Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Laboratorio4 de Fluidos
Laboratorio4 de Fluidos
HONDURAS
FACULTAD DE INGENIERÍA
LABORATORIO DE MECÁNICA DE FLUIDOS
ECUACION DE LA ENERGIA
PRESENTADO POR:
ANUHAR ARIEL ZELAYA 20111011708
SECCIÓN: “C”
Datos:
PA = 1 HP
V=5 gal.
II. Conversiones
1𝑚3
5 𝑔𝑎𝑙 × = 0.018925𝑚3
264.2 𝑔𝑎𝑙
Tubo PVC
1𝑚
Diametro interior 80.0 𝑚𝑚 × 1000𝑚𝑚 = 0.08𝑚
1 pulg= 2.54 cm
T1
101.325 𝑘𝑝𝑎
𝑃1 = 0.9𝑏𝑎𝑟 × = 91.1925 𝑘𝑝𝑎
1 𝑏𝑎𝑟.
101.325 𝑘𝑝𝑎
𝑃2 = 0.4𝑏𝑎𝑟 × = 40.53 𝑘𝑝𝑎
1 𝑏𝑎𝑟.
T2
101.325 𝑘𝑝𝑎
𝑃1 = 0.5𝑏𝑎𝑟 × = 50.6625 𝑘𝑝𝑎
1 𝑏𝑎𝑟.
𝑃2 = 0
T3
101.325 𝑘𝑝𝑎
𝑃1 = 0.5𝑏𝑎𝑟 × = 50.6625 𝑘𝑝𝑎
1 𝑏𝑎𝑟.
101.325 𝑘𝑝𝑎
𝑃2 = 0.1𝑏𝑎𝑟 × = 10.1325 𝑘𝑝𝑎
1 𝑏𝑎𝑟.
T4
1 𝑏𝑎𝑟.
2𝑝𝑠𝑖 × = 0.13605 𝑏𝑎𝑟
14.7 𝑝𝑠𝑖
101.325 𝑘𝑝𝑎
𝑃1 = 0.13605𝑏𝑎𝑟 × = 13.7853 𝑘𝑝𝑎
1 𝑏𝑎𝑟.
𝑃2 = 0
III. Cálculos:
𝑃1 𝑉12 𝑃2 𝑉22
+ 𝑧1 + + ℎ𝐴 − ℎ𝑅 − ℎ𝐿 = + 𝑧2 +
ϒ 2𝑔 ϒ 2𝑔
𝑝1 − 𝑝2 𝑉12 − 𝑉22
ℎ𝐿 = + + ℎ𝐴
ϒ 2𝑔
𝒉𝑨 = 𝑷𝑨ϒ𝑸
Calcular Q
𝑄 = 𝑉𝐴
𝑉
𝑄=
𝑡
t1 =27.1 t2 =33.4 t3 =33.8 t4 =32.0
0.018925𝑚3 −4
𝑚3
𝑄1 = = 6.9833 × 10
27.1 𝑠𝑒𝑔. 𝑠𝑒𝑔
0.018925𝑚3 −4
𝑚3
𝑄2 = = 5.6661 × 10
33.4 𝑠𝑒𝑔. 𝑠𝑒𝑔
0.018925𝑚3 −4
𝑚3
𝑄2 = = 5.5991 × 10
33.8 𝑠𝑒𝑔. 𝑠𝑒𝑔
0.018925𝑚3 −4
𝑚3
𝑄2 = = 5.9141 × 10
32.0 𝑠𝑒𝑔. 𝑠𝑒𝑔
Calculo de las velocidades
𝑄
𝑉=
𝐴
Tramo 1
𝑚3
6.9833 × 10−4 𝑠𝑒𝑔 𝑚
𝑉1 = = 1.3782
5.067 × 10−4 𝑚2 𝑠
𝑚3
6.9833 × 10−4 𝑠𝑒𝑔 𝑚
𝑉2 = = 5.516
1.266 × 10−4 𝑚2 𝑠
Tramo 2
𝛱(1 𝑝𝑢𝑙𝑔)2 2
(2.54 𝑐𝑚)2 1𝑚2
𝐴1 = = 0.7854 𝑝𝑢𝑙𝑔 × × = 5.067 × 10−4 𝑚2
4 1 𝑝𝑢𝑙𝑔 2 (100𝑐𝑚)2
𝑚3
5.6661 × 10−4 𝑠𝑒𝑔 𝑚
𝑉1 = −4 2
= 1.1182
5.067 × 10 𝑚 𝑠
3
𝑚
5.6661 × 10−4 𝑠𝑒𝑔 𝑚
𝑉2 = = 1.1182
5.067 × 10−4 𝑚2 𝑠
Tramo 3
𝛱(1 𝑝𝑢𝑙𝑔)2 (2.54 𝑐𝑚)2 1𝑚2
𝐴4 = = 0.7854 𝑝𝑢𝑙𝑔2 × × = 5.067 × 10−4 𝑚2
4 1 𝑝𝑢𝑙𝑔 2 (100𝑐𝑚)2
𝑚3
5.5991 × 10−4 𝑠𝑒𝑔 𝑚
𝑉3 = = 1.1050
5.067 × 10−4 𝑚2 𝑠
Tramo 4
𝛱(1 𝑝𝑢𝑙𝑔)2 (2.54 𝑐𝑚)2 1𝑚2
𝐴4 = = 0.7854 𝑝𝑢𝑙𝑔2 × × = 5.067 × 10−4 𝑚2
4 1 𝑝𝑢𝑙𝑔 2 (100𝑐𝑚)2
𝑚3
5.9141 × 10−4 𝑠𝑒𝑔 𝑚
𝑉4 = = 1.1672
5.067 × 10−4 𝑚2 𝑠
PERDIDAS
𝑃𝐴
ℎ𝐴 =
(ϒ)(𝑄)
764 𝑤𝑎𝑡𝑡𝑠
ℎ𝐴 = = 109.0766𝑚
𝑚3
(10030𝑁/𝑚3 )(6.9833 × 10−4 𝑠𝑒𝑔)
764 𝑤𝑎𝑡𝑡𝑠
ℎ𝐴 = = 134.4337𝑚
𝑚3
(10030𝑁/𝑚3 )(5.6661 × 10−4 𝑠𝑒𝑔)
764 𝑤𝑎𝑡𝑡𝑠
ℎ𝐴 = = 136.042𝑚
𝑚3
(10030𝑁/𝑚3 )(5.5991 × 10−4 𝑠𝑒𝑔)
764 𝑤𝑎𝑡𝑡𝑠
ℎ𝐴 = = 128.7964𝑚
𝑚3
(10030𝑁/𝑚3 )(5.9141 × 10−4 𝑠𝑒𝑔)
Perdida de la tubería
𝑝1 − 𝑝2 𝑉12 − 𝑉22
ℎ𝐿 = + + ℎ𝐴
ϒ 2𝑔
𝑚 2 𝑚 2
91.1925 𝑘𝑝𝑎 − 40.53 𝑘𝑝𝑎 (1.3782 𝑠 ) − (5.516 𝑠 )
ℎ𝐿 = + + 109.0766𝑚 = 107.62𝑚
10030𝑁/𝑚3 2 × 9.81 𝑚/𝑠 2
2 𝑚 𝑚
2
50.6625 𝑘𝑝𝑎 − 0 𝑘𝑝𝑎 (1.1182 𝑠 ) − (1.1182 𝑠 )
ℎ𝐿 = + + 134.4337𝑚 = 134.43875𝑚
10030𝑁/𝑚3 2 × 9.81 𝑚/𝑠 2
2 𝑚 2 𝑚
50.6625 𝑘𝑝𝑎 − 10.1325 𝑘𝑝𝑎 (1.1050 𝑠 ) − (1.1050 𝑠 )
ℎ𝐿 = + + 136.042𝑚 = 136.06𝑚
10030𝑁/𝑚3 2 × 9.81 𝑚/𝑠 2
2𝑚 𝑚
2
13.7853 𝑘𝑝𝑎 − 0 𝑘𝑝𝑎 (1.1672 𝑠 ) − (1.1672 𝑠 )
ℎ𝐿 = + + 128.7964𝑚 = 128.7977𝑚
10030𝑁/𝑚3 2 × 9.81 𝑚/𝑠 2
Coeficiente de resistencia
2ℎ𝐿𝑔
𝐾=
𝑣2