Está en la página 1de 11

Grupo 12

Fracciones molares peso molecular Fracciones Masicas


ACETATO BUTANOL ACETATO DE ACETATO
BUTANOL BUTANOL
DE ETILO [g/mol] ETILO[g/mol] DE ETILO
A2 B1 74 88.11 A2 B1
BUTANOL ACETATO DE
0.4 0.6 0.3593 0.6407
[Lb/mol] ETILO[Lb/mol]
0.1634 0.1942
Compuestos
propiedades ACETATO DE
BUTANOL AGUA Mezcla
ETILO
T promedio [°f] 116 116 68.345413 116
0.6218 0.4796 1.0013
Cp [Btu/lbm*°f] 0.5307
k [Btu/h*ft*°f] 0.0861 0.0787 0.34656 0.0814
µ [cp] 1.5269 0.3417 1.0169 0.7675
µ [lbm/ft*h] 3.6936 0.8265 2.4599 1.8567
ρ [Lb/ft^3] 49.0360 54.1550 62.2040 52.3157
s 0.7858 0.8679 0.9969 0.8384

Correccion de temperatura de pared Tw [°F] 76.626


Compuestos
propiedades ACETATO DE
BUTANOL AGUA Mezcla
ETILO
µ [cp] 2.5674 0.4313 0.9167 1.1988
µ [lbm/ft*h] 6.2105 1.0433 2.2175 2.8999
1 AES BWG 10
CORAZA TUBOS 3
propiedades
Mezcla Agua
M [lbm/h] 120000 110000
Tin [°f] 146 51
Tout [°f] 86 85.6908
T promedio [°f] 116 68.3454
Cp [Btu/lbm*°f] 0.5307 1.0013
k [Btu/h*ft*°f] 0.0814 0.3466
µ [cp] 0.7675 1.0169
µ [lbm/ft*h] 1.8567 2.4599
s 0.8384 0.9969
pr 12.1087 7.1072
rd [h*ft*°f/Btu] 0.002 0.001

4
2
ΔTml [°f] c.corriente 46.5126
ΔTml [°f] pararlelo 104.6242
R 1.7296
P 0.3652
Numero de tubos 1
α 0.5803
s 0.3652
F 0.80744
Q [Btu/h] 3820951.694
RE*NP 2664.472631
V* NP [ft/h] 2623.259621
V* NP [ft/s] 0.728683228
Velocidad 6 pasos[ft/s] 4.372099369
Numero de tubos 532

Correccion de temperatura de pared Tw [°F] 73.738


Compuestos
propiedades ACETATO DE
BUTANOL AGUA Mezcla
ETILO
µ [cp] 2.6776 0.4392 0.9508 1.2434
µ [lbm/ft*h] 6.4771 1.0623 2.3000 3.0078

Fracciones Masicas
ACETATO
BUTANOL
DE ETILO
A2 B1
0.3593 0.6407
Tubos 3/4 BWG 10
Do Di
D [in] 0.75 0.48
K material [Btu/h*ft*°f] 26
L [ft] 15
NT 532
NP 6
Tabla 5,3 boquillas tubos
Diametro nominal 8
Di[ln] 7.9810
Ren 85607.6594340321
Gn 316628.989034475

Coraza AES
Ds [in] 31
Bc 0.4
B/Ds 0.3
Pitch □ [in] 1
C´ 0.25
B [ln] 9.3
De[ln] 0.95
De[ft] 0.079166666666667
Tabla 5,3 boquillas coraza
Diametro nominal 8
Di[ln] 7.9810
Gn 345413.442583064
5 Calculo hi,ho
Rei 15986.8357862683
V [ft/h] 15739.557728584
V [ft/s] 4.37209936905111
hi [Btu/h*ft^2*°f] 880.137358630909
As[ft^2] 0.50052083333333
Go 239750.260145682
Reo 10222.7129822999

Jh 30.5803257980045
ho [Btu/h*ft^2*°f] 72.1786398156558

6 Coraza Tubos
Tw [°F] 73.738

µ w [cp] 1.2434 0.9508


µ w [lbm/ft*h] 3.007845280615 2.30000939
7 Corrección hi, ho
i o
fi 1.00945236747892 0.934689082521079
h [Btu/h*ft^2*°f] 888.456740376615 67.4645866269147
8
Calculos Termicos
Ureq[Btu/h ft^2 °F] 59.9721601081273
Uc[Btu/h ft^2 °F] 58.4611846949773
UD[Btu/h ft^2 °F] 48.3994700254832
%OS -2.51946138079039
%OD -19.2967704711303
NO SIRVE TERMICAMENTE

9
Calculos hidraulicos
Tubo
f 0.033885422969915
G_i [Lbm/ft ^2*h] 979063.448948839
Gn_i [Lbm/ft ^2*h] 316628.989034475
ΔPf [psi] 9.64340676440712
ΔPr [psi] 1.34266232756058
ΔPn [psi] 0.020113961809184
ΔPi [psi] 11.006183
PERFECTO

10
Calculos hidraulicos
Coraza
f1 0.004019556551833
f2 0.000797483096021
f 0.172834888031702
nb+1 20
ΔPf 1.0311197368161 psi
ΔPn 0.028461721072327 psi
ΔPo 1.05958145788843 psi
PERFECTO
1 AES BWG 10 3 Reynolds con 6 pasos
CORAZA TUBOS Tabla C.3
propiedades
Mezcla Agua Ds [in]
M [lbm/h] 120000 110000 NP
Tin [°f] 146 51 NT
Tout [°f] 86 85.6908 Rei
T promedio [°f] 116 68.3454 V [ft/h]
Cp [Btu/lbm*°f] 0.5307 1.0013 V [ft/s]
k [Btu/h*ft*°f] 0.0814 0.3466 hi [Btu/h*ft^2*°f]
µ [cp] 0.7675 1.0169 Corregido hi [Btu/h*ft^2*°f]
µ [lbm/ft*h] 1.8567 2.4599
s 0.8384 0.9969 4
pr 12.1087 7.1072 mm
rd [h*ft*°f/Btu] 0.002 0.001 Ds 787.4
D [in] 0.75 0.48 Do 19.05
L [ft] 15 δtb 0.4
BWG 10 Pitch □ [in] 1 δsb 3.1248
B/Ds 0.3 Ds-Dotl 38.38084
Bc 0.4 Dotl 749.01916
B [in] 9.3 Dctl 729.96916
K material [Btu/h*ft*°f] 26 5
N[numero de corazas] 1 Cálculo de areas deflujo
2 [in^2]
Usup [Btu/h*ft^2*°f] 65 Sm 80.8708704330708
ΔTml [°f] c.corriente 46.5126 θctl 2.70670337874315
ΔTml [°f] pararlelo 104.6242 Fc 0.27253668909856
R 1.7296 Stb 13.5987882425422
P 0.3652 θds 2.73887681200913
x ramas paralelas 1 Ssb 6.75852186529464
α 0.5803 Sb 14.0528272440945
s 0.3652 Fw 0.36373165545072
F 0.80744 Sw 189.3699517583
Q [Btu/h] 3820951.694
A [FT^2] 1565.236503
nt 531.4456034 532
RE*NP 2664.472631
V* NP [ft/h] 2623.259621
V* NP [ft/s] 0.728683228
4.372099369

Coraza Tubos
Tw [°F] 76.626
µ w [cp] 1.198819591 0.91672
µ w [lbm/ft*h] 2.899944592 2.21754568
Φ  0.939481821 1.01462559984
ynolds con 6 pasos 6
Coreccion de banco de tubos ideal
31
6 G [Lbm/ft ^2*h] 213673.971
576 Re 7192.77308
14765.6192 f_ideal 0.09877444
14537.2304 j 0.01007343
4.03811956 hideal [Btu/h*ft^2*°f] 216.621996
825.927211 corregido hideal [Btu/h*ft^2*°f] 203.512427
838.006892
7
Tabla 6.1
ln a1 0.107
31 a2 -0.266
0.75 a3 1.187
0.01574803 a4 0.37
0.12302362 b1 0.0815
1.51105669 b2 0.022
29.4889433 b3 6.3
28.7389433 b4 0.378
a 0.2502818
areas deflujo b 1.25542257
[ft^2] 8
0.56160327 Factores de correccion
Rad Jc 0.74622642
- rs 0.33199484
0.09443603 rl 0.25172612
Rad p 0.60020077
0.04693418 JL 0.69974964
0.09758908 RL 0.4611237
- Nc 6.2
1.31506911 NSS 3 24
rss 0.48387097
CJ 1.25
CR 3.7
Jb 0.99764161
Rb 0.99303529
Js 0.98920079
Rs 0.7452876
JR 1
Ho [Btu/h*ft^2*°f] 111.628443
Ho [Btu/h*ft^2*°f] 104.872893
11
Calculos Termicos
Ureq(Btu/h ft^2 °F) 59.972160108
Uc 83.867540782
UD 64.601232961
%OS 39.844122057
%OD 7.7187028861
13 14
Calculos hidraulicos Calculos hidraulicos
Tubo Coraza
f 0.0345886782 G_o 213673.970707 [Lbm/ft ^2*h]
G_i [Lbm/ft ^2*h] 904273.87993 Gn_o 345413.442583 [Lbm/ft ^2*h]
Gn_i [Lbm/ft ^2*h] 316628.98903 Nc 6.2 -
ΔPf [psi] 8.3542959089 Ncw 9.92 -
ΔPr [psi] 1.1489771144 ΔPideal 2.72843214242 lbf/ft^2
ΔPn [psi] 0.0201139618 ΔPw pideal 3.55355231522 lbf/ft^2
ΔPI [psi] 9.523387 ΔPf 64.1231755246 lbf/ft^2
12 ΔPf 0.44529954504 psi
Tabla 5,3 boquillas Δpe 10.5003814394 psi
Diametro nominal 8 ΔPn 0.02846172107 psi
Di[ln] 7.9810 Δpo 0.47376126611 psi

9
N1 0.6 Espacios 19
N2 0.2 Sobra 0.35483870968
L/B 19.35483871 Sobra/2 0.17741935484
Nb+1 20 1.65
Nb 19
10
in ft
B 9.3 0.775
Bin+Bout 21.9 1.825
Bin 10.95 0.9125
Bout 10.95 0.9125

También podría gustarte