Está en la página 1de 1

RESERVA

RESERVA

RESERVA

POZO DE TIERRA CON ELECTEODO VERTICAL

N.T.N.

0.60

0.30
0.40
0.10
DIAGRAMA UNIFILAR TABLERO GENERAL DE DISTRIBUCION (TGD)
CONDUCTOR DE Cu.
SISTEMA NORMAL
(DEL TIPO EMPOTRADO, 220V, 60HZ)
DESNUDO 70mm2 01 CONECTOR DEL TIPO A PRESION
POR CUÑA PARA 3/4"Ø CON 70mm2
TABLERO TGD NORMAL
18 POLOS + 5 INT. DIFERENCIAL

2x20A 2x25A
C-1 30mA 2-1x2.5mm2 LSOH-90 +1x2.5mm2 LSOH-90(T)+ 20mmØ PVC-P
ALUMBRADO
CONDUCTOR DE Cu.
2-1x2.5mm2 LSOH-90 +1x2.5mm2 LSOH-90(T)+ 20mmØ PVC-P DESNUDO 70mm2
LUZ DE EMERGENCIA SOLDADURA
2x25A EXOTERMICA
2x50A
2x25A RELLENO CON TERRENO DE CULTIVO,
C-2 30mA 2-1x4mm2 LSOH-90 +1x4mm2 LSOH-90(T)+ 20mmØ PVC-P
2-1x10mm2 LSOH-90 +1x10mm2 LSOH-90(T) +25mmØ PVC-P 10KA TSG CERNIDA Y COMPACTADA EN
2x30A
2x30A 2x40A
2x40A CAPAS DE 150mm
C-3 30mA
30mA 2-1x4mm2 LSOH-90 +1x4mm2 LSOH-90(T)+ 20mmØ PVC-P
TD 1

2x30A 2x40A 3.00


C-4 30mA 2-1x4mm2 LSOH-90 +1x4mm2 LSOH-90(T)+ 20mmØ PVC-P
TD 2

2x30A 2x40A
C-5 30mA 2-1x4mm2 LSOH-90 +1x4mm2 LSOH-90(T)+ 20mmØ PVC-P
TD 1 -2PISO CEMENTO CONDUCTIVO
2x30A 2x40A
2-1x4mm2 LSOH-90 +1x4mm2 LSOH-90(T)+ 20mmØ PVC-P
ALREDEDOR DE VARILLA IGUAL O
C-6 30mA
TD 2- 2PISO EQUIVALENTE A ERICO GEM25A
C-7 RESERVA (02 BOLSAS)

C-8
RESERVA

VARILLA DE PUESTA A TIERRA COBRE


DE 19mm (3/4") x 2400mm (8') DE

PODER DE RUPTURA 6 KA

SALVO INTERRUPTOR PRINCIPAL

DIAGRAMA UNIFILAR TABLERO DE DISTRIBUCION (TD1,2)


SISTEMA NORMAL
(DEL TIPO EMPOTRADO, 220V, 60HZ)

TABLERO TGD NORMAL


18 POLOS + 5 INT. DIFERENCIAL

2x20A 2x25A
C-1 30mA 2-1x2.5mm2 THW-90 +1x2.5mm2 THW(T)-90+ 25mmØ PVC-P
ALUMBRADO

2-1x2.5mm2 THW-90 +1x2.5mm2 THW(T)-90+ 20mmØ PVC-P


LUZ DE EMERGENCIA
2x25A 2x25A
2x30A C-2 30mA 2-1x4.0mm2 THW-90 +1x4.0mm2 THW(T)-90+ 20mmØ PVC-P
2-1x6mm2 THW-90 +1x6mm2 THW-90(T) 10KA TOMACORRIENTE
+25mmØ PVC-P
2x16A 2x25A
C-3 30mA 2-1x2.5mm2 THW-90 +1x2.5mm2 THW(T)-90+ 25mmØ PVC-P
CALENTADOR

2x16A 2x25A
C-4 2-1x2.5mm2 THW-90 +1x2.5mm2 THW(T)-90+ 25mmØ PVC-P
TOMACORRIENTE COCINA

C-5 RESERVA

C-6
RESERVA

C-7 RESERVA

C-8
RESERVA

TDG 1 PODER DE RUPTURA 10 KA

SALVO INTERRUPTOR PRINCIPAL

Salida Terma

Tablero de distribución

Interruptor

Tomacorriente alto
2.10
1.80

1.20
Tomacorriente Normal
1.20

0.40
NPT
CAJA PASE TV,INTERNET
INTERCOMUNICADOR
ALTURAS REFERENCIALES DE INSTALACION DE SALIDAS (S/E)

LLEGA ALIMENTADORES
PARA TD PISOS SUPERIORES

LLEGA TOMA TSG

17

16
15
14 LEYENDA
13
12
11
10
09
08
07
06
05
04
03 CL
ESPECIFICACIONES TECNICAS
02
01
6 MEDIDORES INTERNOS

TG y TSG

TDG 1
LEYENDA J Y M
SOLUCIONES EN CONSTRUCCIÓN E.I.R.L

TELF: (01) 7341816


INTERCOMUNICADOR CEL: 935872369
CORREO:
JYMSOLUCIONESENCONSTRUCCIÓN@GMAIL.COM

PLANTA 1° PISO PROFESIONAL


RESPONSABLE
DIBUJO PROPIETARIO
JULIO ERNESTO JULCA GARCIA
PLANO:

R.B.L
ESC. 1 / 50 INGENIERO:
UBICACION: PROYECTO
FEIDER PAVEL

IE-01
BRINGAS ENCISO UNIDAD DE VIVIENDA- MULTIFAMILIAR
CIP N° 138328 Mz. G07 LOTE 9,
ESPECIALIDAD
URB. SANTA MARIA
ELECTRICAS
2DA ETAPA
TOMACORRIENTE, TV,INTERNET Y CABLE
DISTRITO
CARABAYLLO-LIMA FECHA: ESCALA:

SETIEMBRE 2020 1/50