LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD

VP - 100 (0.25 x 0.45m) VP - 100 (0.25 x 0.45m) VP - 100 (0.25 x 0.45m) VS-100(0.20 x 0.20m) VP - 100 (0.25 x 0.45m)

LÍMITE DE PROPIEDAD
VP - 100 (0.25 x 0.45m)
VP - 100 (0.25 x 0.45m)

VP - 100 (0.25 x 0.45m)


LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD

1.00 .60 .60 1.00 1.00 .60 VP - 100 (0.25 x 0.45m) VS-100(0.20 x 0.20m)

VP - 100 (0.25 x 0.45m)


2.80

VP - 100 (0.25 x 0.45m)


1.00 .60

3.37
A

VP - 100 (0.25 x 0.45m)

VP - 100 (0.25 x 0.45m)

BIFAMILIAR
VB-100(0.20 x 0.20m)

VP - 100 (0.25 x 0.45m)

VP - 100 (0.25 x 0.45m)


VB-100(0.15 x 0.20m)

VIVIENDA
VP - 100 (0.25 x 0.45m) VP - 100 (0.25 x 0.45m)
VP - 100 (0.25 x 0.45m)

VP - 100 (0.25 x 0.45m)


.60 .60 .60 .60 .60 .60

VP - 100 (0.25 x 0.45m)


VB-100(0.20 x 0.20m)
VB-100(0.20 x 0.20m) .60 .60 .60 .60 VB-100(0.20 x 0.20m) 1.50

VP - 100 (0.25 x 0.45m)

LÍMITE DE PROPIEDAD
VP - 100 (0.25 x 0.45m)

V - 100 (0.25 x 0.20m)


VP - 100 (0.25 x 0.45m)

VB-100(0.20 x 0.20m)
LÍMITE DE PROPIEDAD

2.89
VP - 100 (0.25 x 0.45m)

VB-100(0.20 x 0.20m)

2.55
2.89

.60 .60 .60

2.45
VS-100(0.20 x 0.20m) VP - 100 (0.25 x 0.45m) VP - 100 (0.25 x 0.45m) VS-100(0.20 x 0.20m)

.60 .60 .60


LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD

3.45 2.35 3.72 1.90 2.25 3.90

VS-100(0.20 x 0.20m) VS-100(0.20 x 0.20m) VP - 100 (0.25 x 0.45m) VP - 100 (0.25 x 0.45m) VS-100(0.20 x 0.20m)
LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD LÍMITE DE PROPIEDAD

LOSA ALIGERADA AZOTEA


3.45 2.75 3.32 1.90 2.25 3.90

LOSA ALIGERADA 1ER Y 2DO, PISO


DETALLES GENERALES
DETALLE DE VIGAS
ESC: 1/25 ESCALA 1/25

L/3 L/3 L/3

.05
m

2 Ø 3/8" adicional

GANCHO ESTÁNDAR, EXTENSIÓN MÍNIMA.


2Ø5/8"+1Ø1/2"

.20
.15
ldh RADIO MÍNIMO DE DOBLADO PARA BARRAS Losa h=.20

.15
H .30
AOG
AOG

PROYECTO:
.05 Doblez de 180° Doblez de 90°
.30
m
db D (cm) 2Ø5/8" Losa h=.20
REFUERZO ADICIONAL EN NUDOS
.05 A o G (cm) J(cm) A o G (cm) 1Ø1/2" Losa h=.20
L/4 L/4 L/4 L/4
DE VIGA SOBRE VIGA
L
3/8" 6.0 12.5 8.0 15.5 .45
CHATAS (ALIGERADOS) PERALTADAS 1/2" 8.0 15.5 10.5 20.0

.10
5 cm (min)

NOTA:
5/8"
3/4"
9.5
11.5
18.0
20.5
13.0
15.5
25.0
30.0 .25
.20 .10 .30
ANCLAJE TÍPICO DE VIGAS
a). No empalmar más del 50% del área total en una 1" 15.5 27.5 20.5 42.5
misma sección
1" 2Ø5/8"+1Ø1/2"
b). En caso de no empalmarse en las zonas indicadas
Varilla a Empalmar
r r 2Ø5/8" 1Ø1/2"
r r
ó con los porcentajes especificados aumentar la Ø DE COLUMNA,
Longitud detallada
.25
.40
AoG o PLACA Ø DE COLUMNA,

longitud de empalme en un 30% o consultar al contratista. 1"


o PLACA

b). En toda la longitud del empalme se deben colocar


f'c=210 kg/cm2 a .20
LONGITUD DE DESARROLLO
db

estribos de 3/8" @ 0.10 Varilla a Empalmar

PARA GANCHOS ESTÁNDAR


j

D
VALORES DE m
db D (cm) ldh (cm)
4Ø1/2" 4Ø5/8"+2Ø1/2" 2Ø1/2"
DETALLE TIPICO DE ALIGERADO
REFUERZO INFERIOR REFUERZO SUPERIOR 3/8" 6.0 15.0 4d o 6 cm (min)
PROPIETARIOS
DIÁMETRO Ø
H CUALQUIERA H<.30 H≥.30 1/2" 8.0 16.0 Ø3/8":1@.05, 2@.10,3Ø.15, r@.20 c/ext. Ø3/8":1@.05, 2@.10,3Ø.15, r@.20 c/ext. 1/4"Ø1@.20
3/8" .40 .40 .55
DISTANCIA LIBRE MÍNIMA ENTRE 5/8"
3/4"
9.5
11.5
20.0
24.0 Longitud detallada
. CASTILLO MARQUINA
1/2" .55 .55 .75 VARILLAS Y RECUBRIMIENTO
1" 15.5 31.0 VIGA VS- 100 (.25x.25) VIGA VP- 100 (0.25x0.45) VIGA VB (.15x.25)
5/8" .70 .70 .95 NOTA: Ø r(cm.) a(cm.)
FELIX
db

-La separación libre de refuerzo longitudinal entre dos


Puesto que el gancho debe estar embebido en concreto
3/4"

1"
.80

1.15
.80

1.15
115

1.50
(2) capas es de 1".
-La tolerancia máxima admisible en la colocación del
refuerzo en capas será de 0.5cm
confinado, los coeficientes 0.7 (por recubrimiento de
concreto) y 0.8 (por estribos) se han incorporado en la
ecuación del artículo 8.5.1
Ao G
D

12 db
1/4"

3/8"
1.3

2.0
6.5

10.0
VIGA VS- 201 (.25x.25) VIGA VP- 201 (0.25x0.45) . GARCIA RUIZ
DETALLE DE EMPALME POR TRASLAPE
EN VIGAS, LOSAS y ALIGERADOS En Muros
1/2" 2.5 13.0
VIGA VS- 301 (.25x.25) VIGA VP- 301 (0.25x0.45) CLAUDIA
ESCALA: 1/25 Ø 6mm,
.40 .40 TODAS LAS JUNTAS DETALLE DE DOBLADO DE ESTRIBOS
.25 INTERCALADAS DETALLE REMATE DE REFUERZO EN COLUMNAS Y VIGAS UBICACION
.13

T.PVC Ø 4"
LONGITUDINAL EN COLUMNAS Y PLACAS DETALLES DE ELEMENTOS
.30 .30
DE ARRIOSTRES ESPECIFICACIONES GENERALES PROGRAMA DE VIVIENDA
AoG

.13
135

T.PVC Ø 2" 3db Máx.


6d
°

b
ó
7.

1.NORMAS DE DISEÑO ANDRES RAZURI PROGRAMA


5c

ESCALA: 1 / 25
m

m H/3
(

in T.PVC Ø 4" o 2" 3db Máx.


DETALLES EN PLANTA -Norma Técnica de Edificación E-010
.)

Le
.05 -Norma Técnica de Edificación E-020
EMADI-PERU
H CA-1 ZONA B MZ. K1 LOTE 18
D 2 Ø 6mm,
@ 3 HILADAS H2/3H .15
.20
-Norma Técnica de Edificación E-030
Ø Le(m)
Altura Máx. de Tabique: 1.50m
-Norma Técnica de Edificación E-050 TRUJILLO
Longitud detallada

Le Longitud Máx. entre Arriostres verticales: 3.00m


3/8" .40 -Norma Técnica de Edificación E-060 - Modificada 08 Mayo del 2009
1/2" .45
Muro de Ladrillo
Arriostre vertical
-Norma Técnica de Edificación E-070
H/3

5/8" .55 VI 2.CONCRETO


GU
-CONCRETO ARMADO EN:

.13

.13
ET
3db Máx.
3/4" .65 A
Colocar zuncho alrededor de
tubo con alambre Nº16@.03mts .25 .45
ZAPATAS f'c=210 Kg/cm² PROFESIONAL
1" 1.20
db Ø1/4"@2 hiladas VIGAS DE CIMENTACIÓN f'c=210 Kg/cm²
DETALLE DE REFUERZO POR PASO LA f'c=210 Kg/cm²
GANCHO SÍSMICO NOTA.- Alternar los empalmes en D 4 Ø 3/8" VIGAS
DE TUBERÍAS DE INSTALACIONES diferentes pisos y empalmar 30 RIL Conexión a ras estr. Ø 1/4": 1 a .05,
EMPALME DE REFUERZO VERTICAL como máximo 50% del refuerzo
DETALLE DE JUNTA DE DILATACION x 3 LO LOSAS f'c=210 Kg/cm² ING:
db D (cm) A o G (cm) H aprox(cm) ESC: 1/25
SIN ESCALA 0 x DE 2 @ .10, 2@.15 rto. @ .25 c/ext.
EN COLUMNAS Y PLACAS DE PÓRTICOS DÚCTILES 15 COLUMNAS f'c=210 Kg/cm²
3/8" 4.0 11.0 8.0
1/2" 5.0 11.5 8.0 COLUMNETAS Y VIGUETAS f'c=175 Kg/cm²
5/8" 6.5 14.0 9.5 (Arriostres verticales con 2 apoyos simples) f'c=175 Kg/cm²
3/4" 11.5 20.5 11.5
DETALLE TÍPICO ISOMETRICO DE ESCALERA
1" 15.5 27.0 15.5 - CONCRETO CICLÓPEO EN:
LOSA ALIGERADA h=.20m CA-2
- CIMIENTO CORRIDO

CONFINAMIENTO MURO (1º al 2º piso) SECUENCIA CONSTRUCTIVA


Altura Máx. de Tabique: 2.50m
Longitud Máx. entre Arriostres verticales: 2.00m
- Resistencia del concreto de la matriz f’c = 100 kg/cm2
ESC. 1/25 1.- Colocación de acero en la base de la columneta. - La piedra desplazadora no excederá del 30% del volumen total de concreto
2.- Anclaje de acero en la viga. Muro de Ladrillo ciclópeo y será colocada de manera homogénea, debiendo quedar todos sus bordes
Arriostre vertical
3.- Colocación de acero de la columneta. embebidos en el concreto.
0.40 0.40 PLANO:
0.30 0.30
VIGA

.13

.13
4.- Asentado de ladrillo del muro.
- La mayor dimensión de la piedra desplazadora no excederá de la mitad de
5.- Colocacion de acero de la vigueta. .25 .45 la menor dimensión del elemento ni será mayor de 25 cm.
Ø1/4"@2 hiladas
6.- Baseado de concreto de la columneta.
2 Ø 6mm 4 Ø 1/2" -Se utilizara cemento Tipo MS, para las subestructura, columnas del primer nivel y
7.- Baseado de concreto en la vigueta.
2 Ø 6mm C/3 HILADAS Longitud Longitud
Conexión a ras estr. Ø 1/4": 1 a .05,
2 @ .10, 2@.15 rto. @ .25 c/ext.
losas deportivas, y cemento tipo I para la superestructura ALIGERADO
C/3 HILADAS Viga ó Losa
-RECUBRIMIENTOS:
(Arriostres verticales con 2 apoyos simples) -ZAPATAS 7.5 cm.
-COLUMNAS Y VIGAS QUE FORMAN PÓRTICOS 4.0 cm.
Sellar junta con Sellante Elástico o similar Sellar junta con Sellante Elástico o similar
CA-3 -COLUMNAS Y VIGAS DE ARRIOSTRAMIENTO 2.5 cm.
Altura Máx. de Tabique: 3.00m
-LOSAS (Aligeradas y Macizas) 2.0 cm.
3.ACERO
max..50

Longitud Máx. entre Arriostres verticales: 2.00m


2
Separación interior 1"

2 22
.53 Muro de Ladrillo - BARRAS DE CONSTRUCCIÓN ASTM A615, GRADO 60 ESCALA :
Arriostre vertical
S/C 100-(0.15x0.45) - PERFILES Y PLACAS ASTM A36
0.40 0.40 SOBRE CIMIENTO - ANCLAJES Y PERNOS DE FIJACIÓN ASTM A36 1 / 50

.13

.13
f'c=175kg/cm2 NTN= ± 0.00 0.45
0.45
4 Ø 12 mm 8 mm 5 .25 .45
1@0.05m,rst@0.15 c/extr
7 Ø1/4"@2 hiladas 4.MAMPOSTERÍA
4 Ø 1/2" -LADRILLO LADRILLO TIPO IV DE 23x13x9
Conexión a ras estr. Ø 1/4": 1 a .05,
-MORTERO 1:4 (CEMENTO:ARENA) FECHA :
2 @ .10, 2@.15 rto. @ .25 c/ext.
CIMIENTO 5.CIMENTACIÓN
0.40 1:10 + 30% PG
3 (Arriostres verticales con 2 apoyos simples) PRESIÓN ADMISIBLE JULIO - 2023
Altura

1.05
-CIMENTACIÓN SUPERFICIAL σad= 0.854 Kg/cm²
0.90
4 4 PROFUNDIDAD DE CIMENTACIÓN
6 -CIMENTACIÓN SUPERFICIAL Df = 1.60 m, Respecto al nivel mas bajo NTN
2 Ø 6mm DETALLES EN ELEVACIÓN
0.30 0.30
C/3 HILADAS
1.40
VA-1 6.SOBRECARGAS
PLANO N°
Junta de CARGA VIVA DE PISO : 300 kg/m2
Construcción Arriostre horizontal CARGA VIVA DE 2do TECHO : 100 kg/m2
.53

Viga ó Losa
.20

Falso Cimiento 0.50 0.50 NOTA:

E-02
(1/10 + 30% P.G.) EL CONTRATISTA DEBE VERIFICAR EN OBRA LAS DIMENSIONES FINALES DE LA ESTRUCTURA DE
1 CONCRETO ANTES DE PROCEDER A LA FABRICACIÓN DE LA ESTRUCTURA DE MADERA. EL
FABRICANTE DE LOS COMPONENTES METÁLICOS GARANTIZARA LA CALIDAD DE LA SOLDADURA
Muro de Ladrillo
ANCLAJE EN EXTREMOS ANCLAJE COLUMNA .25 King Kong o
Pandereta
POR MEDIO DE PRUEBAS NO DESTRUCTIVAS, EN UN PORCENTAJE NO MENOR AL 10%, ESTE
PORCENTAJE SERÁ ELEGIDO ALEATORIAMENTE POR EL SUPERVISOR. EL COSTO DE ESTAS
.13
EN CIMIENTO 1 PRUEBAS DE CALIDAD SERÁN POR CUENTA DEL FABRICANTE, PARA LA FABRICACIÓN DE LOS
ESC. 1/25 COMPONENTES METÁLICOS EL FABRICANTE DEBERÁ USAR OPERARIOS CALIFICADOS
4 Ø 3/8"
estr. Ø 1/4": 1 @ .05, DEBIDAMENTE ACREDITADOS CON LOS CERTIFICADOS CORRESPONDIENTES, EN CASO QUE EL
DETALLES EN ELEVACIÓN DE ELEMENTOS DE ARRIOSTRE. 4 @ .10, rto. @ .25 c/ext. SOLDADOR NO CUENTE CON LA ACREDITACIÓN DEBERÁ APROBAR UNA "ESPECIFICACIÓN DE
ESCAL A : 1 / 25
PRUEBA DE SOLDADORES" QUE SERÁ VERIFICADA POR EL SUPERVISOR.