DISEÑO ZAPATA DE COLUMNA ELE BLOQUE A

0.66
1.- Columna Ancho (m)= 0.5 0.5 Area requerida
Largo (m)= 0.66

Cargas Pcm (tn)= 30.5 Mcm (tn*m)= 0.54


2.- Pcv (tn)= 4.7 Mcv (tn*m)= 0.08
Pcs (tn)= 23.98 Mcs(tn*m)= 35.79

Suelo σ (kg/cm2)= 2.8


Concreto F'c(kg/cm2)= 210 Pc(kg/m3)= 2400 Peso especifico del concret
Acero Fy(jg/cm2)= 4200
Profundidad Df (m) = 1.80

Solucion Dimensionamiento % = 5% Pcm

Estatico P(tn)= 35.200 P  pcm  pcv


M (tn*m)= 0.620 M  mcm  mcv
Pzap(tn)= 1.760
Ptotal (tn) = 36.960
A.Zapata A.zap(m2) = 1.320 Ptotal
Asap 
Largo = 1.50 m
σ
Ancho= 1.50 m
Area = 2.25 m2

σ1(tn/m2)= 15.64444444 <= 28 ok pasa

Dinamico
P(tn)= 59.180 P  pcm  pcv  pcs
M (tn*m)= 36.410 M  mcm  mcv  mcs
Pzap(tn)= 2.959 Ptotal
Asap 
Ptotal (tn) = 62.139 σ
A.Zapata A.zap(m2) = 2.22

Largo = 1.50 m
Ancho= 1.50 m
Area = 2.25 m2

Medidas criticas de zapata


Area mayor= 2.25 m2 M (tn-m)= 0.620
Largo (m) = 1.50 P (tn) = 36.960
Ancho (m)= 1.50

Verificacion de presiones
M
Excentricidad= 0.02 m Exc. 
P
Corregir el eleccionario del caso
σ1(tn/m2)= 17.529
σ2(tn/m2)= 15.324

 1  1 . 3 t
17.53 <= 36.4 Cumple ok ad

Verificacion del peso propio de la Zapata

h(m)= 0.50 Ancho (m)= 1.500


Largo (m) = 1.50 Pc(kg/m3)= 2400.000

Peso real(tn)= 2.700 Diferencia(tn)= 0.94


P.Anterior(tn)= 1.760

Verificacion de presiones

P(tn)= 35.200
M (tn*m)= 0.620
Pzap(tn)= 2.700
Ptotal (tn) = 37.900
A.zap(m2) = 1.354

Exentricidad= 0.0164
Verificacion

Corregir el eleccionario del caso


σ1(tn/m2)= 16.668
σ2(tn/m2)= 14.621

σ (kg/cm2)= 2.8 si cumple


σ (tn/m2)= 28.0

 1  1 . 3 t
16.67 <= 36.4 Cumple ok ad

Cargas Amplificadas
Estatico Pu  1.5 (pcm  ppzap)  1.8 pcv
Pu= 58.3
Mu  1.4 mcm  1.7 mcv
Mu= 0.9
Excent (m) = 0.0153 e  Mu/Pu
L/6= 0.250 L/6 e  L/6

Verificacion
P  6*e 
Caso 01=
e
L σ 12
 * 1 
B*L  L 

6
Caso 02= 2* P
e 
L
6
σ 1

B*L σ 2
0
Caso 03= L 2 * P
e 
6 σ 1

 L 
3 * B *   e
 2 

Puede variar el valor de l/6

Resumen
1.- σ1(tn/m2)= 27.47911111 2.- σ1(tn/m2)= 0
Estatico σ2(tn/m2)= 24.30755556 Dinamico 01 σ2(tn/m2)= 0
σ1(tn/m2)= 71.14666667 Valores escogidos
σ2(tn/m2)= 71.14666667

Chequeo por punzonamiento

Según el reglamento la zona de punzonamiento


1.50
Zapata largo (m) = 1.5 1.50
Ancho (m) = 1.5

Columna largo (m) = 0.66 0.5


Ancho (m) = 0.5
0.66
D= 0.4
d/2 xxx= 0.2 m
d/2 yyy= 0.2 m
largo (m) = 1.5
X0(cm)= 106 Ancho (m) = 1.5
Y0(cm)= 90 Az= 2.25
A0(cm2)= 9540 Area nucleo Aext.= Az-A0= 1.73
B0= 392 Perimetro L.col A0= 0.52
β c= 1.32 βc 
A.col

El cortante a la distancia "d/2" de la cara de la columna


Vu (tn) = 123.0837 Tn
Vc (Tn) = 309.783
φ = 0.75

Vu <= Vc
1.1
123.083733 <= 263.316 ok Vc  (0.53  ) f' c * bo * d
βc
Diseño por cortante
Calculamos a una distancia de la cara de la columna
vc   * 0 .53 * f 'c * b * d
Vu (tn)= 1.4229
φ = 0.75 luego    Vu   vc    ok
Vc(tn) = 12.96072507737

Vu <= Vc
1.42293333 <= 12.961 ok

Diseño por Flexion

El momento al lado de la cara

Cuantia maxima para F´c 210 = 0.0162


Ku maximo F´c 210 = 49.5300
Diseño
Datos Base= 100 cm
Peralte= 50.00 cm VOLADO
Momento= 6.28 Ton*m m(m) 0.42
F'c= 210 Kg/cm^2
Fy= 4200 Kg/cm^2

Recubrimiento= 10 cm
b 1= 0.85
f= 0.9
d´= cm
d efectivo = 40.00 cm
Ku = 3.922
A.acero.min= 9.00 cm^2
A. acero requer. 6.00 cm^2

Tenemos
p= 0.0015
As (cm^2)= 9.000
As φ 5/8" 1.99 elegir acero
s= 0.2211 uso ø 5/8" @ 0.20 m
E BLOQUE A

Area requerida

Peso especifico del concreto

mcv  mcs
58.26 tn

Estatico 0.892 tn-m

Cargas Amplificadas
p)  1.8 pcv Diamico 01
0.5 Pu= 71.355 Pu  1.25 (pcm  ppza
Mu= 36.565 Mu  1.25( mcm  mcv
27.48 24.31 Excent (m) = 0.512
e  L/6 L/6= 0.250

Verificacion
σ1(tn/m2)= 27.48 Caso 01= L
σ2(tn/m2)= 24.31 e
6
σ 2
0
σ1(tn/m2)= 0
Caso 02=
e 
L
6
σ2(tn/m2)= 0 Caso 03= L
e 
6
σ1(tn/m2)= 0
σ2(tn/m2)= 0

3.- σ1(tn/m2)= -53.35111


σ2(tn/m2)= 71.14667 Dinamico 02
m
m
m2
m2
m2

* bo * d
71.36 tn

Dinamico 01 36.565 tn-m

Cargas Amplificadas

Pu  1.25 (pcm  ppzap  pcv)  ps 0.5


Mu  1.25( mcm  mcv )  mcs
e  Mu/Pu 0.00 0.00
L/6 0 e  L/6

P  6* e  σ1(tn/m2)= 0
σ 12
 * 1 
B*L 

L  σ2(tn/m2)= 0

σ 1

2* P
B*L σ 2
0 σ1(tn/m2)= 0
2*P σ2(tn/m2)= 0
σ 1

L 
3*B*  e
 2  σ1(tn/m2)= 0
σ2(tn/m2)=
20.02 tn

Dinamico 02

Cargas Amplificadas
Dinamico 02
Pu= 20.020 Pu  1.5 (pcm  ppzap)  1.8 pcv
Mu= -35.015 Mu  1.25( mcm  mcv )  mcs
Excent (m) = -1.749 e  Mu/Pu -53.35
L/6= 0.250 L/6 e  L/6

Verificacion
Caso 01= L P  6*e  σ1(tn/m2)= -53.351111
e
6 σ 12
 * 1 
B*L 

L  σ2(tn/m2)= 71.146667
Caso 02= L
e 
6 σ 1

2* P
B*L σ 2
0 σ1(tn/m2)= 0
Caso 03= L 2*P σ2(tn/m2)= 0
e 
6 σ 1

L 
3*B *  e
 2  σ1(tn/m2)= 0.000
σ2(tn/m2)= 0
-35.015 tn-m

0.5

71.147