4%
Número de MPPTs 2
Salida (CA)
Potencia nominal CA 2500W 3000W 3600W 4200W 4600W 5000W 6000W
Potencia aparente máxima 2500VA 3000VA 3600VA 4200VA 4600VA 5000VA 6000VA
Corriente máxima de salida 11.3A 13.6A 16A 19A 20.9A 22.7A 27.2A
Voltaje nominal CA (Rango*) Predeterminado: 240V fase dividida, opcional: 208V & 240V monofásico, 183-228@208V 211-264@240V
Ffrecuencia de red CA (Rango*) 50Hz/60Hz(45-55Hz/59.5-60.5HZ)
Factor de potencia nominal
/ajustable >.99 / +0.8 … -0.8
Eficiencia
Máxima eficiencia 98.2% 98.2% 98.2% 98.4% 98.4% 98.4% 98.4%
Eficiencia europea 97.1% 97.1% 97.2% 97.5% 97.5% 97.5% 97.5%
Eficiencia del MPPT 99.9%
Dispositivos de protección
Protección de polaridad inversa CD Sí
Interruptor CD Sí
Protección contra sobretensión Clase III / Clase II
CA/CD
Protección de corto circuito CA Sí
Protección contra sobtretensión AC Sí
Monitoreo de falla a tierra Sí
Monitoreo de red Sí
Protección anti-isla Sí
Monitoreo de corriente residual Sí
AFCI Sí
Datos generales
Dimensiones 375/350/160mm
Peso 10.8Kg
Rango de temperatura de operación –2 5 ° C . . . + 6 0 ° C
Altitud 4000m
Autoconsumo (noche) <1W
Topología Sin transformador
Enfriamiento Convección natural
Grado de protección IP65
Humedad relativa 100%
CE, IEC62109, G98, G99, VDE0126-1-1, AS4777, AS/NZS 3100, VDE-AR-N4105, CQC, IEC61683,
IEC60068, IEC61727, IEC62116, INMETRO, UL1741,IEEE1547
* El rango de voltaje y frecuencia de CA puede variar dependiendo del estándar de la red del país..
Todas las especificaciones están sujetas a cambios sin previo aviso.
SHENZHEN GROWATT NEW ENERGY CO.,LTD. A: 4-13/F,Building A,Sino-German(Europe)lndustrial Park,Hangcheng Ave,Bao'an District,Shenzhen,China
T: + 86 755 2747 1900 F: + 86 755 2749 1460 E: info@ginverter.com
AUTHORIZATION TO MARK
This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s)
Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing
Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing
Report.
This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be
applied only at the location of the Party Authorized To Apply Mark.
1st East & 3rd Floor, Building 5, 1st East & 3rd Floor, Building 5,
JiayuIndustrial Zone, Xibianling, JiayuIndustrial Zone, Xibianling,
Address: Address:
ShangwuVillage, Shiyan, Baoan ShangwuVillage, Shiyan, Baoan
District,Shenzhen District,Shenzhen
Country: China (Mainland) Country: China (Mainland)
Contact: Woodey Wu Contact: Woodey Wu
Phone: 86 755 27472287 Phone: 86 755 27472287
FAX: 86 755 27472131 FAX: 86 755 27472131
Email: liangcai.wu@ginverter.com Email: liangcai.wu@ginverter.com
Party Authorized To Apply Mark: Same as Manufacturer
Report Issuing Office: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
This document supersedes all previous Authorizations to Mark for the noted Report Number.
This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are
limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned
by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is
restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must
first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the
agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.
Inverters, Converters, Controllers And Interconnection System Equipment For Use With Distributed
Energy Resources [UL 1741:2010 Ed.2+R:15Feb2018]
Interconnecting Distributed Resources With Electric Power Systems (R2008) [IEEE 1547:2003 ]
Standard(s): Amendment 1 to IEEE 1547 - Interconnecting Distributed Resources with Electric Power Systems [IEEE
1547A:2014 ]
Standard Conformance Test Procedures For Equipment Interconnecting Distributed Resources With
Electric Power Systems [IEEE 1547.1:2005 ]
KEY FEATURES
*6BB and MBB products can be provided upon request.
High Voltage
1500 UL and IEC 1500V certowers BOS costs and yields better LCOE
High Efficiency
Higher module conversion efficiency benefit from half cell structure
(low resistance characteristic).
PID Resistance
PID RESISTANT Excellent Anti-PID performance guarantee limited power degradation
for mass production.
0
1 5 12 25
Durability Against Extreme Environmental Conditions
High salt mist and ammonia resistance certified by TUV SUD.
IEC 61215
IEC 61730 25 25-years Linear Performance Warranty
UL 61215
UL 61730
ET SOLAR
support@etsolar.hk
M/ET-PD-EN-US2020V4
ELECTRICAL SPECIFICATIONS
ET-M672BH450WW ET-M672BH445WW ET-M672BH440WW ET -M672BH435WW ET-M672BH430WW
Model Type
ET-M672BH450WB ET-M672BH445WB ET-M672BH440WB ET -M672BH435WB ET-M672BH430WB
9x14
Mounting holes
8places
Ø4
Grounding holes
4places
Current ( A )
7x10
Mounting holes
4places for Nextracker
1300(51.18)
900(35.43)
989(38.94)
3.5x8
Drainage holes
Power ( W )
16places
989(38.94)
Note: the specifications are obtained under the Standard Test Conditons (STCs): 1000 W/m2 solar irradiance, 1.5 Air Mass, and cell temperature of 25℃. The NOCT is obtained under
the Test Conditions: 800 W/m2, 20℃ ambient temperature, 1m/s wind speed, AM 1.5 spectrum.
Please contact support@etsolar. hk for technical support. The actual transactions will be subject to the contracts. This parameters is for reference only and it is not a part of the contracts.
The specifications are subject to change without prior notice.
Attestation of Conformity
No. N8A 108181 0004 Rev. 00
This Attestation of Conformity is issued on a voluntary basis according to the Low Voltage Directive
2014/35/EU relating to electrical equipment designed for use within certain voltage limits. It confirms
that the listed equipment complies with the principal protection requirements of the directive and is
based on the technical specifications applicable at the time of issuance. It refers only to the particular
sample submitted for testing and certification. For details see: www.tuvsud.com/ps-cert
Date, 2020-05-25
( Zhulin Zhang )
Page 1 of 2
After preparation of the necessary technical documentation as well as the EU declaration of conformity the
required CE marking can be affixed on the product. The declaration of conformity is issued under the sole
responsibility of the manufacturer. Other relevant EU-directives have to be observed.
TÜV SÜD Product Service GmbH • Certification Body • Ridlerstraße 65 • 80339 Munich • Germany
Attestation of Conformity
No. N8A 108181 0004 Rev. 00
Parameters:
Construction: Framed with Junction box,
Cable and Connectors.
Test Laboratory: Yangzhou Opto-Electrical
Products Testing Institute
No.10 West Kaifa Road, Yangzhou
225009 Jiangsu, P. R. China
Safety Class: Class II
Maximum System Voltage: 1500 V DC
Fire Safety Class: Class C according to UL790.
Page 2 of 2
After preparation of the necessary technical documentation as well as the EU declaration of conformity the
required CE marking can be affixed on the product. The declaration of conformity is issued under the sole
responsibility of the manufacturer. Other relevant EU-directives have to be observed.
TÜV SÜD Product Service GmbH • Certification Body • Ridlerstraße 65 • 80339 Munich • Germany