Está en la página 1de 18

UNIVERSIDAD POLITECNICA SALESIANA

CARRERA DE INGENIERIA CIVIL


ALCANTARILLADO Y TRATAMIENTO DE AGUAS SERVIDAS
NOMBRES: Machay Tocte William Santiago TEMA: Caudales y diseño de la red
GRUPO: 2 Nº Pag:
NIVEL: 8 NºHojas:
FECHA: 11/30/2021 GRUPO TRABAJO:

CAUDALES POR TRAMO DE DISEÑO

DATOS:
AREA TOTAL 0.996 Ha
AREA INDUSTRIAL 0.08 Ha
AREA DOMICILIARIA 0.916 Ha
DOTACION 150 lt/hab/dia
DENSIDAD poblacional 3000 hab/ha
R 0.85
M 4
COEF. IND 0.6
COEF. ERR 1.1
COEF. INF 0.13

CALCULOS GENERALES
POBLC. FINAL 2748
Qdis DOM 16.22 lt/s
Q ind 0.048 lt/s
Q err 1.0956 lt/s
Q inf 0.12948 lt/s
Q DIS SAN 17.49 lt/s
qdis dom 17.71 lt/s/Ha
qind 0.6 lt/s/Ha
qerr 1.1 lt/s/Ha
qinf 0.13 lt/s/Ha

Rata de ocupacion (%) 100 %


HOMOGENEIDAD DE USO

CAUDALES PARA COLECTORES TERCIARIOS

CAUDALES PARCIALES
AREAS AREAS
TRAMO POZOS PARCIAL ACUMULADA
DOMESTICA DOMESTICA
AREAS AREAS
TRAMO POZOS PARCIAL ACUMULADA Q dom
DOMESTICA DOMESTICA Q ERR Q INF
PARCIAL

TERCIARIOS

P-6
5-6 0.079 0.079 1.40 0.09 0.01
P-5
P-8
7-8 0.08 0.08 1.42 0.09 0.01

P-7
P-1
1-4 0.091 0.091 1.61 0.10 0.01
P-4
P-4
4-5 0.148 0.239 2.62 0.16 0.02
P-5
P-1
1-2 0.148 0.148 2.62 0.16 0.02
P-2
P-3
3-2 0.039 0.039 0.69 0.04 0.01
P-2
P-6
6-3 0 0 0.00 0.09 0.01
P-3
P-2
2-5 0.171 0.358 3.03 0.19 0.02
P-5
P-5
5-7 0.06 0.736 1.06 0.07 0.01
P-7
P-6
6-8 0.06 0.06 1.06 0.07 0.01
P-8
P-8
8-9 0.02 0.08 0.35 0.02 0.00
P-9
P7
7-9 0.02 0.836 0.35 0.02 0.00
P-9

0.916

SECUNDARIOS
OP1 OP2
AREAS AREAS
Q dom POBLACIO
TRAMO POZOS PARCIAL ACUMULADA AREA TOTAL
PARCIAL N FUTURA
DOMESTICA DOMESTICA

P1
T1 0.091 0.091 0.091 1.61 273
P4
T2 0.148 0.239 0.239 4.23 717
P5

P6
T1 0 0 0.08 0.00 0
P3
T2 0.039 0.039 0.119 0.69 117
P2

P6
T1 0.06 0.06 0.06 1.06 180
P8
T2 0.02 0.08 0.14 1.42 240
P9
y diseño de la red

RCIALES Q DISEÑO
Q PARCIAL SANITARIO
SANITARIO ACUMULA
DO
Q DISEÑO
Q PARCIAL SANITARIO
Q IND SANITARIO ACUMULA
DO

0 1.50

0 1.52

0 1.72

0 2.80

0 2.80

0 0.74

0.048 0.15

0 3.24

0 1.14

0 1.14

0 0.38

0 0.38

17.49

IOS
Q DISEÑO
Q DOM
Q ERR Q inf Q ind SANITARIO
DISEÑO
(LT/S)

1.61 0.10 0.01 0.00 1.72

4.23 0.26 0.03 0.00 4.53

0.00 0.09 0.01 0.05 0.15

0.69 0.13 0.02 0.07 0.91

1.06 0.07 0.01 0.00 1.14

1.42 0.09 0.01 0.00 1.52


CAUDALES PARA COLECTORES PRIMARIOS
OP1 OP2
AREAS AREAS
Q dom POBLACIO Q DOM
TRAMO POZOS PARCIAL ACUMULADA
PARCIAL N FUTURA DISEÑO
DOMESTICA DOMESTICA

P1
T1 0.148 0.148 2.62 444 2.62
P2
T2 0.171 0.319 5.65 957 5.65
P5
T3 0.06 0.379 6.71 1137 6.71
P7
T4 0.02 0.399 7.07 1197 7.07
P9
TORES PRIMARIOS
Q DISEÑO
Q ERR Q inf Q ind Q ADICIONAL SANITARIO
(LT/S)

0.16 0.02 0.00 2.80


0.91
0.35 0.04 0.00 6.95
6.93
0.42 0.05 0.00 14.11
8.45
0.44 0.05 0.00 16.00

CAUDAL
17.52 lt/s
EMISARIO
TER
QDIS SAN L D I
TRAMOS POZOS N
m mm %
P6
T1 1.50 40 250 0.01 5%
P5

P8
T1 1.52 40 250 0.01 5%
P7

SEC
QDIS SAN L D I
TRAMOS POZOS N
lt/s m mm %
P1
T1 1.72 60 250 0.01 1.75%
P4

T2 4.53 80 250 0.01 1.56%


P5

P6
T1 0.15 60 250 0.01 1.92%
P3

T2 0.91 40 250 0.01 1.75%


P2

P6
T1 1.14 50 250 0.01 2.00%
P8

T2 1.52 44.72 250 0.01 13.30%


P9

PR
QDIS SAN L D I
TRAMOS POZOS N
TRAMOS POZOS N
lt/s m mm %

P1
T1 2.80 80 250 0.01 1.88%
P2

T2 6.95 60 300 0.01 1.33%


P5

T3 14.11 50 300 0.01 1.40%


P7

T4 16.00 44.72 300 0.01 8.83%


P9
TERCIARIOS
FASE1 FASE2
Qd/QLL*10% Vmin γ
VLL QLL Qd/QLL Vd
m/s lt/s % m/s % m/s mm

3.5216 172.87 0.87% 1.15 0.09% 1.01 2.16

3.5216 172.87 0.88% 1.15 0.09% 1.01 2.19

SECUNDARIO
FASE1 FASE2
Qd/QLL*10% Vmin γ
VLL QLL Qd/QLL Vd
m/s lt/s % m/s % m/s mm

2.0834 102.27 1.69% 0.76 0.17% 0.59 4.21

1.9686 96.63 4.68% 0.96 0.47% 0.55 11.71

2.1804 107.03 0.14% 0.63 0.01% 0.61 0.34

2.0834 102.27 0.89% 0.68 0.09% 0.59 2.22

2.2272 109.33 1.04% 0.74 0.10% 0.63 2.60

5.7445 281.98 0.54% 1.77 0.05% 1.62 1.34

PRIMARIO
FASE1 FASE2
Qd/QLL*10% Vmin γ
VLL QLL Qd/QLL Vd
m/s lt/s % m/s % m/s mm

2.1565 105.86 2.65% 0.88 0.26% 0.61 6.62

2.0536 145.16 4.79% 1.01 0.48% 0.58 14.36

2.1043 148.74 9.49% 1.34 0.95% 0.59 28.46

5.2854 373.61 4.28% 2.51 0.43% 1.49 12.85


COTAS
TERRENO PROYECTO H POZO SALTO
msnm msnm m
123 121.25 C.S 1.75

121 119.25 C.E 1.75


121 118.95 C.S 2.05 0.3

122 120.25 C.S 1.75

120 118.25 C.E 1.75


120 118.25 C.S 0

COTAS
TERRENO PROYECTO H POZO
msnm msnm m
123 121.25 C.S 1.75

122 120.2 C.E 1.8


122 120.2 C.S 1.8 0

121 118.95 C.E 2.05


121 118.95 C.S 2.05 0

123 121.25 C.S 1.75

122 120.1 C.E 1.9


122 120.1 C.S 0

121.5 119.4 C.E 2.1


121.5 119.4 C.S 2.1 0

123 121.25 C.S 1.75

122 120.25 C.E 1.75


122 120.25 C.S 1.75 0

116 114.3 C.E 1.7


116 114.3 C.S 0

COTAS
TERRENO PROYECTO H POZO
msnm msnm m

123 121.25 C.S 1.75

121.5 119.75 C.E 1.75


121.5 119.4 C.S 2.1 0.35

121 118.95 C.E 2.05


118.95 C.S 0

120 118.25 C.E 1.75


118.25 C.S 0

116 114.3 C.E 1.7


114.3 C.S 0

También podría gustarte