Está en la página 1de 1

DIAGRAMA - RED DE GAS

Q=2,379.19m3/h
E2

Q=622.59 m3/h
G2B
Q=1,
074.1
2 m3
/h
G

Q=1,452.72 m3/h

Tramo GA2-1
M2

L=147.9 m
2"
Q=2,096.77 m3/h
O1

Q=3,174.76 m3/h
Tramo G2A-A2

L 57 G1-1
Tram

Tramo M1-M2
L=181.3 m

=
2"
2"

L=334 m
G2A

Tramo E1-E2

0.34
A2

2"
L=759.5 m
Q=1,377.49 m3/h

m
2"
Q1
Q=2,075.31 m3/h
1

Tramo G2-GA2

Q=1,127.04 m3/h
L=362.29 m
Q=311.3 m3/h Tramo M1-1 1
1 L=106.6 m

2"
M1 2"

Tramo G3-1
L=233.62 m

Tramo O-O1
L=602.2 m
2"

Tramo G4-1

2"
L=81.81 m

Tramo N1-1
L=470.5 m
2"

2"
Q=4,265.48 m3/h
Q=413.89 m3/h
Tramo E-1

Tramo M-M1
Tramo G1-G2 Tramo G2-G3 Tramo G3-G4

L=348.39 m
B1 657.8 m
E1 L=240.44 m L=214.65 m L=136.94 m Q=500,9 m3/h
3"

2"
Q=938.68 m3/h 1 G1 3" G2 3" G3 3" G4 S1

D1

Tramo S1-1
Tramo E-E1

L=137.13 m
Tramo G-G1
Tramo B-B1
L=203.09 m

L=119 m
Tramo D-D1

L=61.57 m
L=152.01m

3"

2"
3"
2"

2"

Tramo 2
L=1.7 m
Tramo A-A1 6"
Tramo A2-A1 Tramo 3 Tramo 4 Tramo 5 Tramo 6 Tramo 7 Tramo 8 Tramo 9 Tramo 10 Tramo 11 Tramo 12 Tramo 13 Tramo 14 Tramo 15 Tramo 16 Tramo 17 Tramo 18 Tramo 19 Tramo 20
L=375.02 m L=537.17 m L=48.36 m L=3.07 m L=175.61 m L=12.24 m L=663.03 m L=47.41 m L=278.86 m L=207.99 m L=23.91 m L=134.22 m L=47.12 m L=3.3 m L=144.22 m L=13.92 m L=145.75 m L=7.11 m L=144.29 m L=59.4 m
2" 2" A B 6" C 6" D 6" E 6" F 6" G 6" H 4" I 4" J 4" K 4" L 4" M 4" N 4" O 4" 4" Q 4" R 4" S 4" T
A2 A1 P
Tramo H-H1

Tramo L1-1
L=131.1 m
L=11.9 m
Tramo C-C1

Tramo F-F1
L=156.98 m
L=165.1 m

H3 Tramo H2-H3 Tramo H1-H2 2"

2"
L=349.6 m L=187.3 m

Tramo N1-1
2"
3"

L=220.1 m
1 2" H2 2"
Q=856.58 H1

L=302.48 m
Tramo I1-1
Q=2,165.07 m3/h

Tramo H2-H21

3"
m3/h

Tramo R1-1

Tramo T1-1
Tramo P1-1

L=322.39 m
L=305.47 m

L=108.3 m
L=103.5 m

2"
L1

2"
F1 Q=518.83 m3/h

2"

2"

2"
C1
Tr

Tramo H1-1
L= amo

L=401.2 m
19 C1
Tramo C1-C2

Q=599.61 m3/h

Tramo J1-1
2" .31 -1
L=140.5 m

2"
Tramo H21-1

L=543.5 m
Tr =24 "

m L=154.33 m N1
PROPIETARIO: CONSULTOR:
L 2
am 9.5
2"

H21

3"
3/h

1 2" Q=563.52 m3/h


oF 8m
5m

1
1-
1
6.8
65

Tramo H21-2
C2 I1
Tramo F1-F2

L=269.3 m
P1 T1
Q=

L=388.5 m

Q=1660.74 m3/h
2"
Q=1,565.33 m3/h R1 Q=375.69 m3/h
1 h
Tr 3/
2"

Q=1,690.52 m3/h
L= amo m
L=1160.79 m

28 C 5
Tramo 1

.9
Tramo C2-C3

2 2
2" .15 -2 23
L=207.16 m
8"

m =5
Q
PROYECTO:
2"

1
ESTUDIO DE PRE INVERSION PARA LA

Tramo K1-1
L=871.2 m
3/h

2 Q=553.95 m3/h
3m

2 IMPLEMENTACION DE LA SEGUNDA FASE Y ZONA DE

2"
Q=296.98 m3/h
.0

AMPLIACION DEL PARQUE INDUSTRIAL DE SANTIVAÑEZ


53

C3
1,6
Q=

F2
J1
h
98.8 3 m3/ Q=553.95 m3/h PLANO:
Tr Q=1,7
L= amo
40 C
2 3
DIAGRAMA RED DE GAS
2" .08 -3
m

CONTENIDO:
/h
m3

3
.55

DIAGRAMA DE RED DE GAS


60
Tr =74 2"

1,9
am 0
L

Q=
o C .91
3- m

ESCALA: GESTION: LAMINA: RG-PG-02


C4

K1
INDICADA 2022 1/1
Q=2,179.07 m3/h
h
C4 m3/
6 APROBACION Vº Bº SUPERVISION:
9.9
COBOCE

,14 TUBERÍA DE 8 RED


Q=10,000 m3/h

1
TUBERÍA DE 8" RED COBOCE Q= COBOCE
CITY GATE L=3206.97 m PUNTO DE CONEXIÓN L=25048.75 m
8" 0 8"

EMPRESA: