Está en la página 1de 34

ANÁLISIS DINÁMICO TIEMPO HISTORIA DE VGDL

Sismo de Atico del 23/03/2001 E-W


Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

MATRIZ MASA Y MATRIZ RIGIDEZ

0.4498 0 0 0 0
0 0.4447 0 0 0
M= 0 0 0.4447 0 0
0 0 0 0.4447 0
0 0 0 0.00 0.4076

879.442 -370.162 0 0 0
-370.162 720.467 -350.305 0 0
K= 0 -350.305 700.610 -350.305 0
0 0 -350.305 781.039 -430.734
0 0 0 -430.734 430.734

MODOS DE OSCILACIÓN MATLAB: [V,D]=eig(K,M)

0.2025 -0.5991 0.8634 0.8819 -0.5479


0.4625 -0.9529 0.3740 -0.6564 0.7457
Φ= 0.6927 -0.5449 -0.9022 -0.1422 -0.7986
0.8564 0.3102 -0.3473 0.8355 0.7749
0.9225 0.7986 0.6772 -0.5843 -0.4057

NORMALIZACIÓN DE MODOS (ÚLTIMO PISO IGUAL A 1)

Modo1 Modo2 Modo3 Modo4 Modo5


0.0000 0.0000 0.0000 0.0000 0.0000
0.2195 -0.7502 1.2749 -1.5092 1.3506
0.5013 -1.1932 0.5522 1.1234 -1.8383
X= 0.7509 -0.6823 -1.3322 0.2433 1.9687
0.9283 0.3884 -0.5129 -1.4299 -1.9101
1.0000 1.0000 1.0000 1.0000 1.0000

PERIODOS DE OSCILACIÓN MATLAB: [V,D]=eig(K,M)

ω2 (rad2/s2) 75.70 646.30 1598.70 2567.80 3075.30


ω (rad/s) 8.70 25.42 39.98 50.67 55.46
T (s) 0.72 0.25 0.16 0.12 0.11

______________________________________________________________________________
Pág. 1.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
ANÁLISIS DINÁMICO TIEMPO HISTORIA DE VGDL
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

MODO 1 MODO 2

5 5

4 4
PISO

3 PISO 3

2 2

1 1

0 0
0.00 0.20 0.40 0.60 0.80 1.00 1.20 -2.00 -1.00 0.00 1.00 2.00

MODO 3 MODO 4

5 5

4 4
PISO
PISO

3 3

2 2

1 1

______________________________________________________________________________
Pág. 2.. .
ANÁLISIS SÍSMICO LINEAL
0 ELÁSTICO DE ESTRUCTURAS 0
-1.50 -1.00 -0.50 0.00 0.50 1.00 1.50 -2.00 -1.50 -1.00 -0.50 0.00 0.50 1.00 1.50
PISO
PISO
3 3

2 2
ANÁLISIS DINÁMICO TIEMPO HISTORIA DE VGDL
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
1 1
ing_erlyenriquez@hotmail.com

0 0
-1.50 -1.00 -0.50 0.00 0.50 1.00 1.50 -2.00 -1.50 -1.00 -0.50 0.00 0.50 1.00 1.50

MODO 5

4
PISO

0
-3.00 -2.00 -1.00 0.00 1.00 2.00 3.00

FACTORES DE PARTICIPACIÓN ESTÁTICA

Γ_𝑖=( 〖𝑋 _𝑖
〗 ^𝑇 𝑀
1)/( 〖𝑋 _𝑖 〗
^𝑇 𝑀 𝑋_𝑖 )
1
1
1 = 1
1
1

1.2562
-0.3770
Γ = 0.1863

______________________________________________________________________________
Pág. 3.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
ANÁLISIS DINÁMICO TIEMPO HISTORIA DE VGDL
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com
-0.1022
0.0368

______________________________________________________________________________
Pág. 4.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
ANÁLISIS DINÁMICO TIEMPO - HISTORIA MODO 1
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

T: Periodo de la Estructura (s) 0.72


ωn: Frecuencia natural angular (rad/s) 8.70
ξ: Fracción de amortiguamiento crítico 0.05
ϒ: Coeficiente gama 0.50
β: Coeficiente beta 0.17
Δt: Variación del tiempo (s) 0.01

A 1.01 C 1.63
B 75.70 D 0.01

t (s) u''gi (cm/s2) u''i (cm/s2) u'i (cm/s) ui (cm)


0.00 0.07 0.07 0.00 0.0000
0.01 0.07 -0.07 0.00 0.0000
0.02 0.07 -0.07 0.00 0.0000
0.03 0.07 -0.07 0.00 0.0000
0.04 0.09 -0.08 0.00 0.0000
0.05 0.14 -0.13 0.00 -0.0001
0.06 0.27 -0.26 -0.01 -0.0001
0.07 0.55 -0.53 -0.01 -0.0002
0.08 1.02 -0.98 -0.02 -0.0003
0.09 1.62 -1.55 -0.03 -0.0005
0.10 2.12 -2.01 -0.05 -0.0009
0.11 2.20 -2.03 -0.07 -0.0015
0.12 1.62 -1.38 -0.08 -0.0022
0.13 0.53 -0.21 -0.09 -0.0031
0.14 -0.54 0.93 -0.09 -0.0040
0.15 -1.02 1.46 -0.08 -0.0049
0.16 -0.76 1.23 -0.06 -0.0056
0.17 -0.17 0.69 -0.05 -0.0062
0.18 0.18 0.36 -0.05 -0.0067
0.19 0.21 0.37 -0.04 -0.0071
0.20 0.29 0.32 -0.04 -0.0076
0.21 0.79 -0.16 -0.04 -0.0080
0.22 1.43 -0.76 -0.05 -0.0084
0.23 1.43 -0.72 -0.05 -0.0089
0.24 0.34 0.42 -0.05 -0.0094
0.25 -1.37 2.16 -0.04 -0.0099
0.26 -2.53 3.31 -0.01 -0.0102
0.27 -2.26 3.01 0.02 -0.0102
0.28 -0.73 1.45 0.04 -0.0099
0.29 1.00 -0.33 0.05 -0.0094

______________________________________________________________________________
Pág. 5.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
ANÁLISIS DINÁMICO TIEMPO - HISTORIA MODO 1
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com
0.30 1.86 -1.21 0.04 -0.0090
0.31 1.33 -0.70 0.03 -0.0087

______________________________________________________________________________
Pág. 6.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
ANÁLISIS DINÁMICO TIEMPO - HISTORIA MODO 1
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com
D e s p la z a m ie n to (c m )

DESPLAZAMIENTO ELÁSTICO EN EL TIEMPO


10.00
8.00
6.00
4.00
2.00
0.00
-2.00 0 20 40 60 80 100 120 140 160 180

-4.00
-6.00
-8.00
-10.00
Tiempo (s)
V elocidad (cm /s)

VELOCIDAD ELÁSTICA EN EL TIEMPO


80
60
40
20
0
0 20 40 60 80 100 120 140 160 180
-20
-40
-60
-80
-100
Tiempo (s)
A c e le r a c ió n (c m /s 2 )

ACELERACIÓN ELÁSTICA EN EL TIEMPO


800

600

400

200

0
0 20 40 60 80 100 120 140 160 180
-200

-400

-600

-800
______________________________________________________________________________
Tiempo (s) Pág. 7.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
A c e le r a c i
ACELERACIÓN ELÁSTICA EN EL TIEMPO
800

600

400

200

0 ANÁLISIS DINÁMICO TIEMPO - HISTORIA MODO 1


0 20 40 60 80 100 120 140 160 180
-200 Sismo de Atico del 23/03/2001 E-W
-400 Ing. Erly Marvin Enriquez Quispe
-600 ing_erlyenriquez@hotmail.com
-800
Tiempo (s)

______________________________________________________________________________
Pág. 8.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
ANÁLISIS DINÁMICO TIEMPO - HISTORIA MODO 2
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

T: Periodo de la Estructura (s) 0.25


ωn: Frecuencia natural angular (rad/s) 25.42
ξ: Fracción de amortiguamiento crítico 0.05
ϒ: Coeficiente gama 0.50
β: Coeficiente beta 0.17
Δt: Variación del tiempo (s) 0.01

A 1.02 C 9.01
B 646.30 D 0.03

t (s) u''gi (cm/s2) u''i (cm/s2) u'i (cm/s) ui (cm)


0.00 0.07 0.07 0.00 0.0000
0.01 0.07 -0.07 0.00 0.0000
0.02 0.07 -0.07 0.00 0.0000
0.03 0.07 -0.06 0.00 0.0000
0.04 0.09 -0.06 0.00 0.0000
0.05 0.14 -0.09 0.00 -0.0001
0.06 0.27 -0.20 0.00 -0.0001
0.07 0.55 -0.44 -0.01 -0.0001
0.08 1.02 -0.82 -0.01 -0.0002
0.09 1.62 -1.28 -0.02 -0.0004
0.10 2.12 -1.55 -0.04 -0.0007
0.11 2.20 -1.29 -0.05 -0.0012
0.12 1.62 -0.32 -0.06 -0.0018
0.13 0.53 1.15 -0.06 -0.0024
0.14 -0.54 2.49 -0.04 -0.0029
0.15 -1.02 3.05 -0.01 -0.0031
0.16 -0.76 2.69 0.02 -0.0031
0.17 -0.17 1.85 0.04 -0.0028
0.18 0.18 1.14 0.06 -0.0023
0.19 0.21 0.70 0.07 -0.0017
0.20 0.29 0.17 0.07 -0.0010
0.21 0.79 -0.77 0.07 -0.0003
0.22 1.43 -1.77 0.05 0.0003
0.23 1.43 -2.01 0.03 0.0008
0.24 0.34 -1.04 0.02 0.0010
0.25 -1.37 0.56 0.02 0.0012
0.26 -2.53 1.55 0.03 0.0014
0.27 -2.26 1.02 0.04 0.0017
0.28 -0.73 -0.78 0.04 0.0022
0.29 1.00 -2.70 0.02 0.0025

______________________________________________________________________________
Pág. 9.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
ANÁLISIS DINÁMICO TIEMPO - HISTORIA MODO 2
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com
0.30 1.86 -3.53 -0.01 0.0026
0.31 1.33 -2.77 -0.04 0.0024

______________________________________________________________________________
Pág. 10.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
ANÁLISIS DINÁMICO TIEMPO - HISTORIA MODO 2
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com
D e s p la z a m ie n to (c m )

DESPLAZAMIENTO ELÁSTICO EN EL TIEMPO


0.80

0.60

0.40

0.20

0.00
0 20 40 60 80 100 120 140 160 180
-0.20

-0.40

-0.60

-0.80
Tiempo (s)
V elocidad (cm /s)

VELOCIDAD ELÁSTICA EN EL TIEMPO


20

15

10

0
0 20 40 60 80 100 120 140 160 180
-5

-10

-15

-20
Tiempo (s)
A c e le r a c ió n (c m /s 2 )

ACELERACIÓN ELÁSTICA EN EL TIEMPO


500
400
300
200
100
0
-100 0 20 40 60 80 100 120 140 160 180
-200
-300
-400
-500
______________________________________________________________________________
Tiempo (s) Pág. 11.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
A c e le r a c i
ACELERACIÓN ELÁSTICA EN EL TIEMPO
500
400
300
200
100
0 ANÁLISIS DINÁMICO TIEMPO - HISTORIA MODO 2
-100 0 20 40 60 80 100 120 140 160 180
Sismo de Atico del 23/03/2001 E-W
-200
Ing. Erly Marvin Enriquez Quispe
-300
-400 ing_erlyenriquez@hotmail.com
-500
Tiempo (s)

______________________________________________________________________________
Pág. 12.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
ANÁLISIS DINÁMICO TIEMPO - HISTORIA MODO 3
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

T: Periodo de la Estructura (s) 0.16


ωn: Frecuencia natural angular (rad/s) 39.98
ξ: Fracción de amortiguamiento crítico 0.05
ϒ: Coeficiente gama 0.50
β: Coeficiente beta 0.17
Δt: Variación del tiempo (s) 0.01

A 1.0466 C 19.99
B 1598.70 D 0.0733

t (s) pi u''i u'i ui


0.00 0.07 0.07 0.00 0.0000
0.01 0.07 -0.07 0.00 0.0000
0.02 0.07 -0.06 0.00 0.0000
0.03 0.07 -0.05 0.00 0.0000
0.04 0.09 -0.04 0.00 0.0000
0.05 0.14 -0.05 0.00 0.0000
0.06 0.27 -0.14 0.00 -0.0001
0.07 0.55 -0.34 -0.01 -0.0001
0.08 1.02 -0.67 -0.01 -0.0002
0.09 1.62 -1.00 -0.02 -0.0003
0.10 2.12 -1.08 -0.03 -0.0006
0.11 2.20 -0.58 -0.04 -0.0009
0.12 1.62 0.62 -0.04 -0.0013
0.13 0.53 2.16 -0.02 -0.0016
0.14 -0.54 3.30 0.00 -0.0017
0.15 -1.02 3.32 0.04 -0.0015
0.16 -0.76 2.13 0.06 -0.0010
0.17 -0.17 0.35 0.08 -0.0003
0.18 0.18 -1.20 0.07 0.0005
0.19 0.21 -2.18 0.06 0.0011
0.20 0.29 -2.86 0.03 0.0015
0.21 0.79 -3.47 0.00 0.0017
0.22 1.43 -3.66 -0.04 0.0015
0.23 1.43 -2.67 -0.07 0.0009
0.24 0.34 -0.26 -0.08 0.0002
0.25 -1.37 2.68 -0.07 -0.0006
0.26 -2.53 4.57 -0.04 -0.0012
0.27 -2.26 4.32 0.01 -0.0013
0.28 -0.73 2.23 0.04 -0.0010
0.29 1.00 -0.33 0.05 -0.0006

______________________________________________________________________________
Pág. 13.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
ANÁLISIS DINÁMICO TIEMPO - HISTORIA MODO 3
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com
0.30 1.86 -1.89 0.04 -0.0001
0.31 1.33 -1.79 0.02 0.0002

______________________________________________________________________________
Pág. 14.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
ANÁLISIS DINÁMICO TIEMPO - HISTORIA MODO 3
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com
D e s p la z a m ie n to (c m )

DESPLAZAMIENTO ELÁSTICO EN EL TIEMPO


0.50
0.40
0.30
0.20
0.10
0.00
-0.10 0 20 40 60 80 100 120 140 160 180

-0.20
-0.30
-0.40
-0.50
Tiempo (s)
V elocidad (cm /s)

VELOCIDAD ELÁSTICA EN EL TIEMPO


20

15

10

0
0 20 40 60 80 100 120 140 160 180
-5

-10

-15
Tiempo (s)
A c e le r a c ió n (c m /s 2 )

ACELERACIÓN ELÁSTICA EN EL TIEMPO


600

400

200

0
0 20 40 60 80 100 120 140 160 180
-200

-400

-600

-800
______________________________________________________________________________
Tiempo (s) Pág. 15.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
A c e le r a c i
ACELERACIÓN ELÁSTICA EN EL TIEMPO
600

400

200

0
0 ANÁLISIS
20 40 DINÁMICO
60 TIEMPO
80 - HISTORIA
100 MODO140
120 3 160 180
-200
Sismo de Atico del 23/03/2001 E-W
-400 Ing. Erly Marvin Enriquez Quispe
-600 ing_erlyenriquez@hotmail.com
-800
Tiempo (s)

______________________________________________________________________________
Pág. 16.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
DESPLAZAMIENTOS TOTALES DE TODOS LOS PISOS
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

𝑌_𝑖=𝑑_𝑖 (𝑡)Γ_𝑖
𝑋_𝑖
t (s) Piso 1 Piso 2 Piso 3 Piso 4 Piso 5
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
0.0100 0.0000 0.0000 0.0000 0.0000 0.0000
0.0200 0.0000 0.0000 0.0000 0.0000 0.0000
0.0300 0.0000 0.0000 0.0000 0.0000 0.0000
0.0400 0.0000 0.0000 0.0000 0.0000 0.0000
0.0500 0.0000 -0.0001 -0.0001 -0.0001 -0.0001
0.0600 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001
0.0700 -0.0001 -0.0002 -0.0002 -0.0002 -0.0002
0.0800 -0.0002 -0.0003 -0.0003 -0.0003 -0.0003
0.0900 -0.0003 -0.0006 -0.0005 -0.0005 -0.0005
0.1000 -0.0006 -0.0010 -0.0009 -0.0009 -0.0010
0.1100 -0.0010 -0.0016 -0.0015 -0.0014 -0.0016
0.1200 -0.0014 -0.0023 -0.0022 -0.0022 -0.0024
0.1300 -0.0019 -0.0032 -0.0032 -0.0031 -0.0033
0.1400 -0.0023 -0.0040 -0.0041 -0.0041 -0.0043
0.1500 -0.0026 -0.0046 -0.0050 -0.0051 -0.0052
0.1600 -0.0026 -0.0050 -0.0058 -0.0059 -0.0060
0.1700 -0.0025 -0.0051 -0.0064 -0.0067 -0.0067
0.1800 -0.0024 -0.0052 -0.0070 -0.0075 -0.0074
0.1900 -0.0022 -0.0051 -0.0074 -0.0082 -0.0081
0.2000 -0.0020 -0.0050 -0.0078 -0.0088 -0.0088
0.2100 -0.0019 -0.0050 -0.0080 -0.0094 -0.0096
0.2200 -0.0019 -0.0050 -0.0082 -0.0100 -0.0104
0.2300 -0.0020 -0.0052 -0.0084 -0.0105 -0.0113
0.2400 -0.0023 -0.0055 -0.0087 -0.0111 -0.0122
0.2500 -0.0025 -0.0058 -0.0089 -0.0117 -0.0130
0.2600 -0.0027 -0.0059 -0.0090 -0.0120 -0.0136
0.2700 -0.0026 -0.0058 -0.0088 -0.0120 -0.0137
0.2800 -0.0024 -0.0053 -0.0085 -0.0117 -0.0134
0.2900 -0.0020 -0.0049 -0.0081 -0.0113 -0.0129
0.3000 -0.0018 -0.0045 -0.0078 -0.0109 -0.0123
0.3100 -0.0017 -0.0044 -0.0076 -0.0105 -0.0117
0.3200 -0.0017 -0.0044 -0.0075 -0.0101 -0.0112
0.3300 -0.0017 -0.0044 -0.0073 -0.0096 -0.0105
0.3400 -0.0016 -0.0041 -0.0069 -0.0088 -0.0094
0.3500 -0.0012 -0.0035 -0.0061 -0.0076 -0.0080
0.3600 -0.0007 -0.0025 -0.0049 -0.0061 -0.0062
0.3700 0.0000 -0.0013 -0.0034 -0.0042 -0.0042

______________________________________________________________________________
Pág. 17.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
DESPLAZAMIENTOS TOTALES DE TODOS LOS PISOS
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

0.3800 0.0006 0.0000 -0.0017 -0.0022 -0.0020


0.3900 0.0013 0.0014 0.0003 0.0000 0.0003

______________________________________________________________________________
Pág. 18.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
DESPLAZAMIENTOS TOTALES DE TODOS LOS PISOS
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com
D e s p la z a m ie n to (c m )

DESPLAZAMIENTOS DEL PISO 1


3.00

2.00

1.00

0.00
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-1.00

-2.00

-3.00
D e s p la z a m ie n to (c m )

Tiempo (s)

DESPLAZAMIENTOS DEL PISO 2


6.00

4.00

2.00

0.00
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-2.00

-4.00

-6.00
D e s p la z a m ie n to (c m )

Tiempo (s)

DESPLAZAMIENTOS DEL PISO 3


10.00
8.00
6.00
4.00
2.00
0.00
-2.000.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-4.00
-6.00
-8.00
-10.00
______________________________________________________________________________
Tiempo (s) Pág. 19.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
D e s p la z a m ie
DESPLAZAMIENTOS DEL PISO 3
10.00
8.00
6.00
4.00
2.00
DESPLAZAMIENTOS TOTALES DE TODOS LOS PISOS
0.00 Sismo de Atico del 23/03/2001 E-W
-2.000.00 20.00 40.00
Ing. 60.00 80.00
Erly Marvin 100.00
Enriquez 120.00
Quispe 140.00 160.00 180.00
-4.00
ing_erlyenriquez@hotmail.com
D e s p la z a m ie n to (c m )

-6.00
-8.00
-10.00
Tiempo (s)

DESPLAZAMIENTOS DEL PISO 1


3.00

2.00

1.00

0.00
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-1.00

-2.00

-3.00
Tiempo (s)

______________________________________________________________________________
Pág. 20.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
DESPLAZAMIENTOS TOTALES DE TODOS LOS PISOS
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com
D e s p la z a m ie n to (c m )

DESPLAZAMIENTOS DEL PISO 4


15.00

10.00

5.00

0.00
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-5.00

-10.00

-15.00
D e s p la z a m ie n to (c m )

Tiempo (s)

DESPLAZAMIENTOS DEL PISO 5


15.00

10.00

5.00

0.00
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-5.00

-10.00

-15.00
Tiempo (s)

Piso Ymáx (cm)


1 2.3430
2 5.4273
TIEMPO - HISTORIA 3 8.1698
4 10.0140
5 10.7654

Piso Ymáx (cm)


1 2.3752
COMBINACIÓN MODAL 2 5.4118
RCSC 3 8.0959

______________________________________________________________________________
Pág. 21.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
DESPLAZAMIENTOS TOTALES DE TODOS LOS PISOS
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

4 10.0059
5 10.7810

______________________________________________________________________________
Pág. 22.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
DESPLAZAMIENTOS RELATIVOS DE TODOS LOS PISOS
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

∆_𝑖=𝑑_𝑖 (𝑡) Γ_𝑖 𝑋_𝑖−𝑑_(𝑖−1) (𝑡)


Γ_(𝑖−1) 𝑋_(𝑖−1)
t (s) Piso 1 Piso 2 Piso 3 Piso 4 Piso 5
0.00 0.00 0.00 0.00 0.00 0.00
0.01 0.00 0.00 0.00 0.00 0.00
0.02 0.00 0.00 0.00 0.00 0.00
0.03 0.00 0.00 0.00 0.00 0.00
0.04 0.00 0.00 0.00 0.00 0.00
0.05 0.00 0.00 0.00 0.00 0.00
0.06 0.00 0.00 0.00 0.00 0.00
0.07 0.00 0.00 0.00 0.00 0.00
0.08 0.00 0.00 0.00 0.00 0.00
0.09 0.00 0.00 0.00 0.00 0.00
0.10 0.00 0.00 0.00 0.00 0.00
0.11 0.00 0.00 0.00 0.00 0.00
0.12 0.00 0.00 0.00 0.00 0.00
0.13 0.00 0.00 0.00 0.00 0.00
0.14 0.00 0.00 0.00 0.00 0.00
0.15 0.00 0.00 0.00 0.00 0.00
0.16 0.00 0.00 0.00 0.00 0.00
0.17 0.00 0.00 0.00 0.00 0.00
0.18 0.00 0.00 0.00 0.00 0.00
0.19 0.00 0.00 0.00 0.00 0.00
0.20 0.00 0.00 0.00 0.00 0.00
0.21 0.00 0.00 0.00 0.00 0.00
0.22 0.00 0.00 0.00 0.00 0.00
0.23 0.00 0.00 0.00 0.00 0.00
0.24 0.00 0.00 0.00 0.00 0.00
0.25 0.00 0.00 0.00 0.00 0.00
0.26 0.00 0.00 0.00 0.00 0.00
0.27 0.00 0.00 0.00 0.00 0.00
0.28 0.00 0.00 0.00 0.00 0.00
0.29 0.00 0.00 0.00 0.00 0.00
0.30 0.00 0.00 0.00 0.00 0.00
0.31 0.00 0.00 0.00 0.00 0.00
0.32 0.00 0.00 0.00 0.00 0.00
0.33 0.00 0.00 0.00 0.00 0.00
0.34 0.00 0.00 0.00 0.00 0.00
0.35 0.00 0.00 0.00 0.00 0.00
0.36 0.00 0.00 0.00 0.00 0.00
0.37 0.00 0.00 0.00 0.00 0.00

______________________________________________________________________________
Pág. 23.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
DESPLAZAMIENTOS RELATIVOS DE TODOS LOS PISOS
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

0.38 0.00 0.00 0.00 0.00 0.00


0.39 0.00 0.00 0.00 0.00 0.00

______________________________________________________________________________
Pág. 24.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
DESPLAZAMIENTOS RELATIVOS DE TODOS LOS PISOS
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com
D e s p la z a m ie n to (c m )

DESPLAZAMIENTOS RELATIVOS DEL PISO 1


3.00

2.00

1.00

0.00
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-1.00

-2.00

-3.00
D e s p la z a m ie n to (c m )

Tiempo (s)

DESPLAZAMIENTOS RELATIVOS DEL PISO 2


4.00

3.00

2.00

1.00

0.00
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-1.00

-2.00

-3.00

-4.00
D e s p la z a m ie n to (c m )

Tiempo (s)

DESPLAZAMIENTOS RELATIVOS DEL PISO 3


4.00

3.00

2.00

1.00

0.00
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-1.00

-2.00

-3.00
______________________________________________________________________________
Tiempo (s) Pág. 25.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
D e s p la z a m ie
DESPLAZAMIENTOS RELATIVOS DEL PISO 3
4.00

3.00

2.00
DESPLAZAMIENTOS RELATIVOS DE TODOS LOS PISOS
1.00
Sismo de Atico del 23/03/2001 E-W
0.00
0.00 20.00
Ing. Erly
40.00 60.00
Marvin Enriquez
80.00
Quispe
100.00 120.00 140.00 160.00 180.00
-1.00 ing_erlyenriquez@hotmail.com
-2.00

-3.00
Tiempo (s)

______________________________________________________________________________
Pág. 26.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
DESPLAZAMIENTOS RELATIVOS DE TODOS LOS PISOS
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com
D e s p la z a m ie n to (c m )

DESPLAZAMIENTOS RELATIVOS DEL PISO 4


2.50
2.00
1.50
1.00
0.50
0.00
-0.500.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-1.00
-1.50
-2.00
-2.50
D e s p la z a m ie n to (c m )

Tiempo (s)

DESPLAZAMIENTOS RELATIVOS DEL PISO 5


1.00
0.80
0.60
0.40
0.20
0.00
-0.200.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-0.40
-0.60
-0.80
-1.00
Tiempo (s)

Piso Δmáx (cm)


1 2.3430
2 3.0885
TIEMPO - HISTORIA 3 2.7425
4 1.9906
5 0.8929

Piso Δmáx (cm)


1 2.3752
COMBINACIÓN MODAL 2 3.0399
RCSC 3 2.6966

______________________________________________________________________________
Pág. 27.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
DESPLAZAMIENTOS RELATIVOS DE TODOS LOS PISOS
Sismo de Atico del 23/03/2001 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

4 1.9315
5 0.7875

______________________________________________________________________________
Pág. 28.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
FUERZA CORTANTE EN TODOS LOS PISOS
Sismo de Lima del 03/10/1974 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

𝑉_𝑖=(𝑑_𝑖 (𝑡) Γ_𝑖 𝑋_𝑖−𝑑_(𝑖−1) (𝑡) Γ_(𝑖−1) 𝑋_(𝑖−1)


) 𝐾_𝑖
t (s) Piso 1 Piso 2 Piso 3 Piso 4 Piso 5
0.00 0.00 0.00 0.00 0.00 0.00
0.01 0.00 0.00 0.00 0.00 0.00
0.02 0.00 0.00 0.00 0.00 0.00
0.03 -0.01 0.00 0.00 0.00 0.00
0.04 -0.01 0.00 0.00 0.00 0.00
0.05 -0.02 -0.01 0.00 0.00 0.00
0.06 -0.04 -0.01 0.00 0.00 0.00
0.07 -0.06 -0.03 0.01 0.00 -0.01
0.08 -0.10 -0.04 0.01 0.00 -0.01
0.09 -0.18 -0.08 0.01 0.00 -0.02
0.10 -0.30 -0.13 0.02 0.00 -0.03
0.11 -0.49 -0.22 0.03 0.01 -0.05
0.12 -0.73 -0.34 0.03 0.01 -0.07
0.13 -0.98 -0.48 0.02 0.00 -0.08
0.14 -1.19 -0.62 -0.04 0.00 -0.08
0.15 -1.32 -0.75 -0.14 -0.02 -0.07
0.16 -1.35 -0.87 -0.28 -0.06 -0.04
0.17 -1.30 -0.96 -0.45 -0.11 0.00
0.18 -1.21 -1.04 -0.63 -0.17 0.02
0.19 -1.11 -1.09 -0.81 -0.26 0.02
0.20 -1.02 -1.13 -0.95 -0.37 -0.01
0.21 -0.96 -1.15 -1.06 -0.49 -0.08
0.22 -0.95 -1.15 -1.12 -0.62 -0.18
0.23 -1.02 -1.16 -1.14 -0.75 -0.30
0.24 -1.16 -1.18 -1.12 -0.87 -0.45
0.25 -1.30 -1.19 -1.09 -0.98 -0.58
0.26 -1.37 -1.19 -1.07 -1.06 -0.68
0.27 -1.33 -1.16 -1.07 -1.11 -0.73
0.28 -1.20 -1.11 -1.10 -1.13 -0.73
0.29 -1.03 -1.05 -1.14 -1.12 -0.68
0.30 -0.90 -1.01 -1.15 -1.08 -0.62
0.31 -0.84 -1.00 -1.14 -1.00 -0.54
0.32 -0.86 -1.00 -1.10 -0.90 -0.47
0.33 -0.87 -0.99 -1.03 -0.79 -0.38
0.34 -0.81 -0.94 -0.96 -0.66 -0.28
0.35 -0.63 -0.84 -0.90 -0.54 -0.18
0.36 -0.35 -0.68 -0.82 -0.42 -0.07
0.37 -0.02 -0.47 -0.72 -0.31 0.02

______________________________________________________________________________
Pág. 29.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
FUERZA CORTANTE EN TODOS LOS PISOS
Sismo de Lima del 03/10/1974 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

0.38 0.30 -0.23 -0.57 -0.20 0.09


0.39 0.64 0.05 -0.39 -0.11 0.13

______________________________________________________________________________
Pág. 30.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
FUERZA CORTANTE EN TODOS LOS PISOS
Sismo de Lima del 03/10/1974 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com
F u e r z a C o r ta n te (T n )

FUERZAS CORTANTES EN EL PISO 1


1500

1000

500

0
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-500

-1000

-1500
F u e r z a C o r ta n te (T n )

Tiempo (s)

FUERZAS CORTANTES EN EL PISO 2


1500

1000

500

0
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-500

-1000

-1500
F u e r z a C o r ta n te (T n )

Tiempo (s)

FUERZAS CORTANTES EN EL PISO 3


1500

1000

500

0
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-500

-1000
______________________________________________________________________________
Tiempo (s) Pág. 31.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
F uerz a C ort
FUERZAS CORTANTES EN EL PISO 3
1500

1000

500
FUERZA CORTANTE EN TODOS LOS PISOS
Sismo de Lima del 03/10/1974 E-W
0 Ing. Erly Marvin Enriquez Quispe
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
ing_erlyenriquez@hotmail.com
-500

-1000
Tiempo (s)

______________________________________________________________________________
Pág. 32.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
FUERZA CORTANTE EN TODOS LOS PISOS
Sismo de Lima del 03/10/1974 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com
F u e r z a C o r ta n te (T n )

FUERZAS CORTANTES EN EL PISO 4


800

600

400

200

0
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-200

-400

-600

-800
F u e r z a C o r ta n te (T n )

Tiempo (s)

FUERZAS CORTANTES EN EL PISO 5


500
400
300
200
100
0
0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00
-100
-200
-300
-400
Tiempo (s)

Piso Vmáx (Tn)


1 1193.25
2 1143.24
TIEMPO - HISTORIA 3 960.72
4 697.32
5 384.59

Piso Vmáx (Tn)


1 1209.67
COMBINACIÓN MODAL 2 1125.26
RCSC 3 944.64

______________________________________________________________________________
Pág. 33.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS
FUERZA CORTANTE EN TODOS LOS PISOS
Sismo de Lima del 03/10/1974 E-W
Ing. Erly Marvin Enriquez Quispe
ing_erlyenriquez@hotmail.com

4 676.61
5 339.21

______________________________________________________________________________
Pág. 34.. .
ANÁLISIS SÍSMICO LINEAL ELÁSTICO DE ESTRUCTURAS