ANALISIS SISMICO ESTATICO

0.75R
h Pcm Pcv Ps H
Nivel P(H^{K}) α Fi LABEL DesX(m) Relat(m) Drift-elast Drift-Inela Norma
(m) (tonf) (tonf) (Tonf) (m)
10 2.80 486.595 47.268 498.41 30.30 28385.60 0.1785 98.34 274 0.053022 0.00183 0.00065 0.0039 0.007 CUMPLE
9 3.00 517.771 118.170 547.31 27.50 27787.24 0.1748 96.27 244 0.051189 0.00311 0.00104 0.0062 0.007 CUMPLE
8 3.00 519.850 118.170 549.39 24.50 24324.53 0.1530 84.27 214 0.048078 0.00418 0.00139 0.0084 0.007 NO CUMPLE
7 3.00 519.850 118.170 549.39 21.50 20836.38 0.1310 72.19 184 0.043897 0.00509 0.00170 0.0102 0.007 NO CUMPLE
6 3.00 519.850 118.170 549.39 18.50 17437.38 0.1097 60.41 154 0.038808 0.00583 0.00194 0.0117 0.007 NO CUMPLE
5 3.00 519.850 118.170 549.39 15.50 14139.23 0.0889 48.99 124 0.032974 0.00641 0.00214 0.0128 0.007 NO CUMPLE
4 3.00 519.850 94.536 543.48 12.50 10839.90 0.0682 37.56 94 0.026562 0.00682 0.00227 0.0136 0.007 NO CUMPLE
3 3.00 519.850 94.536 543.48 9.50 7830.50 0.0492 27.13 64 0.019743 0.00704 0.00235 0.0141 0.007 NO CUMPLE
2 3.00 519.850 94.536 543.48 6.50 4994.47 0.0314 17.30 34 0.012707 0.00692 0.00231 0.0138 0.007 NO CUMPLE
1 3.50 525.046 94.536 548.68 3.50 2421.25 0.0152 8.39 4 0.005789 0.00579 0.00165 0.0099 0.007 NO CUMPLE
∑ 5422.4275 ∑ 158996.47 1 550.85

PESO SISMICO TOTAL DE LA EDIFICACION


PS = 5422.43 Tonf
REPORTE DEL SAP2000
274 SEX LinStatic 0.053022
244 SEX LinStatic 0.051189
PARAMETROS SISMICOS FUERZA CORTANTE BASAL 214 SEX LinStatic 0.048078
Z 0.45 ZUCS/R 0.1016 184 SEX LinStatic 0.043897
U 1.00 154 SEX LinStatic 0.038808
C 1.72 Vbasal = 550.9 tonf 124 SEX LinStatic 0.032974
S 1.05 94 SEX LinStatic 0.026562
R 8.00 64 SEX LinStatic 0.019743
T 0.87 34 SEX LinStatic 0.012707
K 1.185 4 SEX LinStatic 0.005789