Está en la página 1de 11

RESERVORIO (consumo L/s)

tiempo
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

a)
b)

C)

d)

variaciones de Cparcial
volumen de consumo
C. acumulado P.parcial
P. acumulado
68.84
68.84
68.84
112.90
112.90
69.97
69.97
138.81
112.90
225.79
68.84
68.84
207.65
112.90
338.69
64.32
64.32
271.97
112.90
451.58
64.32
64.32
336.29
112.90
564.48
63.19
63.19
399.48
112.90
677.37
88.02
88.02
487.50
112.90
790.27
155.73
155.73
643.23
112.90
903.16
171.53
171.53
814.76
112.90
1016.06
171.53
171.53
986.29
112.90
1128.95
159.12
159.12
1145.41
112.90
1241.85
155.73
155.73
1301.14
112.90
1354.74
155.73
155.73
1456.87
112.90
1467.64
155.73
155.73
1612.60
112.90
1580.53
155.73
155.73
1768.33
112.90
1693.43
159.12
159.12
1927.45
112.90
1806.32
128.65
128.65
2056.10
112.90
1919.22
119.62
119.62
2175.72
112.90
2032.11
115.1
115.1
2290.82
112.90
2145.01
102.69
102.69
2393.51
112.90
2257.90
89.15
89.15
2482.66
112.90
2370.80
82.38
82.38
2565.04
112.90
2483.69
80.12
80.12
2645.16
112.90
2596.59
64.32
64.32
2709.48
112.90
2709.48
promedio
112.90 l/s

RESERVORIO 24H
Pacum-C acum
44.06
86.98
131.04
179.61
228.19
277.89
302.77
259.93
201.30
142.66
96.44
53.60
10.77
-32.07
-74.91
-121.13
-136.89
-143.61
-145.82
-135.61
-111.87
-81.35
-48.57
0.00

capacidad de descarga de unavolumen


bomba simple
regulado
para operar coninuamente a razon promedio de la demanda
Q=
112.90 l/s
cual sera la capcidad del reservorio para permitir a la omba operar continuamente con esa descarga.
Q=
448.58 l/s
VR=
38757 m3
bombeando las 24 horas
cual sera la capacdidad del reservorio si la bomba opera a razon constante durante 12 horas en el turno de 4am-8am
Q=
225.79 l/s
con que volumen debe iniciarse la operacin para el caso c
VR

70298 m3

P.parcial

225.79
225.79
225.79
225.79
225.79

225.79
225.79
225.79
225.79
225.79
225.79
225.79

RESERVORIO 12H
P. acumulado Pacum-C acum
0
-68.84
0
-138.81
0
-207.65
226
-46.18
452
115.29
677
277.89
903
415.66
1129
485.72
1129
314.19
1129
142.66
1129
-16.46
1129
-172.19
1129
-327.92
1355
-257.86
1581
-187.80
1806
-121.13
2032
-23.99
2258
82.18
2484
192.87
2709
315.97
2709
226.82
2709
144.44
2709
64.32
2709
0.00
VR=
VR=

nuamente con esa descarga.

nte durante 12 horas en el turno de 4am-8am y 2pm-8pm

volumen de consumo (m3)


5948
11993
17941
23498
29055
34515
42120
55575
70395
85215
98963
112418
125874
139329
152784
166532
177647
187982
197927
206799
214502
221619
228542
234099
813.64 l/s
70298 m3

RESERVORIO (consumo m3)


tiempo
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1
2
3
4
5
6

a)
b)

C)

variaciones de Cparcial
volumen de consumo
C. acumulado P.parcial
P. acumulado
2000
2000
2000
4400.00
4400.00
3400
3400
5400
4400.00
8800.00
4800
4800
10200
4400.00
13200.00
5200
5200
15400
4400.00
17600.00
5400
5400
20800
4400.00
22000.00
5600
5600
26400
4400.00
26400.00
5800
5800
32200
4400.00
30800.00
6000
6000
38200
4400.00
35200.00
6600
6600
44800
4400.00
39600.00
6400
6400
51200
4400.00
44000.00
5600
5600
56800
4400.00
48400.00
6400
6400
63200
4400.00
52800.00
7200
7200
70400
4400.00
57200.00
8000
8000
78400
4400.00
61600.00
8760
8760
87160
4400.00
66000.00
5600
5600
92760
4400.00
70400.00
3200
3200
95960
4400.00
74800.00
2200
2200
98160
4400.00
79200.00
1200
1200
99360
4400.00
83600.00
1240
1240
100600
4400.00
88000.00
1400
1400
102000
4400.00
92400.00
1000
1000
103000
4400.00
96800.00
1200
1200
104200
4400.00
101200.00
1400
1400
105600
4400.00
105600.00
promedio
4400.00 m3

RESERVORIO 24H
Pacum-C acum
2400
3400
3000
2200
1200
0
-1400
-3000
-5200
-7200
-8400
-10400
-13200
-16800
-21160
-22360
-21160
-18960
-15760
-12600
-9600
-6200
-3000
0

capacidad de descarga de unavolumen


bomba simple
regulado
para operar coninuamente a razon promedio de la demanda
Q=
4400 m3
1222.22222 l/s
cual sera la capcidad del reservorio para permitir a la omba operar continuamente con esa descarga.
VR=
25760 m3
bombeando las 24 horas
cual sera la capacdidad del reservorio si la bomba opera a razon constante durante 8 horas en el turno de 4am-8am
Q=
13200 m3
3666.66667 l/s

P.parcial
13200
13200
13200
13200

13200
13200
13200
13200

13200
13200
13200

RESERVORIO 12H
P. acumulado Pacum-C acum
13200
11200
26400
21000
39600
29400
52800
37400
52800
32000
52800
26400
52800
20600
52800
14600
66000
21200
79200
28000
92400
35600
105600
42400
105600
35200
105600
27200
105600
18440
105600
12840
105600
9640
105600
7440
105600
6240
105600
5000
105600
3600
118800
15800
132000
27800
145200
39600

nuamente con esa descarga.

nte durante 8 horas en el turno de 4am-8am y 2pm-8pm

volumen de consumo (m3)


172800
466560
881280
1330560
1797120
2280960
2782080
3300480
3870720
4423680
4907520
5460480
6082560
6773760
7530624
8014464
8290944
8481024
8584704
8691840
8812800
8899200
9002880
9123840

RESERVORIO (consumo m3)


tiempo

%Qmd
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

a)
b)

C)

Cparcial
C. acumulado P.parcial
P. acumulado
0.25
23.4
23.4
397.38
397.38
0.25
23.4
46.8
397.38
794.75
0.5
46.8
93.5
397.38
1192.13
2
187.0
280.5
397.38
1589.50
2
187.0
467.5
397.38
1986.88
5
467.5
935.0
397.38
2384.25
5
467.5
1402.5
397.38
2781.63
5
467.5
1870.0
397.38
3179.00
2.5
233.8
2103.8
397.38
3576.38
1.25
116.9
2220.6
397.38
3973.75
1.25
116.9
2337.5
397.38
4371.13
10
935.0
3272.5
397.38
4768.50
10
935.0
4207.5
397.38
5165.88
10
935.0
5142.5
397.38
5563.25
2.5
233.8
5376.3
397.38
5960.63
2.5
233.8
5610.0
397.38
6358.00
5
467.5
6077.5
397.38
6755.38
6
561.0
6638.5
397.38
7152.75
11
1028.5
7667.0
397.38
7550.13
10
935.0
8602.0
397.38
7947.50
5
467.5
9069.5
397.38
8344.88
2.5
233.8
9303.3
397.38
8742.25
2.25
210.4
9513.6
397.38
9139.63
0.25
23.4
9537.0
397.38
9537.00
102 promedio
397.38 m3

RESERVORIO 24H
Pacum-C acum
374
748
1099
1309
1519
1449
1379
1309
1473
1753
2034
1496
958
421
584
748
678
514
-117
-655
-725
-561
-374
0

capacidad de descarga de unavolumen


bomba simple
regulado
para operar coninuamente a razon promedio de la demanda
Q=
397 m3
110.381944 l/s
cual sera la capcidad del reservorio para permitir a la omba operar continuamente con esa descarga.
VR=
2758 m3
bombeando las 24 horas
cual sera la capacdidad del reservorio si la bomba opera a razon constante durante 8 horas en el turno de 4am-8am
Q=
953.7 m3
264.916667 l/s
VR

2318.8

P.parcial

953.7
953.7
953.7
953.7
953.7
953.7
953.7
953.7
953.7
953.7

RESERVORIO 12H
P. acumulado Pacum-C acum
0
-23.4
0
-46.8
0
-93.5
0
-280.5
0
-467.5
0
-935.0
953.7
-448.8
1907.4
37.4
2861.1
757.4
3814.8
1594.2
4768.5
2431.0
5722.2
2449.7
6675.9
2468.4
7629.6
2487.1
8583.3
3207.1
9537.0
3927.0
9537.0
3459.5
9537.0
2898.5
9537.0
1870.0
9537.0
935.0
9537.0
467.5
9537.0
233.8
9537.0
23.4
9537.0
0.0

nuamente con esa descarga.

te durante 8 horas en el turno de 4am-8am y 2pm-8pm

volumen de consumo (m3)


2020
4039
8078
24235
40392
80784
121176
161568
181764
191862
201960
282744
363528
444312
464508
484704
525096
573566
662429
743213
783605
803801
821977
823997

CONSIDERANDO UN CRECIEMIENTO POBLACIONAL GEOMETRICAMENTE


p
388800
DOTACION
70 L/H/DIA
r
0.02
AO
POBLACION
Qm
Qmd
porcentaje
0
144450
117
152
1.15
1
147339
119
155
1.17
2
150286
122
158
1.19
3
153291
124
161
1.22
4
156357
127
165
1.24
5
159484
129
168
1.27
6
162674
132
171
1.29
7
165928
134
175
1.32
8
169246
137
178
1.34
9
172631
140
182
1.37
10
176084
143
185
1.40
11
179605
146
189
1.42
12
183198
148
193
1.45
13
186861
151
197
1.48
14
190599
154
201
1.51
15
194411
158
205
1.54
16
198299
161
209
1.57
17
202265
164
213
1.60
18
206310
167
217
1.64
19
210436
170
222
1.67
20
214645
174
226
1.70
21
218938
177
231
1.74
22
223317
181
235
1.77
23
227783
185
240
1.81
24
232339
188
245
1.84
25
236986
192
250
1.88
26
241725
196
255
1.92
27
246560
200
260
1.96
28
251491
204
265
1.99
29
256521
208
270
2.03
30
261651
212
276
2.08
31
266884
216
281
2.12
32
272222
221
287
2.16
33
277666
225
292
2.20
34
283220
229
298
2.25
35
288884
234
304
2.29
36
294662
239
310
2.34
37
300555
244
317
2.38
38
306566
248
323
2.43
39
312697
253
329
2.48
40
318951
258
336
2.53
41
325330
264
343
2.58
42
331837
269
350
2.63

43
44
45
46
47
48
49
50

338474
345243
352148
359191
366375
373702
381176
388800

274
280
285
291
297
303
309
315
10213

356
364
371
378
386
394
401
409
13277

2.68
2.74
2.79
2.85
2.91
2.96
3.02
3.08

CONSIDERANDOUN CRECIMIENTO POBLACIONAL ARITMETICO


P
28000
dotacion
r
350
AO
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

poblacion
Qm
28000
28350
28700
29050
29400
29750
30100
30450
30800
31150
31500
31850
32200
32550
32900
33250
33600
33950
34300
34650
35000

OFERTA
m
b

16000
16188
16388
16588
16787
16987
17187
17387
17587
17787
17987
18186
18386
18586
18786
18986
19186
19385
19585
19785
19985
0
199.85
15988
-80

188
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200

0.571 m3/hab/ao

1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

0
0
1
2
3
4
5
6
7
8
9
10
11
oferta
m
b

poblacion
demanda(m3)Qmd(m3)
20000
4000.00
5200
20420
4084.00
5309
20849
4169.76
5421
21287
4257.33
5535
21734
4346.73
5651
22190
4438.01
5769
22656
4531.21
5891
23132
4626.37
6014
23618
4723.52
6141
24114
4822.72
6270
24620
4923.99
6401
25137
5027.40
6536
25665
5132.97
6673
26204
5240.76
6813
26754
5350.82
6956
27316
5463.19
7102
0
31.9809762
85.4927029
-2.7

700
600
500
400
300
200
100
0

y = 31.661x + 88.8

10

15

20

Valmacenado(m3) capacidad maxima


deficit (m3)
1300
1200
100
1327
1200
127
1355
1200
155
1384
1200
184
1413
1200
213
1442
1200
242
1473
1200
273
1504
1200
304
1535
1200
335
1567
1200
367
1600
1200
400
1634
1200
434
1668
1200
468
1703
1200
503
1739
1200
539
1776
1200
576

y = 31.661x + 88.8
Series1
Linear (Series1)

También podría gustarte