Está en la página 1de 36

IN

## LUGAR:

SANTA MARTA

ORDEN DE TRABAJO:

EMPRESA: ALFERING S.A.S

2497

NOMBRE EQUIPO:
EQUIPO No:
No PLANOS:

CLIENTE:

CEMEX COLOMBIA

ESTRUCTURA TRANSPORTADOR 131-BC-400


MODULO 2-0B
2497-11052016-01

JUNTA

LONG. (ML)

PROCESO

CORDON DE
SOLDADUR
A (mm)

J01
J02
J03
J04
J05
J06
J07
J08
J09
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38

0.50
0.70
0.30
0.25
0.30
0.15
0.6
0.7
0.15
0.6
0.3
0.50
0.60
0.50
0.15
0.7
0.6
0.70
0.15
0.30
0.3
0.1
0.15
0.29
0.250
0.29
0.25
0.1
0.29
0.25
0.15
0.5
0.15
0.29
0.25
0.15
0.25
0.29

GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
FCAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW

4
4
5
4
5
5
4
4
5
4
5
5
4
5
4
5
5
4
5
4
5
5
5
4
5
4
4
4
4
5
5
6
4
4
4
5
4
4

ALTURA
CORDON
SOLDADURA
ACEPTA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

RECHAZA

PROYECTO:
PIE:

CONSECUTIVO LISTA

ALINEAMIENTO
DE LA JUNTA

PRESENTACION
SOLDADURA

ACEPTA

ACEPTA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

RECHAZA

RECHAZA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

ESTAMPE
SOLDADOR

C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F

J39
J40

0.15
0.175

GMAW
GMAW

4
5

X
X

X
X

X
4 X

OBSERVACIONES GENERALES
NOTAS:

RESPONSABLE

QA/QC TALLER

FIRMA:
NOMBRES:

EDINSON CASTRILLO

CARGO:

SUPERVISOR CONTROL DE CALIDAD

FECHA:

5/29/2016

Pgina 1 de 1

C-F
C-F

INSPECCION VISUAL DE SOLDADURAS

ALFERING S.A.S

FECHA:

CEMEX COLOMBIA

5/28/2016

ESTRUCTURAS TRANSPORTADOR
ESTRUCTURAS
CONSECUTIVO LISTA DE CHEQUEO No:
IDENTIFICACION
DEFECTO

Socavado
Irregular
-

REPARAD OBSERVACIONES
O
PARTICULARES

si
si
-

J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 26-05
J-FILETE 27-05
J-FILETE 27-05
J-TOPE 27-05
J-FILETE 27-05
J-TOPE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-TOPE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-TOPE 27-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-TOPE 28-05

J-FILETE 28-05
J-TOPE 28-05

CC - CLIENTE

V1 - 26/01/2015

IN
## LUGAR:

SANTA MARTA

ORDEN DE TRABAJO:

EMPRESA: ALFERING S.A.S

2497

NOMBRE EQUIPO:
EQUIPO No:
No PLANOS:

CLIENTE:

CEMEX COLOMBIA

ESTRUCTURA TRANSPORTADOR 131-BC-400


MODULO 2-0B
2497-11052016-01

JUNTA

LONG. (ML)

PROCESO

CORDON DE
SOLDADUR
A (mm)

J41
J42
J43
J44
J45

0.15
0.29
0.60
0.15
0.30

GMAW
GMAW
GMAW
GMAW
FCAW

4
4
5
4
5

ALTURA
CORDON
SOLDADURA
ACEPTA

X
X
X
X
X

RECHAZA

PROYECTO:
PIE:

CONSECUTIVO LISTA

ALINEAMIENTO
DE LA JUNTA

PRESENTACION
SOLDADURA

ACEPTA

ACEPTA

X
X
X
X
X

RECHAZA

ESTAMPE
SOLDADOR

RECHAZA

X
X
X
X
X

C-F
C-F
C-F
C-F
C-F

OBSERVACIONES GENERALES
NOTAS:

RESPONSABLE

QA/QC TALLER

FIRMA:
NOMBRES:

EDINSON CASTRILLO

CARGO:

SUPERVISOR CONTROL DE CALIDAD

FECHA:

5/29/2016

Pgina 1 de 1

INSPECCION VISUAL DE SOLDADURAS

ALFERING S.A.S

FECHA:

CEMEX COLOMBIA

5/28/2016

ESTRUCTURAS TRANSPORTADOR
ESTRUCTURAS
CONSECUTIVO LISTA DE CHEQUEO No:
IDENTIFICACION
DEFECTO

PORO

REPARAD OBSERVACIONES
O
PARTICULARES

SI

J-FILETE 28-05
J-TOPE 28-05
J-TOPE 28-05
J-TOPE 28-05
J-FILETE 28-05

CC - CLIENTE

V1 - 26/01/2015

IN
## LUGAR:

SANTA MARTA

ORDEN DE TRABAJO:

EMPRESA: ALFERING S.A.S

2497

NOMBRE EQUIPO:
EQUIPO No:
No PLANOS:

CLIENTE:

CEMEX COLOMBIA

ESTRUCTURA TRANSPORTADOR 131-BC-400


MODULO 2-0B
2497-11052016-01

JUNTA

LONG. (ML)

PROCESO

CORDON DE
SOLDADUR
A (mm)

J05
J34
J45

0.30
0.29
0.30

GMAW
GMAW
FCAW

5
4
5

ALTURA
CORDON
SOLDADURA
ACEPTA

X
X
X

RECHAZA

PROYECTO:
PIE:

CONSECUTIVO LISTA

ALINEAMIENTO
DE LA JUNTA

PRESENTACION
SOLDADURA

ACEPTA

ACEPTA

X
X
X

RECHAZA

X
X
X

ESTAMPE
SOLDADOR

RECHAZA

C-F
C-F
C-F

4
OBSERVACIONES GENERALES

JUNTAS REPARADAS MODULO 2-0B

NOTAS:

RESPONSABLE

QA/QC TALLER

FIRMA:
NOMBRES:

EDINSON CASTRILLO

CARGO:

SUPERVISOR CONTROL DE CALIDAD

FECHA:

5/29/2016

Pgina 1 de 1

INSPECCION VISUAL DE SOLDADURAS

ALFERING S.A.S

FECHA:

CEMEX COLOMBIA

5/28/2016

ESTRUCTURAS TRANSPORTADOR
ESTRUCTURAS
CONSECUTIVO LISTA DE CHEQUEO No:
IDENTIFICACION
DEFECTO

REPARAD OBSERVACIONES
O
PARTICULARES

si
si
SI

J-FILETE 30-05
J-TOPE 30-05
J-FILETE 30-05

CC - CLIENTE

V1 - 26/01/2015

IN
## LUGAR:

SANTA MARTA

ORDEN DE TRABAJO:

EMPRESA: ALFERING S.A.S

2497

NOMBRE EQUIPO:
EQUIPO No:
No PLANOS:

CLIENTE:

CEMEX COLOMBIA

ESTRUCTURA TRANSPORTADOR 131-BC-400


MODULO 2-0C
2497-11052016-03

JUNTA

LONG. (ML)

PROCESO

CORDON DE
SOLDADUR
A (mm)

J01
J02
J03
J04
J05
J06
J07
J08
J09
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38

0.30
0.80
0.80
0.80
0.80
0.30
0.80
0.80
0.80
0.80
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.3
0.8
0.8
0.8
0.8
0.3
0.8
0.8
0.8
0.8
0.29
0.25

GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
FCAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW

5
5
4
4
4
4
4
4
5
4
4
4
4
4
5
4
4
4
4
5
4
5
5
4
4
5
4
5
5
4
4
4
5
4
4
4
4
4

ALTURA
CORDON
SOLDADURA
ACEPTA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

RECHAZA

PROYECTO:
PIE:

CONSECUTIVO LISTA

ALINEAMIENTO
DE LA JUNTA

PRESENTACION
SOLDADURA

ACEPTA

ACEPTA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

RECHAZA

RECHAZA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

ESTAMPE
SOLDADOR

W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P

J39
J40

0.29
0.1

GMAW
GMAW

4
4

X
X

X
X

OBSERVACIONES GENERALES
NOTAS:

RESPONSABLE
FIRMA:
NOMBRES:
CARGO:
FECHA:

Pgina 1 de 1

QA/QC TALLER

X
4 X

W-P
W-P

INSPECCION VISUAL DE SOLDADURAS

ALFERING S.A.S

FECHA:

CEMEX COLOMBIA

5/28/2016

ESTRUCTURAS TRANSPORTADOR
ESTRUCTURAS
CONSECUTIVO LISTA DE CHEQUEO No:
IDENTIFICACION
DEFECTO

Irregular
Irregular
POROS
-

REPARAD OBSERVACIONES
O
PARTICULARES

si
si
si
-

J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-TOPE 27-05
J-FILETE 27-05
J-TOPE 27-05
J-FILETE 27-05
J-FILETE 28-05
J-TOPE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-TOPE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-TOPE 28-05

J-FILETE 28-05
J-TOPE 28-05

CC - CLIENTE

V1 - 26/01/2015

IN
## LUGAR:

SANTA MARTA

ORDEN DE TRABAJO:

EMPRESA: ALFERING S.A.S

2497

NOMBRE EQUIPO:
EQUIPO No:
No PLANOS:

CLIENTE:

CEMEX COLOMBIA

ESTRUCTURA TRANSPORTADOR 131-BC-400


MODULO 2-0C
2497-11052016-03

JUNTA

LONG. (ML)

PROCESO

CORDON DE
SOLDADUR
A (mm)

J41
J42
J43
J44
J45
J46
J47
J48
J49
J50
J51
J52
J53
J54
J55
J56
J57
J58
J59
J60
J61
J62
J63
J64
J65
J66
J67
J68
J69
J70

0.25
0.29
0.25
0.29
0.10
0.25
0.29
0.10
0.25
0.29
0.25
0.29
0.10
0.25
0.29
0.25
0.29
0.25
0.29
0.25
0.29
0.25
0.29
0.25
0.29
0.25
0.29
0.25
0.29
0.29

GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW

4
4
5
4
4
4
4
5
4
4
5
4
4
4
4
4
5
4
4
4
4
4
4
4
5
4
4
4
5
4

ALTURA
CORDON
SOLDADURA
ACEPTA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

RECHAZA

PROYECTO:
PIE:

CONSECUTIVO LISTA

ALINEAMIENTO
DE LA JUNTA

PRESENTACION
SOLDADURA

ACEPTA

ACEPTA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

RECHAZA

RECHAZA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

ESTAMPE
SOLDADOR

W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P
W-P

4
OBSERVACIONES GENERALES
NOTAS:

RESPONSABLE
FIRMA:
NOMBRES:
CARGO:
FECHA:

Pgina 1 de 1

QA/QC TALLER

INSPECCION VISUAL DE SOLDADURAS

ALFERING S.A.S

FECHA:

CEMEX COLOMBIA

5/28/2016

ESTRUCTURAS TRANSPORTADOR
ESTRUCTURAS
CONSECUTIVO LISTA DE CHEQUEO No:
IDENTIFICACION
DEFECTO

Irregular
-

REPARAD OBSERVACIONES
O
PARTICULARES

si
-

J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 29-05
J-FILETE 29-05
J-FILETE 29-05
J-FILETE 29-05
J-FILETE 29-05
J-FILETE 29-05
J-FILETE 29-05
J-FILETE 29-05
J-FILETE 29-05
J-FILETE 29-05
J-FILETE 29-05
J-FILETE 29-05
J-FILETE 30-05
J-FILETE 30-05
J-FILETE 30-05
J-FILETE 30-05
J-FILETE 30-05
J-FILETE 30-05
J-TOPE 30-05
J-FILETE 30-05
J-TOPE 30-05
J-FILETE 30-05
J-FILETE 30-05
J-TOPE 30-05
J-FILETE 30-05

CC - CLIENTE

V1 - 26/01/2015

IN
## LUGAR:

SANTA MARTA

ORDEN DE TRABAJO:

EMPRESA: ALFERING S.A.S

2497

NOMBRE EQUIPO:
EQUIPO No:
No PLANOS:

CLIENTE:

CEMEX COLOMBIA

ESTRUCTURA TRANSPORTADOR 131-BC-400


MODULO 2-0C
2497-11052016-03

JUNTA

LONG. (ML)

PROCESO

CORDON DE
SOLDADUR
A (mm)

J04
J22
J33
J57

0.80
0.60
0.8
0.29

GMAW
GMAW
GMAW
GMAW

4
5
5
5

ALTURA
CORDON
SOLDADURA
ACEPTA

X
X
X
X

RECHAZA

PROYECTO:
PIE:

CONSECUTIVO LISTA

ALINEAMIENTO
DE LA JUNTA

PRESENTACION
SOLDADURA

ACEPTA

ACEPTA

X
X
X
X

RECHAZA

X
X
X
X

ESTAMPE
SOLDADOR

RECHAZA

W-P
W-P
W-P
W-P

4
OBSERVACIONES GENERALES
NOTAS:

RESPONSABLE
FIRMA:
NOMBRES:
CARGO:
FECHA:

Pgina 1 de 1

QA/QC TALLER

INSPECCION VISUAL DE SOLDADURAS

ALFERING S.A.S

FECHA:

CEMEX COLOMBIA

5/28/2016

ESTRUCTURAS TRANSPORTADOR
ESTRUCTURAS
CONSECUTIVO LISTA DE CHEQUEO No:
IDENTIFICACION
DEFECTO

REPARAD OBSERVACIONES
O
PARTICULARES

si
si
si
si

J-FILETE
J-FILETE
J-FILETE
J-FILETE

27-05
27-05
28-05
29-05

CC - CLIENTE

V1 - 26/01/2015

IN
## LUGAR:

SANTA MARTA

ORDEN DE TRABAJO:

EMPRESA: ALFERING S.A.S

2497

NOMBRE EQUIPO:
EQUIPO No:
No PLANOS:

CLIENTE:

CEMEX COLOMBIA

ESTRUCTURA TRANSPORTADOR 131-BC-400


MODULO 2-0D
2497-11052016-03

JUNTA

LONG. (ML)

PROCESO

J01
J02
J03
J04
J05
J06
J07
J08
J09
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J34
J35
J36
J37
J38

0.25
0.10
0.25
0.29
0.25
0.29
0.29
0.25
0.29
0.11
0.29
0.25
0.11
0.25
0.29
0.29
0.25
0.10
0.25
0.29
0.25
0.29
0.29
0.25
0.29
0.25
0.5
0.6
0.25
0.25
0.6
0.5
0.25
0.29
0.25
0.29
0.3
0.9

GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
FCAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW

CORDON DE
SOLDADUR
A (mm)

ALTURA
CORDON
SOLDADURA
ACEPTA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

RECHAZA

PROYECTO:
PIE:

CONSECUTIVO LISTA

ALINEAMIENTO
DE LA JUNTA

PRESENTACION
SOLDADURA

ACEPTA

ACEPTA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

RECHAZA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

ESTAMPE
SOLDADOR

RECHAZA

C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F

J39
J40

0.9
0.9

GMAW
GMAW

X
X

X
X

OBSERVACIONES GENERALES
NOTAS:

RESPONSABLE
FIRMA:
NOMBRES:
CARGO:
FECHA:

Pgina 1 de 1

QA/QC TALLER

X
4 X

C-F
C-F

INSPECCION VISUAL DE SOLDADURAS

ALFERING S.A.S

FECHA:

CEMEX COLOMBIA

5/28/2016

ESTRUCTURAS TRANSPORTADOR
ESTRUCTURAS
CONSECUTIVO LISTA DE CHEQUEO No:
IDENTIFICACION
DEFECTO

REPARAD OBSERVACIONES
O
PARTICULARES

J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-TOPE 27-05
J-FILETE 27-05
J-TOPE 27-05
J-FILETE 27-05
J-FILETE 28-05
J-TOPE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-TOPE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-TOPE 28-05

J-FILETE 28-05
J-TOPE 28-05

CC - CLIENTE

V1 - 26/01/2015

IN
## LUGAR:

SANTA MARTA

ORDEN DE TRABAJO:

EMPRESA: ALFERING S.A.S

2497

NOMBRE EQUIPO:
EQUIPO No:
No PLANOS:

CLIENTE:

CEMEX COLOMBIA

ESTRUCTURA TRANSPORTADOR 131-BC-400


MODULO 2-0D
2497-11052016-03

JUNTA

LONG. (ML)

PROCESO

J41
J42
J43
J44
J45
J46
J47
J48
J49
J50
J51
J52
J53
J54
J55
J56
J57
J58
J59
J60
J61
J62
J63
J64
J65
J66
J67
J68
J69
J70
J71
J72
J73
J74
J75
J76
J77
J78

0.30
0.30
0.30
0.60
0.90
0.60
0.29
0.29
0.90
0.29
0.60
0.90
0.60
0.60
0.30
0.60
0.60
0.60
0.60
0.29
0.29
0.60
0.50
0.29
0.29
0.60
0.60
0.3
0.9
0.2
0.9
0.9
0.3
0.3
0.9
0.9
0.9
0.3

GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
FCAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW

CORDON DE
SOLDADUR
A (mm)

ALTURA
CORDON
SOLDADURA
ACEPTA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

RECHAZA

PROYECTO:
PIE:

CONSECUTIVO LISTA

ALINEAMIENTO
DE LA JUNTA

PRESENTACION
SOLDADURA

ACEPTA

ACEPTA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

RECHAZA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

ESTAMPE
SOLDADOR

RECHAZA

C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F

J79
J80

0.25
0.1

GMAW
GMAW

X
X

X
X

OBSERVACIONES GENERALES
NOTAS:

RESPONSABLE
FIRMA:
NOMBRES:
CARGO:
FECHA:

Pgina 1 de 1

QA/QC TALLER

X
4 X

C-F
C-F

INSPECCION VISUAL DE SOLDADURAS

ALFERING S.A.S

FECHA:

CEMEX COLOMBIA

5/28/2016

ESTRUCTURAS TRANSPORTADOR
ESTRUCTURAS
CONSECUTIVO LISTA DE CHEQUEO No:
IDENTIFICACION
DEFECTO

REPARAD OBSERVACIONES
O
PARTICULARES

J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-TOPE 27-05
J-FILETE 27-05
J-TOPE 27-05
J-FILETE 27-05
J-FILETE 28-05
J-TOPE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-TOPE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-TOPE 28-05

J-FILETE 28-05
J-TOPE 28-05

CC - CLIENTE

V1 - 26/01/2015

IN
## LUGAR:

SANTA MARTA

ORDEN DE TRABAJO:

EMPRESA: ALFERING S.A.S

2497

NOMBRE EQUIPO:
EQUIPO No:
No PLANOS:

CLIENTE:

CEMEX COLOMBIA

ESTRUCTURA TRANSPORTADOR 131-BC-400


MODULO 2-0D
2497-11052016-03

JUNTA

LONG. (ML)

PROCESO

J81
J82
J83
J84
J85
J86
J87
J88
J89
J90
J91
J92
J93
J94
J95
J96
J97
J98
J99
J100
J101
J102
J103
J104
J105
J106
J107
J108
J109
J110
J111
J112
J113
J114
J115
J760
J77
J78

0.30
0.30
0.30
0.60
0.90
0.60
0.29
0.29
0.90
0.29
0.60
0.90
0.60
0.60
0.30
0.60
0.60
0.60
0.60
0.29
0.29
0.60
0.50
0.29
0.29
0.60
0.60
0.3
0.9
0.2
0.9
0.9
0.3
0.3
0.9
0.9
0.9
0.3

GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW
FCAW
GMAW
GMAW
GMAW
GMAW
GMAW
GMAW

CORDON DE
SOLDADUR
A (mm)

ALTURA
CORDON
SOLDADURA
ACEPTA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

RECHAZA

PROYECTO:
PIE:

CONSECUTIVO LISTA

ALINEAMIENTO
DE LA JUNTA

PRESENTACION
SOLDADURA

ACEPTA

ACEPTA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

RECHAZA

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

ESTAMPE
SOLDADOR

RECHAZA

C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F
C-F

J79
J80

0.25
0.1

GMAW
GMAW

X
X

X
X

OBSERVACIONES GENERALES
NOTAS:

RESPONSABLE
FIRMA:
NOMBRES:
CARGO:
FECHA:

Pgina 1 de 1

QA/QC TALLER

X
4 X

C-F
C-F

INSPECCION VISUAL DE SOLDADURAS

ALFERING S.A.S

FECHA:

CEMEX COLOMBIA

5/28/2016

ESTRUCTURAS TRANSPORTADOR
ESTRUCTURAS
CONSECUTIVO LISTA DE CHEQUEO No:
IDENTIFICACION
DEFECTO

REPARAD OBSERVACIONES
O
PARTICULARES

J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-FILETE 27-05
J-TOPE 27-05
J-FILETE 27-05
J-TOPE 27-05
J-FILETE 27-05
J-FILETE 28-05
J-TOPE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-TOPE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-FILETE 28-05
J-TOPE 28-05

J-FILETE 28-05
J-TOPE 28-05

CC - CLIENTE