Está en la página 1de 1

1 2 3 4

FIELD / CAMPO
REMOTE I/O CABINET / GABINETE DE E/S REMOTAS

CABINET 4120-IO-130
CONTROLLER 4120-PC-101-CU
RACK BACKPLANE
SLOT A1.2
I/O TYPE AI

A.I 16xI 2-WIRE HART HA


17

18

2
A 19
A
3

20

21

22

23

24

25

26

10

27

11

28

12

29

13

30

14

31

15

B 32 B
16

AS BUILT
SIN CAMBIOS
AGO-02-2022

NOTAS/NOTES:

1. PARA NOMENCLATURA DE PANELES, GABINETES, CABLES Y OTROS, VER PLANO No.: MQ13-02-DR-0000-IN1050.
FOR NOMENCLATURE OF PANELS, CABINETS, CABLES AND OTHERS, SEE DRAWING No.: MQ13-02-DR-0000-IN1050.

2. TARJETA DE E/S LIBRE.


SPARE I/O CARD.
3. ESTE DOCUMENTO ES ALCANCE DEL CONTRATO K-CC4-153A1 Y CWP 41200010007.
THIS DOCUMENT IS THE SCOPE OF THE CONTRACT K-CC4-153A1 AND CWP 41200010007.

4. PARA DETALLE DE CONEXIONADO INTERNO VER PLANO MQ13-02-DR-0000-IN1064.


FOR INTERNAL CONNECTION DETAIL SEE DRAWING MQ13-02-DR-0000-IN1064.

PROYECTO JEFE DE GERENTE GERENTE


NO. FECHA DESCRIPCION CLIENTE
REV REVISO DISCIPLINA INGENIERIA AREA AngloAmerican
A 5/5/2020 ISSUED FOR INTERNAL REVIEW LT CR AC FC NB JM FECHA NOMBRE

0 5/8/2020 ISSUED FOR CONSTRUCTION PROYECTO05-08-2020 A.VYAS


PROYECTO
DETAIL ENGINEERING - QUELLAVECO
REVISO 05-08-2020 H. GARCES
AREA PRINCIPAL TAILINGS DAM
AB 08/02/2022 AS BUILT JEFE DISC.05-08-2020 A. CASTILLO SUB AREA TAILINGS TRANSPORTATION AND DISTRIBUTION
C GER. ING. 05-08-2020 F. COLON SECTOR DEL AREA
CYCLONE STATION C
GER. AREA05-08-2020 N. BLOME END POINT CONNECTION DIAGRAM / 4120-IO-130 / AIS02
CONTENIDO

CLIENTE 05-08-2020 J. MENDIVIL

ESCALA NUMERO DE PLANO REV.

PROYECTO N Q1CO S/E


MQ13-02-DR-4120-IN5002 AB

PATH FILE:
DATE: Wednesday, May 06, 2020
TIME: 5:49:34 PM
LAMINA No: DE1 1 SERIE No:
USER: $USERNAME$
1 2 4

También podría gustarte