Está en la página 1de 1

RF-45

RF-45
1E1S 1E1S LEYENDA PCI_DETECCION
1E
A2.0.05
A2.0.30 A2.0.31
1E1S 1E1S
A2.0.37 C3.0.01b

RF-45 RF-30

DETECTOR OPTICO DE HUMOS


T
4E
A2.0.02
1E1S T DETECTOR OPTICO HUMOS EN FALSO TECHO
C3.0.04

S DETECTOR OPTICO DE HUMOS EN SUELO


T T
C DETECTOR OPTICO HUMOS EN CONDUCTO
T 1E1S
A2.0.19

RF-45 DETECTOR TERMICO


T A-07

RF-45
RF-30
DETECTOR OPTICO-TERMICO
1E1S F. A. 1E1S
C3.0.08 C3.0.10

1E DETECTOR OPTICO DE LLAMA

RF-90
C3.0.17

1E1SC3.0.07 1E1S PULSADOR DE ALARMA


C3.0.09
T T

1E1S
C3.0.06
1E1S
C3.0.05
T
T 1E1S ALARMA OPTICO-ACUSTICA
A2.0.06d 1E1S
A2.0.23 T T T
1E1S
A2.0.06c

1E1S 4E 1E1S
A2.0.06b A2.0.03
C3.0.15 1E1S 1E
T C3.0.12 MÓDULO DE 1 ENTRADA
1E1S
A2.0.22
1E1S A2.0.20
1E1S
A2.0.21
1E1S
A2.0.06a

1E1S RF-45
1E1S MÓDULO DE 1 ENTRADA Y 1 SALIDA
A2.0.39
1E1S 1E1S
RF-60 1E1S 1E1S C3.0.16
C3.0.11
C3.0.14

A2.0.35

4E MÓDULO DE 4 ENTRADAS

RF-45
RF-90
4E4S MÓDULO DE 4 ENTRADAS Y 4 SALIDAS

RF-30
1E1S
A2.0.32 1E1S 1E1S C3.0.13
A2.0.34
T T
2E/S/L MÓDULO TRANSPONDER

RF-45

RF-30
T
T T T
RF-90 RF-45 RF-45

T T
ELECTROIMÁN RETENEDOR

LETRERO EXTINCIÓN DISPARADA

ALRMA
PRE SIRENA DE PREALARMA EXTINCIÓN
T T T

PULSADOR DE DISPARO EXTINCIÓN

PULSADOR DE BLOQUEO EXTINCIÓN

CDE CENTRAL DE EXTINCIÓN

CENTRAL DE CONTROL Y SEÑALIZACION


T T

F. A. FUENTE DE ALIMENTACIÓN
T T T

RF-30 PUERTA CORTAFUEGO

COMPUERTA CORTAFUEGOS

BIE-25 CON TOMA DE 45

VÁLVULA DE CORTE

TUBERÍA AGUA PCI


T T

T T T SECTOR DE INCENDIO

VIA DE EVACUACION

PARAMENTO ACRISTALADO P.F. PROTEGIDO


POR SISTEMA DE ROCIADORES
AUTOMATICOS

1E1S B2.0.02 T

T T T T T T T T

1E1S 1E1SB2.0.03
B2.0.01

1E1SB2.0.04

1E1S 1E1S
1E1S RF-30 RF-30 1E1S B2.0.12
1E1S B2.0.13
C1.0.13 C1.0.14
B2.0.05 RF-30 RF-30

1E1S
RF-30

B2.0.09
T

T 1E1S
B2.0.14
T

RF-90
1E1S B2.0.06
T

T T T
1E1S
B2.0.10 T
T
T 1E1S
B2.0.17
1E1S B2.0.16
1E1S B2.0.15

1E1S B2.0.07 T T T T T T

Z0NA A1
1E1S
B2.0.11
T 1E1S C1.0.27 1E1S
T C1.0.30
T
Z0NA C3 Z0NA C4
1E1S
1E1S
B2.0.08
1E1S
C1.0.08

Z0NA A2
B1.0.05

T T
1E1S
C1.0.01
RF-60

1E1S 1E1SC1.0.12
C1.0.07 RF-30

1E1S
C1.0.06
1E1SC1.0.11
RF-90

T T

1E1S
B2.0.19 1E1S T T
Z0NA B1 Z0NA B2 Z0NA C1 Z0NA C2
B2.0.18 T

RF-30
T 1E1S C1.0.31

1E1S 1E1S 1E1S


B2.0.25 B2.0.24 B2.0.23 1E1S 1E1S
1E1S
B2.0.22
B2.0.21 B2.0.20

RF-90
RF-30 RF-60
RF-90

F. A. 1E1S
RF-30

C1.0.10
1E1S
C1.0.05
RF-60

1E 02 Revisiones de cambio aceptadas 06/07/2023


T
C1.0.33
1E1S 1E1SC1.0.09
C1.0.04
Cambios aceptados y se incluyen módulos de
T
01 05/07/2023
T T
1E1S
C1.0.03
maniobra
T
1E1S
B2.0.26
T REV. DESCRIPCIÓN CAMBIOS FECHA APROBADO
1E1SC1.0.28
1E1S
C1.0.29
T T T T T T

1E1S
B2.0.27

T T

T
T RF-30

1E1S C1.0.24
RF-30

1E1S C1.0.23
CENTRO TECNOLÓGICO - CTR
CARRETERA EXTREMADURA KM18, MÓSTOLES
T

T
EDIFICIO/BULDING 28935 MADRID
T
T T T
RF-60

RF-90

PCI - DETECCIÓN
ESTADO REFORMA - CTR - PLANTA BAJA
PLANO/PLAN MÓDULO B2
Entreplanta superiror
ES04070T276
T
CÓDIGO PLANO/CODE PLAN IDT
T

16-02-23
000
FECHA/DATE
CTR
XX-XX B2
EXPEDIENTE/EXPEDIENT REF.

Smart Infrastructure
T
Fire & Comfort

EMPRESAS/COMPANIES

FIRMAS/SIGNATURES PROPIEDAD/OWNER

A1
0 1 2 3 4 5
E 1:150
ESCALA/SCALE

También podría gustarte