Documentos de Académico
Documentos de Profesional
Documentos de Cultura
CHACARA
CHACARA
Instalaciones Elctricas
Universidad Alas Peruanas
N Potenci
EQUIPO a
Kw/Hrs
S N(watt % de
AMBIENTE EQUIPOS s) Uso POT. U
PRIMER PISO
luminaria 1 22 0.022 100% 22
SALA Televisor 1 120 0.12 65% 78
Ventilador 1 35 0.035 70% 24.5
refrigeradora 1 240 0.24 60% 144
microondas 1 1250 1.25 70% 875
COCINA 1
olla arrocera 1 700 0.7 80% 560
luminaria 1 20 0.02 100% 20
licuadora 1 350 0.35 70% 245
Radio 1 280 0.28 70% 196
DVD 1 10 0.01 100% 10
1
HABITACIN luminaria 18 0.018 100% 18
1 televisor 1 120 0.12 65% 78
Plancha 1 1600 1.6 75% 1200
Radio 1 280 0.28 70% 196
1
HABITACIN DVD 10 0.01 100% 10
2 luminaria 1 18 0.018 100% 18
televisor 1 120 0.12 65% 78
Secador de 1
pelo 1250 1.25 80% 1000
1
HABITACIN DVD 10 0.01 100% 10
3 luminaria 1 18 0.018 100% 18
televisor 1 120 0.12 65% 78
BAO luminaria 1 100 0.1 100% 20
SEGUNDO PISO
televisor 1 120 0.12 65% 78
1
HABITACIN luminaria 18 0.018 100% 18
1 laptop 1 90 0.09 70% 63
parlantes 1 60 0.06 75% 45
PAG. 1
Escuela Profesional de Ingeniera Civil
Instalaciones Elctricas
Universidad Alas Peruanas
EQUIPOS N
EQUIPO Potenci Kw/Hr % de Uso POT.
AMBIENTE S a s USO
6808.6
fs
= 9474 = 0.720
PAG. 2
Escuela Profesional de Ingeniera Civil
Instalaciones Elctricas
Universidad Alas Peruanas
Potencia
Hrs. uso Kw/Hrs EQUIPO ENCENDIDO - MIERCOLES
(watts)
01:00
144 0.144 Refrigeradora
a.m.
02:00
144 0.144 Refrigeradora
a.m.
03:00
144 0.144 Refrigeradora
a.m.
04:00
144 0.144 Refrigeradora
a.m.
05:00
144 0.144 Refrigeradora
a.m.
06:00 Refrigeradora + 1 lmpara sala +1 lmpara
258 0.258
a.m. cocina +TV sala
07:00 Refrigeradora+ Licuadora+1 luminaria de
411 0.411
a.m. sala+ TV sala
08:00
240 0.24 Refrigeradora+1 lmpara +1 TV (P1)
a.m.
09:00
222 0.222 Refrigeradora, TV de sala
a.m.
10:00
222 0.222 Refrigeradora, TV de sala
a.m.
11:00
232 0.232 Refrigeradora+Luminaria cocina + TV sala
a.m.
12:00 Refrigeradora+ arrocera + 1 Lmpara+
967 0.967
a.m. licuadora
01:00
222 0.222 Refrigeradora+ TV sala
p.m.
02:00
300 0.3 Refrigeradora+ 2 TV (P1)
p.m.
03:00
300 0.3 Refrigeradora+ 2 TV (P1)
p.m.
04:00
300 0.3 Refrigeradora+ 2 TV (P1)
p.m.
05:00
300 0.3 Refrigeradora+ 2 TV (P1)
p.m.
06:00
354 0.354 Refrigeradora, 3 Lmparas+ 2 TV (P1)
p.m.
07:00
354 0.354 Refrigeradora, 3 Lmparas+ 2 TV (P1)
p.m.
08:00 Refrigeradora, 3 Lmparas+ 2 TV (P1)+1
432 0.432
p.m. TV (P2)
09:00 Refrigeradora, 3 Lmparas+ 2 TV (P1)+1
432 0.432
p.m. TV (P2)
PAG. 3
Escuela Profesional de Ingeniera Civil
Instalaciones Elctricas
Universidad Alas Peruanas
Potencia
Hrs. uso Kw/Hrs EQUIPOS ENCENDIDOS - SABADO
(watts)
01:00
144 0.144 Refrigeradora
a.m.
02:00
144 0.144 Refrigeradora
a.m.
03:00
144 0.144 Refrigeradora
a.m.
04:00
144 0.144 Refrigeradora
a.m.
05:00
144 0.144 Refrigeradora
a.m.
06:00
260 0.26 Refrigeradora+2 luminaria+ TV sala
a.m.
07:00 Refrigeradora+ Luminaria sala+1 TV(P1)+1 TV
322 0.322
a.m. (P2
08:00
222 0.222 Refrigeradora+ TV sala
a.m.
09:00
222 0.222 Refrigeradora+ TV sala
a.m.
10:00
222 0.222 Refrigeradora + 1 TV (P2)
a.m.
11:00
222 0.222 Refrigeradora + 1 TV (P2)
a.m.
PAG. 4
Escuela Profesional de Ingeniera Civil
Instalaciones Elctricas
Universidad Alas Peruanas
Potencia
Hrs. en uso Kw/Hrs EQUIPOS ENCENDIDOS - DOMINGO
(watts)
01:00
144 0.144 Refrigeradora
a.m.
02:00
144 0.144 Refrigeradora
a.m.
PAG. 5
Escuela Profesional de Ingeniera Civil
Instalaciones Elctricas
Universidad Alas Peruanas
03:00
144 0.144 Refrigeradora
a.m.
04:00
144 0.144 Refrigeradora
a.m.
05:00
144 0.144 Refrigeradora
a.m.
06:00
144 0.144 Refrigeradora
a.m.
07:00
144 0.144 Refrigeradora
a.m.
08:00
389 0.389 Refrigeradora +licuadora
a.m.
09:00
378 0.378 Refrigeradora + 2 TV (P1)+ 1 TV (P2)
a.m.
10:00
378 0.378 Refrigeradora + 2 TV (P1)+ 1 TV (P2)
a.m.
11:00
378 0.378 Refrigeradora + 2 TV (P1)+ 1 TV (P2)
a.m.
12:00 Refrigeradora + arrocera+ lmpara
802 0.802
a.m. cocina +TV sala
01:00
418 0.418 Refrigeradora + TV sala+ radio
p.m.
02:00
222 0.222 Refrigeradora + TV sala
p.m.
03:00
222 0.222 Refrigeradora + TV sala
p.m.
04:00
222 0.222 Refrigeradora + TV sala
p.m.
05:00
222 0.222 Refrigeradora + TV sala
p.m.
06:00
276 0.276 Refrigeradora+ 3 Lmparas + TV sala
p.m.
07:00 Refrigeradora+ 3 Lmparas + 2 TV
432 0.432
p.m. (P1)+1 TV (P2)
08:00 Refrigeradora+ 3 Lmparas + 2 TV
432 0.432
p.m. (P1)+1 TV (P2)
09:00 Refrigeradora+ 3 Lmparas + 2 TV
432 0.432
p.m. (P1)+1 TV (P2)
10:00 Refrigeradora+ 3 Lmparas + 2 TV
432 0.432
p.m. (P1)+1 TV (P2)
11:00
232 0.232 Refrigeradora + 1 TV +1 DVD
p.m.
12:00
232 0.232 Refrigeradora + 1 TV + 1 DVD
p.m.
7.107
kw/h
PAG. 6
Escuela Profesional de Ingeniera Civil
Instalaciones Elctricas
Universidad Alas Peruanas
POTENCIA - Kw/h
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
PAG. 7
Escuela Profesional de Ingeniera Civil
Instalaciones Elctricas
Universidad Alas Peruanas
POTENCIA Kw/h
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
POTENCIA Kw/h
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
PAG. 8
Escuela Profesional de Ingeniera Civil
Instalaciones Elctricas
Universidad Alas Peruanas
PAG. 9
Escuela Profesional de Ingeniera Civil
Instalaciones Elctricas
Universidad Alas Peruanas
- Plancha primero la ropa gruesa, o que necesite ms calor, y deja para el final la delgada,
que requiere menos calor; desconecta la plancha poco antes de terminar para aprovechar
la temperatura acumulada.
- No dejes la plancha conectada innecesariamente
- Revisa la superficie de la plancha para que est siempre tersa y limpia; as se transmitir
el calor de manera uniforme
- Revisa que el cable y la clavija estn en buenas condiciones.
Instalacin elctrica:
- Comprueba que la instalacin elctrica no tenga fugas. Para eso, desconecta todos los
aparatos elctricos, incluyendo relojes y timbre; apaga todas las luces y verifica que el
disco del medidor no gire; si el disco sigue girando, manda revisar la instalacin.
Observaciones:
En algunos artefactos no encontramos la potencia nominal, entonces se
tuvo que obtener multiplicando la tensin por la corriente, estos son datos
que siempre encontraremos en cualquier tipo de electrodomsticos.
Para graficar los datos obtenidos en watts, los tuvimos que convertir a Kw.
1
PAG.
0
Escuela Profesional de Ingeniera Civil
Instalaciones Elctricas
Universidad Alas Peruanas
Recomendaciones:
Tener una buena conexin de cables y que estos no estn suelto, sera un
gran riesgo para la familia.
1
PAG.
1
Escuela Profesional de Ingeniera Civil
Instalaciones Elctricas
Universidad Alas Peruanas
1
PAG.
2