2 STOPPER 1 1
66
3@200=600 185
SEALING MATERIAL
80 B12 6
185
1050
2200
240 B12
630
7
3 3
295
1050
DOWEL BAR 32@250, L=900
200
136
370
63
B25 2 3 B16 3 B32 1 B32 1a 2 32 8
785
2 1 1
2000 10000
600 1400 12000
14000
14000
ELEVATION DOWEL BAR LOCATION
PLAN
STOPPER
1100 1100
335 430 335 335 430 335
3 B12 3 B12
7 7
185
340
3@200=600 185
6 6 6a 1b
600
30
7 B32 1 7 B32 1
2 B12 2 B12
150
5 5 B10
200 200
1050
11
3 3 B16 3 B16 3 3 B16 3 B16
865
3 3 2 B10
300 150
14 B10
12
3 4 B16 4 B16 3 3 4 B16 4 B16 3
15
14 B20
136
B12
30 70 13
17 B25 2 17 B25 2
4 B16 4 B16
63
REINFORCEMENT SUMMARY
NO. SKETCH DIAMETER LENGTH QUANTITY WEIGHT NOTES NO. SKETCH DIAMETER LENGTH QUANTITY WEIGHT NOTES NO. SKETCH DIAMETER LENGTH QUANTITY WEIGHT NOTES
(mm) (mm) (kg) (mm) (mm) (kg) (mm) (mm) (kg)
50x50x6
9 9a 476
ANGLE STEEL
249
50 1 13900 32 13900 7 614 6 12 1201 160 171 11 10 600 15 6
600
13868 476
1012
750
750
1868
750
750
2 8 900 14 1600 20
15
plain bars
1000
1000
226
226
0 ISSUED FOR CONSTRUCTION 2021-05-10 Zhang Yong Chang Zhanwei Wu Zhefeng NOTES: PROJECT: DRAWING TITLE: SCALE :
CLIENT: DESIGNER : A1: 1:20
F For Revision 2020-10-20 Zhang Yong Chang Zhanwei Wu Zhefeng 1. THE REBAR TO REBAR'S POSITION IS MEDIUM TO MEDIUM, THE REBAR TO CONCRETE POSITION'S IS MEDIUM TO EDGE.
2.ALL DIMENSIONS ARE IN MILIMETERS .
A3: 1:40
E For Revision 2020-09-21 Zhang Yong Chang Zhanwei Wu Zhefeng
D For Revision 2020-08-18 Zhang Yong Chang Zhanwei Wu Zhefeng 3.THE COVER OF REINFORCEMENT IS 50mm. Chancay Multipurpose Terminal New First Stage, Peru Reinforcement Drawing For A-RMG DATE :
C Adjust the Size of Track Beam Slot 2020-04-09 Zhang Yong Chang Zhanwei Wu Zhefeng 4. MAIN REINFORCING STEEL SHALL HAVE MINIMUM YIELD STRENGTH OF 450MPA. 2021-05-10
中远海运港口秘鲁钱凯公司 2020-03-20 Zhang Yong Chang Zhanwei Wu Zhefeng 5.THE CONCRETE STRENGTH OF LAND STRUCTURES SHALL BE 32MPA IN CYLINDER CHARACTERISTIC STRENGTH Detailed Engineering Track Beam 04
COSCO SHIPPING Ports Chancay PERÚ S.A. CCCC Water Transportation Consultants Co.Ltd B For Revision CODE : REVISION:
AND 40 MPA IN CUBE CHARACTERISTIC.
Rev. DESCRIPTION DATE BY. CKD. APD. AUD.
The Ports for ALL 6.THE EMBEDDED PARTS ARE FOR REFERENCE ONLY, THE SPECIFIC SIZE IS DETERMINED ACCORDING TO THE DATA PROVIDED BY THE MANUFACTURER. P114143-E-000-RY-DWG-012-R0 R0
REVISIONS