Está en la página 1de 13

REDES DE INTERCAMBIADORES DE CALOR

SINTESIS SECUENCIAL
CORRIENTES CALIENTES Y FRIAS

1 2 1.5 1.3 H1 H2 C1 C2
420 400

30

H1
400 380

60 90

H2
340 320

250 160 320 240 117

180 160 C1
60 120 78

120 100 C2 280 440 360 195


REDES DE INTERCAMBIADORES DE CALOR
SINTESIS SECUENCIAL - PROBLEMA DEL TRANSPORTE
DIAGRAMA EN CASCADA

QS
420 400
C1
30 360
1
400 R1 380
H1
280 60 90
2
160 340 R2 320
240

320
3 117 C2
H2 R3 195
440 180 160
60
78
120
4
120 100
QW
REDES DE INTERCAMBIADORES DE CALOR
CALENTAMIENTO Y ENFRIAMIENTO MINIMO
PROBLEMA DEL TRANSPORTE

Minimizar Z = Qs + Qw

sujeto a R1 - Qs = -30
R2 - R1 = -30
R3 - R2 = 123
Qw - R3 = 102

Qs, Qw, R1, R2, R3 >= 0

SOLUCION: Qs = 60 MW
Qw = 225 MW
R1 = 30 MW
R2 = 0 MW (PINCH 340 C - 320 C)
R3 = 123 MW

EXCEL
REDES DE INTERCAMBIADORES DE CALOR
CALENTAMIENTO Y ENFRIAMIENTO MINIMO
PROBLEMA DEL TRANSPORTE GENERALIZADO

Corrientes
R k -1
Calientes Corrientes
H
Frias
Q
i H k
ik

C
Q
j C k
jk

Intervalo k
W
S Q n
Q
m Sk
m n Wk
Servicios
de
Servicios Rk Enfriamientos
de
Calores
Calentamientos
Residuales
REDES DE INTERCAMBIADORES DE CALOR
COSTO MINIMO DE CALENTAMIENTO Y ENFRIAMIENTO
PROBLEMA GENERAL DEL TRANSPORTE

S W
Minimizar Z cmQ m c Q n n
m S nW

S W H C
sujeto a R k - R k -1 - m
Q
m S k
n
Q
n Wk
ik -
Q
iHk
jk k 1,...,K
Q
jC k
S W
Q 0, Q 0, R k 0, k 1,...., K- 1
m n

R o 0, R K 0
REDES DE INTERCAMBIADORES DE CALOR
COSTO MINIMO DE CALENTAMIENTO Y ENFRIAMIENTO
CORRIENTES CALIENTES Y FRIAS

QHP
2.5 3.8 2 2
430 420

H1
400 390 UTILIDADES

R1 HP VAPOR ( 500 K): $ 80 / KW - AO

LP VAPOR ( 380 K): $ 50 / KW - AO


380 370

QLP R2 CW AGUA ( 300 K): $ 20 / KW - AO

H2 HRAT : 10 K
370 360

R3
320

310 300 C1 C2
QCW
REDES DE INTERCAMBIADORES DE CALOR
COSTO MINIMO DE CALENTAMIENTO Y ENFRIAMIENTO
PROBLEMA GENERAL DEL TRANSPORTE

Minimizar Z = 80000*QHP + 50000*QLP + 20000*QCW


sujeto a R1 - QHP = - 60
R2 - R1 = 10
R3 - R2 - QLP = - 15
QCW - R3 = 75

QHP, QLP, QCW, R1, R2, R3 >= 0

SOLUCION: Z = $6.550.000 / AO
QHP = 60 MW
QLP = 5 MW
QCW =75 MW

R1 = 0 (PINCH 400 - 390C)


R2 = 10 MW
R3 = 0 (PINCH 370 - 360C)

SUBRED 1: POR ENCIMA DE 400 - 390C


SUBRED 2: ENTRE 400 - 390C Y 370 - 360C
SUBRED 3: DEBAJO DE 370 - 360C
HEN-2
REDES DE INTERCAMBIADORES DE CALOR
PROBLEMA DEL TRANSPORTE EXPANDIDO

42 Qs 40
0 Intervalo 1 0
QS11
C1 360
30

40 90
RS1 380 240
0 Intervalo 2
QS12
H1
280 60 Q112

60 160 340 RS2 R12 320


Intervalo 3
QS13

QS23

Q113

Q123

Q213

Q223

180 RS3 R13 R23 160


Intervalo 4
H2 320
440 QS24
117 C2
Q1W4 Q124
78 195
120
Q224
Q2W4

100
120
Qw
REDES DE INTERCAMBIADORES DE CALOR
COSTO MINIMO DE CALENTAMIENTO Y ENFRIAMIENTO
PROBLEMA DEL TRANSPORTE EXPANDIDO

Minimizar Z = 80000*QS + 20000*QW


sujeto a

Intervalo 1 RS1 + QS11 - QS = 0


QS11 = 30
Intervalo 2 R12 + Q112 = 60
RS2 - RS1 + QS12 = 0
QS12 + Q112 = 90
Intervalo 3 R13 - R12 + Q113 + Q123 = 160
R23 + Q213 + Q223 = 320
RS3 - RS2 + QS13 + QS23 = 0
Q113 + Q213 + QS13 = 240
Q123 + Q223 + QS23 = 117
Intervalo 4 -R13 + Q124 +Q1W4 = 60
-R23 + Q224 + Q2W4 = 120
-RS3 + QS24 = 0
Q124 + Q224 + QS24 = 78
Q1W4 + Q2W4 - QW = 0
Cruce Restringido Q112 = Q113 = 0

SOLUCION: Z = $15.300.000 / AO
QS = 120 MW
QW = 285 MW
REDES DE INTERCAMBIADORES DE CALOR
COSTO MINIMO DE CALENTAMIENTO Y ENFRIAMIENTO
PROBLEMA DEL TRANSPORTE EXPANDIDO

Ri,k - 1 Rm,k - 1

Qink D
Q ikH Q nW
Qijk
Q Cjk
C

QSm Qmjk

Rik Rmk
REDES DE INTERCAMBIADORES DE CALOR
COSTO MINIMO DE CALENTAMIENTO Y ENFRIAMIENTO
PROBLEMA DEL TRANSPORTE EXPANDIDO

S W
Minimizar Z m m
c Q
m S nW
n n
c Q
H
sujeto a R ik - R i,k - 1 Qijk ink ik
Q Q i H 'k
j Ck n Wk

R mk - R m, k - 1 Q mjk - Q Sm 0 m S'k
j Ck
C
Qijk
i Hk
mjk jk
Q
m Sk
Q j Ck

W
ink n 0
Q -
i Hk
Q n Wk k 1,..., K

Q Sm , Q nW , Q ijk , Q mjk , Q ink , R ik , R mk 0


R io 0, R ik 0
K
Lmites Inferior y Superior : Q Q ijk Q ijU
L
ij
k 1
REDES DE INTERCAMBIADORES DE CALOR
NUMERO MINIMO DE INTERCAMBIADORES
PROBLEMA DEL TRANSPORTE EXPANDIDO (MILP)

Minimizar Z y ijq
i H j C
H
sujeto a R ik - R i, k - 1 - ijk ik
Q Q i Hk k 1,..., K
j Ck
C
ijk jk
Q
iH k
Q j C k

Kq
q
ijk ij ij 0
Q
k 1
U y

y ijq [1,0]
R ik , Q ijk 0
REDES DE INTERCAMBIADORES DE CALOR
NUMERO MINIMO DE INTERCAMBIADORES
PROBLEMA DEL TRANSPORTE EXPANDIDO

Minimizar Z = YS1A + Y11A + Y11B + Y12B + Y1WB + Y21B + Y22B + Y2WB


sujeto a
Intervalo 1 RS1 + QS11 = 60
QS11 = 30 SOLUCION
Intervalo 2 R12 + Q112 = 60
RS2 - RS1 + QS12 = 0 Encima del Pinch:
QS12 + Q112 = 90
Intervalo 3 R13 - R12 + Q113 + Q123 = 160 S - C1 60 MW (YS1A = 1, QS11 = 30, QS12 = 30)
R23 + Q213 + Q223 = 320 H1 - C1 60 MW (Y11A = 1, Q112 = 60)
RS3 - RS2 + QS13 + QS23 = 0
Q113 + Q213 + QS13 = 240 Debajo del Pinch:
Q123 + Q223 + QS23 = 117
Intervalo 4 -R13 + Q124 +Q1W4 = 60 H1 - C1 25 MW (Y11B = 1, Q113 = 25)
-R23 + Q224 + Q2W4 = 120 H1 - C2 195 MW (Y12B = 1, Q123 = 117, Q124 = 78)
-RS3 + QS24 = 0 H2 - C1 215 MW (Y21B = 1, Q213 = 215)
Q124 + Q224 + QS24 = 78 H2 - W 225 MW (Y2WB = 1, Q2W4 = 225)
Q1W4 + Q2W4 = 225
Encima del Pinch QS11 + QS12 - 60YS1A <= 0
Q112 - 60Y11A <= 0
Debajo del Pinch Q113 - 220Y11B <= 0
Q123 + Q124 - 195Y12B <= 0
Q1W4 - 220Y1WB <= 0
Q213 - 240Y21B <= 0
Q223 + Q224 - 60Y22B <= 0
Q2W4 - 225Y2WB <= 0