Está en la página 1de 44

Rectificadores

Electrotecnia
Juan A. Tapia (Ph.D.)
2013-1

Juan A. Tapia Electrotecnia 1


Rectificador Media Onda

Juan A. Tapia Electrotecnia 2


Rectificador Onda Completa

Juan A. Tapia Electrotecnia 3


Rectificador Onda Completa

1 3

RL
+
4 2
Vac

Juan A. Tapia Electrotecnia 4


Rectificador Onda Completa
3
1 +
+ Vdc
Vdc –
+ 4 –
2 – Vac < 0
Vac > 0
+

Juan A. Tapia Electrotecnia 5


Sistema Trifásico

500

va vb vc 400
va vb vc va vb vc
300

200

100

0
Voltaje de fase
-100
va=Vmax sin(wt)
-200
vb=Vmax sin(wt-120)
-300
vc=Vmax sin(wt+120)
-400

-500

0 2 4 6 8 10 12

Juan A. Tapia Electrotecnia 6


Sistema Trifasico
Voltaje de línea
Voltaje de fase 500
Voltaje de línea
400
Vab= 300
Vbc=
200
Vca=
100

vab=vb-va vbc=vc-vb 0

-100
vca=va-vc
-200

vc -300
va vb
-400

-500

0 2 4 6 8 10 12

Juan A. Tapia Electrotecnia 7


Rectificador Trifásico

Juan A. Tapia Electrotecnia 8


Rectificador Trifásico

Juan A. Tapia Electrotecnia 9


Rectificador Trifásico

Juan A. Tapia Electrotecnia 10


Rectificador Trifásico

Juan A. Tapia Electrotecnia 11


Voltaje Fase-Voltaje Línea

500

400

300

200

100

-100

-200

-300

-400

-500

0 2 4 6 8 10 12

Juan A. Tapia Electrotecnia 12


Voltaje rectificado

Voltajes de fase

Electrotecnia
Juan A. Tapia 13
Corriente de carga

Corriente de diodo

Corriente en la fuente

Juan A. Tapia Electrotecnia 14


Efecto del Transformador
Corriente en la carga

Corriente secundario

Corriente primario

Juan A. Tapia Electrotecnia 15


Efecto del Transformador
Corriente en la carga

Corriente secundario

Corriente primario

Juan A. Tapia Electrotecnia 16


Juan A. Tapia Electrotecnia 17
Concepto de armónicas

400 350

300 300

200 220 2 250

100
magnitud [V]

magnitud [V]
200
0
150
-100

100
-200

-300 50

-400 0
0 1 2 3 4 5 6 7 0 100 200 300 400 500 600 700 800 900 1000
tiempo [rad] frecuencia [Hz]

Juan A. Tapia Electrotecnia 18


Armónicas
220 2 0.3 ∗ sin3))

300 350

300
200

250
100
magnitud [V]

magnitud [V]
200
0
150

-100
100

-200
50

-300 0
0 1 2 3 4 5 6 7 0 100 200 300 400 500 600 700 800 900 1000
tiempo [rad] frecuencia [Hz]

Juan A. Tapia Electrotecnia 19


Armónicas
220 2 0.3sin3)-0.5sin5))

500 350

400
300
300

200 250

100
magnitud [V]

magnitud [V]
200
0
150
-100

-200 100

-300
50
-400

-500 0
0 1 2 3 4 5 6 7 0 100 200 300 400 500 600 700 800 900 1000
tiempo [rad] frecuencia [Hz]

Juan A. Tapia Electrotecnia 20


Armónicas

400
350

300
300

200
250
100
magnitud [V]

magnitud [V]
200
0

150
-100

-200 100

-300 50

-400
0 1 2 3 4 5 6 7 0
0 100 200 300 400 500 600 700 800 900 1000
tiempo [rad]
frecuencia [Hz]

Juan A. Tapia Electrotecnia 21


Juan A. Tapia Electrotecnia 22
Juan A. Tapia Electrotecnia 23
• Basic thyristor circuits: Line-frequency voltage source connected to a load
resistance
• In the positive half cycle of vs, the current is zero until ωt=α, at which a
gate pulse of a short duration is applied
• With the thyristor conducting, vd = vs
• vd becomes zero at ωt = π
• By adjusting the firing angle α, the average dc voltage Vd and current Id
can be controlled

Juan A. Tapia Electrotecnia 24


o Basic thyristor circuits: Line-frequency voltage source connected to a RL
load
o Initially, the current is zero until ωt=α, at which the thyristor is fired
during the positive half cycle of vs
o With the thyristor conducting, current begins to flow, vd = vs
o Voltage across the inductor: vL=vs-vR
o During α to θ1, vL is positive, and the current increases
o Beyond θ1, vL is negative, and the current begins to decline
ο θ2 is the instant at which current becomes zero and stays at zero until 2π+α
at which the thyristor is fired again
Juan A. Tapia Electrotecnia 25
Juan A. Tapia Electrotecnia 26
Juan A. Tapia Electrotecnia 27
Juan A. Tapia Electrotecnia 28
Juan A. Tapia Electrotecnia 29
Operación rectificador controlado
Angulo de disparo: α=0 Vdc

Juan A. Tapia Electrotecnia 30


Operación rectificador controlado
Angulo de disparo: α=30
Vdc

Juan A. Tapia Electrotecnia 31


Operación rectificador controlado
Angulo de disparo: α=60
Vdc

Juan A. Tapia Electrotecnia 32


Operación rectificador controlado
Angulo de disparo: α=90
Vdc

Juan A. Tapia Electrotecnia 33


Operación rectificador controlado
• Voltaje medio de salida

The variation of Vd as a function of α:


Average dc voltage is positive until α=90o: this region is called
the rectifier mode of operation
Average dc voltage becomes negative beyond α=90o: this
region is called the inverter mode of operation

Juan A. Tapia Electrotecnia 34


Juan A. Tapia Electrotecnia 35
Rectificador: Modelo simple
Diodo
(No controlado)

Vdc=1.35Vac

Tiristores
(Controlado)

Vdc=1.35Vaccos α

Juan A. Tapia Electrotecnia 36


Celda electrolítica Walker

Celda 1

Celda 2

Celda 3

1 2 3 k
Celda n

Juan A. Tapia Electrotecnia 37


Modelo Celda Walker
(estado estacionario)

Juan A. Tapia Electrotecnia 38


Nave

Juan A. Tapia Electrotecnia 39


Juan A. Tapia Electrotecnia 40
Optibar busbar configuration

Juan A. Tapia Electrotecnia 41


Optibar busbar configuration

Juan A. Tapia Electrotecnia 42


Optibar busbar configuration

Juan A. Tapia Electrotecnia 43


Configuración BBS

Juan A. Tapia Electrotecnia 44

También podría gustarte