DISEO DE MURO DE CONTENCION TIPO I

DATOS:
N Pisos
3.00

1.46 Tn/m2
0.00

SUELO 1 =
1

1.83

Tn/m3

34.23
GM

SUELO 2 =
2

- 0.45

2.06

Tn/m

40.70
GP

- 3.15

Solucion:
Cuando

H=

H =

Cuando

H=

H =
H =

Cuando

H=

H =
H =

0.00
4.38

Tn/m2

0.45
4.38+1.83*0.45*tan2(45-34.23/2)
4.61
Tn/m2
3.15
4.61+2.06*2.70*tan2(45-40.70/2)
5.78

Tn/m2

Grafica :

4.38

E1

E2

4.61

E3
E4
4.61

5.78

Calculo del Eactuante


Fuerza
E1 =
1.97
E2 =
0.05

Long. De giro
Y1 = 2.93

14.52

Y2 = 2.85
Y3 = 1.35

E4 =

1.84

Y4 = 0.90

Eact. =

18.39

E3 =

Calculo del Yponderante

(E*Y)
5.77
0.15

Mact. =

19.60
1.66
27.18

Yponderante =

Yponderante =

27.18

1.48

18.39
Calculo del Eactuante con el Factor de Seguridad
Eact. =

18.39

Eact. =

20.23

Mact. =

27.18

Mact. =

40.16

1.10
Tn

Calculo del Mactuante


1.48
Tn-m

DIMENCIONAMIENTO DE MURO:

concreto =

0.80
2.40

Tn/m

relleno =

1.90

Tn/m3

2.35
5

0.70

1.80

0.80

5.00
CALCULO DEL PESO TOTAL DEL MURO:
ELEMENTO

1.2.3.4.5.Carga actuante =

Peso (Tn.)

Brazo de giro

TOTAL

4.51
5.08
9.60
4.02
7.59
30.80

1.10
2.10
2.50
2.70
4.15

4.96
10.66
24.00
10.85
31.50
Mactuante =

Calculo de la verificacion al FSD - FSV


Verificacion al Deslizamiento
FSD
Verificacion al Volteo
FSV

30.80
20.23

1.52

81.97
40.16

2.04

81.97

CALCULO DE FUERZAS HORIZONTALES:


Ea = Ka *

suelo

* (Htotal)2

dfdfdfdf dfdf2
Calculando ( Ka )
Ka = (tan (45 - /2))2

Ka =

Reemplazando Ka en Ea

Ea =

25.81

0.90

Calculo de Fuerza de Sismo


ELEMENTO
S 1.S 2.S 3.S 4.-

10 % de Peso
0.50
1.07
2.40
0.00

S FUERZA HORIZ.

29.77

VERIFICACION DE LA ESTABILIDAD DEL MURO:


ELEMENTO

PESO (kg)

1.2.3.4.-

BRAZO (mts)

4.96
10.66
24.00

MOMENTO ESTAB. (kg . mt)

1.10
0.70
2.50
3.25

0.00

5.46
7.46
60.00
0.00

S MOMENT. ESTABILIZ.
*

72.92

CALCULO DEL FACTOR AL DESLIZAMIENTO ( FSD )

FSD =

Hr
Ha

W TOTAL * F

S FUERZA HORIZ.

Donde:
F = tang f
F =

tan 32

0.06
NO PASA
F

>

0.60

0.60

Reemplazando F en FSD

FSD

1.65

SI CUMPLE > 1.50

VERIFICACION DEL MOMENTO DE VOLTEO:


ELEMENTO

PESO (kg)

S 1.S 2.S 3.S 4.Ea .-

BRAZO (mts)

0.50
1.07
2.40
0.00
25.81

S MOMENT. VOLTEO
*

MOMENTO VOLT. (kg . mt)

1.98
1.58
0.40
1.98
1.05

0.98
1.69
0.96
0.00
27.10

CALCULO DEL FACTOR AL VOLTEO ( FSV )

FSV =

FSV

S MOMENT. ESTABILIZ.
S MOMENT. VOLTEO
=

2.37

SI CUMPLE > 1.75

30.73

m.

DISEO DE MURO DE CONTENCION TIPO II

DATOS:

SUELO
SUELO
C A

36.00
0.00

kg/cm3

1,630

kg/m3

2,000

kg/m3

DIMENCIONAMIENTO DE MURO:
0.20

1
3

0.60

3.10
CALCULO DEL PESO TOTAL DEL MURO:
ELEMENTO
1.2.3.-

AREA*LONG.
0.84
1.40
9.66

P. ESPECIF.
2,000
2,000
1,630

TOTAL
1,680.00
2,790.00
15,745.80

PESO TOTAL

CALCULO DE FUERZAS HORIZONTALES:


Ea = Ka *

suelo

* (Htotal)2

dfdfdfdf dfdf2
Calculando
( Ka )
Ka = (tan (45 - /2))2
Reemplazando Ka en Ea

Ka =

0.26

20,215.80

Ea

4,581.81

Calculo de Fuerza de Sismo


ELEMENTO
S 1.S 2.S 3.-

10 % de Peso
168.00
279.00
1,574.58

FUERZA HORIZ.

6,603.39

VERIFICACION DE LA ESTABILIDAD DEL MURO:


ELEMENTO

PESO (kg)

1.2.3.-

BRAZO (mts)

1,680.00
2,790.00

MOMENTO ESTAB. (kg . mt)

0.70
1.55
1.95

15,745.80

1,176.00
4,324.50
30,704.31

MOMENT. ESTABILIZ.
*

36,204.81

CALCULO DEL FACTOR AL DESLIZAMIENTO ( FSD )

FSD

Hr
Ha

TOTAL

*F

FUERZA HORIZ.

Donde:
F = tang
F =

tan 32

0.73
OK

>
F

0.60
0.60

Reemplazando F en FSD

FSD

1.84

SI CUMPLE > 1.50

VERIFICACION DEL MOMENTO DE VOLTEO:


ELEMENTO

PESO (kg)

S 1.S 2.S 3.Ea .-

168.00
279.00
1,574.58
4,581.81

BRAZO (mts)

2.55
0.23
2.55
1.55
MOMENT. VOLTEO

CALCULO DEL FACTOR AL VOLTEO ( FSV )

FSV

MOMENTO VOLT. (kg . mt)

= MOMENT. ESTABILIZ.
MOMENT. VOLTEO

428.40
62.78
4,015.18
7,101.80

11,608.16

FSV

3.12

SI CUMPLE > 1.75

O II

4.20

0.45

KG

O ESTAB. (kg . mt)

O VOLT. (kg . mt)