Está en la página 1de 3

SECRETARIA DE AGUA Y ENERGÍA GOBIERNO AUTÓNOMO REGIONAL DEL CHACO TARIJEÑO - VILLA MONTES

PROYECTO: ESTUDIO DE IDENTIFICACIÓN "CONSTRUCCIÓN PRESA CAIGUAMI-CHIMEO"


MUNICIPIO: VILLA MONTES
PROVINCIA: GRAN CHACO
DEPARTAMENTO: TARIJA

TABLA RESUMEN DE PRECIPITACIONES ANUALES

ESTACIONES DE ESTUDIO
AÑO VILLA MONTES PALMAR GRANDE AGUARAYCITO

74-75
75-76 343.90 410.60
76-77 639.70 480.70
77-78 620.40 532.50
78-79 995.70 662.80
79-80 926.70 1,001.20
80-81 1,199.80 926.10
81-82 1,226.70 1,032.10
82-83 715.60 743.80
83-84 1,061.30 884.10
84-85 901.20
85-86
86-87
87-88
88-89 626.50
89-90 1,105.10
90-91 937.20
91-92 1,079.00 876.30 863.10
92-93 585.40
93-94 872.30 547.30 626.40
94-95 929.20 813.60 778.70
95-96 881.80 823.00 879.80
96-97 1,115.50 1,012.40 1,287.50
97-98 825.70 776.90 569.50
98-99 717.00 717.60 736.10
99-00 661.30 655.90 499.10
00-01 751.50 495.50
01-02 615.00 593.80 453.20
02-03 641.00 754.60 659.40
03-04 680.80 886.10 591.80
04-05 944.70 914.40 653.30
05-06 1,072.60 883.00 776.80
06-07 1,596.50 689.00 654.90
07-08 1,258.10 660.10 423.00
08-09 764.70 475.00 589.90
09-10 870.50 518.00 445.70
10-11. 681.00

MEDIA 881.15 734.28 675.78


S(h) 403.57 335.74 330.23
2
S2(h) 162,870.02 112,718.86
CURVA
CURVADOBLE
CURVA
CURVA
CURVADOBLE
CURVA
DOBLE
CURVA MASA
CURVAMASA
DOBLE
DOBLE
DOBLE
MASA
DOBLE MASA
DOBLE
MASA
MASAMASA
MASA
109,053.37
22
222

Cv 0.46 0.46 0.49


0
00
00
0000 0.20.20.2 0.4 0.4 0.6 0.6 0.8 0.8 1 1.2
00 0.2
0.20.2
0.2 0.2 0.4 0.4
0.4
0.4
0.4 0.4 0.6 0.60.6
0.6 0.6 0.6 0.8 0.80.8
0.8 0.8 0.8 11 11 11 1 1.2
1.2 1.21.2 1.2
1.2 1.2
ACUM.EST.
EST.PATRÓN
PATRÓN(mm)
(mm)
ACUM.
ACUM.
ACUM.
ACUM, ESTA. EST.
EST.
ACUM.EST.
EST.
PATRÓN PATRÓN
PATRÓN
PATRÓN
PATRÓN
ACUM.EST.
(mm)(mm) (mm) (mm)
(mm)
(mm)
PATRÓN
(mm)
(mm)
(mm)

N 31 29 17
(mm)
ACUM. EST. LEÓN CANCHA (mm)
EST.
ACUM.
EST.
ACUM.
ACUM.
ACUM. EST. JOCESITO
CHILLCAR
ÑACAMIRI
TOMAYAPO
ALTO
EST.
S. HUAYCO (mm)
CAJAS

TESA"CONSTRUCCIÓN PRESA CAIGUAMI - CHIMEO"


SECRETARIA DE AGUA Y ENERGÍA GOBIERNO AUTÓNOMO REGIONAL DEL CHACO TARIJEÑO - VILLA MONTES

CALCULO DE LA DESVIACIÓN PONDERADA


Nj  S 2 ( h)

k
 '2  h   j 1
 Nj
ESTACIÓN MEDIA S(h) S2(h) N Nj*S 2(h)
VILLA MONTES 881.15 403.57 162,870.02 31 5,048,970.54
PALMAR GRANDE 734.28 335.74 112,718.86 29 3,268,846.82
AGUARAYCITO 675.78 330.23 109,053.37 17 1,853,907.32

SUMA 77 10,171,724.67

Desviación Ponderada = 132,100.32

CALCULO DE LAS FRANJAS DE CONTROL


Para la curva Superior al 2.5% 0.025x2
S 2h    '2 (h) *
N 1
Para la curva Superior al 97.5% 0.975x 2
S 2 h    ' 2 (h) *
N 1

N x2(0.975) x2(0.025) S2(0.975) S2(0.025)


1 - - - -
2 5.02 0.00 663,657.01 129.73
3 7.38 0.05 487,302.16 3,344.49
4 9.35 0.22 411,642.37 9,502.21
5 11.14 0.48 368,007.94 15,997.96
6 12.83 0.83 339,035.53 21,960.66
7 14.45 1.24 318,127.85 27,242.26
8 16.01 1.69 302,184.47 31,890.32
9 17.53 2.18 289,539.90 35,992.89
10 19.02 2.70 279,212.64 39,635.81
11 20.48 3.25 270,583.43 42,892.61
12 21.92 3.82 263,240.50 45,823.78
13 23.34 4.40 256,898.40 48,478.49
14 24.74 5.01 251,352.41 50,896.73
15 26.12 5.63 246,451.53 53,111.18
16 27.49 6.26 242,081.70 55,148.69
17 28.85 6.91 238,155.00 57,031.54
18 30.19 7.56 234,602.47 58,778.32
19 31.53 8.23 231,369.15 60,404.68
20 32.85 8.91 228,410.68 61,923.88
21 34.17 9.59 225,690.80 63,347.24
22 35.48 10.28 223,179.57 64,684.48
23 36.78 10.98 220,851.99 65,944.00
24 38.08 11.69 218,687.07 67,133.11
25 39.36 12.40 216,666.97 68,258.16
26 40.65 13.12 214,776.46 69,324.77
27 41.92 13.84 213,002.47 70,337.86
28 43.19 14.57 211,333.66 71,301.80
29 44.46 15.31 209,760.17 72,220.47
30 45.72 16.05 208,273.40 73,097.36
31 46.98 16.79 206,865.77 73,935.55
32 48.23 17.54 205,530.58 74,737.84
33 49.48 18.29 204,261.93 75,506.75
34 50.73 19.05 203,054.53 76,244.55
35 51.97 19.81 201,903.67 76,953.31
36 53.20 20.57 200,805.13 77,634.89
37 54.44 21.34 199,755.11 78,291.02
38 55.67 22.11 198,750.19 78,923.26

TESA"CONSTRUCCIÓN PRESA CAIGUAMI - CHIMEO"


SECRETARIA DE AGUA Y ENERGÍA GOBIERNO AUTÓNOMO REGIONAL DEL CHACO TARIJEÑO - VILLA MONTES

Zonificación Pluviométrica
800,000.00

700,000.00

600,000.00

500,000.00
Varianzas (s 2(h))

400,000.00

300,000.00

200,000.00

100,000.00 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

0.00

-100,000.00
Número de Datos

al 97.50% al 2.5 % VILLA MONTES PALMAR GRANDE AGUARAYCITO

Podemos observar que las cuatro estaciones se encuentran en las siguientes zonas pluviométricas

ZONA A Estos pluviómetros pertenecen a una misma zona pluviométrica

AGUARAYCITO PALMAR GRANDE

ZONA B Estos pluviómetros pertenecen a una misma zona pluviométrica

VILLA MONTES

ZONA C Estos pluviómetros pertenecen a una misma zona pluviométrica

NO EXISTEN PLUVIÓMETROS

TESA"CONSTRUCCIÓN PRESA CAIGUAMI - CHIMEO"

También podría gustarte