4 5 6 7 8 9 10 11

A B
ER-HW-SEC-10 ER-HW-SEC-10
L-10a L-10a L-10a
L-10a L-10a
L-10a
D D
L-10a

L-10a L-10a

L-10a L-01 L-01 L-01 L-01 L-01 L-01 L-01

E E
Manager Office
NFC: 2.95
E2412

L-01 E L-01 L-01 E L-01 L-01 E L-01 L-01 E L-01 L-01 E L-01 L-01 L-01

12KBTU/H
L-04
Work Points
73pax
L-01 L-01 L-01 L-01 L-01 E2403 L-01 L-01 L-01 L-01 L-01 L-01 E
L-10a L-10a
NFC: 2.94
E 36KBTU/H E
L-04
60KBTU/H
F L-04 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01
F
Huddle Space Huddle Space
E2418 60KBTU/H 60KBTU/H 60KBTU/H E2419 L-10a
L-10a
L-04
NFC: 2.75

NFC: 2.75

L-10a
L-10a
D L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a D
NFC: 2.75
ER-HW-SEC-20 E E E E E E ER-HW-SEC-20
L-10a
60KBTU/H
E

NFC: 2.76
L-10a
L-08a L-01 L-01
12KBTU/H L-01 L-01
E
L-10a
Small Meeting
Small Meeting

24KBTU/H
Room 6pax
Room 4pax
E2407
36KBTU/H 36KBTU/H
NFC: 2.95
E2408
NFC: 2.94
L-08a
L-01 L-01
NFC: 2.76 NFC: 2.76
L-01 L-01
L-10a

E
L-08a L-10a
Training Room
20pax
E
G E2406
G
L-10b L-10b L-10b
L-08b L-03
E

12KBTU/H
L-10a

L-03

L-03
L-04
L-08a L-10a

L-03

L-03
L-10b L-10b

Large
18KBTU/H
L-03 NFC: 2.90 Conference
Room 17pax
LEYENDA DE AGUA HELADA
L-10b L-10b L-10a L-10a L-10a
18KBTU/H

L-03

L-03
E2404

60KBTU/H
L-03

L-03

E E L-04
NFC: 2.75

L-10b L-10b BLOQUE DESCRIPCIÓN


Medium Meeting Welcome area
E2401

L-03

L-03
Room 9pax
NFC: 2.40
E2405
L-03

L-03

L-10a
NFC: 2.90 RED DE AGUA HELADA EXISTENTE.
E

12KBTU/H
L-10a

L-03

L-03
L-10a L-10a
12KBTU/H
L-04
L-03

L-03

E L-10b L-03
18KBTU/H

E L-10b
L-10b
NFC: 2.75 RED DE AGUA HELADA REUBICADA.
L-03
L-10b
Mother room
NFC: 2.75 L-10a E2414 L-10a Proyecto:
H L-10a
NFC: 2.74
Small Meeting
H
L-10a Room 4pax RED DE AGUA HELADA NUEVA. REMODELACIÓN HUAWEI
E2410
E L-01 L-01

L-01 L-01 L-01 L-01


NFC: 2.94
24KBTU/H

24KBTU/H
L-10b
12KBTU/H
12KBTU/H
VÁLVULA DE PURGA Dirección:
Manager Office NFC: 2.95

E2413
NFC: 2.94
L-10a Av. Las Begonias 415 - San
L-02 Small Meeting
E
L-10a Room 6pax
Isidro - Pisos 22, 23 y 24
L-01 L-01 Huddle Space E2409 L-01 L-01
L-01 L-01
E2417
L-10bNFC: 2.40
L-10b
NOTAS DE INSTALACIÓN
L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a
36KBTU/H
Huddle Space
L-10a
E E E E E E E E2416 La válvula de purga se coloca al final de la tubería de retorno
L-10a
Tipo de plano:
NFC: 2.75
Coffee Reading
Area NFC: 2.75
PLANO DE AGUA HELADA
E2415
L-10a L-10a L-10a PISO 24
60KBTU/H 60KBTU/H 60KBTU/H 60KBTU/H
NFC: 2.75
L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 Fecha 21/03/2023
Escala 1:100 Formato lámina A1
I L-10a I Nombre de Archivo IM-02 AGUA HELADA

NFC: 2.94
L-10a Diseñador: Alejandro Garrido López
C L-10a
C Ingeniero Mecánico:
E
L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 E L-01 Sandro Salas Vela CIP: 199188
ER-HW-SEC-20 ER-HW-SEC-20
L-10a 12KBTU/H
Work Points
73pax
E2402
Título y fecha revisado
L-01 E L-01 L-01 E L-01 L-01 E L-01 L-01 E L-01 L-01 E L-01 L-01 L-01 NFC: 2.94 L-01

Manager Office
E2411

J J
L-10a L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-10a

L-10a Cliente: Ingeniero Mecánico


Sandro Salas Vela
K K
L-10a L-10a Huawei
L-10a
CIP: 199188
L-10a L-10a

A
B
ER-HW-SEC-10
ER-HW-SEC-10 3G Office
Avenida Alberto del Campo 409, Of. 503
Lima, Perú
Teléfono +51 1 399 6331
www.3g-office.com
4 5 6 7 8 9 10 11
EUROELEC PERÚ SAC
Avenida Alberto del Campo 409, Of. 503
Lima, Perú
Teléfono +51 965485947
www.euroelecperu.com

Los diseños gráficos, las imágenes, los planos, las fotografías, los textos, así
como la información y los contenidos que se recogen en el presente
documento están protegidos por la legislación peruana sobre los derechos
de propiedad intelectual e industrial a favor de 3g office Perú S.A.C. y no
se permite su reproducción y/o publicación, total o parcial, ni su
tratamiento informático, su distribución, su difusión, ni su modificación,
transformación, ni demás derechos reconocidos legalmente a su titular,
sin el permiso previo y por escrito del mismo, 3g office Perú S.A.C. Cada
documento o plano puede detallar una disciplina particular por lo que
deberá ser siempre considerado dentro del conjunto de la
documentación completa, verificando su adecuada coordinación con
ésta. Asimismo el contratista responsable deberá cotejar siempre en
obra las dimensiones y especificaciones reales de cualquier elemento
con el que pudiese interferir lo expresado en el proyecto. En el supuesto
de discrepancias entre documentos, se instará a lo que resuelva la
Dirección facultativa. Las posibles omisiones, o incoherencias detectadas
entre la distinta documentación, deberán ser motivo de inmediata
consulta a la Dirección Facultativa; de lo contrario se entenderá que la
documentación aportada se comprende y resulta suficiente para el fin al
que se destina.

IM-02