Está en la página 1de 1

REPORTE DE TERMOGRAFIA

EQUIPO: PERFORADORA-05 FECHA DE INSPECCION: 5/11/2023

TAG: PER-05 FECHA DE REPORTE: 6/11/2023

MARCA / MODELO: D75KS INSPECCIONADO POR : Gerson Iman

SERIE: 733776 EVALUADO POR: Ruben Huerta

HOROMETRO: 23019 CODIGO DE REPORTE CM-1123-019

EMISIVIDAD 0.95 TEMP. ADMOSFERICA 27°C TEMP. REFLEJADA 17°C DISTANCIA DEL OBJETO 2m

FECHAS
PUNTO DE
COMPONENTE N° ZONAS TERMOGRAMA CONDICION TENDENCIA
3/08/2023 30/08/2023 ALARMA
15/09/2023 29/09/2023 16/10/2023 5/11/2023 30/11/2023

100

50
P1 PTO PRINCIPAL 86.2 68.5 62.8 83.6 85.4 84.3 78.8 95 NORMAL
0
1 2 3 4 5 6 7

100

50
P2 BOMBA ROTACION 68.3 65.6 56.1 64.5 66.8 61.5 64.4 80 NORMAL
0
1 2 3 4 5 6 7

70

60
P3 BOMBA DE AVANCE 66.9 66.6 60.6 67.5 68.8 61.7 62.2 80 NORMAL
50
1 2 3 4 5 6 7

100

CRUCETA DE CARDAN LADO 50


P4 50.7 44.8 33.7 47.2 54.6 45.3 50.7 60 NORMAL
PTO PRINCIPAL
0
1 2 3 4 5 6 7

100

CRUCETA DE CARDAN LADO 50


P5 50.9 48.6 52.8 63.7 50.8 46.9 60 NORMAL
PTO SECUNDARIO
0
1 2 3 4 5 6 7

100

50
P6 PTO SECUNDARIO 71 67 59.4 72.8 82.3 75 72.7 85 NORMAL
0
1 2 3 4 5 6 7

70
65
60
P7 BOMBA DE TRASLACION RH 65 63.2 59.3 67.3 68.4 61.5 80 NORMAL
55
50
1 2 3 4 5 6 7

100

50
P8 BOMBA DE TRASLACION LH 63.4 60.4 64.3 70.2 72.7 66.5 80 NORMAL
0
1 2 3 4 5 6 7

100

CRUCETA DE CARDAN LADO 50


P9 57 39.7 27.7 57.2 68.7 43.6 60 NORMAL
PTO SECUNDARIO
0
1 2 3 4 5 6 7

60
40
CRUCETA DE CARDAN LADO
P10 44.7 38.4 25 40.7 49.9 40.4 60 NORMAL 20
MOTOR
0
1 2 3 4 5 6 7

110
100
P11 MOTOR ZONA FRONTAL 99.3 90.7 88 87.6 90.3 87.7 95 NORMAL 90
80
1 2 3 4 5 6 7

110
105
100
P12 MOTOR ZONA DELANTERA 104.7 102.5 98.2 102.7 103.3 98.3 105 NORMAL 95
90
1 2 3 4 5 6 7

110
100
P13 MOTOR ZONA POSTERIOR 87.6 101.8 101.6 101.7 100.4 94.4 105 NORMAL 90
80
1 2 3 4 5 6 7

80
70
COMPRESOR ZONA
P14 64.3 62.6 62.7 65.5 73.5 66.2 80 NORMAL 60
DELANTERA
50
1 2 3 4 5 6 7

80
70
COMPRESOR ZONA CENTRAL
P15 60.4 69.2 64.4 64.6 70.6 59.3 80 NORMAL 60
DELANTERA
50
1 2 3 4 5 6 7

90
80
COMPRESOR ZONA CENTRAL
P16 76.9 78.6 72.7 73.9 82.8 74.1 95 NORMAL 70
POSTERIOR
60
1 2 3 4 5 6 7

100

COMPRESOR ZONA 50
P17 64.9 67.2 57.2 66.2 73 62.4 95 NORMAL
POSTERIOR
0
1 2 3 4 5 6 7

90
80
P18 CODO DE COMPRESOR 82.1 82.8 74.2 73 82.3 72.8 105 NORMAL 70
60
1 2 3 4 5 6 7

80

19.1 MOTOR DE VENTILADOR 70


72.2 70 66.9 71.4 76.7 69.5 80 NORMAL
DE ENFRIAMIENTO
60
1 2 3 4 5 6 7
P19
100
19.2 REDUCTOR DE
50
VENTILADOR DE 63.5 57.8 56.1 63 68.5 59.7 80 NORMAL
ENFRIAMIENTO 0
1 2 3 4 5 6 7

60
40
P20 CABEZAL 33.4 27.4 27.4 40.3 44.8 70 NORMAL 20
0
1 2 3 4 5 6 7

CONCLUCIONES Y RECOMENDACIONES
* Temperaturas en condiciones normales.
*Continuar con el monitoreo de temperatura para evaluar las tendencias.

También podría gustarte