Documentos de Académico
Documentos de Profesional
Documentos de Cultura
ID DE MEDIA COMPLEJIDAD DEL PROYECTO RECUPERACIÓN DE LA CONFIABILIDAD DEL SISTEMA DE AGUA DE CALDERAS DE
PROYECTO: LA U-031 DE LA REFINERÍA DE CARTAGENA
3007567-ODS 068
HOJA DE DATOS TRANSMISORES DE FLUJO - PLATINA DE No. PROYECTO
NOMBRE DOCUMENTO:
ORIFICIO
CÓDIGO: 031-DS-IC08-0302
INSTRUMENTACIÓN
ID DE MEDIA COMPLEJIDAD DEL PROYECTO RECUPERACIÓN DE LA CONFIABILIDAD DEL SISTEMA DE AGUA DE CALDERAS DE LA U-031
PROYECTO: DE LA REFINERÍA DE CARTAGENA
. CONTENIDO
Pág.
FT-3001 3
FE-3001 4
FT-3002 3
FE-3002 4
FT-3003 3
FE-3003 4
FT-3004 3
FE-3004 5
FT-3005 3
FE-3005 5
FT-3006 3
FE-3006 5
FT-3007 3
FE-3007 6
FT-3008 3
FE-3008 6
FT-3009 3
FE-3009 6
FT-3010 3
FE-3010 7
FT-3011 3
FE-3011 7
FT-3012 3
FE-3012 7
ID DE MEDIA COMPLEJIDAD DEL PROYECTO RECUPERACIÓN DE LA CONFIABILIDAD DEL SISTEMA DE AGUA DE CALDERAS DE LA U-031 DE LA
PROYECTO: REFINERÍA DE CARTAGENA
No. PROYECTO 3007567-ODS 068
NOMBRE DOCUMENTO: HOJA DE DATOS TRANSMISORES DE FLUJO PLATINA DE ORIFICIO
CÓDIGO: 031-DS-IC08-0302
ID DE MEDIA COMPLEJIDAD DEL PROYECTO RECUPERACIÓN DE LA CONFIABILIDAD DEL SISTEMA DE AGUA DE CALDERAS DE LA U-031
PROYECTO: DE LA REFINERÍA DE CARTAGENA
Flow measurement at exchanger FF- Flow measurement in discharge Flow measurement steam to
2. Service
E2551A / Bypass FF-E2551A head 031-SP-P-100A/B/C/D deaereators 031-SP-DH-100 / 101
4. Pipe Size / Schedule / Rating 6" / 10S / 150# 8" / 10S / 150# 20" / STD / 150#
5. Pipe material TP 304/304L Stainless Steel TP 304/304L Stainless Steel Killed Carbon Steel
12. S.G. operating 0.995 0.995 0.999 0.994 0.967 0.964 0.983 0.983 0.983
OPERATING
13. Flow density, lb/ft3 (@ Oper) 62.03 62.03 62.03 62.02 60.3 60.12 0.075 0.075 0.075
CONDITIONS
14. Viscosity, cP @ Tmin 0.718 0.718 0.015
22. Type Square edge concentric orifice Square edge concentric orifice Square edge concentric orifice
24. Orifice Bore Diameter 3.94" (Note 1) 5.2" (Note 1) 12.37" (Note 1)
32. Weld Standard ASME B31.3 Normal Service ASME B31.3 Normal Service ASME B31.3 Normal Service
33. Meter Connection - Type Flange tap Flange tap D and D/2 tapping
37. Type of meter Differential Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter
38. Differential Range - Dry -250 a 250 in H2O -250 a 250 in H2O -100 a 100 in H2O
METER
39. Static pressure range / Rupture Limit 0-1000 / 3000 psig 0-1000 / 3000 psig 0-1000 / 3000 psig
(see previous page)
40. Temperature sensor No No No
NOTES:
1. Supplier shall be include the certificate of materials and confirm the plate thickness and orifice plate calculations to guarantee its proper operation according to process conditions.
2. Instrument shall have a permanently attached nameplate in 304 S.S stamped with following information: P.O. Number, Identification TAG.
3. The supplier must supply the orifice plate, the transmitter and support.
4. Vendor shall supply each flange with one taps 1/2 in FNPT according to Reficar piping class
5. By vendor list Ecopetrol GAB-P-022.
ID DE MEDIA COMPLEJIDAD DEL PROYECTO RECUPERACIÓN DE LA CONFIABILIDAD DEL SISTEMA DE AGUA DE CALDERAS DE LA U-031
PROYECTO: DE LA REFINERÍA DE CARTAGENA
HOJA DE DATOS TRANSMISORES DE FLUJO PLATINA DE No. PROYECTO 3007567-ODS 068
NOMBRE DOCUMENTO:
ORIFICIO CÓDIGO: 031-DS-IC08-0302.01
4. Pipe Size / Schedule / Rating 4" / XS / 600# 4" / XS / 600# 4" / XS / 600#
5. Pipe material Killed Carbon Steel Killed Carbon Steel Killed Carbon Steel
9. Flow Rate, US GPM Min. Norm. Max. 208 245 288 208 245 288 208 245 288
10. Temperature, ºF 252 252 252 252 252 252 252 252 252
11. Pressure, psig 991 957 891 991 957 891 991 957 891
12. S.G. operating 0.942 0.942 0.942 0.942 0.942 0.942 0.942 0.942 0.942
OPERATING
CONDITIONS 13. Flow density, lb/ft3 (@ Oper) 58.73 58.73 58.73 58.73 58.73 58.73 58.73 58.73 58.73
15. Max. Differential Pressure 100 inH2O 100 inH2O 100 inH2O
22. Type Square edge concentric orifice Square edge concentric orifice Square edge concentric orifice
24. Orifice Bore Diameter 2.75" (Note 1) 2.75" (Note 1) 2.75" (Note 1)
PRIMARY ELEMENT 28. Flange Rating 600# (Note 4) 600# (Note 4) 600# (Note 4)
32. Weld Standard ASME B31.3 Normal Service ASME B31.3 Normal Service ASME B31.3 Normal Service
33. Meter Connection - Type Flange tap Flange tap Flange tap
37. Type of meter Differential Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter
38. Differential Range - Dry -250 a 250 in H2O -250 a 250 in H2O -250 a 250 in H2O
METER
(see previous page) 39. Static pressure range / Rupture Limit 0-1000 / 3000 psig 0-1000 / 3000 psig 0-1000 / 3000 psig
NOTES:
1. Supplier shall be include the certificate of materials and confirm the plate thickness and orifice plate calculations to guarantee its proper operation according to process conditions.
2. Instrument shall have a permanently attached nameplate in 304 S.S stamped with following information: P.O. Number, Identification TAG.
3. The supplier must supply the orifice plate, the transmitter and support.
4. Vendor shall supply each flange with one taps 1/2 in FNPT according to Reficar piping class.
5. By vendor list Ecopetrol GAB-P-022.
ID DE MEDIA COMPLEJIDAD DEL PROYECTO RECUPERACIÓN DE LA CONFIABILIDAD DEL SISTEMA DE AGUA DE CALDERAS DE LA U-031
PROYECTO: DE LA REFINERÍA DE CARTAGENA
HOJA DE DATOS TRANSMISORES DE FLUJO PLATINA DE No. PROYECTO 3007567-ODS 068
NOMBRE DOCUMENTO:
ORIFICIO CÓDIGO: 031-DS-IC08-0302.01
5. Pipe material Killed Carbon Steel Killed Carbon Steel Killed Carbon Steel
9. Flow Rate, US GPM Min. Norm. Max. 208 245 288 208 245 288 208 245 288
10. Temperature, ºF 252 252 252 252 252 252 252 252 252
11. Pressure, psig 991 957 891 991 957 891 991 957 891
12. S.G. operating 0.942 0.942 0.942 0.942 0.942 0.942 0.942 0.942 0.942
OPERATING
CONDITIONS 13. Flow density, lb/ft3 (@ Oper) 58.73 58.73 58.73 58.73 58.73 58.73 58.73 58.73 58.73
15. Max. Differential Pressure 100 inH2O 100 inH2O 100 inH2O
22. Type Square edge concentric orifice Square edge concentric orifice Square edge concentric orifice
24. Orifice Bore Diameter 2.75" (Note 1) 2.75" (Note 1) 2.75" (Note 1)
PRIMARY ELEMENT 28. Flange Rating 600# (Note 4) 600# (Note 4) 600# (Note 4)
32. Weld Standard ASME B31.3 Normal Service ASME B31.3 Normal Service ASME B31.3 Normal Service
33. Meter Connection - Type Flange tap Flange tap Flange tap
37. Type of meter Differential Pressure Transmitter Differential Pressure Transmitter Differential Pressure Transmitter
38. Differential Range - Dry -250 a 250 in H2O -250 a 250 in H2O -250 a 250 in H2O
METER
39. Static pressure range / Rupture Limit 0-1000 / 3000 psig 0-1000 / 3000 psig 0-1000 / 3000 psig
(see previous page)
40. Temperature sensor No No No
NOTES:
1. Supplier shall be include the certificate of materials and confirm the plate thickness and orifice plate calculations to guarantee its proper operation according to process conditions.
2. Instrument shall have a permanently attached nameplate in 304 S.S stamped with following information: P.O. Number, Identification TAG.
3. The supplier must supply the orifice plate, the transmitter and support.
4. Vendor shall supply each flange with one taps 1/2 in FNPT according to Reficar piping class.
5. By vendor list Ecopetrol GAB-P-022.
ID DE MEDIA COMPLEJIDAD DEL PROYECTO RECUPERACIÓN DE LA CONFIABILIDAD DEL SISTEMA DE AGUA DE CALDERAS DE LA U-031
PROYECTO: DE LA REFINERÍA DE CARTAGENA
4. Pipe Size / Schedule / Rating 4" / XS / 600# 8" / XS / 600# 6" / XS / 150#
5. Pipe material Killed Carbon Steel Killed Carbon Steel Killed Carbon Steel
9. Flow Rate, US GPM Min. Norm. Max. 208 245 288 514 980 1442 185 346 1008
11. Pressure, psig 991 957 891 927 943 874 171 166 154
12. S.G. operating 0.942 0.942 0.942 0.942 0.942 0.942 0.995 0.995 0.995
OPERATING
CONDITIONS 13. Flow density, lb/ft3 (@ Oper) 58.73 58.73 58.73 58.73 58.73 58.73 62.03 62.03 62.03
15. Max. Differential Pressure 100 inH2O 150 inH2O 200 inH2O
22. Type Square edge concentric orifice Square edge concentric orifice Square edge concentric orifice
24. Orifice Bore Diameter 2.75" (Note 1) 5.5" (Note 1) 4.125" (Note 1)
PRIMARY ELEMENT 28. Flange Rating 600# (Note 4) 600# (Note 4) 300 # (Note 4)
32. Weld Standard ASME B31.3 Normal Service ASME B31.3 Normal Service ASME B31.3 Normal Service
33. Meter Connection - Type Flange tap Flange tap Flange tap
NOTES:
1. Supplier shall be include the certificate of materials and confirm the plate thickness and orifice plate calculations to guarantee its proper operation according to process conditions.
2. Instrument shall have a permanently attached nameplate in 304 S.S stamped with following information: P.O. Number, Identification TAG.
3. The supplier must supply the orifice plate, the transmitter and support.
4. Vendor shall supply each flange with one taps 1/2 in FNPT according to Reficar piping class.
5. By vendor list Ecopetrol GAB-P-022.