba
error en la medicin del tirante.
El coeficiente de rugosidad que se uso fue para concreto,
cuando en realidad se tiene un concreto revestido por
pintura.
El coeficiente de viscosidad del agua que se us en la
frmula de Darcy-Weisbach fue 10E-6, lo cual es una
aproximacin estndar.

|MARIO UZURIAGA 22
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

3.2.3 FLUJO RAPIDAMENTE VARIADO (RESALTO HIDRULICO)

El medidor del caudal no es muy preciso, ya que la aguja


vibraba demasiado as el caudal este constante.
El coeficiente de rugosidad que se uso fue para concreto,
pero en realidad se tiene un concreto revestido por
pintura.
El coeficiente de viscosidad del agua que se us en la
frmula de Darcy-Weisbach fue 10E-6, lo cual es una
aproximacin estndar.

4 CONCLUSIONES Y RECOMENDACIONES

4.1 FLUJO PERMANENTE Y UNIFERME EN CANALES


La lnea de energa y la pendiente tienen un cambio muy
pequeo, lo cual indica que el flujo se puede considerar
como un flujo uniforme.
Es posible aplicar las frmulas de anlisis de flujos
permanentes y uniformes en canales como estos si se
producen flujos gradualmente variado para el caso de
pendiente nula.
Lograr obtener un flujo uniforme es muy difcil de realizar,
y solo se puede tener flujos con caractersticas
aproximadas a esta dndole las condiciones necesarias
para que se produzca. Mientras menos prdidas haya en
el canal, tendremos resultados ms aproximados.
Los valores de rugosidad obtenidas en las tablas segn
el material son promedios, por lo cual no se puede aplicar
con exactitud en cualquier material, ya que las
condiciones en las que se encuentren pueden ser
especiales y diferentes a cualquier otro.

4.2 FLUJO GRADUALMENTE VARIADO (PERFILES)


El mtodo tramo a tramo resulta bien prctico para
determinar perfiles de un flujo. Ya que de manera simple
y experimental se pueden tomar las mediciones y realizar
los clculos. Este mtodo tiene sus dificultados respecto
a la veracidad de los resultados obtenidos ya que pueden
llegar a variar mucho dependiendo de las condiciones del
canal y si hay perturbaciones y filtraciones a lo largo del
canal.
Las pendientes obtenidas son sumamente pequeas, lo
cual nos indica que estamos presenciado un flujo
gradualmente variado.
Mientras el canal avanza el tirante disminuye por efectos
de la friccin, que vara gradualmente.

|MARIO UZURIAGA 23
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

Como el tirante disminuye, tambin lo hace el rea, lo


cual ocasiona un aumento de la velocidad, ya que el
caudal se mantiene.
La lnea de energa tiende a disminuir debido a las
prdidas (como la friccin) que se dan a lo largo del
canal.

4.3 FLUJO RAPIDAMENTE VARIADO (RESALTO HIDRULICO)


Es necesario algo que provoque un remanso para que
este tipo de resalto hidrulico este por debajo de una
compuerta. Al mismo tiempo, generar un resalto
hidrulico bien realizado es difcil de lograr.

Es importante sealar que en esta experiencia, la toma


de datos puede ser algo inexacta, por ser subjetiva y
dependiente de cada observador. Adems, la superficie
del flujo cerca al resalto es irregular y muy turbulenta. Lo
cual, hace difcil la medicin de las cotas de superficie del
agua.

El flujo rpido (descarga libre) es provocado por las


condiciones aguas arriba, en cambio, el flujo tranquilo
(pasando el resalto hidrulico) es controlada por las
condiciones del flujo aguas abajo.

Se logr comprobar ciertos comportamientos del resalto


hidrulico, el cual produce prdida de energa en el flujo
(en promedio las prdidas representan un 25% de la
energa total). Al mismo tiempo, se observa que estos
resaltos son buenas cmaras de mezclado y sirven para
oxigenar el agua.

|MARIO UZURIAGA 24
| LABORATORIO DE HIDRULICA DE CANALES ABIERTOS

5 BIBLIOGRAFA

PONTIFICIA UNIVERSIDAD CATLICA DEL PER


PUCP 2015 MANUAL DE LABORATORIO DE
HIDRULICA DE CANALES. Lima, abril 2015

SILVA, Marisa.
HIDRULICA DE CANALES, Apuntes de clase. Lima,
2015

ROCHA FELICES, Arturo


HIDRULICA DE TUBERAS Y CANALES. Lima, enero
2007

|MARIO UZURIAGA 25