Está en la página 1de 1

A B C A B C A B C ESPECIFICACIONES TECNICAS

D D D
Junta Sísmica Junta Sísmica Junta Sísmica
e = 3cm e = 3cm e = 3cm
Junta Sísmica Junta Sísmica Junta Sísmica
e = 3cm e = 3cm e = 3cm
9 9 9 9 9 9

Piscina
F.M.
Terraza

8 03 02 01 Ø 3/4"PVC
8 8 8 8 8
F.M.

LEYENDA AGUA
7 7 7 7 7 7
Junta Sísmica

Junta Sísmica
e = 3cm

LLEGA ALIM. A.C. e = 3cm


M

CPVC Ø 1/2" DE LA therma

CPVC Ø 1/2" DE LA therma

CPVC Ø 1/2" DE LA therma


LLEGA Y BAJA ALIM. A.C.

LLEGA Y BAJA ALIM. A.C.


Zona de Parrilla
Sala Dormitorio 04 Ø 1/2"CPVC

Dormitorio 03
Ø 1/2"PVC

Ø 3/4"PVC
Comedor

Ø 3/4"PVC
Ø 1/2"CPVC
Ø 1/2"CPVC

6 6 6 6 6 6

.25
Ø 1/2"CPVC
Ø 1/2"PVC

Cocina Ø 1/2"CPVC Azotea

Ø 1/2"CPVC
Ø 3/4"PVC
LLEGA ALIM. A.C.

Ø 1/2"CPVC
Ø 1/2"CPVC
Ø 1/2"PVC
CPVC Ø 1/2" DE LA therma Ø 1/2"CPVC
Jardín Therma
Hall Baño eléctrica SOMBRERO DE VENTILACION

LLEGA TUB. DE IMPULSION 3/4" PVC


Ø 1/2"CPVC

Ø 3/4"PVC
Ø 1/2"PVC

LLEGA Y BAJA ALIM. A.C.


CPVC Ø 1/2" DE LA therma LLEGA TUB. DEL T.E. 3/4" REBOSE 2"
Ø 1/2"PVC
recorrido por losa aligerada Y DISTRIBUYE A
PISOS INFERIORES

5 Ø 1/2"PVC
5 5 Ø 1/2"PVC
5 5 Ø 3/4"PVC
5

Ø 1/2"CPVC
LLEGA ALIM. A.F. LLEGA Y BAJA ALIM. A.F. LLEGA Y BAJA ALIM. A.F.
17 16 15 14 Ø133/4" PVC DEL T.E. 17 16 15 14 13Ø 3/4" PVC DEL T.E. 34 33 32 31 30Ø 3/4" PVC DEL T.E.

Dormitorio 02
12 12 29
LLEGA ALIM. A.C. LLEGA Y BAJA ALIM. A.C.
CPVC Ø 1/2" DE LA therma 11 CPVC Ø 1/2" DE LA therma 11 28 TUB. DE VENTILACION 2" PVC
10 10 27
Dorm. Principal 09 09 T.E. 26
Ø 1/2"CPVC
NIV. ARRANQUE BRECHA DE AIRE
08 25 25
REJILLA
07 24 24

06 23 23

Ø 1/2"CPVC
Azotea
Ø 1/2"CPVC

01 02 03 04 05 18 19 20 21 22 18 19 20 21 22
BAJA AGUA FRIA
LLEGA ALIM. A.F. LLEGA Y BAJA ALIM. A.F. LLEGA Y BAJA ALIM. A.F. LLEGA TUB. DEL T.E. 3/4" Ø 3/4" PVC LIMPIEZA 2"
Ø 3/4" PVC DEL T.E. Ø 3/4" PVC DEL T.E. Ø 3/4" PVC DEL T.E. Y DISTRIBUYE A
PISOS INFERIORES

4 Ø 1/2"PVC
4 4 Ø 1/2"PVC 4 4 Ø 3/4"PVC 4
Dormitorio 01 Ø 1/2"CPVC

Ø 1/2"CPVC
Ø 1/2"CPVC

SUBE AL T.E.
Ø 1/2"CPVC
Ø 1/2"CPVC

LOSA DE AZOTEA
Baño Baño

Ø 1"PVC
Ø 1/2"PVC
Azotea
Ø 1/2"CPVC

DETALLE DE TANQUE ELEVADO


Ø 1/2"PVC

Ø 1/2"PVC
Ø 1/2"CPVC

Ø 1"PVC

3 3 3 3 3 3
Ø 1"PVC

Ø 1/2"PVC Ø 1/2"PVC
SUBE TUBERIA IMPULSION PVC

LLEGA Y SUBE TUBERIA IMPULSION PVC

LLEGA Y SUBE TUBERIA IMPULSION PVC


Ø 1" AL TANQUE ELEVADO

Ø 1" AL TANQUE ELEVADO

Ø 1" AL TANQUE ELEVADO


2 2 2 2 2 2
Junta Sísmica

Junta Sísmica

Garaje
e = 3cm

e = 3cm
Ø 1"PVC

Jardín
Ø 1"PVC
Ø 3/4"PVC

1 1 1 1 1 1
Junta Sísmica Junta Sísmica Junta Sísmica
e = 3cm Junta Sísmica e = 3cm Junta Sísmica e = 3cm Junta Sísmica
e = 3cm e = 3cm e = 3cm

A B A B A B
M

C D C D C D DETALLE DE INSTALACION
SEGUNDO e
lvN
i AZO
EA
T
VIENE DE LA RED

DE CALENTADOR ELECTRICO
M
PRIER
PUBLICA Ø 3/4"

1
0 e
lvN
i 2
0 05 : 1 a l ac s e 05 : 1 a l ac s e
ESC. 1:25
05 : 1 a l ac s e

0.15

02

03

0.55 0.55 01 05 04
0.47 0.47 0.21 0.21 06 PROPIETARIO:
06
0.15 0.15 RAÚL EDUARDO SALGUERO POLICIO

PROYECTO: Lamina: N°
VIVIENDA UNIFAMILIAR
0.305
Plano :
DETALLE - APARATOS SANITARIOS
IS-01
DETALLE N°02 INSTALACIONES SANITARIAS - AGUA
NICHO EN MURO PARA ALOJAR VALVULAS
DETALLE TIPICO DE VALVULA INSTALADA EN VERTICAL Profesional Responsable:
ESC. = 1 / 25 ESFÉRICAS Esc: 1/50 Fecha: DICIEMBRE 2022

Diseño: Departamento: Provincia: Distrito: Ubicación:


INGENIUS LIMA CAÑETE CERRO AZUL HAB. URB. PLAYA LOS LOBOS MZ. F LOTE 2

También podría gustarte