Está en la página 1de 1

N

E
9.18
S
1.20 0.43 0.75 1.70 1.21 1.20 2.30 0.40 ÑO

1
1
1 0.25
VC-101 (0.25x0.40)
VC-101 (0.25x0.40)
VC-101 (0.25x0.40)
1 0.45
1.20 1
1.20 1 ESPECIFICACIONES TÉCNICAS

VC-101 (0.25x0.40)
1.20 1
ARQUITECTURA + INGENIERIA + CONSTRUCCION
H = 0.60 ZAPATAS, COLUMNAS Y VIGAS Contactanos :
H = 0.60 Z2 F'C=210 KG/CM2 CEL. 931306163 - 936955914
a.crear.sac@gmail.com
H = 0.60 Z9

VC-101 (0.25x0.40)
a.crear.sac@hotmail.com
FY=4200 KG/CM2

0.05
Z2 3.19

VC-101 (0.25x0.40)
2

2
CIMIENTO

12 Øb 12 Øb
2.78 2.43 CONCRETO CICLOPEO 1/10+30%

3
1.21

1
1

1
H = 0.60 H = 0.60
Z8 Z8 SOBRECIMIENTO
H = 0.60
Z2 2 2
6.48 FALSO PISO

b
VC-101 (0.25x0.40) VC-101 (0.25x0.40)
CONCRETO SIMPLE 1/6
2 0.25 1.20 1.70 1.70 0.25
RECUBRIMIENTOS
LOSAS, ALIGERADOS Y VIGAS CHATAS 2CM
2 2
1.70 1.70
COLUMNAS Y VIGAS PERALTAS
ANCHO > .25 3 CM

1
VC-101 (0.25x0.40)

VC-101 (0.25x0.40)
ANCHO < .15 2 CM

VC-101 (0.25x0.40)
VC-101 (0.25x0.40)

2 ZAPATAS SOBRE SOLADO O FALSA ZAPATA 5 CM

2
3.04 2.79 a SOBRE SUELO 8 CM
MUROS CARA CONTACTO TERRENO /AGUA 4 CM
H = 0.60 H = 0.60
CARA OPUESTA 3 CM
4.04
3.24
Z8 Z8
1.70
1.70
F'M= 45 KG/CM2
TIPO DE LADRILLO II
1

2' 1.70 VC-101 (0.25x0.40) 1.70 0.25 0.25

1.20

0.40
1

1
1.25
H = 0.60
ESPECIFICACIONES DE MATERIALES

VC-101 (0.25x0.40)
Z5

VC-101 (0.25x0.40)
VC-101 (0.25x0.40)

1.87
3 0.25 0.90 VC-101 (0.25x0.40)
2

2
CEMENTO: POTLAND TIPO I
AGUA: POTABLE
0.30 H = 0.60 H = 0.60
H = 0.60 H = 0.60 ARENA: LIMPIA
Z7 Z7 0.25
3

1.30
1.65
Z4 Z4 PIEDRA:

2 2 2

0.60
4 0.45 1.80 2.00 2.00 1.80 0.45 ACERO: ASTM A 513 (PERFILES RECTANGULARES Y CUADRADOS)
VC-101 (0.25x0.40) VC-101 (0.25x0.40) VC-101 (0.25x0.40)
ASTM A 36 (PLANCHAS)
20.03
PERNOS DE CONEXION: ACERP GRADO 5 O ASTM A 325
2 2 2 PERNOS DE ANCLAJE: ACERO ASTM 36
19.47

2.00 2.00 1.20


1.20
VC-101 (0.25x0.40)

4
VC-101 (0.25x0.40)

5.15 4.70 3.35 3.35 4.70

0.20
0.15 0.15 0.15 0.15
4

Ver cuadro de columnas

MURO

MURO

MURO

MURO
1.20 1.20
Terreno natural Terreno natural Terreno natural Terreno natural
H = 0.60 H = 0.60 H = 0.60 H = 0.60

SOBRECIMIENTO
0.100.10

0.100.10

0.100.10

0.100.10

0.100.10
Z4 Z7 Z7 Z4 Falso Piso Falso Piso Falso Piso Falso Piso Falso Piso Falso Piso

SOBRECIMIENTO
SOBRECIMIENTO

SOBRECIMIENTO
Afirmado Afirmado Afirmado Afirmado Afirmado Afirmado

0.50
2 2 2

0.65
0.70

0.70

0.70
5 0.45 1.80
VC-101 (0.25x0.40) 2.00 VC-101 (0.25x0.40) 2.00 VC-101 (0.25x0.40)
1.80 0.45

1.25
0.90

CIMIENTO CORRIDO
1.05

VC-102
2 2 2

0.60
1.70

1.70

1.70
VC-101

VC-101
VC-101 (0.25x0.40)
VC-101 (0.25x0.40)

0.40

0.40

0.40
1.80

0.60
1.50

1.50
1.60

2.00
1

2.00

CIMIENTO CORRIDO
3

2.80 2.35 2.36

CIMIENTO CORRIDO

CIMIENTO CORRIDO
1.30 1.30
1.60
1.60 0.40
Ver cuadro de zapatas
1

0.60

0.60

0.60

0.60

0.60
H = 0.60 H = 0.60 L
H = 0.60 H = 0.60
Z2 Z6 Z6 Z2 SECCIÓN 3-3
2 2
2
0.10

0.10
SOLADO 0.40 0.40 0.40
6 0.45 1.20
VC-101 (0.25x0.40) 1.60 VC-101 (0.25x0.40)1.60 VC-101 (0.25x0.40)
1.20 0.44
a

SECCIÓN 1-1 SECCIÓN 2-2 SECCIÓN 4-4


2 2
VC-101 (0.25x0.40)

VC-101 (0.25x0.40)

VC-101 (0.25x0.40)

VC-101 (0.25x0.40)

2 ZAPATAS (Típica)
1

1.20
0.78
2

2.45 1.18 1.90


2.10 H = 0.60
1

H = 0.60 H = 0.60 Z2
H = 0.60 Z3 Z3
Z1 1 1 1 1.20
1.00 1.00
0.80
0.45
7 0.25 VC-101 (0.25x0.40) VC-101 (0.25x0.40) VC-101 (0.25x0.40)

0.80 1 1.52 1.60 1 1.16 1.60 1 1.27 1.20

0.25 2.75 2.51 2.89

0.25 0.25 0.25


9.15

3.00 2.76 3.17

A B C D

CIMENTACIÓN
ESC. 1/50

E-01

También podría gustarte