Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Informe Lab03
Informe Lab03
LABORATORIO: N°3
FECHA: 09/11/21
GRUPO: N°3
INTEGRANTES:
1 3 √3
V RMS(R )=√ 3 V m
√ +
2 4π
cos 2 α Para α < 60°
3 α 3 √3 3
V RMS(R )=√ 3 V m 1−
√ +
2π 8π
cos 2 α −
8π
sin 2α Para α >60 °
Para α =0 °
1 3 √3
V RMS(R )=√ 3 ( 80 )
√ +
2 4π
cos 0° =132.435V
Para α =30 °
1 3 √3
V RMS(R )=√ 3 ( 80 )
√ +
2 4π
cos 60 ° =116.488 V
Para α =60 °
1 3 √3
V RMS(R )=√ 3 ( 80 )
√ +
2 4π
cos 120 °=75.036 V
Para α =90 °
90 3 √ 3 3
V RMS(R )=√ 3 ( 80 ) 1−
√ +
120 8 π
cos 180 °−
8π
sin180 ° =28.817V
Para α =120 °
120 3 √3 3
V RMS(R )=√ 3 ( 80 ) 1−
√ +
120 8 π
cos 240 °−
8π
sin 240° =0 V
CORRIENTE PROMEDIO EN LA CARGA
V DC( R)
I DC (R) =
R
Para α =0 °
132.139
I DC (R) = =1.321 A
100
Para α =30 °
114.592
I DC (R) = =1.146 A
100
Para α =60 °
66.159
I DC (R) = =0.662 A
100
Para α =90 °
17.727
I DC (R) = =0.177 A
100
Para α =120 °
0
I DC (R) = =0 A
100
V RMS
I RMS (R) =
R
Para α =0 °
132.435
I RMS (R) = =1.324 A
100
Para α =30 °
116.488
I RMS (R) = =1.165 A
100
Para α =60 °
75.036
I RMS (R) = =0.75 A
100
Para α =90 °
28.817
I RMS (R) = =0.288 A
100
Para α =120 °
0
I RMS (R) = =0 A
100
CORRIENTE PROMEDIO POR CADA TIRISTOR
I DC (R)
I DC (T )=
3
Para α =0 °
1.321
I DC (T )= =0.440 A
3
Para α =30 °
1.146
I DC (T )= =0.382 A
3
Para α =60 °
0.662
I DC (T )= =0.221 A
3
Para α =90 °
0.177
I DC (T )= =0.059 A
3
Para α =120 °
0
I DC (T )= =0 A
3
I RMS (R)
I RMS (T )=
√3
Para α =0 °
1.324
I RMS (T )= =0.764 A
√3
Para α =30 °
1.165
I RMS (T )= =0.673 A
√3
Para α =60 °
0.75
I RMS (T )= =0.433 A
√3
Para α =90 °
0.288
I RMS (T )= =0.166 A
√3
Para α =120 °
0
I RMS (T )= =0 A
√3
VOLTAJE PROMEDIO EN LA FUENTE
Para 0 ° ≤α ≤120 °
V DC (F )=0V
Para 0 ° ≤α ≤120 °
80
V RMS (F )= =56.569V
√2
CORRIENTE PROMEDIO EN LA FUENTE
Para 0 ° ≤α ≤120 °
I DC ( F )=0 A
2
I RMS (F )=
√ I
3 DC (R )
Para α =0 °
2
I RMS ( F )=
√ 3
(1.321)=1.079 A
Para α =30 °
2
I RMS (F )=
√ 3
(1.146)=0.936 A
Para α =60 °
2
I RMS (F )=
√ 3
(0.662)=0.541 A
Para α =90 °
2
I RMS (F )=
√ 3
(0.177)=0.145 A
Para α =120 °
2
I RMS (F )=
√ 3
(0)=0 A
α (°) 0 30 60 90 120
V DC (R ) (V) 132.319 114.592 66.159 17.727 0
V DC (F ) (V) 0 0 0 0 0
I DC ( R ) (A) 1.321 1.146 0.662 0.177 0
I DC (T )(A) 0.440 0.382 0.221 0.059 0
I DC ( F )(A) 0 0 0 0 0
4.3. SIMULACIÓN
Figura 1
Entradas de 0° ≤ α ≤ 120°
Formas de onda para α = 0°
Formas de onda para α = 30°
Formas de onda para α = 60°
Formas de onda para α = 90°
Formas de onda para α = 120°
Formas de onda en V4
Relación voltaje de salida con el voltaje entre líneas de entrada para α = 30°
Secuencia de disparo
4.4. VALORES OBTENIDOS EN SIMULACIÓN
ANGULOS
MEDICIONES VP4 VP1 VP2 VP3
DE DISPARO
0° 132.435 97.967 98.004 97.967
30° 116.197 97.967 98.004 97.967
VALORES
60° 74.573 97.967 98.004 97.967
EFICACES
90° 28.394 97.967 98.004 97.967
120° 0 97.967 98.004 97.967
ANGULOS
MEDICIONES VP4 VP1 VP2 VP3
DE DISPARO
0° 132.318 0.035 -0.069 0.035
30° 114.263 0.035 -0.069 0.035
VALORES
60° 65.586 0.035 -0.069 0.035
PROMEDIOS
90° 17.374 0.035 -0.069 0.035
120° 0 0.035 -0.069 0.035
ANGULOS
MEDICIONES I1 I2 I4 I5
DE DISPARO
0° 1.081 1.082 0.764 1.324
30° 0.949 0.949 0.671 1.162
VALORES
60° 0.609 0.609 0.431 0.746
EFICACES
90° 0.232 0.232 0.164 0.284
120° 0 0 0 0
ANGULOS
MEDICIONES I1 I2 I4 I5
DE DISPARO
0° 0 0 0.440 1.323
30° 0 0 0.381 1.143
VALORES
60° 0 0 0.219 0.656
PROMEDIOS
90° 0 0 0.058 0.174
120° 0 0 0 0
4.5. CUADRO COMPARATIVO
4.6. CÁLCULO DEL ERROR PORCENTUAL
5. OBSERVACIONES Y CONCLUSIONES
5.1. OBSERVACIONES
La amplitud máxima del voltaje promedio de salida en VP4 es la diferencia de voltajes entre
líneas de la entrada.
Los valores de voltaje y corriente promedio de la carga son muy cercanos a los valores
eficaces de los mismos.
Se realizaron las pruebas de funcionamiento obteniendo resultados muy cercanos a las
pruebas de simulación.
Al momento de realizar esta experiencia en la práctica, se tiene que tener consigo todos los
elementos de protección eléctrica: epps de seguridad (guantes dieléctricos, gafas, botas
dieléctricas, etc.), sistema eléctrico conectado al pozo a tierra, y las cinco reglas de oro en la
electricidad.
Se observa que, en el circuito simulado, la parte de rectificación de voltaje trifásico de la
carga es la etapa de potencia, mientras que la parte del ángulo de disparo en los gates de los
SCR, es la etapa de control.
5.2. CONCLUSIONES
Se determinó que los SCR, son dispositivos de control de corriente en un sentido, y nos
permitió la regulación del valor medio de la tensión en la carga, a través del ángulo de
disparo en su puerta gate.
Debido a que la transición de la tensión de línea a línea más elevada se realiza cada sexto de
periodo del generador el puente se denomina: rectificador de seis pulsos.
Se concluye de las formas de onda de salida lo siguiente conducción (figura 1), VP3(+) –
VP2(-); VP3(+) – VP1(-); VP2(+) – VP1(-); VP2(+) – VP3(-); VP1(+) – VP3(-); VP1(+) –
VP2(-); y así sucesivamente se generará la onda de salida.