Está en la página 1de 1

1.20 2.

50
0.30
A B C
0.82
9.57

Inferior: Ø5/8" @ 0.20 m

Inferior: Ø5/8" @ 0.20 m


0.30 4.32 5.25
0.40 0.25
2.67 1.50 4.80 0.30
2
4 4 1.20 1.20
0.40
C-1 NFC -1.35 C-1 0.40
C-1 P-1
P-3
2 8Ø5/8" Solo en el primer nivel
Inferior: Ø5/8" @ 0.20 m Inferior: Ø5/8" @ 0.20 m
Ø3/8": 1@0.05, 6@0.10 12Ø5/8"
h=0.50 h=0.50 h=0.50
NFZ -1.85 NFZ -1.85 NFZ -1.85
R@0.20 CL 2 Ø3/8": 1@0.05, 6@0.10
R@0.20 CL
Z-1 Z-2 Z-1 H/6
Z-1 Z-2

NFC -1.35
NFC -1.35

3.70 3.70 h = 0.50 h = 0.50 Le

NFC -1.35
3.10 3.10 8Ø5/8"
2 2 NFZ -1.85 NFZ -1.85 Le
4 4 Ø3/8": 1@0.05, 6@0.10
1 1
R@0.20 CL
1.80 Ø Le(m)
0.95 0.30
3/8" .40
1/2" .45 2H/3 H Ø1/2"@0.20
1.40 5/8" .60 0.15
3/4" .80 0.40
1" 1.00 0.25
3 0.40 C-1 C-1 C-1 0.40 3 Ø Le(m)
Le 3/8" .70
1/2" .80 4Ø5/8" Ø1/2" @ 0.20 m
5/8" 1.00 Ø3/8": 1@0.05,

Inferior: Ø5/8" @ 0.20 m


h=0.50 h=0.50
NFZ -1.85 NFZ -1.85
P-2

Inferior: Ø5/8" @ 0.20 m


3/4" 1.40 6@0.10, R@0.20 CL
h=0.50 H/6
Z-3 NFZ -1.85 Z-3 1" 1.70
Z-4

NFC -1.35
NFC -1.35

1.80 2.40
4Ø5/8"
NFC -1.35

10.99 3.55 3.15 3.15 3.55 10.99 1.20 0.30


2 2 CASO 1
Ø3/8": 1@0.05, Ø1/2"@0.20
CASO 2
1 1 6@0.10, R@0.20 CL
4 4
h=0.50
NOTA.- EN AMBOS CASOS EN UNA MISMA
Inferior: Ø5/8" @ 0.20 m
NFZ -1.85 COLUMNA NO EMPALMAR MAS DEL 50% 0.25
NPT. - 0.50
Z-4 DEL AREA DE ACERO DE LA SECCION 0.40
Inferior: Ø5/8" @ 0.20 m
P-2 Ø1/2" @ 0.20 m

2 0.40 C-1 C-1 0.40 2 DETALLE DE EMPALME DE COLUMNAS 0.25 0.95 0.30
Z-3 8Ø5/8"
h = 0.50 P-3 Ø3/8": 1@0.05, 6@0.10
h=0.50 h=0.50
NFZ -1.85 R@0.20 CL
NFZ -1.85 NFZ -1.85
Z-4
Z-3 Z-3 h = 0.50
NPT. + 0.20
NFC -1.35

1 1 4 4 NFZ -1.85 DETALLE DE COLUMNAS

NFC -1.35
NFC -1.35

NFC -0.75

2 2 NFP +0.15
3.14 3 3 3.14 1.20 3.42 ESC: 1/20
3.74 3.74
Z-6 Z-5 0.05
h=0.50
Z-5 h=0.50
0.10
h=0.50
NFZ -1.85 NFZ -1.85
Z-6

Superior: Ø5/8" @ 0.20 m


NFZ -1.85

Inferior: Ø5/8" @ 0.20 m


cimiento h = 0.50
escalera
NFZ -1.85

Inferior: Ø5/8" @ 0.20 m


0.50 0.50
P-1 NPT. + 0.40
1.20
0.40 C-1 C-1 C-1 0.40
Ø3/8"@.10
1 NPT. + 0.20
1 1.60 1.60 1.40
Inferior: Ø5/8" @ 0.20 m
0.30 2.00 0.82 1.05 0.30 4.80 0.30 Superior: Ø5/8" @ 0.20 m
4.32 5.25 C-1
9.57 P-1 2 ALAMBRES Ø 6mm
CADA 03 HILADAS
Inferior: Ø5/8" @ 0.20 m
0.40
A
B C 0.15

CIMENTACIONES Z-5 0.30 0.82 1.05 0.30 0.95


NFZ -1.85
0.30 0.30 0.50
h = 0.50
ESC: 1/50
NFZ -1.85 0.070

VER DETALLE DE ZAPATAS SOLADO 0.05m


DETALLE DE ZAPATAS DETALLE DE ANCLAJE
ESC: 1/25 DETALLE DE ANCLAJE DE DE MUROS EN COLUMNAS
0.180
COLUMNA EN ZAPATAS ESC. S/E
0.150

0.15 0.15 0.15 0.156


0.15 0.30 0.30
0.156
Muro
Tabiquería Tabiquería

Rto. @.20
Portante Muro NPT +0.40
Sobrecimiento 0.156
Portante
Sobrecimiento a
NPT +0.20 NPT +0.20 NPT +0.20 NPT +0.20 NPT +0.20 0.156 NPT +0.20
armado @.15 a r
NFP +0.15 NFP +0.15 NFP +0.15 NFP +0.15
0.25 r r (cm) a (cm)
0.20 0.20 0.20 Ø
NTN 0.00 NTN 0.00 NTN 0.00 NTN 0.00 NPT 0.00 0.350
0.30 1/4" 2.5 7.5
0.10 0.10 0.10 0.20 1@0.05 Ø DE COLUMNA
VEREDA 0.10 0.10 PLACA O VIGA 3/8" 3.8 10.0
0.30
Ø3/8"@0.25 Ø3/8"@0.25 0.20 @.10 45°
0.30 Ø3/8"@0.25
Sobrecimiento Sobrecimiento 0.85
armado armado Ø1/2"@0.20 Ø1/2"@0.20
Ø1/2"@0.20 @.10 r
NPT -0.50 NPT -0.50
0.80 0.80 NFP -0.55 Cimiento NFP -0.55 0.75 0.75 1@0.05 a
0.60
0.50 GANCHO ESTRIBOS
NFC -0.75 NFC -0.75
0.10 GANCHO GRAPAS
@.15
0.10
DETALLE DE GANCHOS

Rto. @.20
Cimiento
Cimiento Cimiento 0.40
0.60 1@0.05

0.60 0.60 CORTE 3-3 0.60


NFC -1.35 NFC -1.35 NFC -1.35 CIMIENTO ESCALERAS
ESTRIBO
@.10 Longitudinal
Transversal
Especificado
0.60 0.40 0.60 REMATE DE COLUMNAS Refuerzo Superior
0.070

6cm

CORTE 1-1 CORTE 2-2 CORTE 4-4 Peralte

Rto. @.20
de Zapata
Transversal Longitudinal ATORTOLAR EL AL Ø VERTICAL
DETALLE DE CIMIENTOS CORRIDOS 6cm ESPACIAMIENTO IGUAL AL
Refuerzo Inferior ESTRIBO HORIZONTAL
ESC: 1/25 0.070 Especificado

REFUERZO TRANSVERSAL DETALLE DE UBICACIÓN DE REFUERZO DETALLE DE GANCHO EN


DE COLUMNAS ESC: 1/25 COLUMNAS
PARAMETROS SISMORESISTENTES ESPECIFICACIONES GANCHOS ESTANDAR PARA BARRAS LONGITUDINALES
a) SISTEMA ESTRUCTURAL SISMORESISTENTE RECUBRIMIENTOS
X-X : DUAL CONCRETO ARMADO ZAPATAS 7 cm. LONGITUD
CIMENTACION LONGITUD DE ANCLAJE ldg VIGAS - LOSAS
Y-Y : ALBAÑILERÍA CONCRETO GANCHO r (cm)
f'c = 210 Kg/cm2 COLUMNAS Y VIGAS PERALTADAS 4 cm.
1) PARA EL TRAZADO DE LA CIMENTACION VER ARQUITECTURA. Ø
b) PARAMETROS PARA DEFINIR FUERZA SISMICA ACERO CORRUGADO fy = 4200 Kg/cm2 VIGUETAS, COLUMNETAS, S/C ARMADO (e=.15) 2 cm.
2) PARA CONFORMAR EL RELLENO USAR MATERIAL PROPIO SELECCIONADO (cm) ldg
Ø
ESPECTRO DE DISEÑO
Factor de zona : Z = 0.35 (Zona 3)
CONCRETO SIMPLE VIGAS CHATAS Y PLACAS
LOSAS Y ALIGERADO
2 cm.
2 cm.
COMPACTADO AL 95% PROCTOR MODIFICADO EN CAPAS DE 20cm.
3) ANTES DE VACIAR EL FALSO PISO CONFORMAR UN RELLENO DE 10 CM 1/4" 10 3.8
r
(cm) CONSTRUCCIÓN DE VIVIENDA
SOLADO e = 0.05 m C:H = 1:12 1/4" 15
Factor de suelo
Factor de uso
Coef. de reducción
: S = 1.15, Tp = 0.6 s. (Tipo S2)
: U = 1.0 (Categoria C)
: Rx = 7.00 (Dual) CIMIENTO CORRIDO f'c= 100 Kg/cm2+30%P.G.
ALBAÑILERIA
CON MATERIAL DE PRESTAMO COMPACTADO AL 95% PROCTOR MODIFICADO 3/8" 15 5.7
7.6
12 db 3/8" 20
MULTIFAMILIAR
: Ry = 3.00 (Albañilería) (Tamaño maximo 6")
1/2" 15
DIMENSIONES (MINIMAS) 23x13x9 cm
Coef. de amplificación sísmica : C = 2.50 5/8" 20 9.5 1/2" 30
SOBRECIMIENTO f'c= 140 Kg/cm2+25%P.M. USAR LADRILLO MACIZO INDUSTRIAL 30% MAX DE LEYENDA PROPIETARIO:
RESUMEN DE LAS CONDICIONES (Tamaño maximo 3") ÁREA DE ALVEOLOS PARA MUROS PORTANTES 3/4" 25 11.5 5/8" 35 REGION : ANCASH Nº LAMINA
NTN = NIVEL DE TERRENO Ldg VICTOR RAÚL PAREDES ESTELA
DE LA CIMENTACION
1) PRESION ADMISIBLE: q = 1.50 Kg/cm2.
MORTERO (CEMENTO/ARENA)
ESPESOR JUNTA ENTRE HILADAS
1/4
1.0 cm (Min.)
NPT = NIVEL PISO TERMINADO
NFP = NIVEL FALSO PISO
NFZ = NIVEL FONDO ZAPATA
NFC = NIVEL FONDO CIMIENTO
1"
1 3/8"
30
40
15.5
28
3/4"
1"
40
55
PROVINCIA : HUARAZ
DISTRITO : HUARAZ PLANO:
ESTRUCTURAS - CIMENTACIONES E-01
1.5 cm (Max.)
1 3/8" 75
ESCALA: FECHA: ESPECIALIDAD:
INDICADA octubre 2021 ESTRUCTURAS